Study guide
Physics of Sound, Wave Propagation & Decibel Scales (SPL, HL, SL)
Praxis Audiology 5343
Track your progress as you read
Finished sections get a check mark.
1 Acoustics, Psychoacoustics & Sound Measurement
Physics of Sound, Wave Propagation & Decibel Scales (SPL, HL, SL) Psychoacoustics, Equal Loudness Contours & Frequency Selectivity Speech Acoustics, Formant Structure & Auditory Perception
2 Auditory and Vestibular Anatomy and Physiology
Peripheral Auditory System: Outer, Middle & Inner Ear Transduction Vestibular End Organs, Semicircular Canals & Otolith Mechanics Central Auditory Pathways, Neuroanatomy & Lifespan Structural Maturation Auditory Behavior, Speech-Language Development & Effects of Hearing Loss Across the Lifespan
3 Auditory Pathologies, Genetics & Instrumentation
Outer, Middle, and Inner Ear Pathologies & Genetic Syndromes Nongenetic Systemic Conditions & Infectious Causes of Hearing and Balance Disorders Ototoxic Medications, Pharmacology & Monitoring Protocols Audiometric Instrumentation, Calibration Standards (ANSI S3.6) & Psychometrics
4 Prevention, Lifespan Screening & Hearing Conservation
Universal Newborn Hearing Screening & JCIH Protocols Pediatric and School-Age Hearing Screening Procedures Adult and Geriatric Hearing Screening & Self-Assessment Measures Screening for Speech-Language, Cognitive & Other Conditions and Screening Program Performance Occupational Hearing Conservation, Noise Exposure & OSHA Regulations Hearing Health Education, Fall-Risk Identification & Audiometric and Balance Monitoring
5 Behavioral Pure-Tone Audiometry & Masking
Clinical Preparation: Case History, Otoscopy & Selecting and Modifying Tests Air and Bone Conduction Pure-Tone Testing & Audiogram Interpretation Clinical Masking Principles, Interaural Attenuation & Plateau Method Non-Organic Hearing Loss, Pseudohypacusis & Stenger Testing
6 Speech Audiometry & Pediatric Behavioral Evaluation
Speech Detection & Recognition Thresholds (SDT/SRT) & Word Recognition (WRS) Speech-in-Noise Testing, PB-Max & Retrocochlear Rollover Diagnostics Central Auditory Processing Assessment: Dichotic, Temporal, Spatial & Low-Redundancy Tests Pediatric Behavioral Audiometry: BOA, VRA, and CPA
7 Acoustic Immittance & Middle Ear Diagnostics
Tympanometric Principles, Jerger Classification & Eustachian Tube Function Acoustic Reflex Thresholds, Reflex Arc Pathways & Reflex Decay Analysis Multi-Frequency Immittance, High-Frequency Probe Tones & Infant Protocols
8 Otoacoustic Emissions & Auditory Evoked Potentials
Transient and Distortion Product Otoacoustic Emissions (TEOAE & DPOAE) Auditory Brainstem Response (ABR) Diagnostic Protocols & Wave Analysis ASSR, Electrocochleography (ECochG) & Late Auditory Evoked Potentials
9 Vestibular & Balance Assessment
Videonystagmography (VNG), Oculomotor Tracking & Positional Nystagmus Bithermal Caloric Testing, Jongkees Formula & Rotational Chair Evaluation Video Head Impulse Test (vHIT), VEMP (cVEMP/oVEMP) & Dynamic Posturography (CDP) Integrating Assessment Results, Differential Diagnosis & Reporting
10 Hearing Aid Selection, Features & Prescriptive Fitting
Treatment Planning, Goal Setting, Progress Monitoring & Intervention Documentation Hearing Aid Components, Acoustic Transducers & Digital Signal Processing Prescriptive Fitting Targets (NAL-NL2 vs. DSL m[i/o]) & Dynamic Range CROS, BiCROS & Severe-to-Profound Fitting Strategies
11 Amplification Verification, Validation & Troubleshooting
Probe-Microphone Real-Ear Verification (REUR, REAR, REIG & RECD) ANSI S3.22 Electroacoustic Analysis & Quality Control Standards Clinical Validation Inventories (COSI, APHAB, SSQ) & Device Troubleshooting
12 Implantable Devices & Hearing Assistive Technology
Bone-Conduction Systems (BAHS) & Active Middle Ear Implants Cochlear Implants: Candidacy, Telemetry, MAPping Parameters & ABI Systems Hearing Assistive Technology, FM/DM Classroom Systems & Telecoils
13 Aural Rehabilitation, Tinnitus & Vestibular Management
Adult and Pediatric Aural Rehabilitation & Communication Strategies Tinnitus Management, Sound Therapy & Decreased Sound Tolerance Protocols Canalith Repositioning Maneuvers for BPPV & Vestibular Rehabilitation Therapy (VRT)
14 Ethics, Scope of Practice & Interprofessional Collaboration
ASHA and AAA Codes of Ethics, Ethical Decision-Making & Conflict of Interest Clinical Scope of Practice, CCC-A Credentialing, Licensure & Clinical Supervision Service Delivery Models, Practice Management, Risk Management & Advocacy Patient/Family Counseling & Interprofessional Practice in Education and Healthcare
15 Regulatory Compliance, Safety & Evidence-Based Practice
Federal Regulations (HIPAA, FERPA, ADA, OSHA), Billing Compliance & Infection Control Evidence-Based Practice, Research Methodology & Teleaudiology Service Delivery
Physics of Sound, Wave Propagation & Decibel Scales (SPL, HL, SL)
Key Takeaways Explain This Topic AI
Sound propagation requires an elastic medium exhibiting mass and restoring elasticity, governed by simple harmonic motion where instantaneous displacement is modeled by d ( t ) = A sin ( 2 π f t + θ ) d(t) = A \sin(2\pi f t + \theta) d ( t ) = A sin ( 2 π f t + θ ) .
The velocity of sound ( c = E / ρ c = \sqrt{E/\rho} c = E / ρ ) depends strictly on medium stiffness and density ( 343 m/s 343\,\text{m/s} 343 m/s in air at 20 ∘ C 20^\circ\text{C} 2 0 ∘ C , ≈ 1480 m/s \approx 1480\,\text{m/s} ≈ 1480 m/s in water, and ≈ 3000 − 4000 m/s \approx 3000-4000\,\text{m/s} ≈ 3000 − 4000 m/s in cranial bone), establishing the fundamental wavelength relation λ = c / f \lambda = c/f λ = c / f .
The decibel is a logarithmic ratio scale: sound pressure level is quantified as dB SPL = 20 log 10 ( P / 20 μ Pa ) \text{dB SPL} = 20 \log_{10}(P / 20\,\mu\text{Pa}) dB SPL = 20 lo g 10 ( P /20 μ Pa ) , doubling sound pressure yields + 6 dB +6\,\text{dB} + 6 dB , while doubling sound power yields + 3 dB +3\,\text{dB} + 3 dB .
Clinical dB HL normalizes human hearing thresholds across frequency based on Reference Equivalent Threshold Sound Pressure Levels (RETSPLs, ANSI S3.6), whereas dB SL reflects presentation level relative to an individual's personal threshold.
Total acoustic impedance ( Z = R 2 + ( X m − X s ) 2 Z = \sqrt{R^2 + (X_m - X_s)^2} Z = R 2 + ( X m − X s ) 2 ) is governed by friction resistance and reactive components, where mass reactance dominates high frequencies and stiffness reactance dominates low frequencies.
Last updated: October 2026
Physics of Sound, Wave Propagation & Decibel Scales
Acoustic energy is the fundamental physical stimulus driving auditory perception and audiological diagnostics. For the clinical audiologist, a deep, quantitative understanding of wave physics, acoustic impedance, and decibel scales is not merely theoretical—it is essential for equipment calibration, differential diagnosis of middle ear pathology, and appropriate selection and verification of amplification devices.
Simple Harmonic Motion & Wave Propagation Fundamentals
Sound is generated when a vibrating object perturbs an elastic medium. This mechanical disturbance is transmitted as a longitudinal wave through sequential compressions (regions of increased particle density and positive sound pressure) and rarefactions (regions of decreased particle density and negative sound pressure).
Simple Harmonic Motion (SHM)
The simplest acoustic vibration is simple harmonic motion (SHM), producing a sinusoidal waveform. SHM is governed by two opposing physical properties:
Inertia (Mass): The tendency of a body in motion to remain in motion, or at rest to remain at rest (Newton's first law).
Elasticity (Stiffness): The restoring force that drives displaced particles back toward their equilibrium position, described by Hooke's Law ( F = − k x F = -kx F = − k x , where k k k is the stiffness constant and x x x is displacement).
The instantaneous displacement d ( t ) d(t) d ( t ) of a particle undergoing SHM as a function of time t t t is expressed by the wave equation: d ( t ) = A sin ( 2 π f t + θ ) d(t) = A \sin(2\pi f t + \theta) d ( t ) = A sin ( 2 π f t + θ ) where:
- A A A is peak displacement amplitude
- f f f is frequency in Hertz ( Hz \text{Hz} Hz )
- t t t is time in seconds ( s \text{s} s )
θ \theta θ is starting phase angle in radians or degrees ( 0 ∘ , 90 ∘ , 180 ∘ , 270 ∘ 0^\circ, 90^\circ, 180^\circ, 270^\circ 0 ∘ , 9 0 ∘ , 18 0 ∘ , 27 0 ∘ )
Frequency, Period, and Phase
Frequency ( f f f ): The number of complete oscillatory cycles completed per second, expressed in Hz \text{Hz} Hz ( 1 Hz = 1 cycle/s 1\,\text{Hz} = 1\,\text{cycle/s} 1 Hz = 1 cycle/s ).
Period ( T T T ): The time required to complete one full cycle of vibration, measured in seconds or milliseconds ( T = 1 f T = \frac{1}{f} T = f 1 ). For example, a 1000 Hz 1000\,\text{Hz} 1000 Hz tone has a period of T = 1 1000 = 0.001 s = 1.0 ms T = \frac{1}{1000} = 0.001\,\text{s} = 1.0\,\text{ms} T = 1000 1 = 0.001 s = 1.0 ms , whereas a 250 Hz 250\,\text{Hz} 250 Hz tone has a period of 4.0 ms 4.0\,\text{ms} 4.0 ms .
Phase ( θ \theta θ ): The fractional part of a cycle through which an oscillating particle has advanced relative to an arbitrary starting reference point ( 0 ∘ 0^\circ 0 ∘ at equilibrium moving positive, 90 ∘ 90^\circ 9 0 ∘ at positive peak, 180 ∘ 180^\circ 18 0 ∘ at equilibrium moving negative, 270 ∘ 270^\circ 27 0 ∘ at negative peak, and 360 ∘ 360^\circ 36 0 ∘ returning to equilibrium). Two identical pure tones combined 180 ∘ 180^\circ 18 0 ∘ out of phase perfectly cancel each other out (destructive interference).
Velocity of Sound and Wavelength
The velocity of sound ( c c c ) is strictly a property of the transmitting medium, determined by the medium's volume elasticity (bulk modulus, E E E ) and equilibrium density ( ρ \rho ρ ): c = E ρ c = \sqrt{\frac{E}{\rho}} c = ρ E
Sound travels faster through stiffer (higher elasticity), less compressible media because restoring forces rapidly accelerate displaced particles:
Air at 20 ∘ C 20^\circ\text{C} 2 0 ∘ C (dry, sea level): c ≈ 343 m/s c \approx 343\,\text{m/s} c ≈ 343 m/s (or 1125 ft/s 1125\,\text{ft/s} 1125 ft/s ). Sound velocity in air increases with temperature ( ≈ 0.6 m/s \approx 0.6\,\text{m/s} ≈ 0.6 m/s per 1 ∘ C 1^\circ\text{C} 1 ∘ C rise).
Water ( 20 ∘ C 20^\circ\text{C} 2 0 ∘ C ): c ≈ 1482 m/s c \approx 1482\,\text{m/s} c ≈ 1482 m/s (more than 4 times faster than air due to high bulk modulus).
Cranial Bone: c ≈ 3000 − 4000 m/s c \approx 3000 - 4000\,\text{m/s} c ≈ 3000 − 4000 m/s (substantially faster, directly influencing bone-conduction transducer transmission and interaural time delays during transcranial bone conduction).
Wavelength ( λ \lambda λ ): The spatial physical distance spanned by one complete cycle of a sound wave in a given medium: λ = c f \lambda = \frac{c}{f} λ = f c
Frequency ( f f f ) Period ( T T T ) Wavelength in Air ( c = 343 m/s c = 343\,\text{m/s} c = 343 m/s ) Clinical Significance
125 Hz 125\,\text{Hz} 125 Hz 8.0 ms 8.0\,\text{ms} 8.0 ms 2.74 m 2.74\,\text{m} 2.74 m ( 9.0 ft 9.0\,\text{ft} 9.0 ft ) Bypasses small obstacles; minimal head shadow
500 Hz 500\,\text{Hz} 500 Hz 2.0 ms 2.0\,\text{ms} 2.0 ms 0.686 m 0.686\,\text{m} 0.686 m ( 68.6 cm 68.6\,\text{cm} 68.6 cm ) Optimal frequency for Masking Level Difference (MLD)
1000 Hz 1000\,\text{Hz} 1000 Hz 1.0 ms 1.0\,\text{ms} 1.0 ms 0.343 m 0.343\,\text{m} 0.343 m ( 34.3 cm 34.3\,\text{cm} 34.3 cm ) Reference calibration frequency; λ \lambda λ is roughly twice the head diameter
4000 Hz 4000\,\text{Hz} 4000 Hz 0.25 ms 0.25\,\text{ms} 0.25 ms 0.086 m 0.086\,\text{m} 0.086 m ( 8.6 cm 8.6\,\text{cm} 8.6 cm ) λ < \lambda < λ < head diameter (about 17 to 20 cm), robust head shadow
8000 Hz 8000\,\text{Hz} 8000 Hz 0.125 ms 0.125\,\text{ms} 0.125 ms 0.043 m 0.043\,\text{m} 0.043 m ( 4.3 cm 4.3\,\text{cm} 4.3 cm ) Susceptible to standing waves during probe-tube calibration
Sound Pressure, Sound Intensity & The Decibel Scale
The human auditory system detects an extraordinary dynamic range of acoustic power, spanning more than 10 14 10^{14} 1 0 14 to 1 in energy from threshold to the threshold of pain. A linear scale of sound measurement is mathematically unwieldy. The decibel ( dB \text{dB} dB ) provides a compact, logarithmic scale expressing the ratio of a measured physical acoustic quantity to a standardized reference.
Sound Pressure vs. Sound Intensity
Sound Pressure ( P P P ): The force exerted perpendicular to a unit surface area by alternating acoustic compressions and rarefactions, measured in Newtons per square meter ( N/m 2 \text{N/m}^2 N/m 2 ) or Pascals ( Pa \text{Pa} Pa , where 1 Pa = 1 N/m 2 1\,\text{Pa} = 1\,\text{N/m}^2 1 Pa = 1 N/m 2 ). The audiometric reference pressure ( P 0 P_0 P 0 ) is: P 0 = 20 μ Pa = 2 × 10 − 5 Pa = 2 × 10 − 4 dyne/cm 2 P_0 = 20\,\mu\text{Pa} = 2 \times 10^{-5}\,\text{Pa} = 2 \times 10^{-4}\,\text{dyne/cm}^2 P 0 = 20 μ Pa = 2 × 1 0 − 5 Pa = 2 × 1 0 − 4 dyne/cm 2 This represents the nominal threshold of human hearing at 1000 Hz 1000\,\text{Hz} 1000 Hz under optimal listening conditions.
Sound Intensity ( I I I ): The acoustic power transmitted per unit area perpendicular to the direction of wave propagation, measured in Watts per square meter ( W/m 2 \text{W/m}^2 W/m 2 ). The audiometric reference intensity ( I 0 I_0 I 0 ) is: I 0 = 10 − 12 W/m 2 = 10 − 16 W/cm 2 I_0 = 10^{-12}\,\text{W/m}^2 = 10^{-16}\,\text{W/cm}^2 I 0 = 1 0 − 12 W/m 2 = 1 0 − 16 W/cm 2
Physical Coupling: Sound intensity is directly proportional to the square of sound pressure ( I ∝ P 2 I \propto P^2 I ∝ P 2 ). In a free acoustic field with specific acoustic impedance Z 0 Z_0 Z 0 : I = P 2 Z 0 I = \frac{P^2}{Z_0} I = Z 0 P 2
Decibel Formulas: Intensity Level and Sound Pressure Level
Using the logarithmic decibel formula:
Intensity Level ( dB IL \text{dB IL} dB IL ): dB IL = 10 log 10 ( I I 0 ) \text{dB IL} = 10 \log_{10}\left(\frac{I}{I_0}\right) dB IL = 10 lo g 10 ( I 0 I )
Sound Pressure Level ( dB SPL \text{dB SPL} dB SPL ): Because I ∝ P 2 I \propto P^2 I ∝ P 2 , substituting P 2 P^2 P 2 yields: dB SPL = 10 log 10 ( P 2 P 0 2 ) = 20 log 10 ( P P 0 ) \text{dB SPL} = 10 \log_{10}\left(\frac{P^2}{P_0^2}\right) = 20 \log_{10}\left(\frac{P}{P_0}\right) dB SPL = 10 lo g 10 ( P 0 2 P 2 ) = 20 lo g 10 ( P 0 P )
Decibel Mathematics & Summation Rules
Because decibels are logarithmic ratios, they cannot be added arithmetically.
Doubling of Sound Power / Intensity: 10 log 10 ( 2 ) ≈ + 3.01 dB 10 \log_{10}(2) \approx +3.01\,\text{dB} 10 lo g 10 ( 2 ) ≈ + 3.01 dB Adding two independent (incoherent) sound sources of equal sound level increases total level by 3 dB 3\,\text{dB} 3 dB (e.g., 65 dB SPL + 65 dB SPL = 68 dB SPL 65\,\text{dB SPL} + 65\,\text{dB SPL} = 68\,\text{dB SPL} 65 dB SPL + 65 dB SPL = 68 dB SPL ).
Doubling of Sound Pressure (Coherent / In-Phase): When two perfectly correlated, identical in-phase sound waves combine constructively, pressure doubles ( P tot = 2 P P_{\text{tot}} = 2P P tot = 2 P ): 20 log 10 ( 2 ) ≈ + 6.02 dB 20 \log_{10}(2) \approx +6.02\,\text{dB} 20 lo g 10 ( 2 ) ≈ + 6.02 dB For example, combining two identical in-phase 60 dB SPL 60\,\text{dB SPL} 60 dB SPL signals yields 66 dB SPL 66\,\text{dB SPL} 66 dB SPL .
Combining Uncorrelated Sources of Unequal Levels: When combining two sound sources differing in intensity, use the standard decibel addition rule:
Difference Between Two Sound Levels ( dB \text{dB} dB ) Amount Added to the Higher Sound Level ( dB \text{dB} dB ) Example Computation
0 − 1 dB 0 - 1\,\text{dB} 0 − 1 dB Add 3.0 dB 3.0\,\text{dB} 3.0 dB 70 dB + 70 dB = 73.0 dB 70\,\text{dB} + 70\,\text{dB} = 73.0\,\text{dB} 70 dB + 70 dB = 73.0 dB
2 − 3 dB 2 - 3\,\text{dB} 2 − 3 dB Add 2.0 dB 2.0\,\text{dB} 2.0 dB 70 dB + 68 dB = 72.0 dB 70\,\text{dB} + 68\,\text{dB} = 72.0\,\text{dB} 70 dB + 68 dB = 72.0 dB
4 − 8 dB 4 - 8\,\text{dB} 4 − 8 dB Add 1.0 dB 1.0\,\text{dB} 1.0 dB 70 dB + 64 dB = 71.0 dB 70\,\text{dB} + 64\,\text{dB} = 71.0\,\text{dB} 70 dB + 64 dB = 71.0 dB
≥ 9 dB \ge 9\,\text{dB} ≥ 9 dB Add 0.5 dB 0.5\,\text{dB} 0.5 dB or less ( ≈ 0 dB \approx 0\,\text{dB} ≈ 0 dB ) 70 dB + 55 dB = 70.1 dB 70\,\text{dB} + 55\,\text{dB} = 70.1\,\text{dB} 70 dB + 55 dB = 70.1 dB
Inverse Square Law
In a free, unbounded acoustic field (free from reflective surfaces), acoustic energy spreads spherically from a point source. The surface area of a sphere is A = 4 π r 2 A = 4\pi r^2 A = 4 π r 2 . Consequently, sound intensity varies inversely with the square of the distance from the source ( I ∝ 1 r 2 I \propto \frac{1}{r^2} I ∝ r 2 1 ).
Sound Pressure Rule: Sound pressure drops in direct proportion to distance ( P ∝ 1 r P \propto \frac{1}{r} P ∝ r 1 ).
The 6 dB 6\,\text{dB} 6 dB Rule: Every doubling of distance ( 2 r 2r 2 r ) from a sound source in a free field reduces sound pressure level by 6 dB 6\,\text{dB} 6 dB : Δ dB SPL = 20 log 10 ( r 1 r 2 ) = 20 log 10 ( 1 2 ) = − 6.02 dB \Delta \text{dB SPL} = 20 \log_{10}\left(\frac{r_1}{r_2}\right) = 20 \log_{10}\left(\frac{1}{2}\right) = -6.02\,\text{dB} Δ dB SPL = 20 lo g 10 ( r 2 r 1 ) = 20 lo g 10 ( 2 1 ) = − 6.02 dB Clinical application: In classroom acoustics, a student seated 4 meters 4\,\text{meters} 4 meters from a teacher experiences a 12 dB 12\,\text{dB} 12 dB reduction in direct speech signal compared to a student seated 1 meter 1\,\text{meter} 1 meter away ( 1 m → 2 m = − 6 dB 1\,\text{m} \to 2\,\text{m} = -6\,\text{dB} 1 m → 2 m = − 6 dB ; 2 m → 4 m = − 6 dB 2\,\text{m} \to 4\,\text{m} = -6\,\text{dB} 2 m → 4 m = − 6 dB ; total − 12 dB -12\,\text{dB} − 12 dB ).
Decibel Scales in Clinical Practice: dB SPL, dB HL, and dB SL
Clinical audiometry utilizes three distinct decibel references. Conflating these references leads to catastrophic errors in diagnostic interpretation, masking calculations, and hearing aid programming.
1. Decibel Sound Pressure Level (dB SPL)
Reference: Absolute physical sound pressure of 20 μ Pa 20\,\mu\text{Pa} 20 μ Pa ( 0 dB SPL = 20 μ Pa 0\,\text{dB SPL} = 20\,\mu\text{Pa} 0 dB SPL = 20 μ Pa ).
Application: Physical sound measurement, sound level meters, hearing aid electroacoustic analysis (ANSI S3.22), probe-tube real-ear measurements (REAR, REUR), and otoacoustic emission measurements.
Linearity: Independent of human hearing sensitivity. 80 dB SPL 80\,\text{dB SPL} 80 dB SPL represents the exact same physical pressure whether presented at 125 Hz 125\,\text{Hz} 125 Hz or 4000 Hz 4000\,\text{Hz} 4000 Hz .
2. Decibel Hearing Level (dB HL)
Reference: Human auditory threshold sensitivity across frequency, standardized by ANSI S3.6 and ISO 389.
Minimum Audibility Curve: The human ear is not equally sensitive at all frequencies. It requires significantly more physical pressure to detect a 125 Hz 125\,\text{Hz} 125 Hz or 8000 Hz 8000\,\text{Hz} 8000 Hz tone than a 1000 Hz 1000\,\text{Hz} 1000 Hz or 3000 Hz 3000\,\text{Hz} 3000 Hz tone.
RETSPL (Reference Equivalent Threshold Sound Pressure Level): The exact dB SPL required to reach the threshold of hearing ( 0 dB HL 0\,\text{dB HL} 0 dB HL ) in a normal-hearing population for a specific transducer and acoustic coupler.
An audiometer dial setting of 0 dB HL 0\,\text{dB HL} 0 dB HL outputs different dB SPL levels at each frequency to account for the human audibility curve. dB SPL = dB HL + RETSPL \text{dB SPL} = \text{dB HL} + \text{RETSPL} dB SPL = dB HL + RETSPL dB HL = dB SPL − RETSPL \text{dB HL} = \text{dB SPL} - \text{RETSPL} dB HL = dB SPL − RETSPL
Frequency ( Hz \text{Hz} Hz ) TDH-39 / TDH-49 Supra-aural (NBS-9A Coupler) RETSPL ( dB SPL \text{dB SPL} dB SPL ) ER-3A / ER-5A Insert Earphones (HA-2 Coupler, Rigid Tube) RETSPL ( dB SPL \text{dB SPL} dB SPL ) B-71 Bone Vibrator (Mastoid, Artificial Mastoid) RETSPL ( dB ref 1 μ N \text{dB ref } 1\,\mu\text{N} dB ref 1 μ N )
- 250 250 250 25.5 25.5 25.5 14.0 14.0 14.0 67.0 67.0 67.0
- 500 500 500 11.5 11.5 11.5 5.5 5.5 5.5 58.0 58.0 58.0
- 1000 1000 1000 7.0 7.0 7.0 0.0 0.0 0.0 42.5 42.5 42.5
- 2000 2000 2000 9.0 9.0 9.0 3.0 3.0 3.0 31.0 31.0 31.0
- 4000 4000 4000 9.5 9.5 9.5 5.5 5.5 5.5 35.5 35.5 35.5
- 8000 8000 8000 13.0 13.0 13.0 0.0 0.0 0.0 —
Clinical Calculation Example: If an audiometer outputs a 500 Hz 500\,\text{Hz} 500 Hz tone at 50 dB HL 50\,\text{dB HL} 50 dB HL through TDH-39 headphones (where RETSPL is 11.5 dB SPL 11.5\,\text{dB SPL} 11.5 dB SPL ), the physical output in the calibration coupler is 50 + 11.5 = 61.5 dB SPL 50 + 11.5 = 61.5\,\text{dB SPL} 50 + 11.5 = 61.5 dB SPL . If using ER-3A insert earphones (where RETSPL is 5.5 dB SPL 5.5\,\text{dB SPL} 5.5 dB SPL ), 50 dB HL 50\,\text{dB HL} 50 dB HL corresponds to 50 + 5.5 = 55.5 dB SPL 50 + 5.5 = 55.5\,\text{dB SPL} 50 + 5.5 = 55.5 dB SPL .
3. Decibel Sensation Level (dB SL)
Reference: The individual patient's personal behavioral threshold at a specified frequency or for a specific stimulus.
Formula: Presentation Level (dB SL) = Presentation Level (dB HL) − Patient Threshold (dB HL) \text{Presentation Level (dB SL)} = \text{Presentation Level (dB HL)} - \text{Patient Threshold (dB HL)} Presentation Level (dB SL) = Presentation Level (dB HL) − Patient Threshold (dB HL)
Application: Suprathreshold diagnostic testing, including Word Recognition Score (WRS, routinely administered at + 30 +30 + 30 to + 40 dB SL +40\,\text{dB SL} + 40 dB SL above the patient's SRT or pure-tone average), acoustic reflex threshold testing, and Tone Decay / PIPB rollover testing.
Diagnostic Trap: Presenting speech at a fixed level of 40 dB HL 40\,\text{dB HL} 40 dB HL to a patient with a 40 dB HL 40\,\text{dB HL} 40 dB HL threshold provides 0 dB SL 0\,\text{dB SL} 0 dB SL (inaudible or barely audible), whereas presenting at 40 dB SL 40\,\text{dB SL} 40 dB SL requires an audiometer dial setting of 80 dB HL 80\,\text{dB HL} 80 dB HL .
- Acoustic Impedance, Resonance & Acoustic Filtering
- Acoustic Impedance ( Z Z Z )
Acoustic impedance ( Z Z Z ) represents the total opposition encountered by an acoustic wave propagating through a mechanical or acoustic system (such as the middle ear). Measured in acoustic ohms ( Pa ⋅ s/m 3 \text{Pa}\cdot\text{s/m}^3 Pa ⋅ s/m 3 ), impedance comprises resistive and reactive components: Z = R 2 + ( X m − X s ) 2 Z = \sqrt{R^2 + (X_m - X_s)^2} Z = R 2 + ( X m − X s ) 2 where:
Acoustic Resistance ( R R R ): Dissipative opposition caused by friction and viscosity (e.g., perilymph viscosity, middle ear mucosa, air resistance in the middle ear cavity). Resistance is largely independent of frequency.
Mass Reactance ( X m X_m X m ): Energy storage opposition due to inertia and physical mass (e.g., mass of the tympanic membrane, ossicles, and perilymph): X m = 2 π f M X_m = 2\pi f M X m = 2 π f M Mass reactance is directly proportional to frequency . As frequency increases, mass reactance increases linearly, impeding high-frequency energy transfer.
Stiffness Reactance ( X s X_s X s ): Energy storage opposition due to elasticity and compliance (e.g., tension of the tympanic membrane, ossicular ligaments, tendon of the stapedius muscle, air volume elasticity of the tympanic cavity): X s = 1 2 π f C = K 2 π f X_s = \frac{1}{2\pi f C} = \frac{K}{2\pi f} X s = 2 π f C 1 = 2 π f K where C C C is acoustic compliance and K K K is stiffness. Stiffness reactance is inversely proportional to frequency . At low frequencies, stiffness reactance is exceptionally high, impeding low-frequency transmission.
Resonance
Natural resonance occurs at the specific frequency ( f 0 f_0 f 0 ) where mass reactance equals stiffness reactance ( X m = X s X_m = X_s X m = X s ): 2 π f 0 M = 1 2 π f 0 C ⟹ f 0 = 1 2 π M C 2\pi f_0 M = \frac{1}{2\pi f_0 C} \implies f_0 = \frac{1}{2\pi \sqrt{M C}} 2 π f 0 M = 2 π f 0 C 1 ⟹ f 0 = 2 π MC 1 At resonance, ( X m − X s ) = 0 (X_m - X_s) = 0 ( X m − X s ) = 0 , the reactive forces cancel out completely, and total impedance reaches its absolute minimum, equal solely to resistance ( Z = R Z = R Z = R ). Sound transmission through the system is maximized.
Middle Ear Resonant Frequency: In normal human adults, the middle ear resonant frequency typically ranges from 800 Hz 800\,\text{Hz} 800 Hz to 1200 Hz 1200\,\text{Hz} 1200 Hz (mean ≈ 1000 Hz \approx 1000\,\text{Hz} ≈ 1000 Hz ).
Pathological Shifts:
Stiffness-dominated pathologies (e.g., otosclerosis, middle ear effusion, lateral ossicular fixation): Stiffness ( K K K ) increases, causing resonant frequency to shift upward ( > 1200 Hz > 1200\,\text{Hz} > 1200 Hz ). This selectively attenuates low-frequency transmission, producing a low-frequency conductive air-bone gap.
Mass-dominated pathologies (e.g., ossicular chain discontinuity, monomeric tympanic membrane): Stiffness drops and relative mass increases, shifting resonant frequency downward ( < 700 Hz < 700\,\text{Hz} < 700 Hz ).
Acoustic Filters
An acoustic filter is an acoustic system or electronic circuit that selectively transmits certain frequency components while attenuating others.
Low-pass filter: Transmits all frequencies below a cutoff frequency ( f c f_c f c ) and attenuates frequencies above f c f_c f c .
High-pass filter: Transmits all frequencies above f c f_c f c and attenuates frequencies below f c f_c f c .
Band-pass filter: Transmits a specific band of frequencies bounded by a lower cutoff ( f 1 f_1 f 1 ) and upper cutoff ( f 2 f_2 f 2 ). Characterized by center frequency ( f 0 = f 1 f 2 f_0 = \sqrt{f_1 f_2} f 0 = f 1 f 2 ), bandwidth ( B W = f 2 − f 1 BW = f_2 - f_1 B W = f 2 − f 1 ), and filter sharpness/quality factor ( Q = f 0 B W Q = \frac{f_0}{BW} Q = B W f 0 ). The cochlea behaves as a bank of overlapping band-pass auditory filters.
Band-reject (Notch) filter: Attenuates a narrow frequency band while passing all frequencies above and below (e.g., 60 Hz 60\,\text{Hz} 60 Hz electrical line-noise rejection filters in ABR equipment).
Filter Roll-off (Slope): The steepness of attenuation beyond the cutoff frequency, measured in decibels per octave ( dB/oct \text{dB/oct} dB/oct ) or decibels per decade. A single-pole acoustic filter attenuates at 6 dB/oct 6\,\text{dB/oct} 6 dB/oct ; a two-pole filter rolls off at 12 dB/oct 12\,\text{dB/oct} 12 dB/oct ; steep multi-pole digital filters achieve > 24 − 48 dB/oct > 24-48\,\text{dB/oct} > 24 − 48 dB/oct .