Study guide
3.1 Electrical Terminology
CAAS SAR-66 AML Module 3 — Electrical Fundamentals Exam
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
1.1 Current Exam Facts 1.2 Knowledge Levels & Study Approach for Module 3
2 Electron Theory & Static Electricity
2.1 Electron Theory & Atomic Structure 2.2 Conductors, Semiconductors & Insulators 2.3 Static Electricity, Coulomb's Law & Conduction
3 Terminology & Generation of Electricity
3.1 Electrical Terminology 3.2 Generation of Electricity
4 DC Sources of Electricity
4.1 Primary & Secondary Cells 4.2 Lead-Acid & Nickel-Cadmium Batteries 4.3 Series/Parallel Cells, Internal Resistance, Thermocouples & Photocells
5 DC Circuits
5.1 Ohm's Law 5.2 Kirchhoff's Voltage & Current Laws 5.3 Series/Parallel Networks & Supply Internal Resistance
6 Resistance & Resistors
6.1 Resistivity & Factors Affecting Resistance 6.2 Resistor Colour Code, Tolerance & Preferred Values 6.3 Series/Parallel Resistors, Potentiometers & Rheostats 6.4 Wheatstone Bridge, Thermistors & Temperature Coefficient
7 Power, Work & Energy
7.1 Power, Work & Energy Concepts 7.2 Power Dissipation & Calculations
8 Capacitance & Capacitors
8.1 Capacitor Operation & Factors Affecting Capacitance 8.2 Series/Parallel Capacitors & Types 8.3 RC Time Constants, Energy Storage & Testing
9 Magnetism
9.1 Theory of Magnetism & Magnetic Materials 9.2 Electromagnets & Hand Rules 9.3 MMF, Flux Density, Permeability, Hysteresis & Eddy Currents
10 Inductance & Inductors
10.1 Faraday's Law & Induced Voltage 10.2 Self & Mutual Inductance, Lenz's Law 10.3 Back EMF, Saturation & Inductor Applications
11 DC Motor/Generator Theory
11.1 Basic Motor & Generator Theory 11.2 DC Generators — Construction & Operation 11.3 DC Motors — Series, Shunt, Compound & Starter-Generators
12 AC Theory
12.1 Sinusoidal Waveforms — Phase, Period, Frequency 12.2 Peak, Average, RMS Values & Calculations 12.3 Non-Sinusoidal Waves & Single/Three-Phase Principles
13 R, L & C Circuits
13.1 Phase Relationships in R, L, C Circuits 13.2 Impedance, Phase Angle & Power Factor 13.3 True, Apparent & Reactive Power
14 Transformers
14.1 Transformer Construction & Operation 14.2 Losses, Efficiency, Load/No-Load & Turns Ratio 14.3 Three-Phase Transformers & Autotransformers
15 Filters & AC Generators
15.1 Filters — Low Pass, High Pass, Band Pass, Band Stop 15.2 AC Generator Principles & Construction 15.3 Star/Delta Connections & Permanent Magnet Generators
16 AC Motors
16.1 Synchronous & Induction Motors 16.2 Speed Control, Direction & Rotating Field Methods
3.1 Electrical Terminology
Key Takeaways Explain This Topic AI
Potential difference (voltage) is measured in volts (V); EMF is the source voltage that drives current around a closed circuit
Current is the rate of charge flow in amperes (A); conventional current is positive-to-negative while electron flow is the opposite direction
Resistance (ohms, Ω) opposes current; conductance (siemens, S) is its reciprocal: G = 1/R
Electric charge is measured in coulombs (C); the defining relationship is Q = It
CAAS Module 3 expects fluent SI unit use and clear separation of EMF, voltage drop, current, resistance, conductance, and charge
Last updated: July 2026
CAAS SAR-66 Module 3 topic 3.3 Electrical Terminology is the vocabulary layer for every later DC and AC calculation. If you confuse EMF with a voltage drop, or mix conventional current with electron flow, you will lose marks on otherwise simple questions. Treat this section as a working toolkit: define each quantity, name its SI unit, know what factors change it, and connect the two exam relationships G = 1/R and Q = It .
Potential Difference, EMF, and Voltage
Potential difference is the difference in electric potential between two points in a circuit. It is the “electrical pressure” available to move charge through a load. The SI unit is the volt (V) . One volt equals one joule of energy transferred per coulomb of charge (1 V = 1 J/C).
Electromotive force (EMF) is the potential difference produced by an energy source (battery, generator, thermocouple, and so on) when the source is open-circuit, or more precisely the work done per unit charge by the source as charge travels around a complete circuit. EMF is also measured in volts, but conceptually it is the source voltage, not a drop across a resistor.
Voltage in maintenance language often means either EMF or a measured potential difference. On the exam, read the stem carefully:
“EMF of the battery” → source voltage (ideally open-circuit).
“Voltage across the lamp” → potential difference (voltage drop) at that load.
“Supply voltage” → usually the source terminal voltage under the stated load.
Factors affecting potential difference / EMF
- Factor Effect in practice
- Source chemistry or magnetic design Sets the open-circuit EMF
- Internal resistance and load current Terminal voltage falls as I × r_internal increases
- Temperature Battery EMF and generator regulation shift with temperature
- Series/parallel source connection Series adds EMFs; parallel keeps EMF (if identical) but shares current
- Wiring resistance and poor joints Extra voltage drop between source and load
Worked idea: A 28 V aircraft bus with 0.05 Ω feeder resistance and 40 A load current drops V = IR = 40 × 0.05 = 2.0 V in the feeder. The load may see about 26 V even though the generator EMF is higher. Potential difference between two points is always local to those points.
Current
Current is the rate of flow of electric charge. The SI unit is the ampere (A) . One ampere equals one coulomb of charge passing a point every second (1 A = 1 C/s).
Current requires a closed path and a driving potential difference. In a simple series loop, the same current passes every series element. In parallel branches, currents divide according to branch resistances.
Factors affecting current
Applied voltage (higher V tends to raise I if R is fixed).
Circuit resistance (higher R lowers I for a given V — Ohm’s law territory in topic 3.6).
Number and arrangement of parallel paths.
Temperature (many conductors increase resistance as they heat, reducing current slightly for a fixed voltage).
Source ability to deliver current (capacity, state of charge, generator regulation).
Unit conversion drill: Convert 350 mA to amperes: 350 mA = 350 × 10⁻³ A = 0.35 A . Convert 2.5 A to milliamperes: 2.5 × 10³ = 2500 mA . Module 3 stems often bury milliamp or microamp values inside otherwise simple definitions.
Conventional Current Flow vs Electron Flow (Exam Trap)
This is a classic CAAS Module 3 trap.
Conventional current is defined as the direction that positive charge would move: from the positive terminal of the source, through the external circuit, to the negative terminal. Circuit diagrams, Kirchhoff’s laws as taught on the module, and most meter polarity conventions use conventional current.
Electron flow is the actual motion of free electrons in metallic conductors: from the negative terminal, through the external circuit, toward the positive terminal — opposite to conventional current.
- Model External-circuit direction Used for
- Conventional current + → − Standard circuit analysis, most exam diagrams
- Electron flow − → + Physical description of metallic conduction
If a question asks “direction of conventional current through the lamp,” answer from positive toward negative through the lamp. If it asks “direction of electron flow,” reverse it. Do not invent a third “both are the same” compromise — they are opposite by definition.
Resistance and Conductance
Resistance is opposition to current in a material or component. The SI unit is the ohm (Ω) . One ohm is the resistance that allows one ampere when one volt is applied (from the Ohm’s-law definition used later in the module).
Conductance is the ease with which a material allows current — the reciprocal of resistance:
G = 1/R
The SI unit of conductance is the siemens (S) . Older texts may say “mho,” but Module 3 expects siemens.
Worked conductance conversions
A heater has R = 10 Ω. Conductance G = 1/10 = 0.1 S .
A sensor has G = 5 mS = 0.005 S. Resistance R = 1/0.005 = 200 Ω .
Two equal 4 Ω resistors in parallel (preview of later topic): equivalent R = 2 Ω, so G_eq = 0.5 S — each branch contributes G = 0.25 S and conductances add in parallel.
Factors affecting resistance
- Factor Typical metallic conductor behaviour
- Length R increases with length
- Cross-sectional area R decreases as area increases
- Material (resistivity) Copper lower R than nichrome for same size
- Temperature Most metals: R rises as temperature rises
- Connections/corrosion Extra contact resistance raises total R
Aircraft maintenance links: undersized jumpers, corroded bonding straps, and high-resistance earth returns show up as heat, voltage drop, and nuisance trips — all resistance problems dressed as “power” complaints.
Charge
Electric charge is a property of matter; the SI unit is the coulomb (C) . The elementary charge on one electron is about 1.6 × 10⁻¹⁹ C, so one coulomb is an enormous number of electrons — useful as a bulk unit for circuit equations.
The fundamental relationship linking charge, current, and time is:
Q = It
where Q is charge in coulombs, I is current in amperes, and t is time in seconds.
Worked Q = It examples
A 2 A lamp runs for 30 minutes. t = 30 × 60 = 1800 s. Q = 2 × 1800 = 3600 C .
A capacitor (preview) stores Q = 0.02 C after charging at a constant 50 mA. Time t = Q/I = 0.02 / 0.05 = 0.4 s .
An avionics bus draws 800 mA for 45 s. Q = 0.8 × 45 = 36 C .
Rearrangements you must recognise instantly: I = Q/t and t = Q/I .
SI Unit Summary Table
- Quantity Symbol (typical) SI unit Unit symbol Key relationship
- Potential difference / voltage / EMF V, E volt V Energy per charge
- Current I ampere A I = Q/t
- Resistance R ohm Ω —
- Conductance G siemens S G = 1/R
- Charge Q coulomb C Q = It
- Exam Scenario Mindset
On a CAAS Module 3 paper you might see: “A component has a conductance of 2.5 S. What is its resistance?” Answer 0.4 Ω (R = 1/2.5). Or: “Conventional current in a metal wire flows…” → from positive to negative , even though electrons move the other way. Or: “Charge transferred by 5 A in 2 minutes” → t = 120 s, Q = 600 C.
Keep EMF (source) distinct from voltage drop (load or wiring), keep G as the reciprocal of R, and always convert time to seconds before using Q = It. Those three habits eliminate most terminology errors before you reach Ohm’s law, Kirchhoff, and power topics.