Study guide

8.3 RC Time Constants, Energy Storage & Testing

CAAS SAR-66 AML Module 3 — Electrical Fundamentals Exam

Track your progress as you read

Finished sections get a check mark.

1 Introduction & Exam Overview

1.1 Current Exam Facts 1.2 Knowledge Levels & Study Approach for Module 3

2 Electron Theory & Static Electricity

2.1 Electron Theory & Atomic Structure 2.2 Conductors, Semiconductors & Insulators 2.3 Static Electricity, Coulomb's Law & Conduction

3 Terminology & Generation of Electricity

3.1 Electrical Terminology 3.2 Generation of Electricity

4 DC Sources of Electricity

4.1 Primary & Secondary Cells 4.2 Lead-Acid & Nickel-Cadmium Batteries 4.3 Series/Parallel Cells, Internal Resistance, Thermocouples & Photocells

5 DC Circuits

5.1 Ohm's Law 5.2 Kirchhoff's Voltage & Current Laws 5.3 Series/Parallel Networks & Supply Internal Resistance

6 Resistance & Resistors

6.1 Resistivity & Factors Affecting Resistance 6.2 Resistor Colour Code, Tolerance & Preferred Values 6.3 Series/Parallel Resistors, Potentiometers & Rheostats 6.4 Wheatstone Bridge, Thermistors & Temperature Coefficient

7 Power, Work & Energy

7.1 Power, Work & Energy Concepts 7.2 Power Dissipation & Calculations

8 Capacitance & Capacitors

8.1 Capacitor Operation & Factors Affecting Capacitance 8.2 Series/Parallel Capacitors & Types 8.3 RC Time Constants, Energy Storage & Testing

9 Magnetism

9.1 Theory of Magnetism & Magnetic Materials 9.2 Electromagnets & Hand Rules 9.3 MMF, Flux Density, Permeability, Hysteresis & Eddy Currents

10 Inductance & Inductors

10.1 Faraday's Law & Induced Voltage 10.2 Self & Mutual Inductance, Lenz's Law 10.3 Back EMF, Saturation & Inductor Applications

11 DC Motor/Generator Theory

11.1 Basic Motor & Generator Theory 11.2 DC Generators — Construction & Operation 11.3 DC Motors — Series, Shunt, Compound & Starter-Generators

12 AC Theory

12.1 Sinusoidal Waveforms — Phase, Period, Frequency 12.2 Peak, Average, RMS Values & Calculations 12.3 Non-Sinusoidal Waves & Single/Three-Phase Principles

13 R, L & C Circuits

13.1 Phase Relationships in R, L, C Circuits 13.2 Impedance, Phase Angle & Power Factor 13.3 True, Apparent & Reactive Power

14 Transformers

14.1 Transformer Construction & Operation 14.2 Losses, Efficiency, Load/No-Load & Turns Ratio 14.3 Three-Phase Transformers & Autotransformers

15 Filters & AC Generators

15.1 Filters — Low Pass, High Pass, Band Pass, Band Stop 15.2 AC Generator Principles & Construction 15.3 Star/Delta Connections & Permanent Magnet Generators

16 AC Motors

16.1 Synchronous & Induction Motors 16.2 Speed Control, Direction & Rotating Field Methods

8.3 RC Time Constants, Energy Storage & Testing

Key Takeaways Explain This Topic AI

The RC time constant is τ = R × C; after about one τ, charge/discharge reaches ~63% of the total change toward the final value

Capacitor voltage follows exponential curves: charging toward V_final and discharging toward zero (ideal series RC)

Stored energy is W = ½ C V² (joules when C is in farads and V in volts)

Testing includes visual inspection, capacitance measurement, ESR/leakage checks, and never assuming a part is safe to touch when charged

Always discharge capacitors safely through a suitable resistor before handling — shorting with a screwdriver is unsafe practice

Last updated: July 2026

8.3 RC Time Constants, Energy Storage & Testing

Quick Answer: τ = R × C sets the speed of charging and discharging. Voltage changes exponentially — about 63% of the way to the final value in one τ, and essentially settled by ~ 5τ . Energy stored is W = ½CV² . Test capacitors with proper instruments after safe resistive discharge ; never rely on a casual short across large charged parts.

Static C = Q/V tells you how much charge a capacitor holds at a voltage. Aircraft and avionics circuits also care how fast that charge moves when R and C interact, how much energy is banked, and how to prove a part is healthy without getting shocked.

The Time Constant τ = RC

In a series RC circuit:

τ = R × C

  • Symbol Unit
  • τ (tau) second (s)
  • R ohm (Ω)
  • C farad (F)

Worked example 1 — find τ. R = 10 kΩ, C = 47 µF.

τ = 10 000 × 47 × 10⁻⁶ = 0.47 s .

Worked example 2 — find C from τ. A designer wants τ = 2.0 ms with R = 4.7 kΩ.

C = τ / R = 0.002 / 4700 ≈ 4.26 × 10⁻⁷ F ≈ 0.43 µF (nearest preferred value in practice).

Larger R or larger C → larger τ → slower exponential.

Exponential Charge (DC Series RC)

Assume an uncharged capacitor, series R, and a DC step of voltage V_S applied at t = 0.

  • Capacitor voltage: v_C(t) = V_S (1 − e^(−t/τ))
  • Charging current starts at I₀ = V_S / R and falls toward zero: i(t) = (V_S / R) e^(−t/τ)

Key percentages Module 3 expects:

  • Time Approximate v_C (charging from 0 toward V_S)
  • 1τ ~ 63% of V_S
  • 2τ ~ 86% of V_S
  • 3τ ~ 95% of V_S
  • 5τ ~ 99%+ — treated as fully charged for most practical purposes

Worked example 3 — voltage at 1τ. V_S = 28 V, τ = 0.47 s. At t = τ:

v_C ≈ 0.63 × 28 ≈ 17.6 V .

Worked example 4 — nearly charged. Same circuit: after 5τ ≈ 2.35 s , v_C is within about 1% of 28 V — call it charged for exam “fully charged” language unless the stem demands the exponential formula.

Exponential Discharge

A capacitor initially charged to V₀ , then connected across R alone (source removed):

v_C(t) = V₀ e^(−t/τ)

  • Time Approximate remaining voltage
  • 1τ ~ 37% of V₀ (falls by ~63%)
  • 5τ ~ 1% or less — treated as discharged for many practical checks

Worked example 5 — discharge. V₀ = 50 V, R = 100 kΩ, C = 10 µF → τ = 1.0 s. After 1 s, v_C ≈ 0.37 × 50 ≈ 18.5 V . After 5 s, only about 0.3–0.5 V remains in the ideal model.

Exam trap: “63%” on charge means up toward final; on discharge, voltage falls by about 63% in one τ (remaining ≈ 37%). Read the stem carefully.

Energy Storage: W = ½ C V²

The energy stored in the electric field of a capacitor is:

W = ½ C V²

Also W = ½ Q V = Q² / (2C) with Q = CV.

  • Quantity SI unit
  • W joule (J)
  • C farad (F)
  • V volt (V)

Worked example 6 — energy. C = 100 µF charged to 50 V.

W = 0.5 × 100 × 10⁻⁶ × 50² = 0.5 × 100 × 10⁻⁶ × 2500 = 0.125 J .

Worked example 7 — voltage effect. Same 100 µF at 100 V: W = 0.5 × 100 × 10⁻⁶ × 10 000 = 0.5 J — four times the energy at twice the voltage, because energy scales with V² .

That V² dependence is why high-voltage filter capacitors are hazardous even at modest microfarad values: energy — and shock/arc risk — climb quickly with voltage.

Testing Capacitors

Typical Module 3 / workshop checks:

Visual inspection — bulging electrolytic cans, leaked electrolyte, cracked ceramics, burnt smell, damaged leads.

Discharge first — before connecting meters or handling terminals (see safety below).

Capacitance measurement — LCR meter or capacitance function; compare to marked value within tolerance.

Resistance / insulation / leakage — a good capacitor (discharged) does not look like a steady low-resistance short on a simple ohmmeter after the brief charging kick; electrolytics show more complex behaviour. Excessive DC leakage is a fail.

ESR (equivalent series resistance) — elevated ESR on electrolytics often means “drying out” or degradation even if capacitance is still near nominal.

Substitution / in-circuit caution — parallel paths can fool meters; lift a lead when required by procedure.

Ohmmeter behaviour (idealised teaching point): On a discharged good capacitor, an analogue ohmmeter may kick as the meter charges C, then the needle drifts toward high resistance. A shorted capacitor reads low ohms continuously. An open capacitor may show no charging kick and infinite resistance. Confirm with a proper capacitance instrument when marks matter.

Safety Discharge

Capacitors can retain dangerous charge long after power is removed — especially large electrolytics on power supplies and high-voltage assemblies.

Safe practice:

Assume charged until proven otherwise.

Discharge through a resistor of appropriate value and wattage (and insulated probes), not by casually shorting terminals with a screwdriver (arc, pitted terminals, tool damage, and hazard).

For large energy, use a documented discharge tool/procedure; verify with a voltmeter that voltage is near zero.

Repeat verification — dielectric absorption can let voltage “reappear” slightly on some capacitors after an initial discharge.

Wear required PPE; follow aircraft/equipment maintenance manuals for high-voltage assemblies.

Worked safety estimate. A 470 µF capacitor at 300 V stores W = 0.5 × 470 × 10⁻⁶ × 90 000 ≈ 21 J — enough for a painful shock and a substantial arc. Treat it with respect.

Bleed resistors across high-voltage filter capacitors in equipment provide intentional slow discharge when power is removed; still verify with a meter before touching.

Putting τ, Energy, and Testing Together

  • Task Tool
  • How fast does the timing node rise? τ = RC and exponential percentages
  • How hard can a charged part shock/arc? W = ½CV²
  • Is the part still serviceable? Inspect, discharge, measure C/ESR/leakage
  • Is it safe to handle? Resistive discharge + voltmeter proof

Master τ = RC, the 63%/37%/5τ rules, W = ½CV², and discharge-before-test discipline. That closes CAAS Module 3 topic 3.9 Capacitance/Capacitor and prepares you for later AC capacitive reactance work in R, L, C circuit topics.