Study guide
1.4 Contingency Plans, Escape Routes & Internal Communications
STCW Basic Safety Training Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: STCW Regulatory Framework & Emergency Preparedness
1.1 STCW Regulatory Framework & 2026 Standards 1.2 Shipboard Alarms, Muster Lists & Emergency Stations 1.3 Personal Life-Saving Appliances (LSA) 1.4 Contingency Plans, Escape Routes & Internal Communications 1.5 Discovering an Emergency: Raising the Alarm, Flooding & Damage Control
2 Chapter 2: Personal Survival Techniques & Abandon Ship
2.1 Abandon Ship Procedures & Safe Water Entry 2.2 Cold Water Survival, HELP & Group Tactics 2.3 Inflatable Liferafts, Lifeboats & Launching Appliances 2.4 Survival Craft Equipment, Pyrotechnics & Rescue Operations 2.5 Lifebuoys, Man-Overboard Equipment & Recovery of Persons from the Water 2.6 Survival Swimming, Staying Afloat & In-Water Skills 2.7 Survival Craft Radio Equipment & GMDSS Distress Alerting 2.8 Main Dangers to Survivors & Long-Term Survival Discipline
3 Chapter 3: Fire Chemistry, Hazards & Detection Systems
3.1 Fire Chemistry, The Tetrahedron & Fire Classes 3.2 Shipboard Fire Hazards & Prevention Practices 3.3 Fire Detection, Alarm Systems & Boundary Controls 3.4 Shipboard Fire Organization, Fire Parties & Fire Drills 3.5 Combustion Products, Smoke and Toxic Gas Hazards
4 Chapter 4: Firefighting Equipment, SCBA & Suppression Tactics
4.1 Portable & Semi-Portable Fire Extinguishers 4.2 Fixed Fire-Extinguishing Systems 4.3 Firefighter PPE & Self-Contained Breathing Apparatus (SCBA) 4.4 Firefighting Team Tactics, Hose Handling & Search Operations 4.5 Applying Extinguishing Agents to Oil, Electrical, Gas and Enclosed-Space Fires 4.6 Breathing Apparatus Emergencies, Firefighter Rescue & Post-Fire Decontamination
5 Chapter 5: Elementary First Aid & Life-Saving Interventions
5.1 Body Structure and Function: Anatomy for Shipboard First Aid 5.2 Scene Safety, Primary Survey & Triage 5.3 CPR Protocols & Automated External Defibrillator (AED) 5.4 Severe Bleeding, Shock Management & Wound Care 5.5 Burns, Fractures, Environmental Injuries & Casualty Movement 5.6 Common Shipboard Medical Emergencies & Poisoning 5.7 Bandaging, Dressings, Improvisation & the Ship's Medical Stores
6 Chapter 6: Personal Safety, Social Responsibilities & 2026 Standards
6.1 Shipboard Safety Management, Permits & Enclosed Space Entry 6.2 Occupational Health, Risk Assessment & PPE 6.3 Marine Environmental Protection & MARPOL Regulations 6.4 Effective Communication on Board: Principles, Barriers & SMCP 6.5 Teamwork, Conflict Resolution, Social Responsibilities & Seafarers' Rights 6.6 Fatigue Management: Rest Hours, Sleep Science & Substance Abuse 6.7 Violence and Harassment: Prevention, Recognition and Response (2026 Standards)
1.4 Contingency Plans, Escape Routes & Internal Communications
Key Takeaways Explain This Topic AI
SOLAS Chapter II-2 Regulation 13 requires at least two widely separated means of escape from every normally occupied space, and prohibits dead-end corridors longer than 7 metres in accommodation areas.
A ship carries a family of statutory contingency plans — the ISM emergency response procedures, the damage control plan (SOLAS II-1/19), the fire control plan (SOLAS II-2/15.2.4), SOPEP (MARPOL Annex I Reg 37) and the Ship Security Plan — each with a defined location and a defined trigger.
Emergency Escape Breathing Devices provide at least 10 minutes of breathable air and are for ESCAPE ONLY; the FSS Code forbids their use for firefighting, for entering oxygen-deficient tanks, or by a member of a fire team.
The general emergency alarm must be audible throughout all accommodation, normal crew working spaces and open decks, and is supplemented by a public address system that can override cabin volume controls.
Escape routes are marked with photoluminescent or electrically powered low-location lighting so that the markings remain readable when a smoke layer has dropped below eye level and the main lighting has failed.
Last updated: August 2026
1.4 Contingency Plans, Escape Routes & Internal Communications
Core Principle: An emergency is not the moment to discover where the second exit is, which plan covers a bunker spill, or how to raise the bridge from a machinery flat. Table A-VI/1-4 requires every seafarer to have working knowledge of the ship's contingency plans, its escape routes, and its internal communication and alarm systems — before an alarm ever sounds.
1. The Family of Shipboard Contingency Plans
A modern commercial ship carries a stack of statutory plans. Each has a different owner, a different trigger, and a defined stowage location. Basic Training expects you to be able to name the plan, say what triggers it, and say where it lives.
Plan Statutory Source Trigger Where It Is Kept
Emergency response procedures ISM Code section 8 Any identified shipboard emergency scenario Safety Management System manual; bridge and ECR
Muster list / station bill SOLAS III/8 and III/37 General emergency alarm Bridge, ECR, messrooms, alleyways, cabins
Fire control plan SOLAS II-2/15.2.4 Fire; shore brigade attendance Exhibited internally, plus a duplicate set in a prominently marked weathertight enclosure outside the deckhouse
Damage control plan and booklet SOLAS II-1/19 Flooding, collision, grounding Bridge; officers' hands
SOPEP (Shipboard Oil Pollution Emergency Plan) MARPOL Annex I, Reg 37 Oil spill or probable discharge Bridge / ship's office
SMPEP (for noxious liquid substances) MARPOL Annex II, Reg 17 NLS spill on a chemical tanker Cargo control room
Ship Security Plan (SSP) ISPS Code Part A Security level change, security incident Restricted; SSO holds it
Garbage Management Plan MARPOL Annex V, Reg 10 Routine and abnormal waste handling Messroom notice + ship's office
Enclosed space entry and rescue procedures SOLAS III/19 and IMO Res A.1050(27) Any enclosed space entry SMS; permit book
Exam Watchout: The fire control plan question almost always tests the duplicate outside the deckhouse . SOLAS requires a second set to be permanently stored in a prominently marked weathertight enclosure outside the deckhouse for the assistance of shore-side firefighting personnel. A shore brigade arriving alongside must be able to read the ship's fire zones without entering the accommodation.
What the Fire Control Plan Shows
Fire control plans are drawn using the standard graphical symbols of IMO Resolution A.952(23) . A general-arrangement plan for each deck shows:
The control stations, and the boundaries of A-class and B-class divisions.
Fire-detection and fire-alarm zones and sprinkler installations.
Extinguishing appliances — hydrants, portable and semi-portable extinguishers, fixed installations, foam and powder applicators.
Means of access to compartments, decks and escape trunks.
The ventilation system, including fan-control positions, damper positions and the identification numbers of the ventilating fans serving each section.
2. Means of Escape (SOLAS Chapter II-2, Regulation 13)
Escape provisions exist so that a person can get out of a space when the normal route is on fire.
The Governing Rules
Two ways out. Stairways and ladders must be arranged to provide ready means of escape to the lifeboat and liferaft embarkation deck from all crew and passenger spaces. In general, at least two widely separated means of escape are required from every normally occupied space.
No long dead ends. In accommodation areas, dead-end corridors more than 7 metres in length are not permitted — a corridor that traps a person with only one direction of travel is a design fault, not an inconvenience.
Escape from machinery spaces. Category A machinery spaces require two means of escape: normally a steel ladder to a door in the upper part, plus a protected escape trunk with self-closing fire doors that discharges to an open deck.
No locks. Doors on escape routes must be openable from the escape side without a key. Cabin doors must not be fitted with locks that need a key from inside.
Markings and low-location lighting. Escape routes are marked with a directional arrow-and-running-man symbol. On passenger ships, low-location lighting (LLL) — photoluminescent strips or electrically powered systems, guided by IMO Resolution A.752(18) — is fitted along the deck edge so that markings remain visible when smoke has banked down below eye level. WHY LOW-LOCATION LIGHTING EXISTS
- Overhead lights + high signage Deck-level LLL strip
- --------------------------------- ----------------------------------
- Smoke layer descends from the Marking stays in the clear air
- deckhead downward. Within 60-90 s layer at deck level, exactly where
an overhead EXIT sign is invisible. a crawling crew member is looking.
Escape Route Discipline
Walk your primary and secondary escape routes on familiarisation day, in the dark, counting doors and turns by hand.
Never stow gear, dunnage, drums or cleaning trolleys in an alleyway or on a stair landing.
Never chock, wedge or tie back a self-closing fire door.
Never use a lift during an alarm: a blackout traps the occupants and the trunk behaves as a chimney.
3. Emergency Escape Breathing Devices (EEBD)
An EEBD is a hooded, short-duration air supply carried so that a person can walk out of a smoke-filled space.
Duration: the FSS Code requires a service duration of at least 10 minutes .
Construction: a hood that covers the whole head, or a full-face mask, giving eye and airway protection; supplied from a small compressed-air cylinder or an oxygen-generating canister.
Locations: at least two in accommodation spaces, and units positioned ready for use at easily visible places in machinery spaces, reachable within seconds from the working positions.
Hard limits — the point most often tested. An EEBD is for escape only . It must not be used for fighting fires, for entering oxygen-deficient voids or tanks, or worn by a fire-team member in place of breathing apparatus. Training units are separately marked and must never be stowed with the service units.
4. Internal Communication and Alarm Systems
System What It Does Key Requirement
General emergency alarm Seven or more short blasts + one prolonged blast Audible throughout all accommodation, normal crew working spaces and open decks
Public address (PA) system Voice broadcast of orders and information Must be able to override cabin volume controls so an order reaches a sleeping crew member
Ship's whistle / klaxon External and open-deck signalling Backs up the electrical alarm and reaches personnel on deck
Sound-powered telephones Bridge–ECR–steering gear–fo'c'sle Works with the ship blacked out; no external power needed
Portable UHF/VHF radios Team-to-team traffic during an incident Intrinsically safe sets required in hazardous zones
Engineers' alarm Calls engineers from the ECR/cabins Operable from the engine control room and the manoeuvring platform
Fire detection panel Addressable zone/room identification Repeated on the bridge and at the fire control station
Communication Discipline in an Emergency
Emergency traffic is short, structured and confirmed. Use the closed loop : the sender states the message, the receiver reads it back, the sender confirms. State who you are, where you are, and what you have before you state what you want.
"Bridge, Bridge — Second Engineer at the purifier flat. Fuel oil fire at number two purifier, roughly one metre square, no casualties. I am closing the quick-closing valve and evacuating. Over."
That one transmission gives the Master a location, a size, a casualty count, an action already taken and an intention — everything needed to commit the fire party.