Study guide

CROS, BiCROS & Severe-to-Profound Fitting Strategies

Praxis Audiology 5343

Track your progress as you read

Finished sections get a check mark.

1 Acoustics, Psychoacoustics & Sound Measurement

Physics of Sound, Wave Propagation & Decibel Scales (SPL, HL, SL) Psychoacoustics, Equal Loudness Contours & Frequency Selectivity Speech Acoustics, Formant Structure & Auditory Perception

2 Auditory and Vestibular Anatomy and Physiology

Peripheral Auditory System: Outer, Middle & Inner Ear Transduction Vestibular End Organs, Semicircular Canals & Otolith Mechanics Central Auditory Pathways, Neuroanatomy & Lifespan Structural Maturation Auditory Behavior, Speech-Language Development & Effects of Hearing Loss Across the Lifespan

3 Auditory Pathologies, Genetics & Instrumentation

Outer, Middle, and Inner Ear Pathologies & Genetic Syndromes Nongenetic Systemic Conditions & Infectious Causes of Hearing and Balance Disorders Ototoxic Medications, Pharmacology & Monitoring Protocols Audiometric Instrumentation, Calibration Standards (ANSI S3.6) & Psychometrics

4 Prevention, Lifespan Screening & Hearing Conservation

Universal Newborn Hearing Screening & JCIH Protocols Pediatric and School-Age Hearing Screening Procedures Adult and Geriatric Hearing Screening & Self-Assessment Measures Screening for Speech-Language, Cognitive & Other Conditions and Screening Program Performance Occupational Hearing Conservation, Noise Exposure & OSHA Regulations Hearing Health Education, Fall-Risk Identification & Audiometric and Balance Monitoring

5 Behavioral Pure-Tone Audiometry & Masking

Clinical Preparation: Case History, Otoscopy & Selecting and Modifying Tests Air and Bone Conduction Pure-Tone Testing & Audiogram Interpretation Clinical Masking Principles, Interaural Attenuation & Plateau Method Non-Organic Hearing Loss, Pseudohypacusis & Stenger Testing

6 Speech Audiometry & Pediatric Behavioral Evaluation

Speech Detection & Recognition Thresholds (SDT/SRT) & Word Recognition (WRS) Speech-in-Noise Testing, PB-Max & Retrocochlear Rollover Diagnostics Central Auditory Processing Assessment: Dichotic, Temporal, Spatial & Low-Redundancy Tests Pediatric Behavioral Audiometry: BOA, VRA, and CPA

7 Acoustic Immittance & Middle Ear Diagnostics

Tympanometric Principles, Jerger Classification & Eustachian Tube Function Acoustic Reflex Thresholds, Reflex Arc Pathways & Reflex Decay Analysis Multi-Frequency Immittance, High-Frequency Probe Tones & Infant Protocols

8 Otoacoustic Emissions & Auditory Evoked Potentials

Transient and Distortion Product Otoacoustic Emissions (TEOAE & DPOAE) Auditory Brainstem Response (ABR) Diagnostic Protocols & Wave Analysis ASSR, Electrocochleography (ECochG) & Late Auditory Evoked Potentials

9 Vestibular & Balance Assessment

Videonystagmography (VNG), Oculomotor Tracking & Positional Nystagmus Bithermal Caloric Testing, Jongkees Formula & Rotational Chair Evaluation Video Head Impulse Test (vHIT), VEMP (cVEMP/oVEMP) & Dynamic Posturography (CDP) Integrating Assessment Results, Differential Diagnosis & Reporting

10 Hearing Aid Selection, Features & Prescriptive Fitting

Treatment Planning, Goal Setting, Progress Monitoring & Intervention Documentation Hearing Aid Components, Acoustic Transducers & Digital Signal Processing Prescriptive Fitting Targets (NAL-NL2 vs. DSL m[i/o]) & Dynamic Range CROS, BiCROS & Severe-to-Profound Fitting Strategies

11 Amplification Verification, Validation & Troubleshooting

Probe-Microphone Real-Ear Verification (REUR, REAR, REIG & RECD) ANSI S3.22 Electroacoustic Analysis & Quality Control Standards Clinical Validation Inventories (COSI, APHAB, SSQ) & Device Troubleshooting

12 Implantable Devices & Hearing Assistive Technology

Bone-Conduction Systems (BAHS) & Active Middle Ear Implants Cochlear Implants: Candidacy, Telemetry, MAPping Parameters & ABI Systems Hearing Assistive Technology, FM/DM Classroom Systems & Telecoils

13 Aural Rehabilitation, Tinnitus & Vestibular Management

Adult and Pediatric Aural Rehabilitation & Communication Strategies Tinnitus Management, Sound Therapy & Decreased Sound Tolerance Protocols Canalith Repositioning Maneuvers for BPPV & Vestibular Rehabilitation Therapy (VRT)

14 Ethics, Scope of Practice & Interprofessional Collaboration

ASHA and AAA Codes of Ethics, Ethical Decision-Making & Conflict of Interest Clinical Scope of Practice, CCC-A Credentialing, Licensure & Clinical Supervision Service Delivery Models, Practice Management, Risk Management & Advocacy Patient/Family Counseling & Interprofessional Practice in Education and Healthcare

15 Regulatory Compliance, Safety & Evidence-Based Practice

Federal Regulations (HIPAA, FERPA, ADA, OSHA), Billing Compliance & Infection Control Evidence-Based Practice, Research Methodology & Teleaudiology Service Delivery

CROS, BiCROS & Severe-to-Profound Fitting Strategies

Key Takeaways Explain This Topic AI

Single-Sided Deafness (SSD) produces three distinct psychoacoustic impairments: catastrophic loss of horizontal localization, loss of binaural summation/squelch ( 1 − 3 dB 1-3\,\text{dB} 1 − 3 dB SNR advantage), and the head shadow effect ( 6 − 12 dB 6-12\,\text{dB} 6 − 12 dB high-frequency attenuation across the cranium).

Contralateral Routing of Offsite Signals (CROS) is indicated when one ear has unaidable hearing and the contralateral ear has normal hearing; sound from the poorer side is wirelessly routed to an open receiver on the normal ear without providing net amplification.

Bilateral Contralateral Routing of Offsite Signals (BiCROS) is indicated when one ear is unaidable and the contralateral (better) ear exhibits aidable sensorineural hearing loss; the better-ear hearing aid processes and amplifies both its own microphone input and the transmitted contralateral signal.

Cochlear dead regions denote complete functional absence of inner hair cells (IHCs) along a basilar membrane segment, identified by Threshold Equalizing Noise (TEN) testing; amplifying dead regions exceeding 1.5 − 2 octaves 1.5-2\,\text{octaves} 1.5 − 2 octaves causes off-frequency distortion and degrades speech recognition.

Frequency lowering strategies (frequency compression, frequency transposition, frequency translation) lower high-frequency phonemes (/s/, /z/, /ʃ/) into lower audible frequency bands; verification via probe-microphone speech mapping ensures fricative audibility without overlapping vowel formants.

Last updated: October 2026

CROS, BiCROS & Severe-to-Profound Fitting Strategies

Asymmetric sensorineural hearing loss, Single-Sided Deafness (SSD), and severe-to-profound cochlear impairment present unique rehabilitative challenges. Standard bilateral hearing aid fittings are ineffective when one ear cannot benefit from direct amplification due to poor speech discrimination, or when cochlear dead regions render amplification counterproductive.

Single-Sided Deafness (SSD) & Psychoacoustic Deficits

Single-Sided Deafness (SSD) refers to a clinical presentation where one ear exhibits profound sensorineural hearing loss or an unaidable word recognition score (WRS < 20 − 30 % < 20-30\% < 20 − 30% ), while the contralateral ear has normal or aidable hearing. SSD causes three profound auditory processing deficits:

1. The Head Shadow Effect

The human head acts as an acoustic barrier for sound waves whose wavelengths are shorter than the diameter of the head ( > 1.5 − 2.0 kHz > 1.5-2.0\,\text{kHz} > 1.5 − 2.0 kHz ). Sounds arriving from the side of the deafened ear are physically blocked by the skull. While low-frequency sounds ( < 1 kHz < 1\,\text{kHz} < 1 kHz ) bend around the head via diffraction, high-frequency speech sounds (critical for consonant clarity) are attenuated by 6 6 6 to 12 dB 12\,\text{dB} 12 dB before reaching the hearing ear. In reverberant, noisy environments where speech originates from the impaired side, speech understanding is severely compromised.

2. Loss of Binaural Squelch & Binaural Summation

Binaural Squelch: When listening with two functional ears, the central auditory nervous system compares the disparate phase and amplitude cues arriving at both ears, effectively suppressing background noise and improving the internal signal-to-noise ratio by + 2 +2 + 2 to 3 dB 3\,\text{dB} 3 dB . SSD abolishes binaural squelch.

Binaural Summation: Central integration of acoustic energy from two ears improves pure-tone thresholds by approximately 3 dB 3\,\text{dB} 3 dB and suprathreshold loudness perception by 5 − 6 dB 5-6\,\text{dB} 5 − 6 dB . In SSD, the patient must rely entirely on monaural acoustic input.

3. Loss of Horizontal Sound Localization

Horizontal plane sound localization requires comparison of acoustic arrival differences between the two ears:

Interaural Time Differences (ITD): Low frequencies ( < 1.5 kHz < 1.5\,\text{kHz} < 1.5 kHz ) provide sub-millisecond arrival time cues processed by the medial superior olive (MSO).

Interaural Level Differences (ILD): High frequencies ( > 1.5 kHz > 1.5\,\text{kHz} > 1.5 kHz ) create intensity differences processed by the lateral superior olive (LSO).

In SSD, all sound localization in the horizontal plane is lost. Patients cannot determine the direction of approaching vehicles, speakers in group settings, or warning sirens.

CROS vs. BiCROS Systems

Contralateral routing technology overcomes the head shadow effect by capturing sound on the unaidable side and wirelessly streaming it to the better hearing ear. [UN-AIDABLE EAR] [BETTER HEARING EAR]

  • Transmitter Mic Receiver / Hearing Aid
  • | |
  • +=====( Wireless 2.4 GHz / NFMI Stream )========>|
  • v
  • [CROS]: Open coupling, 0 dB Gain
  • [BiCROS]: Amplifies local + streamed sound
  • 1. CROS (Contralateral Routing of Offsite Signals)

Candidacy: One ear has unaidable profound hearing loss (or zero usable speech discrimination); the contralateral ear has normal hearing across all frequencies (thresholds ≤ 20 − 25 dB HL \le 20-25\,\text{dB HL} ≤ 20 − 25 dB HL from 250 250 250 to 8000 Hz 8000\,\text{Hz} 8000 Hz ).

Mechanics:

The unaidable ear wears a CROS transmitter , consisting of a microphone array, DSP encoder, and wireless radio.

The normal ear wears a CROS receiver fitted with an open-fit silicone dome or widely vented hollow canal mold.

Audio picked up on the unaidable side is transmitted via Near-Field Magnetic Induction (NFMI) or 2.4 GHz 2.4\,\text{GHz} 2.4 GHz digital radio to the normal ear.

Acoustic Gain Prescribed: The CROS receiver applies zero net acoustic amplification ( 0 dB 0\,\text{dB} 0 dB insertion gain) . Its sole purpose is to reproduce the contralateral sound in the normal ear canal without occluding natural sound.

Crucial Patient Expectation: CROS does not restore horizontal sound localization or true binaural hearing because all sound arrives at a single cochlea. It resolves the head shadow effect, allowing the patient to hear individuals speaking into their deaf side without physically turning their head.

2. BiCROS (Bilateral Contralateral Routing of Offsite Signals)

Candidacy: One ear is unaidable (profound loss or non-functional discrimination); the contralateral (better) ear has aidable sensorineural hearing loss (mild to moderately severe loss requiring amplification).

Mechanics:

The unaidable ear wears a wireless transmitter.

The better ear wears a fully functional hearing aid coupled with an appropriately vented earmold or dome.

The hearing aid on the better ear contains an internal mixer that combines inputs from its own local microphone with the wireless stream from the contralateral transmitter.

The processor applies prescriptive WDRC amplification to the combined signal to meet target audibility for the better ear's hearing loss.

Transmitter-to-Receiver Ratio: The balance between the local hearing aid microphone and the transmitted contralateral microphone is clinically adjustable (typically 1 : 1 1:1 1 : 1 , or adjusted to prioritize local conversation).

Feature CROS Fitting BiCROS Fitting Transcutaneous Bone-Conduction (BAHS) Cochlear Implant for SSD

Poorer Ear Status Unaidable / Profound loss Unaidable / Profound loss Unaidable / Profound loss Unaidable / Profound loss

Better Ear Status Normal hearing ( ≤ 20 − 25 dB HL \le 20-25\,\text{dB HL} ≤ 20 − 25 dB HL ) Aidable SNHL ( 30 − 70 dB HL 30-70\,\text{dB HL} 30 − 70 dB HL ) Normal hearing (or mild SNHL) Normal hearing (or mild SNHL)

Hardware Configuration Transmitter on bad ear; open receiver on good ear Transmitter on bad ear; full hearing aid on better ear Osseointegrated abutment or magnetic implant on bad side Electrode array implanted directly into deaf cochlea

Transmission Mode Wireless radio ( 2.4 GHz 2.4\,\text{GHz} 2.4 GHz / NFMI) Wireless radio ( 2.4 GHz 2.4\,\text{GHz} 2.4 GHz / NFMI) Transcranial bone conduction through skull Direct electrical stimulation of auditory nerve

Restores Localization? No (monaural input to single cochlea) No (monaural input to single cochlea) No (sound stimulates contralateral cochlea) Yes (restores true binaural ITD/ILD processing)

Eliminates Head Shadow? Yes Yes Yes Yes

Severe-to-Profound SNHL: Cochlear Dead Regions

When sensorineural hearing loss exceeds 70 − 80 dB HL 70-80\,\text{dB HL} 70 − 80 dB HL , the underlying pathology frequently involves complete destruction of both outer hair cells and inner hair cells (IHCs), along with degeneration of corresponding spiral ganglion neurons along a discrete segment of the basilar membrane. This acoustic void is termed a cochlear dead region .

Off-Frequency Listening

When a high-level pure tone is presented within a dead region, no functional IHCs respond at that characteristic frequency. However, as the stimulus intensity increases ( > 70 − 85 dB HL > 70-85\,\text{dB HL} > 70 − 85 dB HL ), the basilar membrane vibration envelope spreads to adjacent, healthier cochlear segments that still possess functional IHCs. The patient perceives the tone, but via off-frequency listening (detecting high frequencies through lower-frequency hair cells). This yields an elevated audiometric threshold, but the brain receives distorted, smeared tonotopic information.

The TEN (Threshold Equalizing Noise) Test

Developed by Brian C.J. Moore and colleagues, the TEN test provides an objective, psychophysically validated protocol to diagnose cochlear dead regions:

Stimulus: A calibrated broadband masking noise that produces equal masked pure-tone thresholds across all test frequencies ( 500 500 500 to 4000 Hz 4000\,\text{Hz} 4000 Hz ) in ears with functioning IHCs.

Protocol:

Measure unmasked pure-tone thresholds at the test frequencies.

Introduce TEN(HL) noise, specified in dB HL per ERB, at a level at or above the unmasked threshold (often about 10 dB above it). Re-measure pure-tone thresholds in the presence of the continuous TEN noise.

Diagnostic Criteria for a Dead Region: A cochlear dead region is present at the test frequency if BOTH criteria are met: Threshold Tone+TEN − Level TEN ≥ 10 dB \text{Threshold}_{\text{Tone+TEN}} - \text{Level}_{\text{TEN}} \ge 10\,\text{dB} Threshold Tone+TEN ​ − Level TEN ​ ≥ 10 dB AND Threshold Tone+TEN − Threshold Unmasked ≥ 10 dB \text{AND} \quad \text{Threshold}_{\text{Tone+TEN}} - \text{Threshold}_{\text{Unmasked}} \ge 10\,\text{dB} AND Threshold Tone+TEN ​ − Threshold Unmasked ​ ≥ 10 dB

Clinical Fitting Implications of Dead Regions

Extensive Dead Regions ( > 1.5 − 2.0 octaves > 1.5-2.0\,\text{octaves} > 1.5 − 2.0 octaves ): Providing acoustic amplification within an extensive high-frequency dead region causes speech degradation . Amplified energy stimulates off-frequency low-frequency channels, creating harmonic smearing and worsening word recognition scores compared to leaving the high frequencies unamplified.

Restricted Dead Regions ( < 1 octave < 1\,\text{octave} < 1 octave ): Modest amplification up to 1.5 × f e 1.5 \times f_e 1.5 × f e ​ (edge frequency) can yield modest speech benefits. Above this cut-off, gain must be rolled off, and the audiologist should implement frequency lowering technology to shift high-frequency speech cues into surviving lower-frequency cochlear zones.

High-Frequency Lowering Technologies

When high-frequency hearing loss is severe or dead regions are present, conventional amplification cannot restore audibility due to acoustic feedback limits and cochlear desensitization. Frequency lowering translocates inaudible high-frequency consonant cues (e.g., voiceless fricatives /s/, /z/, /f/, /θ/, and affricates /tʃ/) into lower, audible frequency regions. Frequency Lowering Paradigms:

1. Frequency Compression (NFC):

  • [ 0 kHz -------- Cutoff (2.5 kHz) ==(Compress 2:1)==> 6 kHz ]
  • (Squeezes all frequencies above cutoff into a compressed band)

2. Frequency Transposition:

  • [ Source: 4-6 kHz ] ==(Shift Down 1 Octave)==> [ Destination: 2-3 kHz ]
  • (Superimposes shifted source band on top of uncompressed audio)

3. Frequency Translation / Composition:

  • [ Detect High /s/ Energy ] ==(Synthesize / Copy)==> [ Inject into 1.5-2.5 kHz ]
  • (Injects spectral peak into lower band only when consonant is active)
  • 1. Nonlinear Frequency Compression (NFC)

Mechanics: All frequencies below a chosen start frequency (kneepoint/cutoff, e.g., 1.5 − 2.5 kHz 1.5-2.5\,\text{kHz} 1.5 − 2.5 kHz ) remain unprocessed and linear. Frequencies above the cutoff are compressed into a narrower high-frequency band at a selectable compression ratio ( 1.5 : 1 1.5:1 1.5 : 1 to 4 : 1 4:1 4 : 1 ).

Trade-off: Preserves all input spectral components, but warps harmonic relationships. Over-compression can cause the /s/ sound to be perceived as /ʃ/ ("sh"), causing patients to confuse "sail" and "shail."

2. Frequency Transposition

Mechanics: A designated high-frequency source band (e.g., 3 − 6 kHz 3-6\,\text{kHz} 3 − 6 kHz ) is shifted down by a fixed interval (e.g., one octave) and mixed directly on top of the lower destination frequency band without compressing the bandwidth.

Trade-off: Can cause spectral masking and intermodulation dissonance if transposed consonant energy collides with lower vowel formants.

3. Frequency Translation / Spectral Copying

Mechanics: High-frequency spectral peaks are detected in real time. The algorithm copies the consonant envelope and synthesizes a replica in an audible lower-frequency band, active only when high-frequency consonants are present.

Verification via Probe-Microphone Speech Mapping

Frequency lowering cannot be verified using standard pure-tone aided thresholds. The clinician must use calibrated real-ear speech mapping :

Present calibrated speech stimuli containing the phoneme /s/ (e.g., the recorded sentence "The standard is sixty-six").

Observe the spectral energy peak of the lowered /s/ on the real-ear display screen.

The /s/ peak must sit within the patient's residual audible dynamic range (above hearing threshold, below UCL), while maintaining acoustic separation from the lower-frequency /ʃ/ formant peak (typically centered at 2 − 2.5 kHz 2-2.5\,\text{kHz} 2 − 2.5 kHz ). If /s/ and /ʃ/ overlap, the start frequency must be raised or the compression ratio lowered.

Power BTE Fittings & Acoustic Feedback Management

Fitting severe-to-profound hearing loss requires instruments delivering high Maximum Power Output ( > 135 − 144 dB SPL > 135-144\,\text{dB SPL} > 135 − 144 dB SPL ) and high acoustic gain ( > 70 − 85 dB > 70-85\,\text{dB} > 70 − 85 dB ). At these intensities, acoustic feedback oscillation is the primary clinical obstacle.

Acoustic Feedback Physics

Acoustic feedback occurs when amplified sound escaping from the ear canal reaches the hearing aid microphone at an amplitude equal to or greater than the original input signal, with an in-phase relationship ( 0 ∘ 0^\circ 0 ∘ or integer multiples of 360 ∘ 360^\circ 36 0 ∘ ). This initiates a runaway oscillatory feedback loop, perceived as a high-pitched squeal.

Mechanical & Plumbing Requirements for Power Fittings

Earmold Material: Thick, soft medical-grade silicone or soft vinyl is mandatory. Silicone flexes with mandibular movement during chewing and talking, maintaining an airtight acoustic seal against the canal walls.

Canal Length & Bore: Long canal bore extending past the second canal bend into the bony canal aperture. This places the receiver discharge closer to the tympanic membrane, reducing the trapped ear canal volume ( V c V_c V c ​ ). Reducing canal volume from 2.0 cc 2.0\,\text{cc} 2.0 cc to 0.5 cc 0.5\,\text{cc} 0.5 cc increases sound pressure by + 6 − 12 dB +6-12\,\text{dB} + 6 − 12 dB for the same acoustic output, reducing the electronic gain required from the amplifier.

Sound Tubing: Thick-wall (#13 Thick) or double-wall (#13 Super Thick) vinyl tubing. Thin-walled tubing allows acoustic energy to radiate through the tubing walls into the microphone, causing feedback.

Venting: Unvented or pressure-vented ( 0.6 − 0.8 mm 0.6-0.8\,\text{mm} 0.6 − 0.8 mm ) molds only. Any vent ≥ 1.0 mm \ge 1.0\,\text{mm} ≥ 1.0 mm leaks high-level acoustic energy, triggering feedback in power fittings.

Acoustic Dampers: Sintered metal or cloth dampers ( 1500 − 2200 Ω 1500-2200\,\Omega 1500 − 2200 Ω ) inserted into the earhook smooth out sharp mechanical receiver resonance peaks ( 1.5 − 3 kHz 1.5-3\,\text{kHz} 1.5 − 3 kHz ), which are prime triggers for acoustic feedback.

Loading diagram... Clinical Decision Matrix for Asymmetric, Single-Sided Deafness, and Severe-to-Profound Fittings