Study guide

2.2 Data Collection, Measurement, and Lab Safety

Praxis Biology Content Knowledge 5235/5236

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Introduction & Exam Overview

1.1 Current Exam Facts 1.2 How to Use This Guide

2 Chapter 2: Nature of Science

2.1 Scientific Method and Experimental Design 2.2 Data Collection, Measurement, and Lab Safety 2.3 Data Analysis and Graphing 2.4 History and Philosophy of Biology 2.5 Pedagogy: Teaching Inquiry-Based Biology 2.6 Engineering Design and the Science-Technology Interdependence 2.7 Science, Society, and Bioethics: Biotechnology, Health, and the Environment

3 Chapter 3: Cell Biology

3.1 Biological Molecules 3.2 Cell Structure: Prokaryotic vs Eukaryotic 3.3 Membrane Transport 3.4 Cellular Respiration and Photosynthesis 3.5 Cell Cycle, Mitosis, Meiosis 3.6 Cell Signaling and Communication

4 Chapter 4: Genetics & Evolution

4.1 DNA Structure, Replication, and Repair 4.2 Transcription, Translation, and the Genetic Code 4.3 Mendelian Genetics and Inheritance 4.4 Molecular Genetics and Biotechnology 4.5 Mechanisms of Evolution 4.6 Evidence for Evolution and Phylogeny

5 Chapter 5: Diversity of Life

5.1 Taxonomy and Classification 5.2 Bacteria, Archaea, and Viruses 5.3 Protists and Fungi 5.4 Plant Diversity, Structure, and Reproduction 5.5 Animal Diversity and Body Plans 5.6 Animal Organ Systems Overview

6 Chapter 6: Ecology

6.1 Population Ecology 6.2 Community Ecology and Species Interactions 6.3 Ecosystem Ecology and Biogeochemistry 6.4 Biomes and Biodiversity 6.5 Conservation, Human Impacts, and Climate Change

2.2 Data Collection, Measurement, and Lab Safety

Key Takeaways Explain This Topic AI

SI units (meter, kilogram, second, kelvin, mole, ampere, candela) are the standard measurement system; biology most often uses meters, grams, liters, seconds, and degrees Celsius.

Accuracy is closeness to the true value; precision is repeatability among measurements. A measurement can be precise without being accurate.

A serial dilution multiplies the dilution factor at each step: a 1:10 serial dilution across four tubes yields concentrations of 10^-1, 10^-2, 10^-3, and 10^-4 of the stock.

GHS pictograms (flame, skull-and-crossbones, biohazard, corrosion, exclamation mark) and Safety Data Sheets (SDS) Section 4 (first aid) and Section 8 (PPE) drive emergency response in the classroom lab.

Total magnification of a compound light microscope equals objective magnification times eyepiece magnification (typically 10x); resolution is limited by wavelength and is roughly 200 nm for light, 0.2 nm for transmission electron microscopy.

Last updated: May 2026

Why This Section Matters

ETS expects a Praxis Biology candidate to walk into a classroom on Day 1 and run a safe, quantitative lab. Subarea I items routinely test SI units, dilution math, Safety Data Sheet (SDS) literacy, and microscope operation. Mistakes here are also the most common cause of serious incident reports in school science labs, so the knowledge has direct professional consequence.

SI Units in Biology

The International System of Units (SI) is the metric system used worldwide in science.

  • Quantity SI Base Unit Common Biology Examples
  • Length meter (m) seedling height in cm; cell diameter in micrometers (mum)
  • Mass kilogram (kg) organism mass in grams (g) or milligrams (mg)
  • Time second (s) reaction time in s or min
  • Temperature kelvin (K) usually reported in degrees C; K = degrees C + 273.15
  • Amount of substance mole (mol) molarity in mol/L (M)
  • Volume (derived) cubic meter (m^3) typically liters (L) or milliliters (mL)

Useful prefixes: kilo- (10^3), centi- (10^-2), milli- (10^-3), micro- (10^-6), nano- (10^-9) . Cell biology lives mostly in mum and nm; molecular work lives in nM to mM.

Accuracy vs. Precision

Accuracy = closeness to the true value. An archer hitting the bullseye is accurate.

Precision = closeness of repeated measurements to each other . An archer who clusters all arrows in the same off-center spot is precise but inaccurate.

Systematic error (an uncalibrated balance always reading 2 g high) damages accuracy.

Random error (small fluctuations in technique) damages precision.

You can be precise without being accurate, but you cannot be reliably accurate without precision.

Significant Figures

A measurement should be reported with all digits known with certainty plus one estimated digit . A ruler marked in millimeters lets you estimate to about 0.1 mm. When multiplying or dividing, the answer carries the same number of significant figures as the least-precise input (e.g., 4.56 cm x 2.1 cm = 9.6 cm^2, not 9.576 cm^2).

Dilutions and Serial Dilutions

The core dilution formula is:

C_1 x V_1 = C_2 x V_2

where C is concentration and V is volume; subscript 1 is stock, subscript 2 is the diluted solution. Example: to make 100 mL of 0.1 M NaCl from a 1.0 M stock, V_1 = (0.1 x 100) / 1.0 = 10 mL stock, topped up to 100 mL with water.

A serial dilution chains identical dilution steps to span many orders of magnitude — essential for plating bacterial cultures, enzyme kinetics, and standard curves.

  • Tube Action Resulting Concentration (relative to stock)
  • 1 1 mL stock + 9 mL water 10^-1 (1:10)
  • 2 1 mL from Tube 1 + 9 mL water 10^-2 (1:100)
  • 3 1 mL from Tube 2 + 9 mL water 10^-3 (1:1,000)
  • 4 1 mL from Tube 3 + 9 mL water 10^-4 (1:10,000)

Always change pipette tips between tubes to prevent carryover.

  • Lab Safety Essentials
  • Safety Data Sheets (SDS, formerly MSDS)

A Safety Data Sheet is a 16-section document, mandated by OSHA's Hazard Communication Standard, that accompanies every chemical purchased for the lab. The standardized sections you must be able to navigate:

  • Section 4 - First-aid measures (what to do if exposed)
  • Section 6 - Accidental release (spill cleanup)
  • Section 7 - Handling and storage
  • Section 8 - Exposure controls / PPE
  • Section 10 - Stability and reactivity (incompatibilities)

The SDS file must be accessible to students during a lab activity, not locked in an office.

GHS Pictograms

The Globally Harmonized System (GHS) uses red-bordered diamond pictograms to label chemical containers:

  • Flame - flammable
  • Flame over circle - oxidizer
  • Exploding bomb - explosive
  • Skull and crossbones - acute toxicity (fatal/toxic)
  • Corrosion - corrosive to metal or skin
  • Exclamation mark - irritant, harmful (lower severity)
  • Health hazard - carcinogen, mutagen, reproductive toxin
  • Environment - aquatic toxicity (non-mandatory in the U.S.)

The biohazard symbol (three-crescent trefoil, orange/black) is a separate biosafety marking — not a GHS pictogram.

Personal Protective Equipment (PPE)

Minimum PPE for a wet biology lab: chemical splash goggles, lab apron or coat, closed-toe shoes, nitrile gloves . Add a fume hood for volatile solvents, a face shield for high-splash work, and a respirator only with documented training and fit testing.

Biosafety Levels (BSL)

Level Hazard Class Typical Organisms Containment

BSL-1 No known disease in healthy adults E. coli K-12, Bacillus subtilis, baker's yeast Standard microbiology, open bench

BSL-2 Moderate, transmitted by ingestion/percutaneous S. aureus, Salmonella, hepatitis viruses Biosafety cabinet for aerosols, restricted access

BSL-3 Serious or potentially lethal, respiratory transmission M. tuberculosis, SARS-CoV-2, Bacillus anthracis Negative-pressure room, PPE incl. respirator

BSL-4 Life-threatening, no treatment/vaccine Ebola virus, Marburg virus Full positive-pressure suit, dedicated facility

High-school biology labs operate at BSL-1 ; teacher candidates should know they are not authorized to culture unknown bacteria from environmental swabs, because the resulting colonies cannot be guaranteed BSL-1.

Required Engineering Controls

Eyewash station capable of 15 minutes of continuous tepid water; tested weekly.

Safety shower within 10 seconds of any chemical-handling area.

Fire blanket and ABC extinguisher within easy reach.

Sharps container (rigid, puncture-resistant, labeled with biohazard symbol) for scalpels, needles, broken glass.

Chemical Hygiene Plan (CHP) — written, school-specific document required by OSHA 29 CFR 1910.1450; updated annually.

Microscopy Basics

A compound light microscope uses visible light passing through two lens systems: the objective (4x, 10x, 40x, 100x oil-immersion) and the ocular/eyepiece (typically 10x).

Total magnification = objective magnification x eyepiece magnification.

At 40x objective with a 10x eyepiece, total magnification is 400x .

Magnification is how much bigger the image appears.

Resolution is the smallest distance between two points still seen as separate. Light microscopy is limited by the wavelength of visible light to about 200 nanometers (0.2 mum) . Increasing magnification beyond this point gives "empty magnification" — bigger but blurrier.

Transmission electron microscopy (TEM) uses electron beams (wavelength about 0.005 nm) and can resolve features about 0.2 nm , revealing ribosomes, viruses, and membrane bilayers. Specimens must be dead, fixed, and sectioned.

Scanning electron microscopy (SEM) produces a 3D surface image with about 10 nm resolution.

Microscope Operating Reminders

Always start on the lowest-power objective and focus with the coarse adjustment.

Switch to higher objectives using only the fine adjustment.

Carry the microscope with one hand on the arm and one hand under the base .

Clean objective lenses only with lens paper (never paper towel).

Park on the lowest-power objective and lower the stage before storing.