Study guide
Psychoacoustics, Equal Loudness Contours & Frequency Selectivity
Praxis Audiology 5343
Track your progress as you read
Finished sections get a check mark.
1 Acoustics, Psychoacoustics & Sound Measurement
Physics of Sound, Wave Propagation & Decibel Scales (SPL, HL, SL) Psychoacoustics, Equal Loudness Contours & Frequency Selectivity Speech Acoustics, Formant Structure & Auditory Perception
2 Auditory and Vestibular Anatomy and Physiology
Peripheral Auditory System: Outer, Middle & Inner Ear Transduction Vestibular End Organs, Semicircular Canals & Otolith Mechanics Central Auditory Pathways, Neuroanatomy & Lifespan Structural Maturation Auditory Behavior, Speech-Language Development & Effects of Hearing Loss Across the Lifespan
3 Auditory Pathologies, Genetics & Instrumentation
Outer, Middle, and Inner Ear Pathologies & Genetic Syndromes Nongenetic Systemic Conditions & Infectious Causes of Hearing and Balance Disorders Ototoxic Medications, Pharmacology & Monitoring Protocols Audiometric Instrumentation, Calibration Standards (ANSI S3.6) & Psychometrics
4 Prevention, Lifespan Screening & Hearing Conservation
Universal Newborn Hearing Screening & JCIH Protocols Pediatric and School-Age Hearing Screening Procedures Adult and Geriatric Hearing Screening & Self-Assessment Measures Screening for Speech-Language, Cognitive & Other Conditions and Screening Program Performance Occupational Hearing Conservation, Noise Exposure & OSHA Regulations Hearing Health Education, Fall-Risk Identification & Audiometric and Balance Monitoring
5 Behavioral Pure-Tone Audiometry & Masking
Clinical Preparation: Case History, Otoscopy & Selecting and Modifying Tests Air and Bone Conduction Pure-Tone Testing & Audiogram Interpretation Clinical Masking Principles, Interaural Attenuation & Plateau Method Non-Organic Hearing Loss, Pseudohypacusis & Stenger Testing
6 Speech Audiometry & Pediatric Behavioral Evaluation
Speech Detection & Recognition Thresholds (SDT/SRT) & Word Recognition (WRS) Speech-in-Noise Testing, PB-Max & Retrocochlear Rollover Diagnostics Central Auditory Processing Assessment: Dichotic, Temporal, Spatial & Low-Redundancy Tests Pediatric Behavioral Audiometry: BOA, VRA, and CPA
7 Acoustic Immittance & Middle Ear Diagnostics
Tympanometric Principles, Jerger Classification & Eustachian Tube Function Acoustic Reflex Thresholds, Reflex Arc Pathways & Reflex Decay Analysis Multi-Frequency Immittance, High-Frequency Probe Tones & Infant Protocols
8 Otoacoustic Emissions & Auditory Evoked Potentials
Transient and Distortion Product Otoacoustic Emissions (TEOAE & DPOAE) Auditory Brainstem Response (ABR) Diagnostic Protocols & Wave Analysis ASSR, Electrocochleography (ECochG) & Late Auditory Evoked Potentials
9 Vestibular & Balance Assessment
Videonystagmography (VNG), Oculomotor Tracking & Positional Nystagmus Bithermal Caloric Testing, Jongkees Formula & Rotational Chair Evaluation Video Head Impulse Test (vHIT), VEMP (cVEMP/oVEMP) & Dynamic Posturography (CDP) Integrating Assessment Results, Differential Diagnosis & Reporting
10 Hearing Aid Selection, Features & Prescriptive Fitting
Treatment Planning, Goal Setting, Progress Monitoring & Intervention Documentation Hearing Aid Components, Acoustic Transducers & Digital Signal Processing Prescriptive Fitting Targets (NAL-NL2 vs. DSL m[i/o]) & Dynamic Range CROS, BiCROS & Severe-to-Profound Fitting Strategies
11 Amplification Verification, Validation & Troubleshooting
Probe-Microphone Real-Ear Verification (REUR, REAR, REIG & RECD) ANSI S3.22 Electroacoustic Analysis & Quality Control Standards Clinical Validation Inventories (COSI, APHAB, SSQ) & Device Troubleshooting
12 Implantable Devices & Hearing Assistive Technology
Bone-Conduction Systems (BAHS) & Active Middle Ear Implants Cochlear Implants: Candidacy, Telemetry, MAPping Parameters & ABI Systems Hearing Assistive Technology, FM/DM Classroom Systems & Telecoils
13 Aural Rehabilitation, Tinnitus & Vestibular Management
Adult and Pediatric Aural Rehabilitation & Communication Strategies Tinnitus Management, Sound Therapy & Decreased Sound Tolerance Protocols Canalith Repositioning Maneuvers for BPPV & Vestibular Rehabilitation Therapy (VRT)
14 Ethics, Scope of Practice & Interprofessional Collaboration
ASHA and AAA Codes of Ethics, Ethical Decision-Making & Conflict of Interest Clinical Scope of Practice, CCC-A Credentialing, Licensure & Clinical Supervision Service Delivery Models, Practice Management, Risk Management & Advocacy Patient/Family Counseling & Interprofessional Practice in Education and Healthcare
15 Regulatory Compliance, Safety & Evidence-Based Practice
Federal Regulations (HIPAA, FERPA, ADA, OSHA), Billing Compliance & Infection Control Evidence-Based Practice, Research Methodology & Teleaudiology Service Delivery
Psychoacoustics, Equal Loudness Contours & Frequency Selectivity
Key Takeaways Explain This Topic AI
Minimum Audible Pressure (MAP, monaural under headphones) thresholds are 6 − 10 dB 6-10\,\text{dB} 6 − 10 dB higher (less sensitive) than Minimum Audible Field (MAF, binaural in free field) due to binaural summation and physiological pinna/ear canal acoustic resonance.
Equal loudness contours (ISO 226 / Fletcher-Munson) establish the phon scale referenced to a 1000 Hz 1000\,\text{Hz} 1000 Hz tone; the sone scale quantifies subjective loudness where 1 sone equals 40 phons, and loudness doubles with every 10 phon 10\,\text{phon} 10 phon increase.
Frequency selectivity is mediated by overlapping cochlear auditory filters parameterized by Equivalent Rectangular Bandwidths (ERBs); outer hair cell electromotility sharpens psychophysical tuning curves (PTCs).
Non-simultaneous temporal masking manifests as forward masking (persisting 100 − 200 ms 100-200\,\text{ms} 100 − 200 ms post-masker via neural adaptation) and backward masking (acting 20 − 50 ms 20-50\,\text{ms} 20 − 50 ms prior to masker onset via central processing differences).
Rayleigh's Duplex Theory dictates that low frequencies ( < 1500 Hz < 1500\,\text{Hz} < 1500 Hz ) are localized via Interaural Time Differences (ITDs) in the medial superior olive, while high frequencies ( > 1500 Hz > 1500\,\text{Hz} > 1500 Hz ) rely on Interaural Level Differences (ILDs) from head shadow in the lateral superior olive.
Last updated: October 2026
Psychoacoustics, Equal Loudness Contours & Frequency Selectivity
Psychoacoustics investigates the psychological and physiological relationship between physical acoustic parameters (sound pressure, frequency, spectrum, duration) and subjective perceptual attributes (loudness, pitch, timbre, spatial location). A doctoral grasp of psychoacoustic mechanisms is vital for configuring advanced digital signal processing in hearing instruments, interpreting auditory brainstem evaluations, and identifying central auditory processing deficits.
Absolute Sensitivity: MAP vs. MAF
Human hearing sensitivity varies systematically across frequency. Historically, psychophysicists quantified absolute audibility thresholds using two fundamental paradigms:
Minimum Audible Pressure (MAP)
Paradigm: Absolute threshold measured monaurally using an earphone (supra-aural or insert) with sound pressure determined at or near the tympanic membrane via a calibrated probe tube (or in a standard acoustic coupler).
Acoustic Characteristics: MAP measurements exclude outer ear transformations (pinna diffraction, torso reflection, and natural concha resonance). They are also elevated at low frequencies by physiological noise generated within the occluded ear canal (vascular flow, breathing, muscle contraction) and the occlusion effect.
Minimum Audible Field (MAF)
Paradigm: Absolute threshold measured binaurally in an anechoic free field with calibrated loudspeakers positioned at 0 ∘ 0^\circ 0 ∘ azimuth at a distance of 1 meter 1\,\text{meter} 1 meter from the listener's head.
Sensitivity Advantage: MAF thresholds are consistently 6 dB 6\,\text{dB} 6 dB to 10 dB 10\,\text{dB} 10 dB lower (more sensitive) than MAP thresholds across the audiometric spectrum:
Binaural Summation: Listening with two ears yields an automatic physiological threshold improvement of approximately 3 dB 3\,\text{dB} 3 dB at near-threshold levels.
Outer Ear Acoustic Resonance & Torso Diffraction: The acoustic filtering of the head, torso, pinna flange, and unobstructed external auditory meatus provides an acoustic gain of + 15 +15 + 15 to + 20 dB +20\,\text{dB} + 20 dB peak in the 2000 − 4000 Hz 2000 - 4000\,\text{Hz} 2000 − 4000 Hz region ( f r ≈ 2700 Hz f_r \approx 2700\,\text{Hz} f r ≈ 2700 Hz for an average 2.5 cm 2.5\,\text{cm} 2.5 cm adult canal acting as a quarter-wavelength resonator).
Coupler Discrepancies: Earphone couplers alter physiological impedance and lack real-ear high-frequency resonant transfer functions.
Acoustic Parameter Minimum Audible Pressure (MAP) Minimum Audible Field (MAF) Clinical Implication
Transducer Type Supra-aural (TDH-39) or Insert (ER-3A) Calibrated Soundfield Loudspeaker ( 0 ∘ 0^\circ 0 ∘ azimuth) Soundfield testing yields lower thresholds than earphone thresholds
Listening Condition Monaural (one ear isolated) Binaural (both ears unoccluded) Soundfield testing reflects the better-hearing ear only
Outer Ear Resonance Bypassed or altered by earphone coupling Fully preserved ( + 15 − 20 dB +15-20\,\text{dB} + 15 − 20 dB boost at 2.5 − 4 kHz 2.5-4\,\text{kHz} 2.5 − 4 kHz ) Real-ear-to-coupler differences (RECD) are required for infant fittings
Physiological Noise Higher at low frequencies due to occlusion Minimal (unoccluded meatus) Low-frequency soundfield thresholds are sharper than earphone tests
Equal Loudness Contours: The Phon and Sone Scales
Sound pressure level ( dB SPL \text{dB SPL} dB SPL ) does not scale linearly with human perceived loudness. Because the ear exhibits non-uniform sensitivity across frequency, tones of equal physical intensity are perceived with vastly different subjective loudness.
Equal Loudness Contours (Fletcher-Munson & ISO 226)
In 1933, Fletcher and Munson established equal loudness contours (modernized by Robinson and Dadson, and currently standardized in ISO 226:2023 ). Subjects adjusted the level of comparison tones across frequencies until they matched the subjective loudness of a reference tone at 1000 Hz 1000\,\text{Hz} 1000 Hz .
The Phon Scale: The unit of loudness level . By international definition, the loudness level of any sound in phons is numerically equal to the dB SPL \text{dB SPL} dB SPL of an equally loud 1000 Hz 1000\,\text{Hz} 1000 Hz pure tone: Loudness Level (phons) = dB SPL of equally loud 1000 Hz tone \text{Loudness Level (phons)} = \text{dB SPL of equally loud } 1000\,\text{Hz tone} Loudness Level (phons) = dB SPL of equally loud 1000 Hz tone For example, if a 100 Hz 100\,\text{Hz} 100 Hz tone must be presented at 60 dB SPL 60\,\text{dB SPL} 60 dB SPL to sound equally loud to a 1000 Hz 1000\,\text{Hz} 1000 Hz tone at 40 dB SPL 40\,\text{dB SPL} 40 dB SPL , the 100 Hz 100\,\text{Hz} 100 Hz tone has a loudness level of 40 phons 40\,\text{phons} 40 phons .
Contour Characteristics:
At low levels ( 20 − 40 phons 20-40\,\text{phons} 20 − 40 phons ), the curves bow steeply upward below 500 Hz 500\,\text{Hz} 500 Hz and above 6000 Hz 6000\,\text{Hz} 6000 Hz , reflecting the ear's poor sensitivity at the frequency extremes.
A prominent trough occurs between 2000 Hz 2000\,\text{Hz} 2000 Hz and 4000 Hz 4000\,\text{Hz} 4000 Hz , reflecting the acoustic resonance of the external ear canal and middle ear ossicular chain.
Contour Flattening at High Intensities: As intensity increases (e.g., 90 − 100 phons 90-100\,\text{phons} 90 − 100 phons ), the equal loudness contours flatten substantially. At high intensities, human hearing is nearly equally sensitive across low, middle, and high frequencies. This explains why bass notes grow disproportionately louder as overall volume is increased (the basis for loudness compensation / "bass boost" circuits at low listening levels).
The Sone Scale: Ratio Loudness
While phons establish whether two tones are equally loud, they do not quantify how much louder one sound is compared to another. Stanley Smith Stevens developed the sone scale as a true psychophysical ratio scale:
Reference: 1 sone 1\,\text{sone} 1 sone is defined as the loudness of a 1000 Hz 1000\,\text{Hz} 1000 Hz tone presented at 40 dB SPL 40\,\text{dB SPL} 40 dB SPL (i.e., 40 phons 40\,\text{phons} 40 phons ).
Stevens' Power Law: Perceived loudness follows a power function of sound pressure: L = k ⋅ P 0.6 L = k \cdot P^{0.6} L = k ⋅ P 0.6 In terms of decibels, for levels above 40 phons 40\,\text{phons} 40 phons , a 10 phon 10\,\text{phon} 10 phon increase corresponds to a doubling of perceived loudness :
40 phons = 1 sone 40\,\text{phons} = 1\,\text{sone} 40 phons = 1 sone
50 phons = 2 sones 50\,\text{phons} = 2\,\text{sones} 50 phons = 2 sones (twice as loud as 40 phons 40\,\text{phons} 40 phons )
60 phons = 4 sones 60\,\text{phons} = 4\,\text{sones} 60 phons = 4 sones (four times as loud as 40 phons 40\,\text{phons} 40 phons )
70 phons = 8 sones 70\,\text{phons} = 8\,\text{sones} 70 phons = 8 sones (eight times as loud as 40 phons 40\,\text{phons} 40 phons )
30 phons ≈ 0.5 sones 30\,\text{phons} \approx 0.5\,\text{sones} 30 phons ≈ 0.5 sones (half as loud as 40 phons 40\,\text{phons} 40 phons )
Clinical Relevance: In sensorineural hearing loss with recruitment (abnormal loudness growth secondary to outer hair cell loss), loudness grows at an accelerated rate. A patient with recruitment may perceive a 5 dB 5\,\text{dB} 5 dB physical increment above threshold as a doubling or tripling of subjective loudness.
Pitch Perception & Frequency Selectivity
Pitch is the perceptual correlate of acoustic frequency. While frequency is an objective physical rate of oscillation, pitch represents an internal psychological construct.
The Mel Scale
The mel scale (Stevens, Volkmann, & Newman, 1937) is a psychophysical scale where equal numerical intervals correspond to equal perceived pitch intervals:
Reference: A 1000 Hz 1000\,\text{Hz} 1000 Hz pure tone presented 40 dB 40\,\text{dB} 40 dB above threshold ( 40 dB SL 40\,\text{dB SL} 40 dB SL ) is assigned a pitch of 1000 mels 1000\,\text{mels} 1000 mels .
Non-Linearity: Pitch does not double when frequency doubles. Doubling perceived pitch from 1000 mels 1000\,\text{mels} 1000 mels to 2000 mels 2000\,\text{mels} 2000 mels requires raising the physical frequency from 1000 Hz 1000\,\text{Hz} 1000 Hz to approximately 3000 Hz 3000\,\text{Hz} 3000 Hz . Below 1000 Hz 1000\,\text{Hz} 1000 Hz , the relationship is approximately linear; above 1000 Hz 1000\,\text{Hz} 1000 Hz , pitch grows exponentially slower than frequency.
Theories of Pitch Perception
Two complementary neurophysiological theories explain pitch encoding:
Place Theory (Tonotopic / Traveling Wave Theory): Proposed by Georg von Békésy. The basilar membrane varies systematically in mechanical properties from base (narrow, light, stiff) to apex (wide, heavy, compliant). High-frequency tones produce peak displacement at the base; low-frequency tones travel the length of the cochlea to displace the apex. Pitch is encoded by which auditory nerve fibers are activated along the tonotopic array. Place theory accounts for pitch discrimination across all frequencies, particularly above 4000 Hz 4000\,\text{Hz} 4000 Hz .
Temporal Theory (Phase-Locking & Volley Principle): Formulated by Ernest Wever. Auditory nerve fibers discharge action potentials phase-locked to a specific point in the stimulus cycle. Because single auditory neurons have absolute and relative refractory periods limiting maximum firing rates to approximately 1000 spikes/s 1000\,\text{spikes/s} 1000 spikes/s , the Volley Principle posits that groups of neurons fire in coordinated, staggered bursts. Together, the ensemble matches stimulus periodicities up to approximately 4000 − 5000 Hz 4000 - 5000\,\text{Hz} 4000 − 5000 Hz . Above 5000 Hz 5000\,\text{Hz} 5000 Hz , phase-locking degrades completely, and the auditory system relies exclusively on place coding.
Critical Bands & Auditory Filters
Harvey Fletcher (1940) discovered that the human cochlea behaves as a bank of overlapping band-pass filters:
Critical Bandwidth: In a tone-in-noise detection experiment, Fletcher held tone level constant and progressively widened the bandwidth of centered masking noise. Tone detection threshold increased linearly with noise bandwidth up to a specific inflection point—the critical band . Once noise bandwidth exceeded the critical band, adding more noise produced zero additional masking because energy outside the filter was rejected by the cochlea.
The Bark Scale (Zwicker): Divides the audible spectrum into 24 critical bands. At low frequencies ( < 500 Hz < 500\,\text{Hz} < 500 Hz ), critical bandwidth remains roughly constant at approximately 100 Hz 100\,\text{Hz} 100 Hz . Above 500 Hz 500\,\text{Hz} 500 Hz , bandwidth widens proportionally to frequency (approximately 15 − 20 % 15 - 20\% 15 − 20% of center frequency).
Equivalent Rectangular Bandwidth (ERB): Developed by Glasberg and Moore (1990) using notched-noise masking. The auditory filter shape is quantified as an ideal rectangular filter passing equal total power: ERB ( f ) = 24.7 ( 4.37 f + 1 ) \text{ERB}(f) = 24.7(4.37f + 1) ERB ( f ) = 24.7 ( 4.37 f + 1 ) where f f f is center frequency in kHz \text{kHz} kHz . At 1000 Hz 1000\,\text{Hz} 1000 Hz ( f = 1.0 f = 1.0 f = 1.0 ), ERB = 24.7 ( 4.37 [ 1 ] + 1 ) ≈ 132.6 Hz \text{ERB} = 24.7(4.37[1] + 1) \approx 132.6\,\text{Hz} ERB = 24.7 ( 4.37 [ 1 ] + 1 ) ≈ 132.6 Hz .
Psychophysical Tuning Curves (PTCs): Measure the masker level needed to just mask a fixed, low-level probe tone across various masker frequencies. Normal PTCs feature a razor-sharp tip at the probe frequency and a steep high-frequency slope. In cochlear hearing loss, damage to outer hair cells impairs the active electromotile cochlear amplifier (prestin motors), causing PTC tips to elevate and broaden, degrading frequency resolution and speech discrimination in noise.
Acoustic Masking: Simultaneous vs. Temporal Paradigms
Masking is the process by which the threshold of audibility for one sound (the probe/signal) is elevated by the presence of another sound (the masker).
1. Simultaneous Masking
Occurs when probe and masker are presented concurrently.
Upward Spread of Masking: A low-frequency masker elevates the threshold of a higher-frequency probe much more effectively than a high-frequency masker elevates the threshold of a lower-frequency probe. Mechanism: The basilar membrane traveling wave travels from base to apex. Low-frequency energy must travel past the high-frequency basal region, exciting basal hair cells on its way, whereas high-frequency energy dissipates rapidly near the base without reaching apical low-frequency hair cells.
2. Temporal (Non-Simultaneous) Masking
Masking that occurs when signal and masker do not overlap in time:
Forward Masking (Post-stimulatory Masking): The masker precedes the probe signal. The threshold of the probe is elevated for up to 100 − 200 ms 100 - 200\,\text{ms} 100 − 200 ms following masker offset. Mechanisms: Short-term neural adaptation / synaptic depletion at the inner hair cell-auditory nerve junction, persistent basilar membrane ringing, and post-inhibitory neural suppression in the brainstem. Forward masking decreases exponentially as the silent delay between masker and probe increases.
Backward Masking (Pre-stimulatory Masking): The probe signal precedes the masker. The threshold of the probe is elevated even though it finishes before the masker begins, effective for silent intervals up to 20 − 50 ms 20 - 50\,\text{ms} 20 − 50 ms . Mechanisms: A purely central neural processing phenomenon. The intense, following masker initiates a high-velocity neural discharge in large-diameter, rapidly conducting fibers that overtakes and interferes with the weaker, slower neural volley elicited by the preceding low-level probe within the brainstem and cortex.
Binaural Hearing Advantages & Spatial Localization
Binaural auditory processing confers critical real-world advantages over monaural hearing.
Binaural Advantages
Binaural Summation:
At threshold, binaural sensitivity improves by approximately 3 dB 3\,\text{dB} 3 dB compared to monaural listening.
At suprathreshold conversational levels ( 40 − 80 dB SL 40 - 80\,\text{dB SL} 40 − 80 dB SL ), central binaural summation improves perceived loudness by 5 − 6 dB 5 - 6\,\text{dB} 5 − 6 dB , allowing lower hearing aid gain settings and reducing acoustic feedback risks.
Binaural Squelch: The central auditory nervous system (specifically the superior olivary complex) exploits interaural differences in phase and level to perceptually segregate a target speech stream from spatially disparate background noise, conferring a 2 − 3 dB 2 - 3\,\text{dB} 2 − 3 dB Signal-to-Noise Ratio (SNR) advantage.
Binaural Release from Masking / Masking Level Difference (MLD):
MLD measures the improvement in signal detection threshold when the phase relationship of the signal or the masker is reversed between ears.
Homophasic Conditions (baseline): S 0 N 0 S_0 N_0 S 0 N 0 (signal in phase, noise in phase) or S π N π S_\pi N_\pi S π N π (both signal and noise 180 ∘ 180^\circ 18 0 ∘ out of phase).
Antiphasic Conditions (release from masking): S π N 0 S_\pi N_0 S π N 0 (signal 180 ∘ 180^\circ 18 0 ∘ out of phase, noise in phase) or S 0 N π S_0 N_\pi S 0 N π (signal in phase, noise 180 ∘ 180^\circ 18 0 ∘ out of phase).
In normal listeners, shifting from S 0 N 0 S_0 N_0 S 0 N 0 to S π N 0 S_\pi N_0 S π N 0 at 500 Hz 500\,\text{Hz} 500 Hz produces a massive 12 − 15 dB 12 - 15\,\text{dB} 12 − 15 dB release from masking (the tone can be heard 15 dB 15\,\text{dB} 15 dB softer simply by phase-inverting it in one ear).
Diagnostic Value: MLD is maximal at low frequencies ( 250 − 500 Hz 250 - 500\,\text{Hz} 250 − 500 Hz ) and drops to < 3 dB < 3\,\text{dB} < 3 dB above 1000 Hz 1000\,\text{Hz} 1000 Hz . A reduced MLD ( < 7 dB < 7\,\text{dB} < 7 dB at 500 Hz 500\,\text{Hz} 500 Hz ) indicates lower brainstem pathology involving the trapezoid body and superior olivary complex (e.g., multiple sclerosis, pontine gliomas, or central auditory processing disorders).
Duplex Theory of Sound Localization (Lord Rayleigh)
Horizontal sound localization relies on two complementary acoustic cues:
Feature Interaural Time Differences (ITD) Interaural Level Differences (ILD)
Primary Frequency Range Low frequencies ( < 1500 Hz < 1500\,\text{Hz} < 1500 Hz ) High frequencies ( > 1500 Hz > 1500\,\text{Hz} > 1500 Hz )
Physical Mechanism Acoustic wave path length disparity around head Acoustic head shadow effect ( λ < \lambda < λ < head diameter)
Maximum Value ( 90 ∘ 90^\circ 9 0 ∘ Azimuth) ≈ 650 − 700 μ s \approx 650 - 700\,\mu\text{s} ≈ 650 − 700 μ s ( 0.65 − 0.7 ms 0.65 - 0.7\,\text{ms} 0.65 − 0.7 ms ) ≈ 15 − 20 dB \approx 15 - 20\,\text{dB} ≈ 15 − 20 dB at 4 − 8 kHz 4 - 8\,\text{kHz} 4 − 8 kHz ( 0 dB 0\,\text{dB} 0 dB at 0 ∘ 0^\circ 0 ∘ )
Brainstem Processing Nucleus Medial Superior Olive (MSO) Lateral Superior Olive (LSO) & Medial Nucleus of Trapezoid Body (MNTB)
Physiological Encoding Coincidence detector neurons (Jeffress model) Excitation-inhibition interactions (ipsilateral excitation, contralateral inhibition)
Vertical Localization & Cone of Confusion: Sounds originating from equidistant points along a cone radiating from the ear canal create identical ITDs and ILDs (the "cone of confusion"). Ambiguities in front-back and vertical plane localization are resolved by spectral pinna cues (pinna notches created by the convolutions of the concha and helix in the 4000 − 10 , 000 Hz 4000 - 10,000\,\text{Hz} 4000 − 10 , 000 Hz range, characterized as Head-Related Transfer Functions / HRTFs).