Study guide
5.3 CPR Protocols & Automated External Defibrillator (AED)
STCW Basic Safety Training Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: STCW Regulatory Framework & Emergency Preparedness
1.1 STCW Regulatory Framework & 2026 Standards 1.2 Shipboard Alarms, Muster Lists & Emergency Stations 1.3 Personal Life-Saving Appliances (LSA) 1.4 Contingency Plans, Escape Routes & Internal Communications 1.5 Discovering an Emergency: Raising the Alarm, Flooding & Damage Control
2 Chapter 2: Personal Survival Techniques & Abandon Ship
2.1 Abandon Ship Procedures & Safe Water Entry 2.2 Cold Water Survival, HELP & Group Tactics 2.3 Inflatable Liferafts, Lifeboats & Launching Appliances 2.4 Survival Craft Equipment, Pyrotechnics & Rescue Operations 2.5 Lifebuoys, Man-Overboard Equipment & Recovery of Persons from the Water 2.6 Survival Swimming, Staying Afloat & In-Water Skills 2.7 Survival Craft Radio Equipment & GMDSS Distress Alerting 2.8 Main Dangers to Survivors & Long-Term Survival Discipline
3 Chapter 3: Fire Chemistry, Hazards & Detection Systems
3.1 Fire Chemistry, The Tetrahedron & Fire Classes 3.2 Shipboard Fire Hazards & Prevention Practices 3.3 Fire Detection, Alarm Systems & Boundary Controls 3.4 Shipboard Fire Organization, Fire Parties & Fire Drills 3.5 Combustion Products, Smoke and Toxic Gas Hazards
4 Chapter 4: Firefighting Equipment, SCBA & Suppression Tactics
4.1 Portable & Semi-Portable Fire Extinguishers 4.2 Fixed Fire-Extinguishing Systems 4.3 Firefighter PPE & Self-Contained Breathing Apparatus (SCBA) 4.4 Firefighting Team Tactics, Hose Handling & Search Operations 4.5 Applying Extinguishing Agents to Oil, Electrical, Gas and Enclosed-Space Fires 4.6 Breathing Apparatus Emergencies, Firefighter Rescue & Post-Fire Decontamination
5 Chapter 5: Elementary First Aid & Life-Saving Interventions
5.1 Body Structure and Function: Anatomy for Shipboard First Aid 5.2 Scene Safety, Primary Survey & Triage 5.3 CPR Protocols & Automated External Defibrillator (AED) 5.4 Severe Bleeding, Shock Management & Wound Care 5.5 Burns, Fractures, Environmental Injuries & Casualty Movement 5.6 Common Shipboard Medical Emergencies & Poisoning 5.7 Bandaging, Dressings, Improvisation & the Ship's Medical Stores
6 Chapter 6: Personal Safety, Social Responsibilities & 2026 Standards
6.1 Shipboard Safety Management, Permits & Enclosed Space Entry 6.2 Occupational Health, Risk Assessment & PPE 6.3 Marine Environmental Protection & MARPOL Regulations 6.4 Effective Communication on Board: Principles, Barriers & SMCP 6.5 Teamwork, Conflict Resolution, Social Responsibilities & Seafarers' Rights 6.6 Fatigue Management: Rest Hours, Sleep Science & Substance Abuse 6.7 Violence and Harassment: Prevention, Recognition and Response (2026 Standards)
5.3 CPR Protocols & Automated External Defibrillator (AED)
Key Takeaways Explain This Topic AI
Cardiac arrest recognition requires rapid verification of unresponsiveness, absent or abnormal breathing (agonal gasps), and absent carotid pulse within 10 seconds.
High-quality adult CPR mandates a 30:2 compression-to-ventilation ratio at a rate of 100–120 compressions per minute and depth of 5–6 cm (2–2.4 inches), ensuring complete chest recoil.
High chest compression fraction (CCF > 80%) with interruptions strictly limited to under 10 seconds is vital to maintaining coronary and cerebral perfusion pressures.
AED pads must be applied in the antero-lateral position (upper right chest below clavicle and lower left chest mid-axillary line), with CPR resumed immediately for 2 minutes post-shock without pausing for a pulse check.
Compressor fatigue degrades compression depth within 2 minutes; rescuers must swap compressor roles every 2 minutes (approx. 5 cycles of 30:2) during AED analysis with minimal interruption (<5 seconds).
Last updated: August 2026
5.3 CPR Protocols & Automated External Defibrillator (AED)
Core Principle: Cardiopulmonary resuscitation (CPR) manually preserves artificial forward blood flow to the brain and myocardium until an Automated External Defibrillator (AED) or advanced medical care can terminate lethal dysrhythmias. Every second of delay or interruption in chest compressions precipitously drops coronary perfusion pressure and survival probability.
1. Cardiac Arrest Recognition & Physiology
Cardiac arrest is the abrupt cessation of mechanical cardiac pump function, causing immediate loss of arterial blood pressure and systemic tissue perfusion. Without oxygenated blood flow, cerebral electrical activity ceases within 10 seconds, and irreversible neuronal death begins within 4 to 6 minutes. CARDIAC ARREST RECOGNITION TRIAD
- 1. UNRESPONSIVENESS ──► No response to voice or painful stimulation
- 2. ABSENT / AGONAL ──► No chest rise, or isolated, gasping, snorting
- BREATHING efforts (agonal respirations)
- 3. ABSENT CAROTID PULSE ──► No definite carotid pulse felt within 10 SECONDS
- (Simultaneous pulse and breathing check)
- Agonal Gasps vs. Normal Respiration
Agonal gasps are reflexive, irregular, labored snorting or gasping sounds originating from the dying brainstem. They occur in up to 40% of cardiac arrests in the first several minutes.
Exam Warning: Agonal gasps are NOT normal breathing. Responders must recognize agonal gasps as a sign of cardiac arrest and initiate immediate high-quality CPR without delay.
Carotid Pulse Palpation Guidelines
Locate the casualty's thyroid cartilage (Adam's apple) using the index and middle fingers.
Slide fingers laterally into the groove between the trachea and sternocleidomastoid muscle.
Palpate for at least 5 but no more than 10 seconds .
If you do not feel a definite pulse within 10 seconds, presume cardiac arrest and immediately begin chest compressions .
2. High-Quality Adult CPR Parameters
High-quality CPR is the single greatest determinant of survival from sudden cardiac arrest. International resuscitation bodies (ILCOR, AHA, ERC) establish precise metrics that every certified mariner must execute. HIGH-QUALITY ADULT CPR METRICS
- COMPRESSION RATIO COMPRESSION RATE COMPRESSION DEPTH CHEST RECOIL
- 30 : 2 100 – 120 5 – 6 cm 100% COMPLETE
- [30 Compressions to [Compressions [2.0 – 2.4 Inches] [No Leaning on
- 2 Rescue Breaths] Per Minute] Chest Wall]
- Detailed CPR Parameters Breakdown
Parameter Standard Benchmark Physiological Justification Common Execution Errors
Hand Placement Heel of one hand on lower half of sternum (center of chest); second hand interlaced on top. Direct compression of the left and right ventricles between the sternum and thoracic spine. Placing hands too low (xiphoid process / liver laceration) or too lateral (rib fractures).
Rescuer Body Mechanics Shoulders directly above hands; elbows locked straight; compress from hip hinge. Uses upper body weight to generate force, conserving arm muscle energy. Bending elbows; using arm muscles; rapid physical exhaustion.
Compression Rate 100 to 120 compressions per minute (Rhythm of "Stayin' Alive" ). Maximizes cardiac output; rates <100 produce inadequate flow; rates >120 prevent ventricular filling. Compressing too slowly (<90 bpm) or rushing frantically (>130 bpm).
Compression Depth 5 to 6 cm (2.0 to 2.4 inches) in adults. Generates sufficient intra-ventricular pressure to open aortic valve and perfuse coronary arteries. Compressing too shallowly (<4 cm) or excessively deep (>6 cm with structural injury).
Chest Recoil Complete chest recoil after each compression; zero residual leaning. Full diastolic chest expansion creates negative intrathoracic pressure, refilling the heart with blood. Leaning on chest between compressions, severely reducing coronary perfusion pressure.
Chest Compression Fraction (CCF) CCF > 80% (Minimize all pauses to <10 seconds). Maintains continuous coronary perfusion pressure; coronary blood flow drops to zero during pauses. Prolonged pauses for pulse checks, pad attachment, or ventilation attempts.
3. Rescue Breaths & Ventilation Mechanics
Rescue ventilations deliver oxygen to the lungs to maintain alveolar gas exchange during CPR. Rescuers should utilize barrier devices to prevent pathogen transmission. VENTILATION TECHNIQUES
- POCKET MASK WITH ONE-WAY VALVE BAG-VALVE-MASK (BVM)
- [Single Rescuer] [Two Rescuers]
- ▲ ▲
- │ │
- Position at casualty's head • Rescuer 1: Holds E-C clamp with
- Form "C-E" clamp with thumb/index both hands, lifts jaw
- Tilt head back, lift chin • Rescuer 2: Squeezes bag over 1 sec
- Deliver 1-second breath • Delivers ~500–600 mL tidal volume
- Guidelines for Effective Ventilation
Duration: Deliver each rescue breath over exactly 1 second .
Volume: Deliver sufficient volume to produce a visible gentle chest rise (approximately 500 to 600 mL tidal volume in adults).
Compression-to-Ventilation Ratio: Deliver 2 rescue breaths after every 30 compressions (30:2). The pause between the 30th compression and resumption of compressions must not exceed 10 seconds .
The Dangers of Hyperventilation (Over-Ventilation)
Increased Intrathoracic Pressure: Excessive ventilation volume or rate elevates pressure within the pleural space, compressing the superior and inferior vena cava. This dramatically restricts venous return to the heart, causing a catastrophic drop in cardiac output generated by compressions.
Gastric Insufflation: Forcing excessive air into the pharynx forces the lower esophageal sphincter open, distending the stomach. This triggers regurgitation of gastric contents into the pharynx, leading to massive pulmonary aspiration and chemical pneumonitis.
4. Automated External Defibrillator (AED) Integration
An Automated External Defibrillator (AED) is a sophisticated computerized medical device that analyzes the casualty's cardiac rhythm and, if indicated, delivers a controlled electrical shock to terminate fatal dysrhythmias. CARDIAC ARREST RHYTHM TYPES
- SHOCKABLE RHYTHMS (AED Advises Shock) NON-SHOCKABLE RHYTHMS (No Shock)
- Ventricular Fibrillation (VF) • Asystole ("Flatline")
- (Disorganized, chaotic twitching) (Total absence of electrical activity)
- Pulseless Ventricular Tachycardia (pVT) • Pulseless Electrical Activity (PEA)
- (Rapid, non-perfusing wide complexes) (Organized electrical rhythm, no pulse)
- Mechanism of Defibrillation
Defibrillation does not "jumpstart" a dead heart. Instead, the high-voltage electrical shock simultaneously depolarizes the entire myocardium, terminating the chaotic electrical storm of VF/pVT. This momentary cellular silence allows the heart's natural pacemaker—the Sinoatrial (SA) Node—to resume an organized, perfusing sinus rhythm.
The Universal 4-Step AED Operating Protocol UNIVERSAL AED SEQUENCE
- [STEP 1: POWER ON] ──► Open lid or press Power button immediately
- │
- [STEP 2: ATTACH PADS] ──► Bare & dry chest; apply self-adhesive pads
- │
- [STEP 3: ANALYZE RHYTHM] ──► Clear casualty ("STAND CLEAR!"); do not touch
- │
- [STEP 4: SHOCK / RESUME] ──► If shock advised: Clear & press Shock button
- ──► IMMEDIATELY RESUME CPR (30:2) starting
- with chest compressions
- Detailed AED Application Steps
Power On Immediately: Turn on the AED as soon as it arrives at the scene. Listen to and follow all automated voice prompts.
Expose and Prepare Chest:
Strip all clothing from the casualty's upper torso.
Dry the skin: If the casualty is wet, sweaty, or pulled from the sea, wipe the chest dry with a towel.
Excessive chest hair: Press pads firmly; if the AED prompts "Check Pads," rip off pads to remove hair, or quickly shave pad application sites with the razor in the AED kit.
Implanted Pacemakers / ICDs: If a hard, disc-like lump with surgical scar is visible under the skin (usually upper left chest), place the AED pad at least 2.5 cm (1 inch) away from the device.
Transdermal Medication Patches: Remove any nitro or nicotine patches with gloved hands and wipe residue before placing pads.
Pad Placement (Antero-Lateral Configuration):
Pad 1 (Upper Right): Right anterior chest, directly below the clavicle (collarbone), to the right of the sternum.
Pad 2 (Lower Left): Left lower chest, mid-axillary line, 5th–6th intercostal space, several centimeters below the left axilla (armpit).
Rhythm Analysis & Shock Delivery:
When the AED states "Analyzing heart rhythm, do not touch the patient," the rescuer must command loudly: "STAND CLEAR!" Ensure no one is touching the casualty, stretcher, or connected lines.
If a shock is advised: Visual scan from head to toe ( "I'm clear, you're clear, everyone's clear!" ), then press the flashing Shock button (or stand back if fully automated).
Immediate Post-Shock Protocol:
IMMEDIATELY resume CPR (30:2) starting with chest compressions right after the shock is delivered.
DO NOT stop to check for a carotid pulse or breathing.
Continue CPR for 2 minutes (approximately 5 cycles of 30:2) until the AED prompts for the next rhythm analysis.
5. Two-Rescuer Team Dynamics & Compressor Rotation
Rescuer fatigue develops rapidly during CPR. Research proves that compression depth declines significantly after just 1 to 2 minutes of continuous compressions, even when the rescuer denies feeling tired. TWO-RESCUER CPR SYNCHRONIZATION
- RESCUER 1 (Compressor) RESCUER 2 (Airway & AED)
- Performs 30 chest compressions • Manages airway & pocket mask / BVM
- Counts compressions aloud • Delivers 2 rescue breaths
- Maintains high rate (100-120/min) • Operates AED
- Monitors compression quality & depth
- 🔄 ROTATE ROLES EVERY 2 MINUTES (5 CYCLES OF 30:2)
- Transition during AED analysis in LESS THAN 5 SECONDS
- Seamless Role Switching Protocol
Timing: Switch compressor roles every 2 minutes (approx. 5 cycles of 30:2) , ideally timed with the AED rhythm analysis.
Execution: Rescuer 2 moves into position at the chest while Rescuer 1 takes over the airway/BVM. The entire transition must take less than 5 seconds to prevent drop in coronary perfusion.
6. Special Shipboard Resuscitation Environments
Wet Decks & Metal Surfaces: AEDs are completely safe to use on steel ship decks. If the casualty is lying in standing water (bilges, flooded deck), drag them to a dry area and towel-dry the chest before attaching pads. Rescuers should avoid standing directly in puddles connecting them to the casualty.
Vessel Motion in Heavy Seas: In rolling seas, rescuers should adopt a wide kneeling stance with knees spread wide, stabilizing themselves against bulkheads or using deck tie-downs while maintaining continuous compressions.
Hypothermic Cardiac Arrest: In cold-water immersion cases ( "not dead until warm and dead" ), the cold myocardium resists both defibrillation and drugs. Current European Resuscitation Council guidance is specific: if VF/pVT is present, deliver up to 3 shocks ; if VF persists, withhold further defibrillation attempts until the core temperature is above 30°C (86°F) . Adrenaline is withheld entirely below 30°C and given at 6–10 minute intervals above it. Compression and ventilation rates are unchanged from normothermic CPR. Continue uninterrupted high-quality CPR with active rewarming and, where reachable, transfer toward extracorporeal rewarming.