14.2 Losses, Efficiency, Load/No-Load & Turns Ratio
CAAS SAR-66 AML Module 3 — Electrical Fundamentals Exam
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
1.1 Current Exam Facts 1.2 Knowledge Levels & Study Approach for Module 3
2 Electron Theory & Static Electricity
2.1 Electron Theory & Atomic Structure 2.2 Conductors, Semiconductors & Insulators 2.3 Static Electricity, Coulomb's Law & Conduction
3 Terminology & Generation of Electricity
3.1 Electrical Terminology 3.2 Generation of Electricity
4 DC Sources of Electricity
4.1 Primary & Secondary Cells 4.2 Lead-Acid & Nickel-Cadmium Batteries 4.3 Series/Parallel Cells, Internal Resistance, Thermocouples & Photocells
5 DC Circuits
5.1 Ohm's Law 5.2 Kirchhoff's Voltage & Current Laws 5.3 Series/Parallel Networks & Supply Internal Resistance
6 Resistance & Resistors
6.1 Resistivity & Factors Affecting Resistance 6.2 Resistor Colour Code, Tolerance & Preferred Values 6.3 Series/Parallel Resistors, Potentiometers & Rheostats 6.4 Wheatstone Bridge, Thermistors & Temperature Coefficient
7 Power, Work & Energy
7.1 Power, Work & Energy Concepts 7.2 Power Dissipation & Calculations
8 Capacitance & Capacitors
8.1 Capacitor Operation & Factors Affecting Capacitance 8.2 Series/Parallel Capacitors & Types 8.3 RC Time Constants, Energy Storage & Testing
9 Magnetism
9.1 Theory of Magnetism & Magnetic Materials 9.2 Electromagnets & Hand Rules 9.3 MMF, Flux Density, Permeability, Hysteresis & Eddy Currents
10 Inductance & Inductors
10.1 Faraday's Law & Induced Voltage 10.2 Self & Mutual Inductance, Lenz's Law 10.3 Back EMF, Saturation & Inductor Applications
11 DC Motor/Generator Theory
11.1 Basic Motor & Generator Theory 11.2 DC Generators — Construction & Operation 11.3 DC Motors — Series, Shunt, Compound & Starter-Generators
12 AC Theory
12.1 Sinusoidal Waveforms — Phase, Period, Frequency 12.2 Peak, Average, RMS Values & Calculations 12.3 Non-Sinusoidal Waves & Single/Three-Phase Principles
13 R, L & C Circuits
13.1 Phase Relationships in R, L, C Circuits 13.2 Impedance, Phase Angle & Power Factor 13.3 True, Apparent & Reactive Power
14 Transformers
14.1 Transformer Construction & Operation 14.2 Losses, Efficiency, Load/No-Load & Turns Ratio 14.3 Three-Phase Transformers & Autotransformers
15 Filters & AC Generators
15.1 Filters — Low Pass, High Pass, Band Pass, Band Stop 15.2 AC Generator Principles & Construction 15.3 Star/Delta Connections & Permanent Magnet Generators
16 AC Motors
16.1 Synchronous & Induction Motors 16.2 Speed Control, Direction & Rotating Field Methods
14.2 Losses, Efficiency, Load/No-Load & Turns Ratio
Key Takeaways Explain This Topic AI
Ideal turns-ratio law: Vp/Vs = Np/Ns = Is/Ip; for ideal power, Vp × Ip = Vs × Is
Copper (I²R) losses occur in windings and rise with load current; iron/core losses are hysteresis plus eddy currents and are essentially present whenever the core is energised
Eddy currents are reduced by laminated cores and higher-resistivity silicon steel; hysteresis is reduced by magnetically soft core material (narrow loop)
No-load primary current is mainly magnetising plus a small core-loss component; load current rises when the secondary delivers power
- Efficiency η = Pout / Pin × 100% = Pout / (Pout + losses) × 100%
- Last updated: July 2026
14.2 Losses, Efficiency, Load/No-Load & Turns Ratio
Quick Answer: Vp/Vs = Np/Ns = Is/Ip . Ideal power: Vp Ip = Vs Is . Copper losses = I²R in windings (load-dependent). Iron losses = hysteresis + eddy in the core (present when energised). η = Pout/(Pout+losses) .
Section 14.1 built the physical picture. Syllabus 3.15 expects fluent turns-ratio arithmetic , clear separation of copper vs iron losses , and the difference between no-load and loaded operation — all staples of CAAS Module 3 MCQs.
Turns Ratio — Voltage, Current, Power
Define:
- Symbol Meaning
- Vp, Vs Primary / secondary RMS voltages
- Ip, Is Primary / secondary RMS currents
- Np, Ns Primary / secondary turns
- a = Np/Ns Turns ratio (primary to secondary)
Ideal transformer:
Vp / Vs = Np / Ns = Is / Ip
Equivalently:
Vs = Vp × (Ns / Np) and Ip = Is × (Ns / Np) or Is = Ip × (Np / Ns)
Voltage ratio equals turns ratio; current ratio is the inverse . Step-down voltage → step-up current (and vice versa) so that, ideally:
Pin = Pout → Vp × Ip = Vs × Is
(assuming unity power factor on both sides for the basic Module 3 model).
Worked example 1 — step-down voltage
Aircraft bus Vp = 115 V , turns Np : Ns = 5 : 1 .
Vs = 115 × (1/5) = 23 V .
Worked example 2 — primary current from secondary load
Same transformer; secondary load draws Is = 10 A (ideal).
Ip = Is × (Ns/Np) = 10 × (1/5) = 2 A .
Check power: Pin = 115 × 2 = 230 W; Pout = 23 × 10 = 230 W.
Worked example 3 — find turns
Instrument transformer: Vp = 115 V, Vs = 28 V, Np = 960 turns. Find Ns.
Ns = Np × (Vs/Vp) = 960 × (28/115) ≈ 233.7 → 234 turns (nearest whole turn).
Worked example 4 — step-up
Np = 200, Ns = 800, Vp = 28 V.
Vs = 28 × (800/200) = 112 V . If Is = 0.5 A, Ip = 0.5 × (800/200) = 2 A .
Impedance reflection (recognition-level)
Load Zs on the secondary appears at the primary approximately as:
Zp ≈ Zs × (Np/Ns)²
Module 3 may only require recognising that impedance scales with the square of the turns ratio — useful in coupling/matching discussions.
- Load vs No-Load
- No-load (secondary open)
Secondary current Is ≈ 0 (no load power).
Primary draws no-load current I0 : magnetising component (creates flux) + small core-loss component.
I0 is typically a few percent of full-load primary current on efficient units.
Core flux is set mainly by applied Vp and frequency (V/f roughly related to flux).
Iron losses continue whenever the primary is energised at rated voltage/frequency.
Copper losses in the secondary are zero; primary copper loss is small (I0² Rp).
On load
Secondary delivers Is to the load.
Secondary ampere-turns are opposed by additional primary ampere-turns → Ip rises .
Ideal relation Ip ≈ Is × (Ns/Np) plus the smaller magnetising component.
Copper losses in both windings increase roughly with the square of current.
Terminal voltage Vs may droop slightly on a real transformer because of winding resistance and leakage reactance (voltage regulation) — ideal maths ignore this unless the stem gives regulation data.
- Condition Is Ip (approx.) Dominant notes
- No-load ≈ 0 I0 (small) Iron loss present; little copper loss
- Loaded Load value ≈ Is × Ns/Np (+ I0) Copper loss rises; iron loss still present
- Transformer Losses
Real efficiency is less than 100%. Loss categories Module 3 emphasises:
1. Copper losses (winding / I²R losses)
Pcu = Ip² Rp + Is² Rs (or treated as a combined full-load copper-loss figure).
Cause: resistance of copper (or aluminium) windings. Mitigation: larger conductor cross-section, high-conductivity copper, shorter mean turn length. High-current (usually LV) windings need thicker wire.
Copper loss is load-dependent — approximately proportional to load current squared.
2. Iron / core losses
Present whenever the core is magnetised by rated AC voltage (approximately constant with load in the basic model if V and f stay fixed).
(a) Hysteresis loss — energy spent reorienting magnetic domains each cycle; area of the B–H loop each second. Worse at higher frequency and with “harder” magnetic materials. Mitigation: soft silicon steel with a narrow hysteresis loop (low coercivity).
(b) Eddy-current loss — circulating currents induced in the conducting core by alternating flux; heat as I²R inside the iron. Mitigation: thin insulated laminations parallel to flux; silicon to raise core resistivity. Solid cores are unacceptable for AC power transformers.
3. Flux leakage (coupling imperfection)
Some primary flux fails to link the secondary (and vice versa). Effects: leakage inductance, voltage drop under load, slightly less than ideal coupling. Mitigation: shell-type cores, interleaved/concentric windings, short leakage paths.
Overcoming / reducing losses — exam table
- Loss Overcome / reduced by
- Copper Thicker / better conductors; good cooling
- Eddy Laminations + silicon steel resistivity
- Hysteresis Soft magnetic core material, narrow loop
- Leakage Shell-type / interleaved winding layout
- Efficiency
- η = (Pout / Pin) × 100%
- Pin = Pout + Pcu + Piron (+ other small losses)
So:
η = Pout / (Pout + losses) × 100%
Aircraft transformers often exceed ~95% at sensible loads; Module 3 still expects you to compute from given loss watts.
Worked example 5 — efficiency
Rated output 2500 W (unity pf). Copper loss 45 W , iron loss 35 W .
Total losses = 80 W.
Pin = 2500 + 80 = 2580 W .
η = 2500/2580 × 100% ≈ 96.9% .
Worked example 6 — find Pout from η
Pin = 1200 W, η = 96%.
Pout = 0.96 × 1200 = 1152 W . Losses = 48 W.
Worked example 7 — ideal current then add losses (concept)
Ideal Vp=115 V, Vs=23 V, Is=10 A → Ip=2 A, Pout=230 W. If total losses at that load are 10 W, Pin=240 W, η=230/240≈ 95.8% . Do not use ideal Ip alone when a stem already gives Pin or losses.
Power Transfer Recap
Ideal: energy conserved magnetically — voltage up, current down (or reverse).
Real: a few percent becomes heat (copper + iron).
kVA rating is based on voltage × current capability (heating/insulation), not on a guaranteed wattage at any power factor.
Common Traps
Using Vp/Vs = Ip/Is (forgetting current is inverse).
Calling laminations a fix for hysteresis (they primarily cut eddy paths; soft steel fixes hysteresis).
Saying iron loss is zero at no-load (opposite: iron loss continues; copper is minimal).
Mixing peak and RMS in turns-ratio arithmetic — use consistent RMS nameplate values.
Drill Vp/Vs = Np/Ns = Is/Ip and the copper/iron mitigation table until both are automatic. Section 14.3 extends the same ideas to three-phase banks and autotransformers.