Study guide
8.3 RC Time Constants, Energy Storage & Testing
CAAS SAR-66 AML Module 3 — Electrical Fundamentals Exam
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
1.1 Current Exam Facts 1.2 Knowledge Levels & Study Approach for Module 3
2 Electron Theory & Static Electricity
2.1 Electron Theory & Atomic Structure 2.2 Conductors, Semiconductors & Insulators 2.3 Static Electricity, Coulomb's Law & Conduction
3 Terminology & Generation of Electricity
3.1 Electrical Terminology 3.2 Generation of Electricity
4 DC Sources of Electricity
4.1 Primary & Secondary Cells 4.2 Lead-Acid & Nickel-Cadmium Batteries 4.3 Series/Parallel Cells, Internal Resistance, Thermocouples & Photocells
5 DC Circuits
5.1 Ohm's Law 5.2 Kirchhoff's Voltage & Current Laws 5.3 Series/Parallel Networks & Supply Internal Resistance
6 Resistance & Resistors
6.1 Resistivity & Factors Affecting Resistance 6.2 Resistor Colour Code, Tolerance & Preferred Values 6.3 Series/Parallel Resistors, Potentiometers & Rheostats 6.4 Wheatstone Bridge, Thermistors & Temperature Coefficient
7 Power, Work & Energy
7.1 Power, Work & Energy Concepts 7.2 Power Dissipation & Calculations
8 Capacitance & Capacitors
8.1 Capacitor Operation & Factors Affecting Capacitance 8.2 Series/Parallel Capacitors & Types 8.3 RC Time Constants, Energy Storage & Testing
9 Magnetism
9.1 Theory of Magnetism & Magnetic Materials 9.2 Electromagnets & Hand Rules 9.3 MMF, Flux Density, Permeability, Hysteresis & Eddy Currents
10 Inductance & Inductors
10.1 Faraday's Law & Induced Voltage 10.2 Self & Mutual Inductance, Lenz's Law 10.3 Back EMF, Saturation & Inductor Applications
11 DC Motor/Generator Theory
11.1 Basic Motor & Generator Theory 11.2 DC Generators — Construction & Operation 11.3 DC Motors — Series, Shunt, Compound & Starter-Generators
12 AC Theory
12.1 Sinusoidal Waveforms — Phase, Period, Frequency 12.2 Peak, Average, RMS Values & Calculations 12.3 Non-Sinusoidal Waves & Single/Three-Phase Principles
13 R, L & C Circuits
13.1 Phase Relationships in R, L, C Circuits 13.2 Impedance, Phase Angle & Power Factor 13.3 True, Apparent & Reactive Power
14 Transformers
14.1 Transformer Construction & Operation 14.2 Losses, Efficiency, Load/No-Load & Turns Ratio 14.3 Three-Phase Transformers & Autotransformers
15 Filters & AC Generators
15.1 Filters — Low Pass, High Pass, Band Pass, Band Stop 15.2 AC Generator Principles & Construction 15.3 Star/Delta Connections & Permanent Magnet Generators
16 AC Motors
16.1 Synchronous & Induction Motors 16.2 Speed Control, Direction & Rotating Field Methods
8.3 RC Time Constants, Energy Storage & Testing
Key Takeaways Explain This Topic AI
The RC time constant is τ = R × C; after about one τ, charge/discharge reaches ~63% of the total change toward the final value
Capacitor voltage follows exponential curves: charging toward V_final and discharging toward zero (ideal series RC)
Stored energy is W = ½ C V² (joules when C is in farads and V in volts)
Testing includes visual inspection, capacitance measurement, ESR/leakage checks, and never assuming a part is safe to touch when charged
Always discharge capacitors safely through a suitable resistor before handling — shorting with a screwdriver is unsafe practice
Last updated: July 2026
8.3 RC Time Constants, Energy Storage & Testing
Quick Answer: τ = R × C sets the speed of charging and discharging. Voltage changes exponentially — about 63% of the way to the final value in one τ, and essentially settled by ~ 5τ . Energy stored is W = ½CV² . Test capacitors with proper instruments after safe resistive discharge ; never rely on a casual short across large charged parts.
Static C = Q/V tells you how much charge a capacitor holds at a voltage. Aircraft and avionics circuits also care how fast that charge moves when R and C interact, how much energy is banked, and how to prove a part is healthy without getting shocked.
The Time Constant τ = RC
In a series RC circuit:
τ = R × C
- Symbol Unit
- τ (tau) second (s)
- R ohm (Ω)
- C farad (F)
Worked example 1 — find τ. R = 10 kΩ, C = 47 µF.
τ = 10 000 × 47 × 10⁻⁶ = 0.47 s .
Worked example 2 — find C from τ. A designer wants τ = 2.0 ms with R = 4.7 kΩ.
C = τ / R = 0.002 / 4700 ≈ 4.26 × 10⁻⁷ F ≈ 0.43 µF (nearest preferred value in practice).
Larger R or larger C → larger τ → slower exponential.
Exponential Charge (DC Series RC)
Assume an uncharged capacitor, series R, and a DC step of voltage V_S applied at t = 0.
- Capacitor voltage: v_C(t) = V_S (1 − e^(−t/τ))
- Charging current starts at I₀ = V_S / R and falls toward zero: i(t) = (V_S / R) e^(−t/τ)
Key percentages Module 3 expects:
- Time Approximate v_C (charging from 0 toward V_S)
- 1τ ~ 63% of V_S
- 2τ ~ 86% of V_S
- 3τ ~ 95% of V_S
- 5τ ~ 99%+ — treated as fully charged for most practical purposes
Worked example 3 — voltage at 1τ. V_S = 28 V, τ = 0.47 s. At t = τ:
v_C ≈ 0.63 × 28 ≈ 17.6 V .
Worked example 4 — nearly charged. Same circuit: after 5τ ≈ 2.35 s , v_C is within about 1% of 28 V — call it charged for exam “fully charged” language unless the stem demands the exponential formula.
Exponential Discharge
A capacitor initially charged to V₀ , then connected across R alone (source removed):
v_C(t) = V₀ e^(−t/τ)
- Time Approximate remaining voltage
- 1τ ~ 37% of V₀ (falls by ~63%)
- 5τ ~ 1% or less — treated as discharged for many practical checks
Worked example 5 — discharge. V₀ = 50 V, R = 100 kΩ, C = 10 µF → τ = 1.0 s. After 1 s, v_C ≈ 0.37 × 50 ≈ 18.5 V . After 5 s, only about 0.3–0.5 V remains in the ideal model.
Exam trap: “63%” on charge means up toward final; on discharge, voltage falls by about 63% in one τ (remaining ≈ 37%). Read the stem carefully.
Energy Storage: W = ½ C V²
The energy stored in the electric field of a capacitor is:
W = ½ C V²
Also W = ½ Q V = Q² / (2C) with Q = CV.
- Quantity SI unit
- W joule (J)
- C farad (F)
- V volt (V)
Worked example 6 — energy. C = 100 µF charged to 50 V.
W = 0.5 × 100 × 10⁻⁶ × 50² = 0.5 × 100 × 10⁻⁶ × 2500 = 0.125 J .
Worked example 7 — voltage effect. Same 100 µF at 100 V: W = 0.5 × 100 × 10⁻⁶ × 10 000 = 0.5 J — four times the energy at twice the voltage, because energy scales with V² .
That V² dependence is why high-voltage filter capacitors are hazardous even at modest microfarad values: energy — and shock/arc risk — climb quickly with voltage.
Testing Capacitors
Typical Module 3 / workshop checks:
Visual inspection — bulging electrolytic cans, leaked electrolyte, cracked ceramics, burnt smell, damaged leads.
Discharge first — before connecting meters or handling terminals (see safety below).
Capacitance measurement — LCR meter or capacitance function; compare to marked value within tolerance.
Resistance / insulation / leakage — a good capacitor (discharged) does not look like a steady low-resistance short on a simple ohmmeter after the brief charging kick; electrolytics show more complex behaviour. Excessive DC leakage is a fail.
ESR (equivalent series resistance) — elevated ESR on electrolytics often means “drying out” or degradation even if capacitance is still near nominal.
Substitution / in-circuit caution — parallel paths can fool meters; lift a lead when required by procedure.
Ohmmeter behaviour (idealised teaching point): On a discharged good capacitor, an analogue ohmmeter may kick as the meter charges C, then the needle drifts toward high resistance. A shorted capacitor reads low ohms continuously. An open capacitor may show no charging kick and infinite resistance. Confirm with a proper capacitance instrument when marks matter.
Safety Discharge
Capacitors can retain dangerous charge long after power is removed — especially large electrolytics on power supplies and high-voltage assemblies.
Safe practice:
Assume charged until proven otherwise.
Discharge through a resistor of appropriate value and wattage (and insulated probes), not by casually shorting terminals with a screwdriver (arc, pitted terminals, tool damage, and hazard).
For large energy, use a documented discharge tool/procedure; verify with a voltmeter that voltage is near zero.
Repeat verification — dielectric absorption can let voltage “reappear” slightly on some capacitors after an initial discharge.
Wear required PPE; follow aircraft/equipment maintenance manuals for high-voltage assemblies.
Worked safety estimate. A 470 µF capacitor at 300 V stores W = 0.5 × 470 × 10⁻⁶ × 90 000 ≈ 21 J — enough for a painful shock and a substantial arc. Treat it with respect.
Bleed resistors across high-voltage filter capacitors in equipment provide intentional slow discharge when power is removed; still verify with a meter before touching.
Putting τ, Energy, and Testing Together
- Task Tool
- How fast does the timing node rise? τ = RC and exponential percentages
- How hard can a charged part shock/arc? W = ½CV²
- Is the part still serviceable? Inspect, discharge, measure C/ESR/leakage
- Is it safe to handle? Resistive discharge + voltmeter proof
Master τ = RC, the 63%/37%/5τ rules, W = ½CV², and discharge-before-test discipline. That closes CAAS Module 3 topic 3.9 Capacitance/Capacitor and prepares you for later AC capacitive reactance work in R, L, C circuit topics.