1.4 Activities Not Regulated: The § 6002.155 Exemptions
Texas Fire Alarm Installer License Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Texas Insurance Code Chapter 6002 Foundations
1.1 Chapter 6002 Purpose, Scope & Statutory Definitions 1.2 State Preemption and the Limits of Local Regulation 1.3 Commissioner and SFMO Authority; Adopted Standards and Editions 1.4 Activities Not Regulated: The § 6002.155 Exemptions 1.5 Required Device Labels, Listings and Consumer Information
2 Chapter 2: Certificates of Registration and Company Operating Rules
2.1 Registration Certificates: Main Office, Branch Office and Single Station 2.2 Insurance Requirements for Registered Firms 2.3 Business Location, Designated Employee and Vehicle Identification (§ 34.610) 2.4 Ownership Changes, Officer Changes and Revised Certificates
3 Chapter 3: Individual Licenses, Qualifying Tests and Renewal
3.1 The Six Texas Fire Alarm Licenses and What Each May Do 3.2 License Applications, Fingerprinting and Criminal History 3.3 The Qualifying Tests: TFM11, TFM12, TFM13, TFM14 and Their References 3.4 NICET, ESA and Professional Engineer Substitutions 3.5 Fees, the Two-Year Renewal Cycle and Late Renewal 3.6 Training Schools, Instructors and the Residential Technician Course
4 Chapter 4: Texas Field Practice — Installation, Service, Monitoring and Certification
4.1 Sales, Installation and Service Rules (§ 34.616) 4.2 Monitoring Requirements for Registered Firms (§ 34.616(c)) 4.3 The Installation Certificate (SF035) and Its Distribution 4.4 The Three-Stage Installation Inspection (§ 34.618) 4.5 Fire Alarm Plans and Record Drawings (§ 34.619)
5 Chapter 5: Texas Labels, Records and Enforcement
5.1 Installation and Service Labels (§§ 34.620–34.621) 5.2 Inspection/Test, Yellow and Red Labels and Impairment Notice 5.3 The Texas Recordkeeping and Retention Map 5.4 Prohibited Practices, Discipline, Enforcement and Penalties
6 Chapter 6: NFPA 72 Fundamentals, Power, Signals and Pathways
6.1 Identifying the Applicable NFPA Standards for TFM12 6.2 NFPA 72 Scope, Organization & Core Life Safety Definitions 6.3 NFPA 72 Documentation and Personnel Qualifications 6.4 Types of Equipment and Circuits: IDC, NAC, SLC and System Architectures 6.5 Signal Priority, Annunciation and Monitoring Integrity 6.6 Primary & Secondary Power Supply Calculations 6.7 Principles of Electricity and Notification Circuit Voltage Drop 6.8 Initiating & Notification Circuit Pathways (Class A, B, N, X) 6.9 Pathway Survivability, Shared Pathways and Circuit Separation
7 Chapter 7: Initiating Devices and Detection
7.1 Smoke, Heat & Flame Detection Principles & Spacing Rules 7.2 Gas Detection, Carbon Monoxide Detection and Special-Application Devices 7.3 Detector Selection and Environmental Limits 7.4 Duct Smoke Detectors, HVAC Controls & Specialized Sensors 7.5 Manual Fire Alarm Boxes, Waterflow Switches & Supervisory Initiating Devices 7.6 Sprinkler, Suppression and Releasing Service Interface
8 Chapter 8: Notification Appliances, Emergency Communications and Control Functions
8.1 Audible Notification Requirements & Sound Level Standards 8.2 Visible Notification Spacing, Synchronization & Candela Ratings 8.3 Emergency Communications Systems & Mass Notification Integration 8.4 Emergency Control Functions: Elevators, HVAC, Doors and Egress 8.5 Protected Premises Systems and the Sequence of Operation
9 Chapter 9: Wiring Methods, Supervising Stations and Inspection, Testing and Maintenance
9.1 NEC Article 760 Wiring Methods, Cable Classes & Circuit Protection 9.2 NEC Article 300 Wiring Methods and Installation Workmanship 9.3 Supervising Station Monitoring Systems & Signal Transmission Methods 9.4 Public Emergency Alarm Reporting Systems and Auxiliary Systems 9.5 Periodic Inspection, Testing & Impairment Procedures 9.6 System Acceptance Testing, Commissioning & Maintenance Records
1.4 Activities Not Regulated: The § 6002.155 Exemptions
Key Takeaways Explain This Topic AI
Section 6002.155 exempts licensing only; exempt persons must still ensure planning and installation follow the standards adopted in 28 TAC § 34.607 (§ 34.604).
A building-construction contractor is exempt only if a contract puts the installation under the direct supervision and certification of a registered firm's licensee, that firm assumes full responsibility, and the contractor does not plan, certify, lease, sell, service, or maintain systems.
A municipally licensed electrician may install single-station or interconnected multiple-station detectors in residences only if they are not connected to a control panel or outside alarm, do not transmit off premises, do not exceed 120 volts, and comply with the adopted NFPA 72.
Over-the-counter and mail-order sellers are exempt only if they do not plan, certify, install, service, or maintain the devices.
A registered firm employing an employee exempt under § 6002.155(10) must train and supervise that employee under § 6002.253 and keep lesson plans and annual competency test results under 28 TAC § 34.616(a)(2).
Last updated: August 2026
Why This Section Matters
Almost every enforcement case begins with someone who believed they were exempt. Section 6002.155 is written as a list of conditional exemptions: each one has qualifiers, and blowing one qualifier collapses the whole exemption. Expect TFM11 to present a fact pattern where one qualifier is violated.
28 TAC § 34.604 ties the rules to the statute: "The exceptions of Insurance Code § 6002.155 are applicable to the sections of this subchapter. Professionally exempt individuals or organizations are exempt from license requirements only and will be responsible for ensuring that planning and installation of fire detection or fire alarm devices are performed according to standards adopted in § 34.607 ... except when the planning and installation complies with a more recent edition of an adopted standard."
Exempt from the license. Never exempt from the code.
1. The Exemption List (§ 6002.155)
# Who is exempt The qualifiers that can destroy the exemption
(1) A building-construction individual or organization installing electrical wiring and devices that may include, in part, a fire alarm or detection system Must be party to a contract providing that the installation is performed under the direct supervision of and certified by a licensed employee/agent of a registered firm, and that the registered firm assumes full responsibility ; and the contractor must not plan, certify, lease, sell, service, or maintain systems
(2) An owner installing a device on their own property ; or installing a device, without charge , to protect their own personal property located on another's property Must not install on another's property as a normal business practice
(3) An individual licensed or authorized by a municipality as an electrician , installing fire/smoke detection in a single-family or multifamily residence Only single station detectors, or multiple station detectors interconnected so one actuates all — not connected to a control panel or an outside alarm, no off-premises signal, not more than 120 volts , and all installations must comply with the adopted edition of NFPA 72
(4) A seller of devices exclusively over-the-counter or by mail order Must not plan, certify, install, service, or maintain the devices
(5) A law enforcement agency, fire department, officer, or firefighter responding to an alarm in an official capacity Response only
(6) An engineer licensed under Texas law, acting within the practice of engineering Professional-engineer scope
(10) Certain employees of a registered firm working on residential single-station devices Firm must train and supervise under § 6002.253 and 28 TAC § 34.616(a)
- (The statute's list continues; the entries above are the ones that generate exam questions.)
- 2. The Electrician Exemption — Five Simultaneous Conditions
Subsection (3) is the most heavily tested exemption because every condition must hold at once:
The person holds a municipal electrician license or authority.
The occupancy is a single family or multifamily residence .
The devices are single station , or multiple station detectors interconnected so that actuation of one causes all alarms to operate.
The detectors are not connected to a control panel , not connected to an outside alarm , do not transmit a signal off the premises , and do not use more than 120 volts .
All installations comply with the adopted edition of NFPA 72 .
Worked example. A city-licensed electrician wires interconnected 120-volt smoke alarms in a new duplex. Exempt. The builder then asks him to run a low-voltage pair from one alarm to a cellular communicator so the alarms report to a monitoring company. The exemption is gone — the devices now transmit a signal off the premises. The work must be performed by or under the direct on-site supervision of a licensee of a registered firm.
3. Training and Supervising Exempt Employees (§ 6002.253)
When a registered firm employs an individual who is exempt under § 6002.155(10), the firm shall appropriately train and supervise that individual to ensure that:
Each installation complies with the adopted provisions of NFPA 72 or other adopted standards;
Each smoke or heat detector installed or sold carries a label or listing of approval by a testing laboratory approved by the department; and
The individual is knowledgeable in fire protection and the proper use and placement of detectors .
28 TAC § 34.616(a) implements this. Exempt persons selling, installing, and servicing residential single-station alarms must work under the supervision of a residential fire alarm superintendent (single station), a residential fire alarm superintendent, or a fire alarm planning superintendent . The registered firm must maintain documentation including lesson plans and annual test results demonstrating each exempt employee's competency regarding Chapter 6002, the adopted standards, and the parts of Subchapter F applicable to single-station devices.
4. Fact Patterns That Break the Exemption
Fact pattern Exempt? Why
General contractor pulls fire alarm cable under a contract naming a registered firm that supervises, certifies, and assumes full responsibility Yes All of § 6002.155(1) is satisfied
Same general contractor also signs the installation certificate No Certifying is outside the exemption; only the registered firm's licensee may certify
Big-box retailer sells listed smoke alarms at the counter Yes § 6002.155(4)
The same retailer offers $99 in-home installation No Installing defeats the mail-order/over-the-counter exemption
Warehouse owner installs a detector on his own building Yes § 6002.155(2)(A)
The same owner installs detectors in tenant suites he leases out, for a fee No Charging and installing on another's property as a business practice
City firefighter responds to a waterflow alarm and silences the panel to investigate Yes § 6002.155(5) response in an official capacity
Texas-licensed professional engineer seals a fire alarm design Yes § 6002.155(6); § 34.619(a) also allows a Texas registered PE to plan systems