Study guide

16.1 Synchronous & Induction Motors

CAAS SAR-66 AML Module 3 — Electrical Fundamentals Exam

Track your progress as you read

Finished sections get a check mark.

1 Introduction & Exam Overview

1.1 Current Exam Facts 1.2 Knowledge Levels & Study Approach for Module 3

2 Electron Theory & Static Electricity

2.1 Electron Theory & Atomic Structure 2.2 Conductors, Semiconductors & Insulators 2.3 Static Electricity, Coulomb's Law & Conduction

3 Terminology & Generation of Electricity

3.1 Electrical Terminology 3.2 Generation of Electricity

4 DC Sources of Electricity

4.1 Primary & Secondary Cells 4.2 Lead-Acid & Nickel-Cadmium Batteries 4.3 Series/Parallel Cells, Internal Resistance, Thermocouples & Photocells

5 DC Circuits

5.1 Ohm's Law 5.2 Kirchhoff's Voltage & Current Laws 5.3 Series/Parallel Networks & Supply Internal Resistance

6 Resistance & Resistors

6.1 Resistivity & Factors Affecting Resistance 6.2 Resistor Colour Code, Tolerance & Preferred Values 6.3 Series/Parallel Resistors, Potentiometers & Rheostats 6.4 Wheatstone Bridge, Thermistors & Temperature Coefficient

7 Power, Work & Energy

7.1 Power, Work & Energy Concepts 7.2 Power Dissipation & Calculations

8 Capacitance & Capacitors

8.1 Capacitor Operation & Factors Affecting Capacitance 8.2 Series/Parallel Capacitors & Types 8.3 RC Time Constants, Energy Storage & Testing

9 Magnetism

9.1 Theory of Magnetism & Magnetic Materials 9.2 Electromagnets & Hand Rules 9.3 MMF, Flux Density, Permeability, Hysteresis & Eddy Currents

10 Inductance & Inductors

10.1 Faraday's Law & Induced Voltage 10.2 Self & Mutual Inductance, Lenz's Law 10.3 Back EMF, Saturation & Inductor Applications

11 DC Motor/Generator Theory

11.1 Basic Motor & Generator Theory 11.2 DC Generators — Construction & Operation 11.3 DC Motors — Series, Shunt, Compound & Starter-Generators

12 AC Theory

12.1 Sinusoidal Waveforms — Phase, Period, Frequency 12.2 Peak, Average, RMS Values & Calculations 12.3 Non-Sinusoidal Waves & Single/Three-Phase Principles

13 R, L & C Circuits

13.1 Phase Relationships in R, L, C Circuits 13.2 Impedance, Phase Angle & Power Factor 13.3 True, Apparent & Reactive Power

14 Transformers

14.1 Transformer Construction & Operation 14.2 Losses, Efficiency, Load/No-Load & Turns Ratio 14.3 Three-Phase Transformers & Autotransformers

15 Filters & AC Generators

15.1 Filters — Low Pass, High Pass, Band Pass, Band Stop 15.2 AC Generator Principles & Construction 15.3 Star/Delta Connections & Permanent Magnet Generators

16 AC Motors

16.1 Synchronous & Induction Motors 16.2 Speed Control, Direction & Rotating Field Methods

16.1 Synchronous & Induction Motors

Key Takeaways Explain This Topic AI

Synchronous motors lock rotor speed exactly to synchronous speed ns = 120f/P (P = number of poles); induction motors always run slightly slower under load because of slip

Slip s = (ns − n)/ns; rotor frequency and induced EMF both scale with slip; at standstill s = 1, at synchronous speed s = 0

Polyphase (especially three-phase) induction motors are self-starting from a rotating stator field; single-phase induction motors need an auxiliary starting method

Synchronous motors need DC rotor excitation (or permanent magnets) and a means to bring the rotor near ns before locking; they can run at unity or leading power factor

Aircraft AC motors appear in fans, pumps, actuators, and ground equipment — Module 3 expects construction, slip, and ns formula fluency, not specific part numbers

Last updated: July 2026

16.1 Synchronous & Induction Motors

Quick Answer: Synchronous motors lock to ns = 120f/P (exact speed). Induction motors run below ns with slip s = (ns − n)/ns. Three-phase induction motors start from a rotating stator field ; single-phase need help to start. Sync motors need DC field (or PM) and pull-in near ns.

CAAS SAR-66 Module 3 topic 3.18 AC Motors follows AC generators (3.17). Generation created a rotating magnetic field at electrical frequency f. Motors reverse the story: a rotating (or oscillating) field interacts with a rotor to produce torque. Two families dominate Module 3: synchronous and induction motors, in single-phase and polyphase forms.

Shared Vocabulary Before the Split

  • Term Meaning
  • Stator Stationary core and windings connected to the AC supply
  • Rotor Rotating member that develops torque
  • Poles (P) Number of magnetic poles of the machine (must be even: 2, 4, 6, …)
  • Synchronous speed ns Speed of the rotating magnetic field in rev/min
  • Rotor speed n Actual shaft speed in rev/min
  • Slip s Fractional lag of rotor behind the field (induction motors)

Synchronous speed formula (memorise):

ns = 120 f / P

  • Symbol Unit Notes
  • ns rev/min Field (and sync-motor) speed
  • f Hz Supply frequency
  • P — Number of poles (not pole- pairs ; Module 3 / Part-66 style uses total poles)

Worked example 1 — aircraft 400 Hz. Four-pole motor on 400 Hz:

ns = 120 × 400 / 4 = 12 000 rev/min .

Worked example 2 — utility 50 Hz. Same four-pole machine on 50 Hz:

ns = 120 × 50 / 4 = 1500 rev/min .

Worked example 3 — two-pole 400 Hz. ns = 120 × 400 / 2 = 24 000 rev/min — very high shaft speed; multipole designs lower ns for the same f.

Synchronous Motors — Construction and Principle

A synchronous motor runs at exactly ns in steady state (zero average slip). The stator is wound like an alternator stator (often three-phase). The rotor carries a DC-excited field (slip rings or brushless exciter) or permanent magnets . Once the rotor magnetic poles lock with the rotating stator field, the shaft turns in step with the field.

  • Part Role
  • Stator AC windings Produce rotating (polyphase) or pulsating (single-phase) field at frequency f
  • Rotor field DC or PM poles — magnetic “lock” to stator field
  • Excitation (wound rotor) Sets field strength → affects power factor and pull-out torque
  • Damper / amortisseur windings (often) Help starting and damp hunting

Operating principle. After the rotor is brought near ns (by damper winding induction action, pony motor, or frequency ramping), rotor poles lock to stator poles. Torque then maintains synchronism against load up to pull-out torque . Overload beyond pull-out → loss of sync (“pull-out”) — rotor slips poles and must be restarted properly.

  • Characteristic Synchronous motor
  • Steady speed Exactly ns (independent of load, within sync)
  • Starting Not inherently self-starting from standstill without help
  • Excitation DC field or PM required
  • Power factor Can be lagging, unity, or leading (over-excited)
  • Slip in sync Zero average

Aircraft / hangar link. Pure classical sync motors are less common as everyday cabin fans than induction motors, but the ns formula and lock-to-field idea underpin constant-speed AC drives, some actuator concepts, and understanding why frequency and poles fix speed. Permanent-magnet sync machines appear in modern compact drives.

Worked concept — lock. A 6-pole sync motor on 400 Hz: ns = 120 × 400 / 6 = 8000 rev/min . At 50% rated torque it still runs 8000 rev/min if it remains in sync. Speed does not sag with load the way an induction motor does.

Induction Motors — Construction and Principle

An induction motor (asynchronous motor) has a stator that creates a rotating field at ns. The rotor has no DC excitation . Rotor currents are induced by relative motion (slip) between field and rotor conductors — Faraday + Lenz: induced currents create torque that tries to catch the field but never quite reaches ns under load (if it did, induction would cease).

Rotor constructions

  • Type Construction Notes
  • Squirrel-cage Shorted bars in laminated core, end rings Rugged, common, low maintenance

Wound-rotor (slip-ring) Three-phase winding brought out via slip rings External resistance for starting/torque shaping

  • Part Role
  • Stator Polyphase or single-phase windings on laminated core
  • Rotor (cage or wound) Induced currents → torque
  • Air gap Magnetic coupling path — keep clean and within limits
  • End rings / slip rings Close cage circuit or connect external resistors
  • Slip
  • s = (ns − n) / ns (often expressed as a percentage: s × 100%)
  • Condition Slip
  • Standstill (start) s = 1 (100%)
  • No-load (ideal frictionless) s ≈ 0
  • Rated load Small positive s (e.g. 2–5% typical teaching figures)
  • Synchronous speed s = 0 — no induction torque in a pure induction machine

Rotor electrical frequency fr ≈ s × f . At start, fr = f; near sync, fr is low.

Worked example 4 — slip calculation. Four-pole, 400 Hz → ns = 12 000 rev/min. Shaft runs at 11 640 rev/min.

s = (12 000 − 11 640) / 12 000 = 360 / 12 000 = 0.03 = 3% .

Worked example 5 — find n from slip. Same machine, s = 4% = 0.04.

n = ns (1 − s) = 12 000 × 0.96 = 11 520 rev/min .

Worked example 6 — 50 Hz check. Four-pole, 50 Hz, n = 1440 rev/min.

ns = 1500; s = (1500 − 1440)/1500 = 0.04 = 4% .

  • Polyphase vs Single-Phase Induction Motors
  • Polyphase (especially three-phase)

Three stator windings 120° apart produce a true rotating magnetic field of nearly constant magnitude (topic 3.17 rotating-field idea). The rotor starts and runs without an auxiliary phase under normal conditions.

  • Trait Three-phase induction
  • Starting Self-starting
  • Torque smoothness Good
  • Direction Swap any two supply lines → reverse rotation (§16.2)
  • Aircraft / industry Fans, pumps, compressors, ground equipment
  • Single-phase induction

A single stator winding produces a pulsating field, equivalent to two counter-rotating fields. Net starting torque is zero without an auxiliary method (capacitor, shaded pole, etc. — §16.2). Once running, the motor continues on the main winding with slip.

Trait Single-phase induction

Starting Needs auxiliary winding / shaded pole / etc.

  • Running Possible after start; lower performance than polyphase of same size
  • Use Small fans, pumps, appliances, some aircraft accessories
  • Synchronous vs Induction — Exam Comparison
  • Feature Synchronous Induction
  • Steady speed Exactly ns Below ns (slip)
  • Rotor excitation DC or PM None (induced)
  • Self-starting (polyphase) Generally needs help Yes (3-phase)
  • Slip Zero in sync Essential for torque
  • Power factor control Yes (excitation) Usually lagging
  • Typical Module 3 calc ns = 120f/P ns and s = (ns−n)/ns
  • Torque and Load Behaviour (Qualitative)

Induction: As load rises, rotor slows slightly → slip rises → induced rotor EMF/current rise → more torque until the peak ( breakdown ) torque. Beyond that, motor stalls. Efficiency and heating worsen at high slip (start and heavy overload).

Synchronous: Speed fixed; load angle between rotor and stator fields increases with load. Too much load → pull-out. Over-excitation can make the machine draw leading current (acts like a capacitor to the bus — power-factor correction idea).

Section Synthesis

ns = 120f/P fixes field speed for both families.

Sync motors lock to ns; induction motors need slip and never stay at ns under load.

Cage vs wound rotor; three-phase self-start vs single-phase needs help.

Drill slip arithmetic both ways (n from s, s from n).

Next (§16.2): how to control speed and direction , and how capacitor, inductor, and shaded/split-pole methods create a rotating field for single-phase starting.