Study guide
13.2 Impedance, Phase Angle & Power Factor
CAAS SAR-66 AML Module 3 — Electrical Fundamentals Exam
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
1.1 Current Exam Facts 1.2 Knowledge Levels & Study Approach for Module 3
2 Electron Theory & Static Electricity
2.1 Electron Theory & Atomic Structure 2.2 Conductors, Semiconductors & Insulators 2.3 Static Electricity, Coulomb's Law & Conduction
3 Terminology & Generation of Electricity
3.1 Electrical Terminology 3.2 Generation of Electricity
4 DC Sources of Electricity
4.1 Primary & Secondary Cells 4.2 Lead-Acid & Nickel-Cadmium Batteries 4.3 Series/Parallel Cells, Internal Resistance, Thermocouples & Photocells
5 DC Circuits
5.1 Ohm's Law 5.2 Kirchhoff's Voltage & Current Laws 5.3 Series/Parallel Networks & Supply Internal Resistance
6 Resistance & Resistors
6.1 Resistivity & Factors Affecting Resistance 6.2 Resistor Colour Code, Tolerance & Preferred Values 6.3 Series/Parallel Resistors, Potentiometers & Rheostats 6.4 Wheatstone Bridge, Thermistors & Temperature Coefficient
7 Power, Work & Energy
7.1 Power, Work & Energy Concepts 7.2 Power Dissipation & Calculations
8 Capacitance & Capacitors
8.1 Capacitor Operation & Factors Affecting Capacitance 8.2 Series/Parallel Capacitors & Types 8.3 RC Time Constants, Energy Storage & Testing
9 Magnetism
9.1 Theory of Magnetism & Magnetic Materials 9.2 Electromagnets & Hand Rules 9.3 MMF, Flux Density, Permeability, Hysteresis & Eddy Currents
10 Inductance & Inductors
10.1 Faraday's Law & Induced Voltage 10.2 Self & Mutual Inductance, Lenz's Law 10.3 Back EMF, Saturation & Inductor Applications
11 DC Motor/Generator Theory
11.1 Basic Motor & Generator Theory 11.2 DC Generators — Construction & Operation 11.3 DC Motors — Series, Shunt, Compound & Starter-Generators
12 AC Theory
12.1 Sinusoidal Waveforms — Phase, Period, Frequency 12.2 Peak, Average, RMS Values & Calculations 12.3 Non-Sinusoidal Waves & Single/Three-Phase Principles
13 R, L & C Circuits
13.1 Phase Relationships in R, L, C Circuits 13.2 Impedance, Phase Angle & Power Factor 13.3 True, Apparent & Reactive Power
14 Transformers
14.1 Transformer Construction & Operation 14.2 Losses, Efficiency, Load/No-Load & Turns Ratio 14.3 Three-Phase Transformers & Autotransformers
15 Filters & AC Generators
15.1 Filters — Low Pass, High Pass, Band Pass, Band Stop 15.2 AC Generator Principles & Construction 15.3 Star/Delta Connections & Permanent Magnet Generators
16 AC Motors
16.1 Synchronous & Induction Motors 16.2 Speed Control, Direction & Rotating Field Methods
13.2 Impedance, Phase Angle & Power Factor
Key Takeaways Explain This Topic AI
Series impedance magnitude is Z = √(R² + X²) where net X = X_L − X_C; current is I = V / Z
Phase angle θ satisfies tan θ = X/R (or cos θ = R/Z); sign shows inductive lag or capacitive lead
Power factor pf = cos θ = R/Z (lagging if net inductive, leading if net capacitive)
At series resonance X_L = X_C, so Z ≈ R (minimum for series) and pf ≈ 1
- Always compute X_L and X_C at the stated frequency — 400 Hz changes Z dramatically versus 50/60 Hz
- Last updated: July 2026
13.2 Impedance, Phase Angle & Power Factor
Quick Answer: Impedance Z is the AC opposition combining R and net reactance: for series, Z = √(R² + (X_L − X_C)²) . I = V / Z . Phase angle θ from tan θ = X/R or cos θ = R/Z . Power factor = cos θ = R/Z . At series resonance X_L = X_C and Z ≈ R .
Section 13.1 fixed phase and reactance for pure elements. Module 3 topic 3.14 next demands quantitative impedance , the angle between supply voltage and current, and power factor —the bridge into true/apparent/reactive power in §13.3.
Impedance Defined
Impedance Z is the generalisation of resistance for sine AC circuits that may include L and C. Its SI unit is the ohm . Magnitude tells how large the current is for a given voltage; angle tells how far current sits from voltage in phase.
In rectangular (Module 3 working) form for a series combination:
Z = R + jX
where net reactance X = X_L − X_C (positive X → inductive; negative X → capacitive).
Magnitude:
|Z| = √(R² + X²) = √(R² + (X_L − X_C)²)
Often written simply Z for the magnitude in technician calculations.
Ohm’s law for AC (RMS):
- I = V / Z
- V = I Z
- Worked example 1 — series RL at 400 Hz
R = 30 Ω, L = 20 mH, f = 400 Hz, V = 115 V RMS.
X_L = 2π × 400 × 0.020 = 2π × 8 ≈ 50.27 Ω .
Z = √(30² + 50.27²) = √(900 + 2527) ≈ √3427 ≈ 58.5 Ω .
I = 115 / 58.5 ≈ 1.97 A RMS .
Worked example 2 — series RC at 400 Hz
R = 40 Ω, C = 20 µF, f = 400 Hz, V = 115 V RMS.
X_C = 1 / (2π × 400 × 20 × 10⁻⁶) = 1 / (0.05027) ≈ 19.9 Ω .
Z = √(40² + 19.9²) ≈ √(1600 + 396) ≈ √1996 ≈ 44.7 Ω .
I = 115 / 44.7 ≈ 2.57 A RMS .
Worked example 3 — series RLC
R = 25 Ω, X_L = 60 Ω, X_C = 20 Ω (already at operating frequency), V = 100 V RMS.
X = 60 − 20 = 40 Ω (inductive).
Z = √(25² + 40²) = √(625 + 1600) = √2225 ≈ 47.2 Ω .
I = 100 / 47.2 ≈ 2.12 A .
Trap: Using Z = R + X_L + X_C = 105 Ω as a scalar sum is wrong — reactances cancel partially and combine under the square root with R.
Phase Angle
The angle θ between supply voltage and current (series circuit, current as reference often):
- tan θ = X / R = (X_L − X_C) / R
- cos θ = R / Z
- sin θ = X / Z
- Net X Current relative to voltage Typical label
- X > 0 (X_L > X_C) I lags V Inductive, lagging pf
- X < 0 (X_C > X_L) I leads V Capacitive, leading pf
- X = 0 I in phase with V Resistive / resonance
Worked example 4 — angle from example 3. R = 25 Ω, X = 40 Ω, Z ≈ 47.2 Ω.
cos θ = 25 / 47.2 ≈ 0.529 → θ ≈ 58° lagging (inductive).
tan θ = 40/25 = 1.6 → θ = tan⁻¹(1.6) ≈ 58° (same).
Worked example 5 — capacitive angle. R = 40 Ω, X = −19.9 Ω (from example 2), Z ≈ 44.7 Ω.
cos θ = 40 / 44.7 ≈ 0.895 → θ ≈ 26.5° leading.
Power Factor
Power factor (pf) measures how effectively the apparent volt-amperes deliver true power:
pf = cos θ = P / S
For the series model used in Module 3:
pf = R / Z
- pf value Meaning
- 1.0 (unity) Purely resistive (or resonant series with X = 0)
- 0.8 lagging Inductive load; current lags; common motor/transformer language
- 0.8 leading Capacitive net; current leads
- 0 Pure reactive — no average true power
State lagging or leading with the number when the stem asks for complete pf.
Worked example 6 — pf from Z. From example 1: R = 30 Ω, Z ≈ 58.5 Ω.
pf = 30 / 58.5 ≈ 0.513 lagging .
Worked example 7 — find R from pf. A series circuit has Z = 50 Ω and pf = 0.8 lagging.
R = pf × Z = 0.8 × 50 = 40 Ω .
Then |X| = √(Z² − R²) = √(2500 − 1600) = √900 = 30 Ω (inductive because lagging).
Current Calculations — Drill Pattern
Standard Module 3 path for a series branch:
Compute X_L = 2πfL and/or X_C = 1/(2πfC) at the given f (use 400 Hz on aircraft).
Net X = X_L − X_C .
Z = √(R² + X²) .
I = V / Z .
θ from cos⁻¹(R/Z) or tan⁻¹(X/R); name lead/lag.
pf = cos θ = R/Z .
Worked example 8 — full 400 Hz chain. Series R = 15 Ω, L = 8 mH, C = 25 µF; V = 115 V RMS; f = 400 Hz.
X_L = 2π × 400 × 0.008 ≈ 20.11 Ω .
X_C = 1 / (2π × 400 × 25 × 10⁻⁶) ≈ 15.92 Ω .
X = 20.11 − 15.92 ≈ 4.19 Ω (slightly inductive).
Z = √(15² + 4.19²) ≈ √(225 + 17.6) ≈ √242.6 ≈ 15.6 Ω .
I = 115 / 15.6 ≈ 7.38 A .
pf = 15 / 15.6 ≈ 0.962 lagging ; θ ≈ 16° .
Notice how close X_L and X_C are: Z is only slightly above R — a preview of resonance.
Resonance (Brief — Series)
Series resonance occurs when X_L = X_C :
2πfL = 1/(2πfC) → f₀ = 1 / (2π√(LC))
At that frequency:
- Net X = 0
- Z = R (minimum impedance for a series RLC)
- I = V / R (maximum current for fixed V)
- θ = 0° , pf = 1 (unity)
Worked example 9 — Z at resonance. Series R = 12 Ω, L and C such that X_L = X_C = 80 Ω at the operating frequency.
Z = √(12² + 0²) = 12 Ω ≈ R . Large equal reactances cancel; only R limits current.
Module 3 may only ask you to recognise “at resonance Z equals R” and pf is unity. Deep Q-factor bandwidth belongs with filters later; here the exam hook is Z ≈ R when X_L = X_C.
Parallel Impedance (Recognition Level)
For a simple parallel RL or RC, it is often easier to work in currents (shared V) or admittances. Equivalent impedance magnitude is not √(R² + X²) of the branch values added the series way. If a stem gives parallel data, find branch currents, phasor-sum them, then Z_eq = V / I_total . Do not force the series formula onto a parallel schematic.
Common Exam Traps
Forgetting to subtract X_C from X_L (or vice versa) before squaring.
Computing X at 50 Hz when the aircraft bus is 400 Hz.
Reporting pf as R/X instead of R/Z.
Omitting “lagging” / “leading.”
Claiming Z = R + X_L as a scalar.
Section Synthesis
- Quantity Series formula (Module 3 core)
- Net X X_L − X_C
- Z √(R² + X²)
- I V / Z
- cos θ / pf R / Z
- Resonance X_L = X_C → Z = R, pf = 1
With Z, θ, and pf fluent, §13.3 splits power into true P , apparent S , and reactive Q on the power triangle.