Study guide
5.3 Series/Parallel Networks & Supply Internal Resistance
CAAS SAR-66 AML Module 3 — Electrical Fundamentals Exam
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
1.1 Current Exam Facts 1.2 Knowledge Levels & Study Approach for Module 3
2 Electron Theory & Static Electricity
2.1 Electron Theory & Atomic Structure 2.2 Conductors, Semiconductors & Insulators 2.3 Static Electricity, Coulomb's Law & Conduction
3 Terminology & Generation of Electricity
3.1 Electrical Terminology 3.2 Generation of Electricity
4 DC Sources of Electricity
4.1 Primary & Secondary Cells 4.2 Lead-Acid & Nickel-Cadmium Batteries 4.3 Series/Parallel Cells, Internal Resistance, Thermocouples & Photocells
5 DC Circuits
5.1 Ohm's Law 5.2 Kirchhoff's Voltage & Current Laws 5.3 Series/Parallel Networks & Supply Internal Resistance
6 Resistance & Resistors
6.1 Resistivity & Factors Affecting Resistance 6.2 Resistor Colour Code, Tolerance & Preferred Values 6.3 Series/Parallel Resistors, Potentiometers & Rheostats 6.4 Wheatstone Bridge, Thermistors & Temperature Coefficient
7 Power, Work & Energy
7.1 Power, Work & Energy Concepts 7.2 Power Dissipation & Calculations
8 Capacitance & Capacitors
8.1 Capacitor Operation & Factors Affecting Capacitance 8.2 Series/Parallel Capacitors & Types 8.3 RC Time Constants, Energy Storage & Testing
9 Magnetism
9.1 Theory of Magnetism & Magnetic Materials 9.2 Electromagnets & Hand Rules 9.3 MMF, Flux Density, Permeability, Hysteresis & Eddy Currents
10 Inductance & Inductors
10.1 Faraday's Law & Induced Voltage 10.2 Self & Mutual Inductance, Lenz's Law 10.3 Back EMF, Saturation & Inductor Applications
11 DC Motor/Generator Theory
11.1 Basic Motor & Generator Theory 11.2 DC Generators — Construction & Operation 11.3 DC Motors — Series, Shunt, Compound & Starter-Generators
12 AC Theory
12.1 Sinusoidal Waveforms — Phase, Period, Frequency 12.2 Peak, Average, RMS Values & Calculations 12.3 Non-Sinusoidal Waves & Single/Three-Phase Principles
13 R, L & C Circuits
13.1 Phase Relationships in R, L, C Circuits 13.2 Impedance, Phase Angle & Power Factor 13.3 True, Apparent & Reactive Power
14 Transformers
14.1 Transformer Construction & Operation 14.2 Losses, Efficiency, Load/No-Load & Turns Ratio 14.3 Three-Phase Transformers & Autotransformers
15 Filters & AC Generators
15.1 Filters — Low Pass, High Pass, Band Pass, Band Stop 15.2 AC Generator Principles & Construction 15.3 Star/Delta Connections & Permanent Magnet Generators
16 AC Motors
16.1 Synchronous & Induction Motors 16.2 Speed Control, Direction & Rotating Field Methods
5.3 Series/Parallel Networks & Supply Internal Resistance
Key Takeaways Explain This Topic AI
Series resistances add: R_T = R₁ + R₂ + …; same current through each; voltages divide in proportion to resistance
Parallel conductances add: 1/R_T = 1/R₁ + 1/R₂ + …; same voltage across each; currents divide inversely with resistance
Combination networks are reduced step-by-step—identify pure series or parallel groups, replace with equivalents, then expand currents and voltages
A voltage divider produces V_out = V_in × R_bottom/(R_top + R_bottom) when unloaded (or when load ≫ divider resistance)
Supply internal resistance r causes terminal voltage V_T = E − I r to fall as load current rises—open-circuit voltage is E; loaded voltage is always lower for a passive internal r
Last updated: July 2026
5.3 Series/Parallel Networks & Supply Internal Resistance
Quick Answer: Series: R_T = ΣR, same I, voltages share. Parallel: 1/R_T = Σ(1/R), same V, currents share. Reduce combinations group by group. An unloaded divider gives V_out = V_in × R₂/(R₁+R₂) . With internal resistance r , V_terminal = E − I r , so heavier loads pull the terminals down.
Topic 3.6 finishes with the networks you actually meet on aircraft wiring and bench power supplies: strings, branches, dividers, and real sources that are not ideal voltage fonts.
Series Resistance Networks
For n resistances in series:
R_T = R₁ + R₂ + … + R_n
- Property Series behaviour
- Current Same through every element
- Voltage Splits: V_k = I R_k
- Total voltage V_T = Σ V_k = I R_T
- Worked Series Example
R₁ = 10 Ω , R₂ = 22 Ω , R₃ = 8 Ω on E = 40 V (ideal).
R_T = 10 + 22 + 8 = 40 Ω .
I = 40/40 = 1 A .
Drops: 10 V , 22 V , 8 V (sum 40 V).
- Parallel Resistance Networks
- 1/R_T = 1/R₁ + 1/R₂ + … + 1/R_n
For two resistors: R_T = (R₁ R₂)/(R₁ + R₂) .
- Property Parallel behaviour
- Voltage Same across every branch
- Current Splits: I_k = V / R_k
- Total current I_T = Σ I_k = V / R_T
R_T is always less than the smallest branch resistance.
Worked Parallel Example
R₁ = 6 Ω , R₂ = 12 Ω , R₃ = 4 Ω across 24 V .
1/R_T = 1/6 + 1/12 + 1/4 = 0.1667 + 0.0833 + 0.25 = 0.5 ⇒ R_T = 2 Ω .
I_T = 24/2 = 12 A .
Branch currents: 4 A , 2 A , 6 A (sum 12 A).
- Combination (Series–Parallel) Reduction
- Worked Combination Example
Circuit: R₁ = 5 Ω in series with a parallel pair R₂ = 20 Ω and R₃ = 30 Ω ; supply E = 50 V ideal.
Parallel pair: R₂₃ = (20 × 30)/(20 + 30) = 600/50 = 12 Ω .
R_T = 5 + 12 = 17 Ω .
I_total = 50/17 ≈ 2.941 A .
Drop on R₁: V₁ = 2.941 × 5 ≈ 14.71 V .
Parallel voltage: V₂₃ = 50 − 14.71 ≈ 35.29 V (also 2.941 × 12).
I₂ = 35.29/20 ≈ 1.765 A , I₃ = 35.29/30 ≈ 1.176 A (sum ≈ 2.941 A).
Always reduce from the inside out: combine pure parallel or series islands, redraw, repeat.
Voltage Dividers
Two resistors in series across V_in form a divider. Taking the output across the bottom resistor R₂ :
- V_out = V_in × R₂ / (R₁ + R₂) (unloaded)
- Worked Unloaded Divider
V_in = 28 V , R₁ = 3 kΩ , R₂ = 1 kΩ , output across R₂.
V_out = 28 × 1000/(3000+1000) = 28 × 0.25 = 7 V .
Loaded Divider Trap
If a load R_L = 1 kΩ connects across R₂, R₂ and R_L are in parallel first:
R₂∥L = (1×1)/(1+1) = 0.5 kΩ .
Then V_out = 28 × 0.5/(3 + 0.5) = 28 × 0.5/3.5 = 4 V .
Loading pulled the tap from 7 V down to 4 V . Exam stems that ignore the load after mentioning it are testing whether you rebuild the parallel equivalent.
Supply Internal Resistance and Terminal Voltage
A real DC source is modelled as an ideal EMF E in series with internal resistance r . External load R_L connects to the terminals.
- I = E / (R_L + r)
- V_terminal = I R_L = E − I r = E × R_L/(R_L + r)
- Condition Terminal voltage
- Open circuit (I = 0) V_T = E
- Loaded V_T = E − I r < E
- Short circuit (idealised) I → E/r, V_T → 0
- Worked Internal-r Example 1
Battery E = 24 V , r = 0.5 Ω , load R_L = 7.5 Ω .
I = 24 / (7.5 + 0.5) = 24/8 = 3 A .
V_T = 3 × 7.5 = 22.5 V .
Internal drop: I r = 1.5 V ; check 24 − 1.5 = 22.5 V .
Worked Internal-r Example 2 — Heavier Load
Same battery, now R_L = 1.5 Ω .
I = 24 / (1.5 + 0.5) = 24/2 = 12 A .
V_T = 12 × 1.5 = 18 V .
Internal drop 6 V .
Terminal voltage fell from 22.5 V to 18 V as load current rose. That is why a weak battery (higher effective r) may show near-rated open-circuit voltage on a high-impedance meter yet collapse when a starter or pump demands high current.
Worked Internal-r Example 3 — Finding r from Measurements
Open-circuit voltage measured E = 28.0 V . Under a 10 A load, terminals read 26.5 V .
I r = E − V_T = 1.5 V ⇒ r = 1.5/10 = 0.15 Ω .
This measurement pattern appears in Module 3 reasoning even when the algebra is short: open-circuit ≈ EMF; loaded sag reveals r .
Linking Networks to Internal r
Suppose E = 30 V , r = 1 Ω , and the external network is 4 Ω in series with a parallel pair of 12 Ω and 6 Ω .
Parallel: R_p = (12×6)/(12+6) = 4 Ω .
External R_L = 4 + 4 = 8 Ω .
I = 30/(8+1) = 3.333 A .
V_T = 30 − 3.333×1 ≈ 26.67 V (also 3.333 × 8).
Series 4 Ω drop ≈ 13.33 V ; parallel voltage ≈ 13.33 V ; currents 13.33/12 ≈ 1.11 A and 13.33/6 ≈ 2.22 A .
One problem used series/parallel reduction, Ohm’s law, KCL at the parallel node, and internal-resistance sag together—the full topic 3.6 skill set.
Exam Priority Checklist
Label series vs parallel vs mixed; redraw after each reduction.
For dividers, ask whether the output is loaded.
Never treat battery terminal voltage as equal to EMF under load unless r = 0 or I ≈ 0.
Sense-check: adding a parallel path always lowers R_T; adding series always raises R_T; loading a divider always lowers (or leaves equal) V_out compared with the unloaded tap.
Series/parallel arithmetic plus internal-r awareness turns Ohm and Kirchhoff from isolated laws into a complete DC-circuit toolkit for CAAS Module 3.