Study guide
13.1 Phase Relationships in R, L, C Circuits
CAAS SAR-66 AML Module 3 — Electrical Fundamentals Exam
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
1.1 Current Exam Facts 1.2 Knowledge Levels & Study Approach for Module 3
2 Electron Theory & Static Electricity
2.1 Electron Theory & Atomic Structure 2.2 Conductors, Semiconductors & Insulators 2.3 Static Electricity, Coulomb's Law & Conduction
3 Terminology & Generation of Electricity
3.1 Electrical Terminology 3.2 Generation of Electricity
4 DC Sources of Electricity
4.1 Primary & Secondary Cells 4.2 Lead-Acid & Nickel-Cadmium Batteries 4.3 Series/Parallel Cells, Internal Resistance, Thermocouples & Photocells
5 DC Circuits
5.1 Ohm's Law 5.2 Kirchhoff's Voltage & Current Laws 5.3 Series/Parallel Networks & Supply Internal Resistance
6 Resistance & Resistors
6.1 Resistivity & Factors Affecting Resistance 6.2 Resistor Colour Code, Tolerance & Preferred Values 6.3 Series/Parallel Resistors, Potentiometers & Rheostats 6.4 Wheatstone Bridge, Thermistors & Temperature Coefficient
7 Power, Work & Energy
7.1 Power, Work & Energy Concepts 7.2 Power Dissipation & Calculations
8 Capacitance & Capacitors
8.1 Capacitor Operation & Factors Affecting Capacitance 8.2 Series/Parallel Capacitors & Types 8.3 RC Time Constants, Energy Storage & Testing
9 Magnetism
9.1 Theory of Magnetism & Magnetic Materials 9.2 Electromagnets & Hand Rules 9.3 MMF, Flux Density, Permeability, Hysteresis & Eddy Currents
10 Inductance & Inductors
10.1 Faraday's Law & Induced Voltage 10.2 Self & Mutual Inductance, Lenz's Law 10.3 Back EMF, Saturation & Inductor Applications
11 DC Motor/Generator Theory
11.1 Basic Motor & Generator Theory 11.2 DC Generators — Construction & Operation 11.3 DC Motors — Series, Shunt, Compound & Starter-Generators
12 AC Theory
12.1 Sinusoidal Waveforms — Phase, Period, Frequency 12.2 Peak, Average, RMS Values & Calculations 12.3 Non-Sinusoidal Waves & Single/Three-Phase Principles
13 R, L & C Circuits
13.1 Phase Relationships in R, L, C Circuits 13.2 Impedance, Phase Angle & Power Factor 13.3 True, Apparent & Reactive Power
14 Transformers
14.1 Transformer Construction & Operation 14.2 Losses, Efficiency, Load/No-Load & Turns Ratio 14.3 Three-Phase Transformers & Autotransformers
15 Filters & AC Generators
15.1 Filters — Low Pass, High Pass, Band Pass, Band Stop 15.2 AC Generator Principles & Construction 15.3 Star/Delta Connections & Permanent Magnet Generators
16 AC Motors
16.1 Synchronous & Induction Motors 16.2 Speed Control, Direction & Rotating Field Methods
13.1 Phase Relationships in R, L, C Circuits
Key Takeaways Explain This Topic AI
In a pure resistor, voltage and current are in phase (θ = 0°); instantaneous peaks occur together
In a pure inductor, voltage leads current by 90° (ELI); inductive reactance is X_L = 2πfL
In a pure capacitor, current leads voltage by 90° (ICE); capacitive reactance is X_C = 1/(2πfC)
Series RLC shares one current; voltages add as phasors. Parallel RLC shares one voltage; currents add as phasors
At aircraft 400 Hz, X_L is much larger and X_C much smaller than at 50/60 Hz for the same L or C — frequency always enters reactance
Last updated: July 2026
13.1 Phase Relationships in R, L, C Circuits
Quick Answer: Pure R : V and I in phase . Pure L : V leads I by 90° ( ELI ); X_L = 2πfL . Pure C : I leads V by 90° ( ICE ); X_C = 1/(2πfC) . Series circuits share current ; parallel circuits share voltage . Combine phasors, not arithmetic sums of peaks, when R, L, and C sit together.
CAAS SAR-66 Module 3 topic 3.14 R, C and L Circuits follows AC theory (3.13). You already know sinusoids, RMS, and phase language. This chapter asks what happens when those waves drive resistance , inductance , and capacitance —alone and in combination. Phase shift and reactance are the foundation for impedance, power factor, and the power triangle in §§13.2–13.3.
Pure Resistance — Voltage and Current in Phase
Ohm’s law still holds with RMS (or peak) values for a linear resistor on sine AC:
- I = V / R
- V = I R
Because v = iR at every instant, the voltage and current waveforms reach zero and peak together . Phase angle between V and I is θ = 0° . Instantaneous power is always non-negative for a pure resistor (or zero at the zeros); average power is P = V_RMS I_RMS = I_RMS² R .
- Quantity Pure R behaviour
- Phase V and I in phase
- Opposition to AC Resistance R (ohms) — independent of frequency for an ideal resistor
- Power Dissipates true power as heat
Worked example 1 — resistive branch at 400 Hz. A heater of R = 23 Ω is fed from 115 V RMS aircraft AC (frequency does not change R).
I = 115 / 23 = 5.0 A RMS . Voltage and current are in phase. P = 115 × 5.0 = 575 W .
Pure Inductance — Voltage Leads Current by 90°
An ideal inductor stores energy in its magnetic field. For sinusoidal current, the self-induced voltage is proportional to di/dt . Differentiating a sine advances it by 90°, so:
Voltage leads current by 90° (equivalently, current lags voltage by 90° ).
Memory aid ELI : voltage E across L , then I — E before I.
The opposition of an ideal inductor to sine AC is inductive reactance :
X_L = 2πfL = ωL
- Symbol Meaning SI unit
- X_L Inductive reactance ohm (Ω)
- f Frequency hertz (Hz)
- L Inductance henry (H)
- ω Angular frequency = 2πf rad/s
Ohm’s-law form for magnitude: V_L = I X_L (RMS with RMS).
Worked example 2 — X_L at 400 Hz. L = 10 mH = 0.010 H; f = 400 Hz.
X_L = 2π × 400 × 0.010 = 2π × 4 = 25.13 Ω ≈ 25.1 Ω .
Worked example 3 — same L at 50 Hz (trap comparison). X_L = 2π × 50 × 0.010 ≈ 3.14 Ω . At aircraft frequency the same choke looks about eight times “stiffer” (400/50 = 8).
Worked example 4 — current in pure L. 115 V RMS across that 10 mH inductor at 400 Hz.
I = V / X_L = 115 / 25.13 ≈ 4.58 A RMS . Current lags voltage by 90° . Ideal average true power is zero (energy oscillates to and from the field each cycle).
Pure Capacitance — Current Leads Voltage by 90°
An ideal capacitor’s current is proportional to dv/dt . Differentiating voltage advances current by 90°, so:
Current leads voltage by 90° (equivalently, voltage lags current by 90° ).
Memory aid ICE : current I through C , then E — I before E.
Capacitive reactance:
X_C = 1 / (2πfC) = 1 / (ωC)
- Symbol Meaning SI unit
- X_C Capacitive reactance ohm (Ω)
- C Capacitance farad (F)
V_C = I X_C (RMS form).
Worked example 5 — X_C at 400 Hz. C = 10 µF = 10 × 10⁻⁶ F; f = 400 Hz.
X_C = 1 / (2π × 400 × 10 × 10⁻⁶) = 1 / (2π × 4 × 10⁻³) = 1 / (0.02513) ≈ 39.8 Ω .
Worked example 6 — same C at 50 Hz. X_C = 1 / (2π × 50 × 10 × 10⁻⁶) ≈ 318 Ω . Higher frequency lowers X_C — the capacitor passes AC more easily at 400 Hz than at utility frequency.
Worked example 7 — current in pure C. 115 V RMS across 10 µF at 400 Hz.
I = 115 / 39.8 ≈ 2.89 A RMS . Current leads voltage by 90° . Ideal average true power is again zero .
Reactance Summary Table
- Element Phase (V vs I) Reactance / resistance Frequency effect
- Pure R In phase (0°) R Ideal R independent of f
- Pure L V leads I by 90° (ELI) X_L = 2πfL X_L rises with f
- Pure C I leads V by 90° (ICE) X_C = 1/(2πfC) X_C falls with f
Exam discipline: Never add X_L and X_C as if they were the same kind of opposition without a sign/phasor rule — they oppose each other in series (next section). Always use f = 400 Hz on aircraft stems unless told otherwise.
Series Combination Overview
In a series R, L, C path there is one current through every element. Element voltages differ in phase:
- V_R in phase with I
- V_L leads I by 90°
- V_C lags I by 90° (or V_C is 180° from V_L along the reactive axis)
Supply voltage is the phasor sum of the element voltages — not V_R + V_L + V_C as scalars. Net reactive voltage is often written V_L − V_C (magnitudes) along the ±j axis, then combined with V_R:
V = √(V_R² + (V_L − V_C)²)
Worked example 8 — series intuition at 400 Hz. Series R = 30 Ω, X_L = 40 Ω, X_C = 10 Ω; I = 2 A RMS.
V_R = 2 × 30 = 60 V; V_L = 80 V; V_C = 20 V.
Net reactive drop = 80 − 20 = 60 V.
V_supply = √(60² + 60²) = 60√2 ≈ 84.9 V . Current lags the supply voltage (inductive net) — full Z and θ follow in §13.2.
Parallel Combination Overview
In a parallel R, L, C network the same voltage appears across each branch. Branch currents differ in phase:
- I_R in phase with V
- I_L lags V by 90°
- I_C leads V by 90°
Total current is the phasor sum of branch currents:
I = √(I_R² + (I_C − I_L)²) (common Module 3 form when comparing capacitive and inductive branch currents)
Worked example 9 — parallel sketch at 400 Hz. 115 V RMS across parallel R = 57.5 Ω and L with X_L = 57.5 Ω.
I_R = 115 / 57.5 = 2.0 A (in phase with V).
I_L = 115 / 57.5 = 2.0 A (lags V by 90°).
I_total = √(2² + 2²) = 2√2 ≈ 2.83 A . Supply current lags voltage — inductive parallel mix.
Series-Parallel Overview
Real aircraft wiring often mixes topologies: a series RL feed into a parallel capacitive filter branch, or a resistor in series with a parallel LC tank. Method for Module 3:
Reduce each pure series or parallel group to an equivalent impedance (or admittance) using phasors.
Combine the equivalents step by step toward the source.
Keep one reference phasor clear — usually series current or parallel voltage.
You do not need every exotic network on the first pass; you do need to refuse scalar addition of out-of-phase voltages or currents.
Aircraft 400 Hz Context
- Why 400 Hz matters here
- Same L → larger X_L than at 50/60 Hz → more voltage drop / stronger choke action
- Same C → smaller X_C → capacitors bypass AC more readily
- Resonant frequencies of LC pairs sit differently than on utility power
- Filters and power-factor behaviour (later topics) are sized for 400 Hz
- Section Synthesis
- Circuit Shared quantity Phase rule to memorise
- Pure R — V ∥ I
- Pure L — V leads I 90°; X_L = 2πfL
- Pure C — I leads V 90°; X_C = 1/(2πfC)
- Series RLC Current I Voltages add as phasors
- Parallel RLC Voltage V Currents add as phasors
Lock ELI / ICE and the two reactance formulae with 400 Hz drills. Section 13.2 packs them into impedance Z , phase angle , and power factor .