Study guide

3.6 Training Schools, Instructors and the Residential Technician Course

Texas Fire Alarm Installer License Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Texas Insurance Code Chapter 6002 Foundations

1.1 Chapter 6002 Purpose, Scope & Statutory Definitions 1.2 State Preemption and the Limits of Local Regulation 1.3 Commissioner and SFMO Authority; Adopted Standards and Editions 1.4 Activities Not Regulated: The § 6002.155 Exemptions 1.5 Required Device Labels, Listings and Consumer Information

2 Chapter 2: Certificates of Registration and Company Operating Rules

2.1 Registration Certificates: Main Office, Branch Office and Single Station 2.2 Insurance Requirements for Registered Firms 2.3 Business Location, Designated Employee and Vehicle Identification (§ 34.610) 2.4 Ownership Changes, Officer Changes and Revised Certificates

3 Chapter 3: Individual Licenses, Qualifying Tests and Renewal

3.1 The Six Texas Fire Alarm Licenses and What Each May Do 3.2 License Applications, Fingerprinting and Criminal History 3.3 The Qualifying Tests: TFM11, TFM12, TFM13, TFM14 and Their References 3.4 NICET, ESA and Professional Engineer Substitutions 3.5 Fees, the Two-Year Renewal Cycle and Late Renewal 3.6 Training Schools, Instructors and the Residential Technician Course

4 Chapter 4: Texas Field Practice — Installation, Service, Monitoring and Certification

4.1 Sales, Installation and Service Rules (§ 34.616) 4.2 Monitoring Requirements for Registered Firms (§ 34.616(c)) 4.3 The Installation Certificate (SF035) and Its Distribution 4.4 The Three-Stage Installation Inspection (§ 34.618) 4.5 Fire Alarm Plans and Record Drawings (§ 34.619)

5 Chapter 5: Texas Labels, Records and Enforcement

5.1 Installation and Service Labels (§§ 34.620–34.621) 5.2 Inspection/Test, Yellow and Red Labels and Impairment Notice 5.3 The Texas Recordkeeping and Retention Map 5.4 Prohibited Practices, Discipline, Enforcement and Penalties

6 Chapter 6: NFPA 72 Fundamentals, Power, Signals and Pathways

6.1 Identifying the Applicable NFPA Standards for TFM12 6.2 NFPA 72 Scope, Organization & Core Life Safety Definitions 6.3 NFPA 72 Documentation and Personnel Qualifications 6.4 Types of Equipment and Circuits: IDC, NAC, SLC and System Architectures 6.5 Signal Priority, Annunciation and Monitoring Integrity 6.6 Primary & Secondary Power Supply Calculations 6.7 Principles of Electricity and Notification Circuit Voltage Drop 6.8 Initiating & Notification Circuit Pathways (Class A, B, N, X) 6.9 Pathway Survivability, Shared Pathways and Circuit Separation

7 Chapter 7: Initiating Devices and Detection

7.1 Smoke, Heat & Flame Detection Principles & Spacing Rules 7.2 Gas Detection, Carbon Monoxide Detection and Special-Application Devices 7.3 Detector Selection and Environmental Limits 7.4 Duct Smoke Detectors, HVAC Controls & Specialized Sensors 7.5 Manual Fire Alarm Boxes, Waterflow Switches & Supervisory Initiating Devices 7.6 Sprinkler, Suppression and Releasing Service Interface

8 Chapter 8: Notification Appliances, Emergency Communications and Control Functions

8.1 Audible Notification Requirements & Sound Level Standards 8.2 Visible Notification Spacing, Synchronization & Candela Ratings 8.3 Emergency Communications Systems & Mass Notification Integration 8.4 Emergency Control Functions: Elevators, HVAC, Doors and Egress 8.5 Protected Premises Systems and the Sequence of Operation

9 Chapter 9: Wiring Methods, Supervising Stations and Inspection, Testing and Maintenance

9.1 NEC Article 760 Wiring Methods, Cable Classes & Circuit Protection 9.2 NEC Article 300 Wiring Methods and Installation Workmanship 9.3 Supervising Station Monitoring Systems & Signal Transmission Methods 9.4 Public Emergency Alarm Reporting Systems and Auxiliary Systems 9.5 Periodic Inspection, Testing & Impairment Procedures 9.6 System Acceptance Testing, Commissioning & Maintenance Records

3.6 Training Schools, Instructors and the Residential Technician Course

Key Takeaways Explain This Topic AI

A registered firm, or an affiliate of a registered firm, is not eligible for approval as a training school (§ 6002.158(a); § 34.627(b)(3)).

The state fire marshal must approve or deny a training school application in a letter provided not later than the 60th day after receipt, and a denial must disclose specific reasons (§ 6002.158(b); § 34.613(c)(2)(B)).

An instructor must hold an APS, RAS, or FAL license and have at least three years of experience in fire alarm installation, service, or monitoring (§ 6002.158(c); § 34.613(c)(1)).

Approval for a training school or instructor is valid for one year (§ 6002.158(d)), and both approval fees are $50 for instructors and $500 for schools.

The RAL curriculum is at least seven hours: one hour on Chapter 6002 and the Fire Alarm Rules, one hour on NFPA 70, four and one-half hours combined on NFPA 72, NFPA 101 and the IRC, and one-half hour on monitoring household systems (§ 34.628).

Last updated: August 2026

Why This Section Matters

Even a technician who will never teach gets tested on this material, because the RAL pathway is the structural exception to "every license requires a state test." The hour breakdown in § 34.628 is exact and therefore very easy to write questions about.

1. Who May Be a Training School (§ 6002.158(a); § 34.627(b))

The applicant submits an application with the complete course or testing curriculum .

A registered firm, or an affiliate of a registered firm, is not eligible for approval as a training school. This independence rule prevents a company from certifying its own hires.

The application form is Form SF246 (Training School Approval Application), adopted in § 34.630(e). Approvals are not transferable and apply only to the entity named as responsible on the form; changing the responsible entity requires applying for and receiving a new approval .

The school must obtain approval of the outline of each RAL training course before conducting a class, and may only use SFMO-approved instructors .

Access obligation: after approval, the school must annually conduct, within 125 miles of each county with a population greater than 500,000 , at least two classes that are open to the public (§ 6002.158(f); § 34.627(b)(5) states the same rule keyed to the last decennial census and each calendar year from the approval date).

Timeline: the state fire marshal reviews the materials and approves or denies in a letter not later than the 60th day after receipt. A denial must disclose specific reasons , and the applicant may reapply at any time by addressing them.

2. Who May Be an Instructor (§ 6002.158(c); § 34.613(c)(1); § 34.627(a))

An instructor applicant must:

Hold a current fire alarm planning superintendent, residential fire alarm superintendent, or fire alarm technician license issued by the SFMO;

Submit a completed Instructor Approval Application, Form SF247 , signed by the applicant and accompanied by all fees; and

Furnish written documentation of at least three years of experience in fire alarm installation, service, or monitoring — unless the applicant has held an APS, RAS, or FAL license for three or more years .

Once approved, the instructor:

  • May provide training only through an approved training school (§ 34.627(a)(1));
  • Must teach the subjects in the approved outline submitted by the school (§ 34.627(a)(2)); and

Must carry the instructor's approval while providing training (§ 34.611(b)(2)).

Renewal is Form SF255 . Instructor approval is valid one year ; the fee is $50 initial and $50 renewal .

Note who is excluded. An AMT, RAS-SS, or RAL license does not qualify a person to be an approved instructor.

3. The RAL Curriculum (§ 6002.158(e); § 34.628)

The training curriculum must consist of at least seven hours of instruction on installing, servicing, and maintaining single-family and two-family residential fire alarm systems as defined by NFPA 72, allocated as follows:

  • Minimum time Subject
  • 1 hour Insurance Code Chapter 6002 and the Fire Alarm Rules
  • 1 hour The National Electric Code, NFPA 70

4½ hours Combined instruction on NFPA 72 , NFPA 101 (Life Safety Code) , and the International Residential Code for One- and Two-Family Dwellings

  • ½ hour Monitoring of household fire alarm systems
  • = 7 hours Total
  • The in-course examination (§ 6002.158(e))

Separate from the seven instructional hours, the course must include an examination on NFPA 72 for which at least one hour is allocated for completion . The examination must:

Consist of at least 25 questions ; and

Require the applicant to answer at least 80 percent correctly to pass.

Compare that with the SFMO tests: 50 questions at 70 percent . The RAL in-course exam is 25 questions at 80 percent . Mixing up these two number pairs is the most common error on this topic.

Section 34.613(b)(1) adds that the qualifying test given as part of RAL training must include questions regarding Insurance Code Chapter 6002 and Subchapter F — which is why the curriculum devotes a dedicated hour to it.

4. Summary Comparison

  • Training school approval Instructor approval
  • Application form SF246 SF247
  • Renewal form Renewal Application for Training School Approval SF255
  • Term 1 year 1 year
  • Initial fee $500 $50
  • Renewal fee $500 (one year) $50 (one year)
  • Eligibility bar May not be a registered firm or affiliate Must hold APS, RAS, or FAL + 3 years' experience
  • Decision deadline Approve or deny within 60 days , with reasons on denial —
  • Transferable? No No (§ 34.611(g))
  • Address/name change Written notice + fee within 14 days (§ 34.611(h)) Same
  • 5. Applying the Rules

Scenario A. A large registered alarm company wants to run its own SFMO-approved RAL school to train new hires.

→ Not eligible. § 6002.158(a) and § 34.627(b)(3) bar a registered firm or an affiliate of one from being an approved training school.

Scenario B. An RAS with four years of service experience applies to be an instructor.

→ Eligible. § 34.613(c)(1) accepts an APS, RAS, or FAL license plus three years of documented experience — and holding the qualifying license itself for three or more years also satisfies the experience requirement.

Scenario C. An approved school in Amarillo holds one public class per year and otherwise trains only private clients.

→ Non-compliant. § 34.627(b)(5) requires two or more classes open to the public each calendar year within 125 miles of each county with a population over 500,000.

Scenario D. A course runs seven hours and ends with a 20-question, 70-percent quiz.

→ Non-compliant twice over: § 6002.158(e) requires at least 25 questions and at least 80 percent to pass, with at least one hour allocated for the exam.