Study guide
5.6 Bases, Liners, Matrices, and Wedges
California RDA Study Guide Exam
Track your progress as you read
Finished sections get a check mark.
1 Orientation: California RDA Licensure, Pathways, Fees, Eligibility, and PSI
1.1 California RDA Exam Identity 1.2 Application, Fee, Processing, and File Control 1.3 Approved Pathways and Documentation 1.4 Required Courses and BLS Evidence 1.5 Fingerprints, Background Review, and License Issuance 1.6 PSI Authorization, Name and ID Matching, and Two-Year Deadline
2 Current RDA Exam Format: OPES Update, Passing Standard, Results, and Retakes
2.1 Current Format After the OPES Update 2.2 Three-Hour Pacing and Item Stamina 2.3 Criterion-Referenced Passing Standard 2.4 Pass/Fail Results and No Actual Score 2.5 Retake Eligibility and Rescheduling 2.6 Outline Weights and Study Priorities
3 Assessment and Diagnostic Records I: Patient History, Vitals, and Oral Assessment
3.1 Domain 1A Role and Record Flow 3.2 Medical History Review and Risk Cues 3.3 Medications, Allergies, and Sensitivities 3.4 Premedication and Medical Consult Cues 3.5 Blood Pressure, Pulse, and Vital Signs 3.6 Oral Assessment, Mouth Mirror, and Basic Structures
4 Assessment and Diagnostic Records II: Diagnostic Tests, Imaging, CBCT, and Charting
4.1 Domain 1B Diagnostic Records Overview 4.2 Caries Detection Support and Recording 4.3 Intraoral Imaging for CAD Restorations 4.4 Radiographs, CBCT, Positioning, and Safety 4.5 Patient Management During Imaging 4.6 Charting Terminology, Universal, and Palmer
5 Dental Procedures I: Treatment Preparation, Instruments, Isolation, Bases, and Matrices
5.1 Treatment Stages and Exam Positioning 5.2 Tray and Equipment Setup 5.3 Instruments and Chairside Transfer 5.4 Materials, Components, Working Time, and Readiness 5.5 Isolation, Evacuation, and Field Control 5.6 Bases, Liners, Matrices, and Wedges
6 Dental Procedures II: Restorations, Provisionals, Cements, and Nitrous Oxide Support
6.1 Restoration Workflow and Exam Positioning 6.2 Temporary Fillings and Interim Restorative Support 6.3 Etchants, Bonding Agents, and Moisture Control 6.4 Direct and Indirect Provisionals 6.5 Margins, Contacts, Occlusion, and Excess Cement 6.6 Nitrous Oxide/Oxygen Support Under Dentist Order
7 Dental Procedures III: Preventive, Aesthetic, Patient Education, and Specialty Procedures
7.1 Domain 2C-2E Preventive, Education, and Specialty Map 7.2 Coronal Polishing Workflow and Patient Safety 7.3 Pit and Fissure Sealants: Isolation, Etching, and Evaluation 7.4 Bleaching and Aesthetic Support Instructions 7.5 Patient Education: Oral Hygiene, Diet, and Home Care 7.6 Specialty Procedure Support: Endodontic, Periodontal, Orthodontic, Surgical, and Prosthetic
8 Infection Control I: Patient Safety, PPE, Aerosols, Hand Hygiene, and Emergencies
8.1 Domain 3A Patient Safety and Disease Transmission Map 8.2 Standard Precautions, Barriers, and Room Readiness 8.3 Hand Hygiene and PPE Selection 8.4 Aerosol, Spatter, HVE, Air Evacuation, and Rinses 8.5 Infectious Disease Transmission and Exposure Response 8.6 Medical Emergencies, First Aid, BLS, and CPR Recognition
9 Infection Control II: Disinfection, Sterilization, Waterlines, Sharps, and Cross-Contamination
9.1 Treatment Area Turnover and Surface Risk 9.2 Barrier Selection, Placement, and Removal 9.3 Instrument Transport, Cleaning, and Sterilization Flow 9.4 Sterilization Monitoring, Storage, and Release Decisions 9.5 Dental Waterlines, Evacuation Lines, and Flushing 9.6 Sharps, Contaminated Waste, and Cross-Contamination Scenarios
10 Laws and Regulations: Consent, HIPAA, Abuse Reporting, Records, Conduct, and Scope
10.1 Domain 4 Exam Role and Legal Judgment 10.2 Consent, Patient Autonomy, and Chairside Communication 10.3 HIPAA, Privacy, Minimum Necessary, and Office Workflow 10.4 Suspected Abuse, Neglect, Exploitation, and Reporting 10.5 Records, Documentation, Corrections, and Release 10.6 Professional Conduct, Permitted Duties, and Scope Boundaries
11 RDA Study Plan: Domain Weighting, Scenario Practice, Pacing, and Error Review
11.1 Build the Plan From the Current Outline 11.2 Four-Week Study Plan for Recent Training 11.3 Six-Week Plan for Working Candidates 11.4 Eight-Week Plan for Rebuilding Foundations 11.5 Pacing for 125 Items in Three Hours 11.6 Scenario Practice and Error Logs 11.7 Dental Board Outline Final Checklist
12 Final RDA Review: Test Day, License Issuance, Renewal, and Next Steps
12.1 PSI Test-Day Timeline and Checklist 12.2 Identification, Tutorial, and Computer Navigation 12.3 Results and Retake Workflow 12.4 License Issuance After Passing 12.5 Renewal Basics After Licensure 12.6 RDAEF, OA, and DANB Next Steps 12.7 Final 48 Hours and Post-Exam Decision Tree
5.6 Bases, Liners, Matrices, and Wedges
Key Takeaways Explain This Topic AI
A liner is a thin (~0.5 mm) coating that seals dentin and may be therapeutic (calcium hydroxide stimulates reparative/tertiary dentin); a base is a thicker insulating layer that protects the pulp from thermal and chemical injury and supports the restoration.
Cavity varnish is a thin resin film that seals dentinal tubules under amalgam; glass ionomer is widely used as a base/liner because it bonds to tooth structure and releases fluoride.
The Tofflemire (universal) matrix system has three parts — retainer, band, and wedge — and placing, wedging, and removing matrices for restorative procedures is an allowable California RDA duty.
The band's smaller circumference faces gingivally; the wedge seats in the gingival embrasure to seal the margin against overhang and to separate the teeth, offsetting band thickness for a tight contact.
Last updated: October 2026
Cavity protection: varnishes, liners, and bases
Under a restoration the dentin and pulp must be protected from bacteria, thermal shock, and chemical irritation. Three categories of intermediary materials do this, distinguished mainly by thickness and function :
Material Thickness Primary role Common examples
Varnish Very thin film Seals dentinal tubules; reduces microleakage under amalgam. Copal or resin cavity varnish (not used under composite).
Liner ~0.5 mm Seals dentin; may be therapeutic (stimulate tertiary dentin, antibacterial). Calcium hydroxide, resin-modified glass ionomer, flowable liners.
Base Thicker (1 mm+) Insulates against thermal/chemical injury and supports the restoration. Glass ionomer, zinc oxide-eugenol (ZOE), zinc phosphate.
Calcium hydroxide is the classic therapeutic liner: placed on the deepest dentin near the pulp, it is alkaline, antibacterial, and stimulates the formation of reparative (tertiary) dentin . Glass ionomer is a versatile base/liner that chemically bonds to tooth structure and releases fluoride , helping resist recurrent caries. Zinc oxide-eugenol is sedative to the pulp but eugenol can interfere with resin polymerization, so it is avoided directly under composite. Cavity varnish is reserved for amalgam because its solvent and film are incompatible with bonded resin.
The general placement order in a deep prep is therapeutic liner first (over the deepest dentin only), then base if needed, then the restoration — never covering the entire prep with a thick base that weakens retention. BPC 1752.4(a)(7) permits an RDA to place bases, liners, etch, and bonding agents; it does not authorize the RDA to diagnose the preparation or place a permanent restoration. The permanent-restoration boundary is stated in BPC 1750.1(d)(2) .
How depth of the preparation drives material choice
The deeper the cavity, the more pulpal protection is needed. A shallow prep in enamel and superficial dentin may need only the bonding system; a moderate prep benefits from a liner or thin glass-ionomer layer; a deep prep near the pulp calls for a therapeutic calcium-hydroxide or resin-modified glass-ionomer liner on the deepest spot, sometimes with a base to insulate against the metal of an amalgam. Because metal conducts heat , thermal insulation matters more under amalgam than under composite, which is itself an insulator. This is why varnish and ZOE pair historically with amalgam, and bonded liners pair with composite.
The RDA who understands this logic can anticipate which protective material the dentist will request based on the depth and the planned restoration, and can have it dispensed and ready inside its working time.
Matrix systems and wedges for Class II restorations
A Class II preparation removes one or both proximal (mesial/distal) walls , so the missing wall must be rebuilt temporarily to confine the restorative material and form a proper contour and contact with the adjacent tooth. A matrix supplies that wall; a wedge seals the gingival margin and separates the teeth. Placing, wedging, and removing matrices for restorative procedures is an allowable RDA duty in California (BPC §1750.1), so candidates must know the system precisely.
The Tofflemire (universal) matrix has three parts: the retainer (a holder with a locking vise and an adjusting knob/spindle and a guide knob), a thin metal or clear matrix band , and a wedge . Key facts and steps:
Band shape: the band is wider on one side; its smaller circumference faces gingivally and the larger circumference faces occlusally, matching the tooth's natural taper.
Loading the retainer: form the band into a loop, slide it into the retainer with the slotted (guide) channels facing the gingiva and the diagonal slot opening toward the retainer; tighten the spindle to lock the band.
Burnish a slight curve/contour into the band so it reproduces proximal anatomy.
Seat the loop over the prepared tooth with the retainer toward the buccal; the band should extend about 1–1.5 mm above the cavosurface margin occlusally and slightly below the gingival margin.
Wedge: insert a wooden or plastic wedge from the lingual (larger) embrasure into the gingival embrasure so it presses the band against the gingival margin.
Tighten the band, then loosen slightly after wedging so the band can be condensed against the adjacent tooth for a tight contact.
Why the wedge matters
The wedge does two jobs: it adapts the band to the gingival margin , preventing a gingival overhang of excess material, and it separates the teeth slightly to compensate for the band's thickness so that, once the band is removed, a tight proximal contact remains. A missing or poorly placed wedge produces an open contact or an overhang — both common exam distractors. On the exam, recognizing that a Class II needs the full retainer + band + wedge system, and that the smaller band circumference goes gingivally, separates strong answers from weak ones.
After the restoration sets, the retainer is unscrewed and removed buccally, the band is teased out, and the wedge is removed, leaving the rebuilt proximal wall intact.
Other matrix systems and removal sequence
The Tofflemire is the universal system, but candidates should recognize alternatives. Sectional matrices use a small curved metal band plus a separating ring (G-ring) and are favored for composite because they create a tighter, more anatomic contact; clear plastic (Mylar) strip matrices are used for anterior Class III/IV composites because light cures through them and they leave a smooth surface; automatrix bands are retainerless. Whatever the system, the RDA's allowable role is the same: assemble it, place and wedge it under the dentist's direction, and remove it cleanly.
Removal order matters and is a classic ordering item. For a Tofflemire: (1) loosen and remove the retainer first, sliding it toward the occlusal/buccal; (2) gently tease the band out in a buccolingual direction so the new restoration is not fractured; (3) remove the wedge last. Reversing the order — pulling the band while the retainer still locks it — can dislodge the fresh restoration or open the contact. Throughout, the RDA confirms the gingival margin is smooth with no overhang, an inspection point the dentist relies on before dismissing the patient.