Study guide

11.1 Sampling, Preservation & Chain of Custody

South Carolina Water/Wastewater Operator Study Guide Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: South Carolina Regulations & Licensing Framework

1.1 SC Environmental Certification Board & Chapter 51 Regulations 1.2 Certification Levels & Experience Requirements 1.3 Facility Classifications & Operator-in-Charge Duties 1.4 Exam Logistics, Scoring & Study Resources

2 Chapter 2: Source Water Characteristics

2.1 Raw Water Sources & Pretreatment 2.2 Groundwater Sources, Wells & GWUDI Determinations 2.3 Watershed Protection & Source Water Contaminants

3 Chapter 3: Water Treatment: Coagulation, Flocculation & Sedimentation

3.1 Coagulation & Flocculation Process Control 3.2 Sedimentation Basins & Clarification

4 Chapter 4: Water Treatment: Filtration

4.1 Granular Media & Membrane Filtration 4.2 Filter Operation, Backwash & Troubleshooting

5 Chapter 5: Water Treatment: Disinfection & Chemical Conditioning

5.1 Chlorination & Chemical Disinfection 5.2 CT Calculations & Disinfection Byproducts Compliance 5.3 Chloramines, Chlorine Dioxide, Ozone & UV 5.4 Corrosion Control & the Lead and Copper Rule 5.5 Fluoridation & Water Softening 5.6 Iron, Manganese, Taste & Odor Control

6 Chapter 6: Water Distribution Systems

6.1 Water Distribution Network Operations & Maintenance 6.2 Cross-Connection Control & Backflow Prevention 6.3 Distribution Hydraulics & Pressure Management 6.4 Pipes, Valves, Hydrants & Appurtenances 6.5 Storage Tanks & Reservoirs 6.6 Water Quality in Distribution: Flushing & Residual Management 6.7 Main Disinfection, Breaks & Repair

7 Chapter 7: Wastewater Collection & Preliminary Treatment

7.1 Wastewater Collection & Preliminary Operations 7.2 Sanitary Sewer Collection System Maintenance 7.3 Lift Station Pumps, Controls & Hydraulics

8 Chapter 8: Wastewater Treatment: Primary & Secondary

8.1 Wastewater Characteristics & Plant Loadings 8.2 Primary Sedimentation & Clarifier Operations 8.3 Activated Sludge Process Control & Operations 8.4 Activated Sludge Troubleshooting 8.5 Aeration Systems & Dissolved Oxygen Control 8.6 Fixed-Film & Lagoon Treatment Systems 8.7 Biological Nutrient Removal & Tertiary Treatment

9 Chapter 9: Wastewater Disinfection, Effluent & Industrial Treatment

9.1 Wastewater Disinfection & Dechlorination 9.2 Effluent Disposal, Reuse & Land Application 9.3 Physical/Chemical Industrial Wastewater Treatment 9.4 Industrial Pretreatment Programs

10 Chapter 10: Solids, Biosolids & Regulatory Permitting

10.1 Sludge Thickening, Digestion & Dewatering 10.2 Biosolids Stabilization & Part 503 Land Application 10.3 Clean Water Act & NPDES Permit Compliance 10.4 Safe Drinking Water Act Compliance & Public Notification

11 Chapter 11: Laboratory Analysis & Quality Control

11.1 Sampling, Preservation & Chain of Custody 11.2 Physical & Chemical Water Quality Analysis 11.3 Wastewater Process Testing & Analytical Methods 11.4 Microbiological Testing & Quality Assurance 11.5 Data Validation, Reporting & Laboratory Certification

12 Chapter 12: Equipment Operation & Maintenance

12.1 Pumps: Types, Curves & Cavitation 12.2 Motors, Drives & Electrical Fundamentals 12.3 Bearings, Seals, Couplings & Lubrication 12.4 Flow Measurement & Process Instrumentation 12.5 Chemical Feed Equipment & Calibration 12.6 SCADA, Controls & Preventive Maintenance Programs

13 Chapter 13: Safety, Security & Administrative Procedures

13.1 Confined Space Entry & Atmospheric Hazards 13.2 Chlorine Gas Safety & Emergency Response 13.3 Lockout/Tagout, PPE, Hazard Communication & Excavation 13.4 Security, Vulnerability Assessment & Emergency Response Planning 13.5 Recordkeeping, Reporting & Administrative Duties

14 Chapter 14: Process Calculations & Hydraulic Math

14.1 Basic Water & Wastewater Math Fundamentals 14.2 Chemical Feed Rate & Dosage Calculations 14.3 Detention Time & Volumetric Flow Calculations 14.4 Removal Efficiency & Process Loading Rates 14.5 Pump Hydraulics & Horsepower Calculations 14.6 Activated Sludge Process Control Math

11.1 Sampling, Preservation & Chain of Custody

Key Takeaways Explain This Topic AI

A grab sample captures conditions at one instant while a composite sample represents average conditions over a period, and permits specify which is required.

Flow-proportional composites weight each aliquot by flow and are required where flow varies significantly.

Most samples are preserved at 4 degrees Celsius, with acid preservation to pH below 2 for metals and for nutrients requiring sulfuric acid.

Bacteriological sample bottles contain sodium thiosulfate to neutralize residual chlorine and must not be rinsed before sampling.

Holding times run from collection to analysis, and an exceeded holding time invalidates the result regardless of how carefully the analysis was performed.

Last updated: August 2026

11.1 Sampling, Preservation & Chain of Custody

Laboratory Analysis is a full content area on both the water and wastewater standardized exams, and a surprising share of the questions are about the sample , not the test. A perfectly executed analysis of a badly collected sample produces a precisely wrong number.

1. Grab vs. Composite

Grab sample Composite sample

What it is A single sample taken at one point in time Multiple aliquots combined over a period, commonly 24 hours

Represents Conditions at that instant Average conditions over the period

Required for Parameters that change rapidly or are lost on standing : pH, temperature, dissolved oxygen, chlorine residual, bacteriological , oil and grease, volatile organics, sulfide, cyanide, settleable solids BOD, COD, TSS, nutrients, metals — most NPDES effluent parameters

Never used for Averaging a variable stream Anything that changes with time in the container or is lost to volatilization

The rule that catches people: you can never composite a bacteriological, dissolved oxygen, chlorine residual, pH, volatile organic, or oil and grease sample. They change in the bottle, or the compositing procedure itself destroys them.

Composite types

  • Type Method When required
  • Time-proportional Equal aliquot volume at equal time intervals Acceptable where flow is relatively constant

Flow-proportional (flow-weighted) Aliquot volume or frequency varies with flow Required where flow varies significantly — the usual NPDES requirement

Worked example. A permit requires a flow-proportional 24-hour composite with a total volume of 2,000 mL and 24 hourly aliquots. Total daily flow is 1.20 MG; the 8:00 a.m. hourly flow is 0.075 MG. Aliquot = 2,000 mL × 0.075 1.20 = 125 mL \text{Aliquot} = 2{,}000 \text{ mL} \times \frac{0.075}{1.20} = \textbf{125 mL} Aliquot = 2 , 000 mL × 1.20 0.075 ​ = 125 mL

Equal 83 mL aliquots would under-represent the peak hour and bias the result low.

2. Where to Sample

Collect from a well-mixed, representative location — not from a quiescent corner, not at a wall, not immediately downstream of a chemical injection point.

For a channel, sample at the centroid of flow at mid-depth, avoiding both the surface film and the bottom sediment.

For automatic samplers, keep intake line velocity at least 2 ft/s so solids are drawn in rather than settling out in the tubing, and keep the line as short and steep as practical.

Purge taps and sample lines adequately before collecting — except where the protocol specifically requires stagnant water, as with first-draw lead and copper samples (Section 5.4).

Sample before and after the unit process you are evaluating when troubleshooting.

3. Preservation and Holding Times

Preservation slows the biological, chemical, and physical changes that begin the moment the sample leaves the stream.

  • Parameter Container Preservation Typical holding time
  • pH P or G None Analyze immediately (15 min)
  • Temperature — None Immediate
  • Dissolved oxygen (probe) — None Immediate
  • Chlorine residual P or G None Analyze immediately (15 min)
  • Turbidity P or G Cool 4 °C, dark 48 hours
  • BOD / CBOD P or G Cool 4 °C 48 hours
  • COD P or G Cool 4 °C, H₂SO₄ to pH < 2 28 days
  • TSS / TDS P or G Cool 4 °C 7 days
  • Ammonia, TKN, total phosphorus P or G Cool 4 °C, H₂SO₄ to pH < 2 28 days
  • Nitrate / nitrite P or G Cool 4 °C 48 hours
  • Metals (total) P or G HNO₃ to pH < 2 6 months
  • Mercury P or G HNO₃ to pH < 2 28 days
  • Cyanide P or G NaOH to pH > 12 , cool 14 days
  • Oil and grease Glass only Cool 4 °C, H₂SO₄ or HCl to pH < 2 28 days
  • Bacteriological Sterile, with sodium thiosulfate Cool 4 °C Drinking water 30 hours; wastewater 8 hours
  • The four rules that matter most

Holding time runs from collection to analysis. Exceeding it invalidates the result, and the analysis must be repeated on a fresh sample. There is no waiver for a good reason.

Bacteriological bottles contain sodium thiosulfate to neutralize any chlorine residual, which would otherwise continue killing organisms in transit and bias the result low. Never rinse the bottle — rinsing removes the thiosulfate. Fill to the marked line, leaving headspace for mixing.

Oil and grease requires a glass container , because oil adheres to plastic. Collect it as a grab and analyze the entire container — you cannot pour off a portion.

Never overfill a container that has preservative already in it , and never add preservative to a bacteriological bottle.

4. Sterile Technique for Bacteriological Samples

Select a cold-water tap without a leaking aerator or swivel ; remove hoses and screens; flush 2–5 minutes .

Do not touch the inside of the cap or the bottle neck , and do not set the cap down.

Fill to the 100 mL line , leaving headspace.

Record the free and total chlorine residual, time, date, location, and collector .

Cool to ≤ 10 °C and deliver within the holding time — 30 hours for drinking water compliance samples, 8 hours for wastewater under 40 CFR Part 136.

Never sample from a drinking fountain, hose bibb, or a tap with a threaded swivel or leaking valve .

5. Chain of Custody

A sample is in custody when it is in your physical possession , in your view , secured by you, or in a secured area restricted to authorized personnel .

What a chain of custody record must show

  • Element Why
  • Unique sample identification Ties the container to the record
  • Collection date and time Starts the holding time clock
  • Sample location and type (grab/composite) Establishes representativeness
  • Collector's name and signature Accountability
  • Parameters requested and preservation used Tells the lab what to do

Every transfer , with signature, date, and time of both the person relinquishing and the person receiving Establishes unbroken custody

Condition on receipt , including temperature Verifies preservation held

Samples are transported in sealed, iced coolers , often with custody seals across the lid so tampering would be visible. A temperature blank is frequently included so the lab can document the receipt temperature without opening a real sample.

Why this matters legally: monitoring data submitted to SC DES supports enforcement, and permit compliance data can end up in court. A break in the chain of custody — an unsigned transfer, a sample left unattended in an unlocked truck, a cooler received at 15 °C — can make an otherwise valid result indefensible. Falsifying any part of it is grounds for license revocation under Chapter 51 and carries independent criminal exposure (Section 1.1).

6. Field Quality Control Samples

  • QC sample What it detects
  • Field blank Contamination from containers, preservative, or field handling
  • Trip blank Contamination during transport, especially for volatile organics
  • Equipment / rinsate blank Inadequate decontamination of reusable sampling equipment
  • Field duplicate Sampling and analytical precision combined
  • Field matrix spike Matrix interference and recovery

A positive field blank means the contamination came from your process, not the water — investigate before reporting any associated result.