1 Acoustics, Psychoacoustics & Sound Measurement

Physics of Sound, Wave Propagation & Decibel Scales (SPL, HL, SL) Psychoacoustics, Equal Loudness Contours & Frequency Selectivity Speech Acoustics, Formant Structure & Auditory Perception

2 Auditory and Vestibular Anatomy and Physiology

Peripheral Auditory System: Outer, Middle & Inner Ear Transduction Vestibular End Organs, Semicircular Canals & Otolith Mechanics Central Auditory Pathways, Neuroanatomy & Lifespan Structural Maturation Auditory Behavior, Speech-Language Development & Effects of Hearing Loss Across the Lifespan

3 Auditory Pathologies, Genetics & Instrumentation

Outer, Middle, and Inner Ear Pathologies & Genetic Syndromes Nongenetic Systemic Conditions & Infectious Causes of Hearing and Balance Disorders Ototoxic Medications, Pharmacology & Monitoring Protocols Audiometric Instrumentation, Calibration Standards (ANSI S3.6) & Psychometrics

4 Prevention, Lifespan Screening & Hearing Conservation

Universal Newborn Hearing Screening & JCIH Protocols Pediatric and School-Age Hearing Screening Procedures Adult and Geriatric Hearing Screening & Self-Assessment Measures Screening for Speech-Language, Cognitive & Other Conditions and Screening Program Performance Occupational Hearing Conservation, Noise Exposure & OSHA Regulations Hearing Health Education, Fall-Risk Identification & Audiometric and Balance Monitoring

5 Behavioral Pure-Tone Audiometry & Masking

Clinical Preparation: Case History, Otoscopy & Selecting and Modifying Tests Air and Bone Conduction Pure-Tone Testing & Audiogram Interpretation Clinical Masking Principles, Interaural Attenuation & Plateau Method Non-Organic Hearing Loss, Pseudohypacusis & Stenger Testing

6 Speech Audiometry & Pediatric Behavioral Evaluation

Speech Detection & Recognition Thresholds (SDT/SRT) & Word Recognition (WRS) Speech-in-Noise Testing, PB-Max & Retrocochlear Rollover Diagnostics Central Auditory Processing Assessment: Dichotic, Temporal, Spatial & Low-Redundancy Tests Pediatric Behavioral Audiometry: BOA, VRA, and CPA

7 Acoustic Immittance & Middle Ear Diagnostics

Tympanometric Principles, Jerger Classification & Eustachian Tube Function Acoustic Reflex Thresholds, Reflex Arc Pathways & Reflex Decay Analysis Multi-Frequency Immittance, High-Frequency Probe Tones & Infant Protocols

8 Otoacoustic Emissions & Auditory Evoked Potentials

Transient and Distortion Product Otoacoustic Emissions (TEOAE & DPOAE) Auditory Brainstem Response (ABR) Diagnostic Protocols & Wave Analysis ASSR, Electrocochleography (ECochG) & Late Auditory Evoked Potentials

9 Vestibular & Balance Assessment

Videonystagmography (VNG), Oculomotor Tracking & Positional Nystagmus Bithermal Caloric Testing, Jongkees Formula & Rotational Chair Evaluation Video Head Impulse Test (vHIT), VEMP (cVEMP/oVEMP) & Dynamic Posturography (CDP) Integrating Assessment Results, Differential Diagnosis & Reporting

10 Hearing Aid Selection, Features & Prescriptive Fitting

Treatment Planning, Goal Setting, Progress Monitoring & Intervention Documentation Hearing Aid Components, Acoustic Transducers & Digital Signal Processing Prescriptive Fitting Targets (NAL-NL2 vs. DSL m[i/o]) & Dynamic Range CROS, BiCROS & Severe-to-Profound Fitting Strategies

11 Amplification Verification, Validation & Troubleshooting

Probe-Microphone Real-Ear Verification (REUR, REAR, REIG & RECD) ANSI S3.22 Electroacoustic Analysis & Quality Control Standards Clinical Validation Inventories (COSI, APHAB, SSQ) & Device Troubleshooting

12 Implantable Devices & Hearing Assistive Technology

Bone-Conduction Systems (BAHS) & Active Middle Ear Implants Cochlear Implants: Candidacy, Telemetry, MAPping Parameters & ABI Systems Hearing Assistive Technology, FM/DM Classroom Systems & Telecoils

13 Aural Rehabilitation, Tinnitus & Vestibular Management

Adult and Pediatric Aural Rehabilitation & Communication Strategies Tinnitus Management, Sound Therapy & Decreased Sound Tolerance Protocols Canalith Repositioning Maneuvers for BPPV & Vestibular Rehabilitation Therapy (VRT)

14 Ethics, Scope of Practice & Interprofessional Collaboration

ASHA and AAA Codes of Ethics, Ethical Decision-Making & Conflict of Interest Clinical Scope of Practice, CCC-A Credentialing, Licensure & Clinical Supervision Service Delivery Models, Practice Management, Risk Management & Advocacy Patient/Family Counseling & Interprofessional Practice in Education and Healthcare

15 Regulatory Compliance, Safety & Evidence-Based Practice

Federal Regulations (HIPAA, FERPA, ADA, OSHA), Billing Compliance & Infection Control Evidence-Based Practice, Research Methodology & Teleaudiology Service Delivery

Speech Detection & Recognition Thresholds (SDT/SRT) & Word Recognition (WRS)

Key Takeaways Explain This Topic AI

The Speech Detection Threshold (SDT/SAT) quantifies the lowest level at which speech is detected 50% of the time, agreeing within ± 5 dB \pm 5\,\text{dB} ± 5 dB of the best pure-tone threshold in the 250 − 1000 Hz 250-1000\,\text{Hz} 250 − 1000 Hz range.

The Speech Recognition Threshold (SRT) utilizes familiarized spondaic words to establish the 50% identification threshold, which must agree within ± 6 − 8 dB \pm 6-8\,\text{dB} ± 6 − 8 dB of the 3-frequency PTA or Fletcher 2-frequency average.

Discrepancies where the SRT is > 10 dB > 10\,\text{dB} > 10 dB better than the PTA strongly flag pseudohypacusis (non-organic hearing loss), whereas an SRT > 10 dB > 10\,\text{dB} > 10 dB worse than the PTA indicates central, cognitive, language, or retrocochlear pathology.

Word Recognition Scores (WRS) evaluate suprathreshold phoneme clarity using phonetically or phonemically balanced monosyllables (NU-6, CID W-22, PBK-50), with calibrated recorded speech representing the clinical gold standard over monitored live voice (MLV).

Clinical differences between word recognition percentages must be evaluated against binomial distribution statistics (Thornton-Raffin 95% critical difference tables) to avoid misattributing random sampling variability to true pathological change.

Last updated: October 2026

Speech Detection, Speech Recognition & Word Recognition Diagnostics

Speech audiometry constitutes an indispensable pillar of the comprehensive audiological evaluation. While pure-tone audiometry defines auditory sensitivity across discrete frequencies, speech stimuli evaluate the auditory system's capacity to detect, recognize, and resolve complex acoustic signals that carry human linguistic communication. A rigorous, doctoral-level understanding of speech audiometric protocols, psychometric validation, transducer acoustics, and masking equations is essential for identifying non-organic hearing loss, estimating hearing aid candidacy, and pinpointing retrocochlear or central auditory nervous system dysfunction.

Speech Detection Threshold (SDT) / Speech Awareness Threshold (SAT)

The Speech Detection Threshold (SDT) —synonymously termed the Speech Awareness Threshold (SAT) —is defined as the lowest intensity level, expressed in dB HL \text{dB HL} dB HL , at which a listener can just detect the physical presence of a speech signal 50 % 50\% 50% of the time. Unlike speech recognition procedures, the SDT requires zero linguistic decoding, lexical identification, or repetition of the stimulus; the patient merely indicates awareness that vocal acoustic energy is present.

Clinical Stimuli & Presentation Methodology

Continuous Discourse (Cold Running Speech): Rapid, uninflected narration delivered with uniform acoustic energy (peaking at 0 VU 0\,\text{VU} 0 VU on the volume unit meter) is the preferred stimulus. Connected discourse provides a continuous, redundant acoustic signal that facilitates rapid threshold convergence.

Pediatric & Non-Verbal Tokens: For infants, toddlers, or non-verbal adult populations, familiar vocalizations—such as the patient's own name, repeated syllables (e.g., "ba-ba-ba"), or melodic vocal play—are effectively employed.

Response Modalities: Standard behavioral responses include hand raising, button pressing, head turning, cessation of activity, or widening of the eyes (in pediatric behavioral observation).

Audiometric Cross-Check & Correlation with Pure-Tone Thresholds

The primary clinical purpose of the SDT is to serve as an independent biological validation of the pure-tone audiogram. Speech is a broadband signal, and speech detection is dictated by the frequency region of greatest hearing sensitivity within the core speech spectrum.

The ± 5 dB \pm 5\,\text{dB} ± 5 dB Rule: The SDT must agree within ± 5 dB \pm 5\,\text{dB} ± 5 dB of the best (lowest) pure-tone threshold obtained between 250 Hz 250\,\text{Hz} 250 Hz and 1000 Hz 1000\,\text{Hz} 1000 Hz (most commonly 250 Hz 250\,\text{Hz} 250 Hz or 500 Hz 500\,\text{Hz} 500 Hz ).

Clinical Example: If a patient presents with a precipitous high-frequency sensorineural hearing loss demonstrating thresholds of 20 dB HL 20\,\text{dB HL} 20 dB HL at 250 Hz 250\,\text{Hz} 250 Hz , 25 dB HL 25\,\text{dB HL} 25 dB HL at 500 Hz 500\,\text{Hz} 500 Hz , 60 dB HL 60\,\text{dB HL} 60 dB HL at 1000 Hz 1000\,\text{Hz} 1000 Hz , and 85 dB HL 85\,\text{dB HL} 85 dB HL at 2000 − 4000 Hz 2000-4000\,\text{Hz} 2000 − 4000 Hz , the expected SDT is between 15 dB HL 15\,\text{dB HL} 15 dB HL and 25 dB HL 25\,\text{dB HL} 25 dB HL (tracking the 20 dB HL 20\,\text{dB HL} 20 dB HL threshold at 250 Hz 250\,\text{Hz} 250 Hz ).

Primary Indications: The SDT is indicated when a patient cannot perform speech recognition tasks due to chronological age (infants < 12 − 18 months < 12-18\,\text{months} < 12 − 18 months ), developmental delay, profound intellectual disability, severe expressive/receptive aphasia, cognitive impairment, or severe language barriers.

Speech Recognition Threshold (SRT)

The Speech Recognition Threshold (SRT) —historically termed the Speech Reception Threshold—is defined as the lowest intensity level in dB HL \text{dB HL} dB HL at which an individual can correctly repeat or identify 50 % 50\% 50% of spondaic words from a closed or open set.

Spondee Words & Acoustic Characteristics

Definition of a Spondee: A two-syllable word pronounced with equal vocal effort, stress, and duration on both syllables (spondaic meter: / -- -- /). Examples include: baseball, hotdog, airplane, cowboy, ice cream, cupcake, railroad, toothbrush, sidewalk, sunset, mousetrap, northwest .

Psychometric Function Steepness: Spondees possess an exceptionally steep psychometric performance-intensity function, rising at approximately 10 % 10\% 10% to 12 % 12\% 12% per decibel near threshold. Because of this steep slope, the transition from 0 % 0\% 0% to 100 % 100\% 100% recognition occurs within a narrow 10 − 12 dB 10-12\,\text{dB} 10 − 12 dB window, rendering the 50 % 50\% 50% threshold remarkably reliable and repeatable within ± 5 dB \pm 5\,\text{dB} ± 5 dB .

Carrier Phrase Rules: A carrier phrase ("Say the word...") is optional for SRT testing. When utilized, the carrier phrase must be peaked at 0 VU 0\,\text{VU} 0 VU on the audiometer's volume unit meter, and both syllables of the spondee must independently peak at 0 VU 0\,\text{VU} 0 VU . However, modern clinical guidelines frequently omit the carrier phrase during SRT determination to accelerate testing without sacrificing test-retest reliability.

Spondee Familiarization Protocol

Familiarization is an absolute, non-negotiable prerequisite of standard SRT testing (ASHA, 1988). The clinician presents a list of spondees suprathreshold (typically at + 30 +30 + 30 to + 40 dB SL +40\,\text{dB SL} + 40 dB SL above estimated threshold or at a comfortably loud listening level) through the test transducer.

Aims of Familiarization:

Confirms that the target words exist in the patient's active vocabulary.

Ensures the patient can accurately execute the motor speech production required to repeat each word intelligibly.

Clarifies the patient's idiosyncratic pronunciation patterns so the clinician can score responses accurately.

Reduces vocabulary uncertainty, shifting the task from an open-set lexical search to a closed-set recognition task, thereby sharpening psychometric slope.

Exclusion Criteria: Any word that the patient fails to recognize, hesitates over, or cannot repeat correctly during suprathreshold familiarization is permanently removed from the test set for that patient.

Threshold Search Procedures: Hughson-Westlake vs. ASHA (1988)

Two primary protocols are utilized to determine the SRT:

Modified Hughson-Westlake (Ascending) Method: Adapted from pure-tone audiometry. The clinician introduces a spondee below estimated threshold and ascends in 5 dB 5\,\text{dB} 5 dB steps until a correct response is given, then descends 10 dB 10\,\text{dB} 10 dB ("down 10, up 5"). The threshold is the lowest dial setting at which the patient correctly repeats at least 3 out of 6 words (or 50 % 50\% 50% of presentations).

ASHA (1988) Descending Protocol: A standardized statistical procedure designed to eliminate clinician bias. Testing begins at a suprathreshold level where the patient correctly repeats several words. The level is decreased in fixed steps ( 2 dB 2\,\text{dB} 2 dB or 5 dB 5\,\text{dB} 5 dB decrements), presenting a fixed number of spondees per level down to the point where the patient misses all words. The threshold is calculated via a mathematical formula: SRT = Starting Level − Total Correct Words + Correction Factor \text{SRT} = \text{Starting Level} - \text{Total Correct Words} + \text{Correction Factor} SRT = Starting Level − Total Correct Words + Correction Factor For the 5 dB 5\,\text{dB} 5 dB -step version (5 words per level), the ASHA formula is the starting level minus the total words correct plus a 2 dB 2\,\text{dB} 2 dB correction factor.

The SRT-PTA Agreement Check & Clinical Discrepancy Analysis

The most fundamental quality-control metric in clinical audiometry is the comparison between the SRT and the Pure-Tone Average (PTA). Because speech acoustics encompass energy across the mid-frequency spectrum, speech thresholds must biologically track pure-tone thresholds.

Standard 3-Frequency PTA vs. Fletcher Two-Frequency Average

Standard 3-Frequency PTA: The arithmetic mean of air-conduction thresholds at 500 Hz 500\,\text{Hz} 500 Hz , 1000 Hz 1000\,\text{Hz} 1000 Hz , and 2000 Hz 2000\,\text{Hz} 2000 Hz : PTA 3 = AC 500 + AC 1000 + AC 2000 3 \text{PTA}_3 = \frac{\text{AC}_{500} + \text{AC}_{1000} + \text{AC}_{2000}}{3} PTA 3 ​ = 3 AC 500 ​ + AC 1000 ​ + AC 2000 ​ ​

Acceptable Agreement: In flat or gently sloping configurations, the SRT must agree with the 3-frequency PTA within ± 6 dB \pm 6\,\text{dB} ± 6 dB (clinically acceptable within ± 8 − 10 dB \pm 8-10\,\text{dB} ± 8 − 10 dB ).

Fletcher Two-Frequency Average: When pure-tone thresholds slope steeply (defined as an inter-octave threshold disparity ≥ 20 dB \ge 20\,\text{dB} ≥ 20 dB between adjacent speech frequencies), the 3-frequency PTA artificially overestimates the degree of speech handicap. Under these circumstances, the audiologist must calculate the Fletcher average—the arithmetic mean of the best two thresholds among 500 500 500 , 1000 1000 1000 , and 2000 Hz 2000\,\text{Hz} 2000 Hz (most often 500 Hz 500\,\text{Hz} 500 Hz and 1000 Hz 1000\,\text{Hz} 1000 Hz ): PTA Fletcher = Best AC Frequency + Second Best AC Frequency 2 \text{PTA}_{\text{Fletcher}} = \frac{\text{Best AC Frequency} + \text{Second Best AC Frequency}}{2} PTA Fletcher ​ = 2 Best AC Frequency + Second Best AC Frequency ​ The SRT will consistently agree within ± 6 dB \pm 6\,\text{dB} ± 6 dB of the Fletcher average rather than the 3-frequency PTA.

Clinical Diagnostic Discrepancies

When the SRT and PTA demonstrate a discrepancy exceeding 10 − 12 dB 10-12\,\text{dB} 10 − 12 dB , the discrepancy represents a major diagnostic red flag requiring immediate investigation.

Discrepancy Pattern Quantitative Finding Primary Etiologies & Mechanisms Mandatory Clinical Actions

SRT Much Better than PTA SRT < PTA − 10 dB \text{SRT} < \text{PTA} - 10\,\text{dB} SRT < PTA − 10 dB Pseudohypacusis (Non-Organic / Functional Loss): Spondaic words possess high acoustic redundancy; malingering patients establish a loudness reference for spondees that is closer to their true organic threshold than their feigned pure tones. Administer Stenger test immediately (if asymmetry ≥ 20 dB \ge 20\,\text{dB} ≥ 20 dB ); re-instruct patient; obtain objective DPOAEs and diagnostic ABR.

SRT Much Worse than PTA SRT > PTA + 10 dB \text{SRT} > \text{PTA} + 10\,\text{dB} SRT > PTA + 10 dB Retrocochlear Pathology / ANSD: Eighth nerve desynchronization degrades complex word timing while pure tones remain detectable; Central Auditory Processing Disorder (CAPD): Deficits in auditory closure and integration; Cognitive / Language Factors: Receptive aphasia, non-native English speaker, severe articulation deficits. Evaluate acoustic reflexes and reflex decay; perform PIPB rollover testing; evaluate OAEs vs. ABR for Auditory Neuropathy Spectrum Disorder; obtain cognitive/speech-language consult.

Word Recognition Testing (WRS / SDS)

Word Recognition Score (WRS) —historically termed Speech Discrimination Score (SDS)—is a suprathreshold, supraliminal test that quantifies the percentage of phonetically or phonemically balanced monosyllabic words correctly identified and repeated at a fixed, comfortable, or optimal presentation level.

Standardized Monosyllabic Word Lists

Monosyllabic test lists are meticulously constructed so that the distribution of phonemes within each list matches the relative frequency of phonemes occurring in conversational English.

CID W-22 (Central Institute for the Deaf): Developed by Hirsh et al. Comprises four 50-word lists. Words are phonetically balanced and represent highly familiar, everyday adult vocabulary. Because the vocabulary is simple, CID W-22 functions are slightly less difficult and exhibit slightly shallower slopes than NU-6.

NU-6 (Northwestern University Auditory Test No. 6): Developed by Tillman and Carhart. Comprises four 50-word lists arranged in four randomizations. Lists are constructed around consonant-nucleus-consonant (CNC) monosyllabic words built from the consonant-nucleus-consonant word lists of Lehiste and Peterson. NU-6 is the contemporary standard for adult audiological assessment and retrocochlear rollover diagnostics.

PBK-50 (Phonetically Balanced Kindergarten): Formulated by Haskins. Comprises three 50-word lists with linguistic and lexical items selected from kindergarten-level spoken vocabularies. Designed for pediatric patients (developmental age 5 − 7 years 5-7\,\text{years} 5 − 7 years ) or adult patients with significant intellectual disabilities or restricted vocabularies.

Presentation Modality: Recorded Speech vs. Monitored Live Voice (MLV)

Parameter Calibrated Recorded Speech (Compact Disc / Digital Audio) Monitored Live Voice (MLV)

Acoustic Standardization Rigorously controlled; 1000 Hz 1000\,\text{Hz} 1000 Hz calibration tone establishes exact 0 VU 0\,\text{VU} 0 VU level. Extremely variable; impossible to maintain exact 0 VU 0\,\text{VU} 0 VU across all speech tokens.

Examiner Dialect & Vocal Inflection Completely standardized; identical acoustic waveform across test sessions. Vulnerable to examiner fatigue, dialect, co-articulation shifts, and pitch drift.

Test-Retest Reliability High; statistical models (Thornton-Raffin) strictly hold. Poor; inter-examiner and intra-examiner test differences frequently exceed 15 − 20 % 15-20\% 15 − 20% .

Flexibility & Pacing Fixed pause intervals; can be paused manually between items. Highly flexible; can adapt timing instantly to slow, pediatric, or confused patients.

Visual Cues Auditory-only signal delivered via transducer; eliminates lipreading. Examiner must cover mouth or test outside booth to eliminate visual/facial cues.

Clinical Practice Standard The Gold Standard (ANSI / AAA / ASHA recommended). Mandatory for medicolegal, research, and rollover assessments. Permissible only for fragile, elderly, or young pediatric patients unable to tolerate recorded pacing.

Carrier Phrase & Presentation Level Optimization

Carrier Phrase Requirement: For monosyllabic word recognition testing, the carrier phrase "Say the word..." must precede every test item. The carrier phrase serves two vital functions: (1) it alerts the patient to prepare for the test token, and (2) it provides an acoustic calibration anchor, allowing the clinician (under MLV) to monitor and peak their voice at 0 VU 0\,\text{VU} 0 VU , permitting the subsequent test word to fall naturally with conversational stress.

Presentation Level Strategies:

Standard Suprathreshold Level: Routinely administered at + 30 dB SL +30\,\text{dB SL} + 30 dB SL to + 40 dB SL +40\,\text{dB SL} + 40 dB SL relative to the patient's SRT, ensuring the acoustic tokens are delivered with sufficient audibility to overcome threshold loss.

Conversational Speech Level: Administered at fixed levels of 60 dB HL 60\,\text{dB HL} 60 dB HL to 65 dB HL 65\,\text{dB HL} 65 dB HL to evaluate communication performance under typical real-world listening dynamics.

PB-Max Search: Administered at high levels (e.g., 80 − 90 dB HL 80-90\,\text{dB HL} 80 − 90 dB HL or UCL − 5 dB \text{UCL} - 5\,\text{dB} UCL − 5 dB ) to determine the patient's maximum speech resolution ceiling for amplification fitting and rollover evaluation.

Binomial Distribution & The Thornton-Raffin Critical Difference Tables

A critical competency for the clinical audiologist is determining whether a percentage change in word recognition represents a true biological shift (e.g., progressive retrocochlear lesion, ototoxic decline, or true hearing aid benefit) or merely random statistical sampling error.

The Binomial Nature of Speech Recognition

Word recognition testing consists of n n n independent, binary trials (the patient repeats the word either correctly or incorrectly ). Consequently, test scores follow a binomial distribution , not a continuous Gaussian distribution. The standard error ( σ \sigma σ ) of a proportion p p p based on n n n test words is expressed mathematically as: σ = p ( 1 − p ) n \sigma = \sqrt{\frac{p(1 - p)}{n}} σ = n p ( 1 − p ) ​ ​ Because variance is inversely proportional to list length ( n n n ):

50-Word Lists: Provide narrower confidence intervals and substantially higher statistical power.

25-Word (Half) Lists: Exhibit dramatically wider confidence intervals. A 25-word list doubles binomial variance, increasing the probability of false-positive and false-negative clinical decisions.

Thornton & Raffin (1978) Critical Difference Model

Thornton and Raffin established 95 % 95\% 95% critical difference confidence intervals defining the exact range within which a second test score must fall to be considered statistically equivalent to the first score ( p > 0.05 p > 0.05 p > 0.05 ).

Initial Score (% Correct) 95% Critical Difference Range: 50-Word List 95% Critical Difference Range: 25-Word List

  • 100 % 100\% 100% 96 % − 100 % 96\% - 100\% 96% − 100% 92 % − 100 % 92\% - 100\% 92% − 100%
  • 92 % 92\% 92% 78 % − 98 % 78\% - 98\% 78% − 98% 72 % − 100 % 72\% - 100\% 72% − 100%
  • 80 % 80\% 80% 64 % − 92 % 64\% - 92\% 64% − 92% 56 % − 96 % 56\% - 96\% 56% − 96%
  • 68 % 68\% 68% 50 % − 84 % 50\% - 84\% 50% − 84% 44 % − 88 % 44\% - 88\% 44% − 88%
  • 60 % 60\% 60% 42 % − 78 % 42\% - 78\% 42% − 78% 36 % − 84 % 36\% - 84\% 36% − 84%

Scores on a 25-word list move in 4% steps, so the table uses initial scores that are possible on both list lengths (values from Thornton and Raffin's 1978 tables).

Clinical Interpretation Rule: If a patient obtains an initial score of 80 % 80\% 80% on a 25-word list, a follow-up score must drop below 56 % 56\% 56% or rise to 100 % 100\% 100% before an audiologist can conclude with 95 % 95\% 95% statistical confidence that a true change in auditory capability has occurred. An apparent drop from 80 % 80\% 80% to 64 % 64\% 64% on a 25-word list is entirely attributable to binomial sampling error.

Clinical Masking for Speech Audiometry

Whenever high-intensity speech energy is delivered to a test ear, the acoustic signal can cross the cranial vault via bone conduction and stimulate the contralateral, non-test cochlea. Contralateral masking is required to prevent cross-hearing from creating an invalid, shadow speech result.

Interaural Attenuation (IA) for Speech Stimuli

Supra-Aural Headphones (TDH-39 / TDH-49): IA = 40 dB \text{IA} = 40\,\text{dB} IA = 40 dB .

Insert Earphones (ER-3A / ER-5A): IA = 60 dB \text{IA} = 60\,\text{dB} IA = 60 dB .

Speech Masking Rules

Masking Rule for SRT: Contralateral masking is mandatory whenever the SRT of the test ear (TE) minus interaural attenuation equals or exceeds the best (lowest) bone-conduction threshold of the non-test ear (NTE) across the speech range ( 500 500 500 , 1000 1000 1000 , or 2000 Hz 2000\,\text{Hz} 2000 Hz ): SRT TE − IA ≥ Best BC NTE \text{SRT}_{\text{TE}} - \text{IA} \ge \text{Best } \text{BC}_{\text{NTE}} SRT TE ​ − IA ≥ Best BC NTE ​

Initial Masker Level ( M initial M_{\text{initial}} M initial ​ ): M initial = SRT TE − IA + Largest ABG NTE + 10 dB Safety Margin M_{\text{initial}} = \text{SRT}_{\text{TE}} - \text{IA} + \text{Largest } \text{ABG}_{\text{NTE}} + 10\,\text{dB Safety Margin} M initial ​ = SRT TE ​ − IA + Largest ABG NTE ​ + 10 dB Safety Margin Alternatively, presenting Speech Noise at SRT NTE + 10 dB \text{SRT}_{\text{NTE}} + 10\,\text{dB} SRT NTE ​ + 10 dB provides effective initial masking when the non-test ear has no conductive air-bone gap.

Masking Rule for Word Recognition Scores (WRS): Because word recognition is administered at suprathreshold levels ( + 30 +30 + 30 to + 40 dB SL +40\,\text{dB SL} + 40 dB SL ), the risk of cross-hearing is substantially elevated. Masking is mandatory whenever the speech presentation level ( P L TE PL_{\text{TE}} P L TE ​ ) minus interaural attenuation equals or exceeds the best bone-conduction threshold of the non-test ear in the speech frequency range: P L TE − IA ≥ Best BC NTE PL_{\text{TE}} - \text{IA} \ge \text{Best } \text{BC}_{\text{NTE}} P L TE ​ − IA ≥ Best BC NTE ​

Masking Stimulus: Speech Noise vs. White Noise

Speech-Shaped Noise (Speech Noise): The internationally standardized masking stimulus for speech audiometry (ANSI S3.6). Speech Noise is a broadband noise filtered to match the Long-Term Average Speech Spectrum (LTASS) . It exhibits a uniform, flat energy distribution from 100 Hz 100\,\text{Hz} 100 Hz to 1000 Hz 1000\,\text{Hz} 1000 Hz , followed by a steep − 12 dB -12\,\text{dB} − 12 dB per octave roll-off at frequencies above 1000 Hz 1000\,\text{Hz} 1000 Hz .

Acoustic Superiority: Speech Noise concentrates its acoustic masking power precisely in the spectral bandwidth where speech energy is greatest. Using White Noise (equal energy per Hertz) or Pink Noise ( − 3 dB/octave -3\,\text{dB/octave} − 3 dB/octave ) is acoustically inefficient, requiring excessive overall sound pressure levels that cause premature overmasking and patient discomfort.

Loading diagram... Clinical SRT-PTA Agreement Decision Hierarchy and Discrepancy Diagnostics