Study guide
Patient Care, Safety, and Infection Control
RDMS OB/GYN Study Guide Exam
Track your progress as you read
Finished sections get a check mark.
1 Exam Map, Physics, and Protocols
RDMS OB/GYN Exam Format and Blueprint Ultrasound Physics for OB/GYN Instrumentation, Artifacts, and Image Optimization Exam Protocols and Documentation Patient Care, Safety, and Infection Control
2 First Trimester Obstetrics
Early Pregnancy Dating and Viability Ectopic Pregnancy and PUL First-Trimester Anatomy and NT Early Pregnancy Failure and Complications
3 Second and Third Trimester Obstetrics
Fetal Biometry and Growth Fetal Anatomy Survey: CNS and Face Fetal Heart, Chest, and Abdomen Fetal Skeleton and Extremities Placenta, Cord, and Amniotic Fluid Multiple Gestation and High-Risk Findings
4 Gynecologic Ultrasound
Pelvic Anatomy and Uterine Variants Endometrium and Myometrium Pathology Ovaries, Adnexal Masses, and Doppler PID and Endometriosis Imaging Infertility and Sonohysterography
5 Procedures and Exam Strategy
Interventional and Procedural Ultrasound Reporting, Measurements, and Critical Findings Image-Based Question Strategy RDMS Exam-Day Plan and Review
Patient Care, Safety, and Infection Control
Key Takeaways Explain This Topic AI
High-level disinfection (HLD) of endocavitary probes is mandatory between patients per manufacturer IFU and CDC guidelines.
Obstetric patients may have latex sensitivity, trauma history, or miscarriage anxiety—sonographer communication affects cooperation and image quality.
MRI safety zones and contrast policies are peripheral but appear when departments share suites; know basic ferromagnetic restrictions.
Ergonomic injury prevention includes adjustable chairs, probe grip, and alternating scanning hands during long anatomy surveys.
ALARA extends to thermal/mechanical indices, limiting non-diagnostic fetal "keepsake" imaging in clinical departments.
Last updated: July 2026
Quick Answer: High-level disinfect every endocavitary probe between patients per IFU. Apply ALARA (monitor TI/MI, minimize dwell). Use trauma-informed TV techniques. Follow ergonomics on long scans. Registry items link infection steps , contraindications , and patient safety to protocol.
Infection Prevention: Endocavitary Transducers
Endocavitary probes contact mucosa and are semi-critical devices per Spaulding classification. Unless a probe is sheath-covered with a sterile barrier for specific procedural uses, high-level disinfection (HLD) after each patient is standard.
- Step Purpose
- Point-of-use wipe Remove gel and organic debris immediately
- Leak test (if required) Detect sheath compromise on covered probes
- HLD soak/wipe per IFU Kill spores where indicated (glutaraldehyde, hydrogen peroxide systems, trophon, etc.)
- Rinse/dry per IFU Remove disinfectant residue
- Storage hung Prevent recontamination
Low-level disinfection is insufficient for uncoved intracavitary use. Registry may present a scenario where a probe was wiped with alcohol only—incorrect.
Worked Scenario: Busy Clinic Shortcut
A colleague runs TV scans without HLD between patients, using probe covers only. Covers reduce but do not eliminate shaft contamination risk; mucosal contact still requires HLD of the probe after removal per CDC and AIUM statements. Correct answer: cease practice and follow HLD.
- Patient Communication and Special Populations
- Obstetric Anxiety
Patients may fear bad news. Use plain language, confirm understanding before TV insertion, and offer chaperones per policy. For early pregnancy loss scans, coordinate with ordering provider before delayed room entry when possible.
Trauma-Informed Transvaginal Ultrasound
Explain control: patient may insert probe, stop anytime.
Avoid forcing probe; use smallest footprint gel amount.
Document if TV declined and TA limitations.
Pediatric and Adolescent GYN
Guardian consent, chaperone requirements, and sensitivity to confidentiality laws vary by state—know institutional policy for registry ethics-style items.
Contraindications and Precautions
- Situation Ultrasound Approach
- Active vaginal bleeding heavy TV may be deferred; TA first
- Premature ROM concern Minimize transducer pressure; sterile technique if indicated
- Known latex allergy Non-latex probe covers and gloves
- MR conditional implants Not US issue, but know patients may ask; US unaffected
- Ergonomics and Repetitive Injury
Long anatomy surveys cause shoulder, wrist, and back strain. Mitigations:
- Adjust bed height so shoulder relaxed
- Use left hand for probe on right-sided placentas alternately
- Micro-breaks between patients
- Cable management to avoid torque on wrist
Registry rarely tests OSHA detail but may ask best ergonomic practice.
Ultrasound Safety and ALARA
Although diagnostic ultrasound lacks proven fetal harm at approved outputs, ALARA remains mandatory:
Avoid non-medical fetal imaging sessions in clinical departments (FDA statements).
Limit spectral Doppler exposure in first trimester when B-mode/M-mode suffices for heart rate.
Display and understand TI (TIS/TIB) and MI ; document output mode changes.
Contrast Agents in Pelvic US
IV ultrasound contrast (e.g., for liver) is uncommon in pure OB/GYN registry but know pregnancy contraindications for many agents if presented comparatively.
Emergency Recognition (Sonographer Role)
Sonographers are not diagnosticians but must recognize when to escalate :
- Maternal hypotension with free fluid and adnexal mass (ruptured ectopic)
- Non-viable exam with retained products and heavy bleeding
- Umbilical cord prolapse on bedside scan (OB emergency)
Correct action: notify physician immediately, initiate department critical results pathway.
HIPAA and Image Confidentiality
Patient identifiers on images and reports must be protected. Sharing fetal images on personal devices violates most institutional policies. Registry ethics questions may ask appropriate response when a patient requests photos—follow facility policy, use approved printing or secure portal.
Latex and Probe Cover Compatibility
Latex probe covers can cause allergic reaction; non-latex alternatives must be available. Sheath tears during TV exam require documenting whether re-scan is needed and ensuring HLD still occurs after probe removal.
Exam Traps
Assuming probe cover replaces HLD (it does not for standard TV).
Believing sterile gel alone sterilizes the probe.
Ignoring chaperone policy for sensitive exams.
Proceeding with TV despite active heavy bleeding without clinical clearance.
Patient care questions reward the safest, guideline-aligned action, not the fastest room turnover.
Sterile vs. Clean Technique Boundaries
Routine diagnostic transvaginal ultrasound uses clean technique with HLD between patients—not sterile field unless entering a procedure suite for egg retrieval or biopsy. Amniocentesis uses sterile probe cover, sterile gel, and sterile needle path. Confusing clean and sterile on registry items leads to wrong answers about gel type and probe preparation.
Special Considerations in Pregnancy Loss
Patients undergoing viability scans may be alone or with partner; offer privacy for grief and avoid casual conversation in waiting areas. Sonographers should not withhold visible findings from the ordering team while remaining within scope—notify provider when non-viable criteria met so counseling can occur. Document number of gestational sacs in multiples before and after loss for legal and clinical accuracy.
Disability and Language Access
Provide qualified interpreters for informed consent on invasive procedures; family members are not substitutes on registry ethics questions. Patients with mobility limitations need bed positioning that still allows ergonomic scanning without rushing—image quality and patient dignity both matter for complete studies.
Fire Safety and Contrast Precautions
Although MRI safety zones do not govern ultrasound, combined suites appear on exams. Ferromagnetic objects near MRI are forbidden; ultrasound probes are safe in US rooms. IV microbubble contrast for liver is contraindicated in pregnancy—know contrast pregnancy category comparisons if a cross-over item appears.