Study guide
9.3 MMF, Flux Density, Permeability, Hysteresis & Eddy Currents
CAAS SAR-66 AML Module 3 — Electrical Fundamentals Exam
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
1.1 Current Exam Facts 1.2 Knowledge Levels & Study Approach for Module 3
2 Electron Theory & Static Electricity
2.1 Electron Theory & Atomic Structure 2.2 Conductors, Semiconductors & Insulators 2.3 Static Electricity, Coulomb's Law & Conduction
3 Terminology & Generation of Electricity
3.1 Electrical Terminology 3.2 Generation of Electricity
4 DC Sources of Electricity
4.1 Primary & Secondary Cells 4.2 Lead-Acid & Nickel-Cadmium Batteries 4.3 Series/Parallel Cells, Internal Resistance, Thermocouples & Photocells
5 DC Circuits
5.1 Ohm's Law 5.2 Kirchhoff's Voltage & Current Laws 5.3 Series/Parallel Networks & Supply Internal Resistance
6 Resistance & Resistors
6.1 Resistivity & Factors Affecting Resistance 6.2 Resistor Colour Code, Tolerance & Preferred Values 6.3 Series/Parallel Resistors, Potentiometers & Rheostats 6.4 Wheatstone Bridge, Thermistors & Temperature Coefficient
7 Power, Work & Energy
7.1 Power, Work & Energy Concepts 7.2 Power Dissipation & Calculations
8 Capacitance & Capacitors
8.1 Capacitor Operation & Factors Affecting Capacitance 8.2 Series/Parallel Capacitors & Types 8.3 RC Time Constants, Energy Storage & Testing
9 Magnetism
9.1 Theory of Magnetism & Magnetic Materials 9.2 Electromagnets & Hand Rules 9.3 MMF, Flux Density, Permeability, Hysteresis & Eddy Currents
10 Inductance & Inductors
10.1 Faraday's Law & Induced Voltage 10.2 Self & Mutual Inductance, Lenz's Law 10.3 Back EMF, Saturation & Inductor Applications
11 DC Motor/Generator Theory
11.1 Basic Motor & Generator Theory 11.2 DC Generators — Construction & Operation 11.3 DC Motors — Series, Shunt, Compound & Starter-Generators
12 AC Theory
12.1 Sinusoidal Waveforms — Phase, Period, Frequency 12.2 Peak, Average, RMS Values & Calculations 12.3 Non-Sinusoidal Waves & Single/Three-Phase Principles
13 R, L & C Circuits
13.1 Phase Relationships in R, L, C Circuits 13.2 Impedance, Phase Angle & Power Factor 13.3 True, Apparent & Reactive Power
14 Transformers
14.1 Transformer Construction & Operation 14.2 Losses, Efficiency, Load/No-Load & Turns Ratio 14.3 Three-Phase Transformers & Autotransformers
15 Filters & AC Generators
15.1 Filters — Low Pass, High Pass, Band Pass, Band Stop 15.2 AC Generator Principles & Construction 15.3 Star/Delta Connections & Permanent Magnet Generators
16 AC Motors
16.1 Synchronous & Induction Motors 16.2 Speed Control, Direction & Rotating Field Methods
9.3 MMF, Flux Density, Permeability, Hysteresis & Eddy Currents
Key Takeaways Explain This Topic AI
Magnetomotive force MMF = N × I (ampere-turns); magnetic field strength H is MMF per length of magnetic path (A/m)
Flux density B = Φ/A (tesla); in magnetic materials B = μH where permeability μ = μrμ0
The hysteresis loop shows B versus H through a magnetising cycle; retentivity (remanence) and coercive force are loop intercepts
Reluctance opposes flux (magnetic analogue of resistance); saturation means further H gives little rise in B
Eddy currents are induced loops in conducting cores under changing flux; laminations and ferrite cores reduce eddy-current losses
Last updated: July 2026
9.3 MMF, Flux Density, Permeability, Hysteresis & Eddy Currents
Quick Answer: MMF = NI (ampere-turns). H = NI/ℓ (A/m). B = Φ/A (T) and B = μH with μ = μrμ0 . Reluctance resists flux; saturation flattens B–H. The hysteresis loop gives remanence and coercive force . Changing flux induces eddy currents in solid cores — use laminations or ferrites to cut losses.
Qualitative magnets and hand rules are not enough for Module 3. Topic 3.10 expects the magnetic-circuit quantities, the B–H (hysteresis) story, and eddy-current losses that reappear in transformers, inductors, and AC machines.
Magnetic Quantities and Units (Memorise This Table)
- Quantity Symbol Defining idea SI unit
- Magnetomotive force MMF or ℱ Cause of flux in a magnetic circuit; NI ampere-turn (A)
- Magnetic field strength H MMF per metre of path; H = NI/ℓ ampere per metre (A/m)
- Magnetic flux Φ (phi) “Amount” of magnetism through a surface weber (Wb)
- Flux density B Flux per unit area; B = Φ/A tesla (T) = Wb/m²
- Permeability μ B = μH in linear media henry per metre (H/m)
- Relative permeability μr μ = μrμ0 dimensionless
- Free-space permeability μ0 4π × 10⁻⁷ H/m H/m
- Reluctance ℛ Magnetic opposition; ℛ = ℓ/(μA) A/Wb (or H⁻¹)
- Reluctance “Ohm’s law” — Φ = MMF / ℛ —
Analogy to the electric circuit (exam favourite):
- Electric Magnetic
- EMF (V) MMF (ampere-turns)
- Current I Flux Φ
- Resistance R Reluctance ℛ
- Conductivity / low R path High μ / low ℛ path
- Magnetomotive Force and Field Strength
- MMF = N × I
- N = number of turns
- I = current in amperes
- Product = ampere-turns
Worked example 1. A coil of 500 turns carries 0.4 A.
MMF = 500 × 0.4 = 200 ampere-turns .
If the mean magnetic path length in the core is ℓ = 0.25 m and the path is uniform:
H = MMF / ℓ = 200 / 0.25 = 800 A/m .
Field strength H depends on geometry and ampere-turns; it is not the same as flux density B . Materials respond to H by producing B according to their permeability and saturation behaviour.
Flux, Flux Density, and Permeability
Φ = B × A for uniform B perpendicular to area A , or B = Φ/A .
Worked example 2. Flux Φ = 0.006 Wb through a core cross-section A = 0.002 m².
B = 0.006 / 0.002 = 3.0 T (a high but illustrative training number — many machines run at lower peak B).
In a material (linear region):
B = μH = μrμ0 H
- Material type Typical μr (order) Comment
- Free space / air 1 Reference
- Soft iron / silicon steel Hundreds to thousands Cores, good flux concentrators
- Ferrites Tens to thousands (grade-dependent) High-frequency cores
- Permanent-magnet materials Effective behaviour is nonlinear / different design focus Hard magnets
Worked example 3. In air, μr ≈ 1, μ0 = 4π × 10⁻⁷. For H = 800 A/m:
B ≈ μ0H ≈ 4π × 10⁻⁷ × 800 ≈ 1.0 × 10⁻³ T (about 1 mT).
Same H in soft iron with μr = 2000 would give B ≈ 2000 times larger in the linear model — until saturation intervenes. That is why cores matter.
- Reluctance and Magnetic Circuits
- ℛ = ℓ / (μA)
- Change Effect on reluctance
- Longer path ℓ ℛ increases
- Larger area A ℛ decreases
- Higher μ ℛ decreases
- Air gap inserted ℛ rises sharply (μ ≈ μ0 in the gap)
Φ = MMF / ℛ — larger ampere-turns or lower reluctance → more flux.
Air-gap insight. Relay and contactor magnetic circuits include an air gap when open. Large gap → high reluctance → less flux → weaker pull until the armature closes and reluctance falls. That matches the tactile “pull-in” behaviour of many devices.
Saturation
As H increases, B rises steeply at first in ferromagnetic materials, then flattens: almost all domains are aligned. Further increases in current (H) produce little extra B . That region is magnetic saturation .
- Consequence Practical meaning
- Diminishing returns More coil current buys little extra flux
- Distortion AC flux waveforms can distort when driven into saturation
- Heating / surge currents Transformer magnetising current spikes if saturated
- Design limit Machines and transformers are rated with peak B below deep saturation
- Hysteresis Loop, Retentivity, and Coercive Force
Plot B against H while cycling the magnetising current through positive and negative peaks. Ferromagnetic materials trace a closed hysteresis loop , not a single-valued straight line.
- Loop feature Meaning
- Rising/falling paths differ B lags H — energy is dissipated per cycle ( hysteresis loss )
- Remanence / retentivity (Br) Flux density remaining when H returns to 0 after magnetisation
- Coercive force (Hc) Reverse H needed to drive B back to 0
- Loop area Proportional to hysteresis energy loss per cycle per unit volume
- Wide loop / high Hc Hard magnetic material — permanent magnets
- Narrow loop / low Hc Soft magnetic material — cores, low hysteresis loss
Definitions in exam wording:
Retentivity (remanence): ability to retain magnetism when the magnetising force is removed — high in permanent magnets.
Coercive force (coercivity): magnetising force needed to remove residual magnetism — high in hard magnets (hard to demagnetise), low in soft cores (easy to demagnetise).
Worked concept. Soft silicon steel for a transformer: narrow loop → low hysteresis loss at 400 Hz or 50/60 Hz as applicable. Hard magnet alloy: wide loop → stays magnetised for a speaker or tach generator magnet.
Eddy Currents
A changing magnetic flux through a conducting core induces EMFs (Faraday — expanded in the inductance chapter). Those EMFs drive circulating eddy currents within the bulk metal. Eddy currents:
- Produce I²R heating (eddy-current loss)
- Create opposing fields (Lenz) that can be useful in damping instruments but are unwanted in transformer cores
- Reducing eddy currents
Method How it helps
Laminated cores Thin sheets insulated from each other interrupt large eddy paths; eddy loops confined to thin laminations
- Higher resistivity core materials Ferrites — poor electrical conductors, low eddy loss at high frequency
- Thinner laminations Smaller eddy loop area / path → less loss (especially as frequency rises)
Aircraft angle. Many aircraft AC systems use 400 Hz . Eddy and hysteresis losses scale unfavourably with frequency if cores are poorly designed — hence laminated silicon steel or appropriate magnetic materials in transformers, instrument transformers, and machine stators/rotors.
Worked qualitative stem. “Why laminate a transformer core?” → reduce eddy currents / eddy-current loss by breaking up conducting paths perpendicular to the flux, while still providing a high-μ path for flux along the lamination plane.
Combined Loss Picture
- Loss type Cause Reduced by
- Hysteresis loss Domain friction / loop area each AC cycle Soft magnetic materials (narrow loop)
- Eddy-current loss Induced loops in conducting core Laminations, ferrites, higher resistivity
- Copper loss (preview) I²R in windings Wire size, lower current — not a core magnetic loss
Total core loss ≈ hysteresis + eddy. Module 3 wants you to name and mitigate the magnetic parts here.
Formula Drill Summary
- Need Use
- Ampere-turns MMF = NI
- Field strength H = NI/ℓ
- Flux density from flux B = Φ/A
- Material link B = μH = μrμ0H
- Reluctance ℛ = ℓ/(μA)
- Flux from MMF Φ = MMF/ℛ
- Exam Scenario Set
Scenario A — Same NI, add air gap. Reluctance up → Φ down → weaker electromagnet pull.
Scenario B — Soft vs hard on the loop. Soft: small Br and Hc after cycling used as a core. Hard: large Br — permanent magnet behaviour.
Scenario C — Solid vs laminated core at 400 Hz. Solid steel overheats from eddy currents; laminated core runs cooler for the same AC flux.
Scenario D — Saturation. Doubling current near saturation does not double B; magnetising current becomes disproportionate.
Lock the units table, the electric–magnetic analogy, loop vocabulary (retentivity / coercive force), and eddy-current laminations. Together with §9.1 materials and §9.2 electromagnets and hand rules, that is the complete Module 3 magnetism package before inductance and machines build on it.