Study guide

9.3 MMF, Flux Density, Permeability, Hysteresis & Eddy Currents

CAAS SAR-66 AML Module 3 — Electrical Fundamentals Exam

Track your progress as you read

Finished sections get a check mark.

1 Introduction & Exam Overview

1.1 Current Exam Facts 1.2 Knowledge Levels & Study Approach for Module 3

2 Electron Theory & Static Electricity

2.1 Electron Theory & Atomic Structure 2.2 Conductors, Semiconductors & Insulators 2.3 Static Electricity, Coulomb's Law & Conduction

3 Terminology & Generation of Electricity

3.1 Electrical Terminology 3.2 Generation of Electricity

4 DC Sources of Electricity

4.1 Primary & Secondary Cells 4.2 Lead-Acid & Nickel-Cadmium Batteries 4.3 Series/Parallel Cells, Internal Resistance, Thermocouples & Photocells

5 DC Circuits

5.1 Ohm's Law 5.2 Kirchhoff's Voltage & Current Laws 5.3 Series/Parallel Networks & Supply Internal Resistance

6 Resistance & Resistors

6.1 Resistivity & Factors Affecting Resistance 6.2 Resistor Colour Code, Tolerance & Preferred Values 6.3 Series/Parallel Resistors, Potentiometers & Rheostats 6.4 Wheatstone Bridge, Thermistors & Temperature Coefficient

7 Power, Work & Energy

7.1 Power, Work & Energy Concepts 7.2 Power Dissipation & Calculations

8 Capacitance & Capacitors

8.1 Capacitor Operation & Factors Affecting Capacitance 8.2 Series/Parallel Capacitors & Types 8.3 RC Time Constants, Energy Storage & Testing

9 Magnetism

9.1 Theory of Magnetism & Magnetic Materials 9.2 Electromagnets & Hand Rules 9.3 MMF, Flux Density, Permeability, Hysteresis & Eddy Currents

10 Inductance & Inductors

10.1 Faraday's Law & Induced Voltage 10.2 Self & Mutual Inductance, Lenz's Law 10.3 Back EMF, Saturation & Inductor Applications

11 DC Motor/Generator Theory

11.1 Basic Motor & Generator Theory 11.2 DC Generators — Construction & Operation 11.3 DC Motors — Series, Shunt, Compound & Starter-Generators

12 AC Theory

12.1 Sinusoidal Waveforms — Phase, Period, Frequency 12.2 Peak, Average, RMS Values & Calculations 12.3 Non-Sinusoidal Waves & Single/Three-Phase Principles

13 R, L & C Circuits

13.1 Phase Relationships in R, L, C Circuits 13.2 Impedance, Phase Angle & Power Factor 13.3 True, Apparent & Reactive Power

14 Transformers

14.1 Transformer Construction & Operation 14.2 Losses, Efficiency, Load/No-Load & Turns Ratio 14.3 Three-Phase Transformers & Autotransformers

15 Filters & AC Generators

15.1 Filters — Low Pass, High Pass, Band Pass, Band Stop 15.2 AC Generator Principles & Construction 15.3 Star/Delta Connections & Permanent Magnet Generators

16 AC Motors

16.1 Synchronous & Induction Motors 16.2 Speed Control, Direction & Rotating Field Methods

9.3 MMF, Flux Density, Permeability, Hysteresis & Eddy Currents

Key Takeaways Explain This Topic AI

Magnetomotive force MMF = N × I (ampere-turns); magnetic field strength H is MMF per length of magnetic path (A/m)

Flux density B = Φ/A (tesla); in magnetic materials B = μH where permeability μ = μrμ0

The hysteresis loop shows B versus H through a magnetising cycle; retentivity (remanence) and coercive force are loop intercepts

Reluctance opposes flux (magnetic analogue of resistance); saturation means further H gives little rise in B

Eddy currents are induced loops in conducting cores under changing flux; laminations and ferrite cores reduce eddy-current losses

Last updated: July 2026

9.3 MMF, Flux Density, Permeability, Hysteresis & Eddy Currents

Quick Answer: MMF = NI (ampere-turns). H = NI/ℓ (A/m). B = Φ/A (T) and B = μH with μ = μrμ0 . Reluctance resists flux; saturation flattens B–H. The hysteresis loop gives remanence and coercive force . Changing flux induces eddy currents in solid cores — use laminations or ferrites to cut losses.

Qualitative magnets and hand rules are not enough for Module 3. Topic 3.10 expects the magnetic-circuit quantities, the B–H (hysteresis) story, and eddy-current losses that reappear in transformers, inductors, and AC machines.

Magnetic Quantities and Units (Memorise This Table)

  • Quantity Symbol Defining idea SI unit
  • Magnetomotive force MMF or ℱ Cause of flux in a magnetic circuit; NI ampere-turn (A)
  • Magnetic field strength H MMF per metre of path; H = NI/ℓ ampere per metre (A/m)
  • Magnetic flux Φ (phi) “Amount” of magnetism through a surface weber (Wb)
  • Flux density B Flux per unit area; B = Φ/A tesla (T) = Wb/m²
  • Permeability μ B = μH in linear media henry per metre (H/m)
  • Relative permeability μr μ = μrμ0 dimensionless
  • Free-space permeability μ0 4π × 10⁻⁷ H/m H/m
  • Reluctance ℛ Magnetic opposition; ℛ = ℓ/(μA) A/Wb (or H⁻¹)
  • Reluctance “Ohm’s law” — Φ = MMF / ℛ —

Analogy to the electric circuit (exam favourite):

  • Electric Magnetic
  • EMF (V) MMF (ampere-turns)
  • Current I Flux Φ
  • Resistance R Reluctance ℛ
  • Conductivity / low R path High μ / low ℛ path
  • Magnetomotive Force and Field Strength
  • MMF = N × I
  • N = number of turns
  • I = current in amperes
  • Product = ampere-turns

Worked example 1. A coil of 500 turns carries 0.4 A.

MMF = 500 × 0.4 = 200 ampere-turns .

If the mean magnetic path length in the core is ℓ = 0.25 m and the path is uniform:

H = MMF / ℓ = 200 / 0.25 = 800 A/m .

Field strength H depends on geometry and ampere-turns; it is not the same as flux density B . Materials respond to H by producing B according to their permeability and saturation behaviour.

Flux, Flux Density, and Permeability

Φ = B × A for uniform B perpendicular to area A , or B = Φ/A .

Worked example 2. Flux Φ = 0.006 Wb through a core cross-section A = 0.002 m².

B = 0.006 / 0.002 = 3.0 T (a high but illustrative training number — many machines run at lower peak B).

In a material (linear region):

B = μH = μrμ0 H

  • Material type Typical μr (order) Comment
  • Free space / air 1 Reference
  • Soft iron / silicon steel Hundreds to thousands Cores, good flux concentrators
  • Ferrites Tens to thousands (grade-dependent) High-frequency cores
  • Permanent-magnet materials Effective behaviour is nonlinear / different design focus Hard magnets

Worked example 3. In air, μr ≈ 1, μ0 = 4π × 10⁻⁷. For H = 800 A/m:

B ≈ μ0H ≈ 4π × 10⁻⁷ × 800 ≈ 1.0 × 10⁻³ T (about 1 mT).

Same H in soft iron with μr = 2000 would give B ≈ 2000 times larger in the linear model — until saturation intervenes. That is why cores matter.

  • Reluctance and Magnetic Circuits
  • ℛ = ℓ / (μA)
  • Change Effect on reluctance
  • Longer path ℓ ℛ increases
  • Larger area A ℛ decreases
  • Higher μ ℛ decreases
  • Air gap inserted ℛ rises sharply (μ ≈ μ0 in the gap)

Φ = MMF / ℛ — larger ampere-turns or lower reluctance → more flux.

Air-gap insight. Relay and contactor magnetic circuits include an air gap when open. Large gap → high reluctance → less flux → weaker pull until the armature closes and reluctance falls. That matches the tactile “pull-in” behaviour of many devices.

Saturation

As H increases, B rises steeply at first in ferromagnetic materials, then flattens: almost all domains are aligned. Further increases in current (H) produce little extra B . That region is magnetic saturation .

  • Consequence Practical meaning
  • Diminishing returns More coil current buys little extra flux
  • Distortion AC flux waveforms can distort when driven into saturation
  • Heating / surge currents Transformer magnetising current spikes if saturated
  • Design limit Machines and transformers are rated with peak B below deep saturation
  • Hysteresis Loop, Retentivity, and Coercive Force

Plot B against H while cycling the magnetising current through positive and negative peaks. Ferromagnetic materials trace a closed hysteresis loop , not a single-valued straight line.

  • Loop feature Meaning
  • Rising/falling paths differ B lags H — energy is dissipated per cycle ( hysteresis loss )
  • Remanence / retentivity (Br) Flux density remaining when H returns to 0 after magnetisation
  • Coercive force (Hc) Reverse H needed to drive B back to 0
  • Loop area Proportional to hysteresis energy loss per cycle per unit volume
  • Wide loop / high Hc Hard magnetic material — permanent magnets
  • Narrow loop / low Hc Soft magnetic material — cores, low hysteresis loss

Definitions in exam wording:

Retentivity (remanence): ability to retain magnetism when the magnetising force is removed — high in permanent magnets.

Coercive force (coercivity): magnetising force needed to remove residual magnetism — high in hard magnets (hard to demagnetise), low in soft cores (easy to demagnetise).

Worked concept. Soft silicon steel for a transformer: narrow loop → low hysteresis loss at 400 Hz or 50/60 Hz as applicable. Hard magnet alloy: wide loop → stays magnetised for a speaker or tach generator magnet.

Eddy Currents

A changing magnetic flux through a conducting core induces EMFs (Faraday — expanded in the inductance chapter). Those EMFs drive circulating eddy currents within the bulk metal. Eddy currents:

  • Produce I²R heating (eddy-current loss)
  • Create opposing fields (Lenz) that can be useful in damping instruments but are unwanted in transformer cores
  • Reducing eddy currents

Method How it helps

Laminated cores Thin sheets insulated from each other interrupt large eddy paths; eddy loops confined to thin laminations

  • Higher resistivity core materials Ferrites — poor electrical conductors, low eddy loss at high frequency
  • Thinner laminations Smaller eddy loop area / path → less loss (especially as frequency rises)

Aircraft angle. Many aircraft AC systems use 400 Hz . Eddy and hysteresis losses scale unfavourably with frequency if cores are poorly designed — hence laminated silicon steel or appropriate magnetic materials in transformers, instrument transformers, and machine stators/rotors.

Worked qualitative stem. “Why laminate a transformer core?” → reduce eddy currents / eddy-current loss by breaking up conducting paths perpendicular to the flux, while still providing a high-μ path for flux along the lamination plane.

Combined Loss Picture

  • Loss type Cause Reduced by
  • Hysteresis loss Domain friction / loop area each AC cycle Soft magnetic materials (narrow loop)
  • Eddy-current loss Induced loops in conducting core Laminations, ferrites, higher resistivity
  • Copper loss (preview) I²R in windings Wire size, lower current — not a core magnetic loss

Total core loss ≈ hysteresis + eddy. Module 3 wants you to name and mitigate the magnetic parts here.

Formula Drill Summary

  • Need Use
  • Ampere-turns MMF = NI
  • Field strength H = NI/ℓ
  • Flux density from flux B = Φ/A
  • Material link B = μH = μrμ0H
  • Reluctance ℛ = ℓ/(μA)
  • Flux from MMF Φ = MMF/ℛ
  • Exam Scenario Set

Scenario A — Same NI, add air gap. Reluctance up → Φ down → weaker electromagnet pull.

Scenario B — Soft vs hard on the loop. Soft: small Br and Hc after cycling used as a core. Hard: large Br — permanent magnet behaviour.

Scenario C — Solid vs laminated core at 400 Hz. Solid steel overheats from eddy currents; laminated core runs cooler for the same AC flux.

Scenario D — Saturation. Doubling current near saturation does not double B; magnetising current becomes disproportionate.

Lock the units table, the electric–magnetic analogy, loop vocabulary (retentivity / coercive force), and eddy-current laminations. Together with §9.1 materials and §9.2 electromagnets and hand rules, that is the complete Module 3 magnetism package before inductance and machines build on it.