6.3 Indoor Air Quality (IAQ): Ventilation, Filtration, Humidity Control, and ASHRAE 62.2

Texas Air Conditioning and Refrigeration Contractor License Exam Exam

Track your progress as you read

Finished sections get a check mark.

1 Introduction & Exam Overview

About the Texas ACR Contractor Exam Open-Book Strategy and the Approved Reference Library

2 Chapter 1: Texas Licensing Laws & TDLR Regulations

1.1 TDLR Licensing Framework, Class A vs Class B Scope, and Technician Registration 1.2 Insurance, Financial Responsibility, Display of License, and Advertising Rules 1.3 TDLR Enforcement, Violations, Administrative Penalties, and Continuing Education

3 Chapter 2: Thermodynamics & Core HVAC Principles

2.1 Heat Transfer Principles: Conduction, Convection, Radiation, and Sensible vs Latent Heat 2.2 Temperature, Pressure, Enthalpy, and the Pressure-Temperature Relationship 2.3 System Airflow Fundamentals, CFM Calculations, and Total External Static Pressure

4 Chapter 3: Load Calculations & System Sizing (Manual J, S, D)

3.1 ACCA Manual J Load Calculations: Heat Gain, Heat Loss, and Building Envelope Factors 3.2 ACCA Manual S Equipment Selection and Manual D Duct Design Principles 3.3 Texas Climate Design Conditions, Solar Gain, and Infiltration Adjustments

5 Chapter 4: Refrigerants, EPA Section 608 & Low-GWP A2L Transition

4.1 Refrigerant Classifications (CFC, HCFC, HFC, HFO) and EPA Section 608 Rules 4.2 AIM Act Phasedown, Next-Gen Low-GWP Refrigerants (R-454B, R-32), and A2L Safety Rules 4.3 Refrigerant Recovery, Recycling, Reclamation, Leak Repair Thresholds, and Evacuation

6 Chapter 5: Refrigeration Cycle & Core System Components

5.1 The Vapor-Compression Refrigeration Cycle and System Component States 5.2 Compressors: Types (Scroll, Reciprocating, Rotary), Maintenance, and Failure Modes 5.3 Condensers, Evaporators, and Expansion Devices (TXV, EEV, Fixed Orifice) 5.4 Service Valves, Filter-Driers, Sight Glasses, and Solenoid & Check Valves

7 Chapter 6: Air Distribution, Ductwork & Indoor Air Quality

6.1 Duct Layouts, Materials, Insulation, Duct Sealing, and Friction Loss 6.2 Air Balancing, Blower Performance Curves, and Air Distribution Fittings 6.3 Indoor Air Quality (IAQ): Ventilation, Filtration, Humidity Control, and ASHRAE 62.2 6.4 Mechanical Ventilation Rates, Air Equipment, and Refrigeration Machinery Rooms

8 Chapter 7: Heating Systems, Gas Controls & Venting

7.1 Gas-Fired Heating: Natural Gas, LP, Burners, Heat Exchangers, and Gas Piping 7.2 Gas Furnace Venting Categories, Draft Hoods, and Combustion Air Requirements 7.3 Electric Resistance Heating and Heat Pump Operation in Heating & Defrost Modes 7.4 Clothes Dryer Exhaust and Product-Conveying Duct Systems 7.5 Combustion Testing and Analysis: CO, Oxygen, Stack Temperature, Draft, and Efficiency

9 Chapter 8: Electrical Systems, Controls & Troubleshooting

8.1 HVAC Electrical Fundamentals: Voltage, Current, Resistance, and Transformer Sizing 8.2 Electric Motors: PSC, ECM, Capacitor Sizing, Relays, Contactors, and Starters 8.3 Schematics Reading, Control Circuits (24V), Thermostats, and Diagnostic Sequence 8.4 Pressure and Safety Controls: High/Low Pressure, Oil Safety, Freeze Protection, and Head Pressure Control

10 Chapter 9: Mechanical Codes & Texas Local Standards (IMC, IFGC & UMC)

9.1 International Mechanical Code (IMC): Equipment Clearances, Access, and Support 9.2 International Fuel Gas Code (IFGC): Pipe Sizing, Materials, Purging, and Testing 9.3 Condensate Drain Piping, Trap Sizing, Secondary Drain Protection, and Auxiliary Pans 9.4 Uniform Mechanical Code vs. International Mechanical Code: Adoption, Differences, and Locating Code Answers 9.5 Refrigerant Line Sizing, Piping Materials, Brazing, Oil Return, and Pipe Support

11 Chapter 10: Commercial Refrigeration & Process Cooling Systems

10.1 Commercial Refrigeration Systems: Walk-in Freezers, Coolers, and Multi-Compressor Racks 10.2 Defrost Systems: Electric, Hot Gas, Off-Cycle, and Evaporator Pressure Regulators (EPR) 10.3 Hydronic Chilled Water Systems, Boilers, and Process Cooling Fundamentals

12 Chapter 11: Jobsite Safety, OSHA Compliance & Business Practice

11.1 OSHA Safety Standards: Fall Protection, Personal Protective Equipment (PPE), and Ladder Safety 11.2 Lockout/Tagout (LOTO), Electrical Safety, High-Pressure Gas Cylinder Handling 11.3 Contractor Business Operations: Contracts, Lien Laws, Permits, Inspections, and Warranties 11.4 OSHA 29 CFR Part 1904: Recording and Reporting Occupational Injuries and Illnesses

6.3 Indoor Air Quality (IAQ): Ventilation, Filtration, Humidity Control, and ASHRAE 62.2

Key Takeaways Explain This Topic AI

ASHRAE Standard 62.2 establishes residential continuous mechanical ventilation airflow rates using the formula Q_fan = 0.03 * A_floor + 7.5 * (N_br + 1).

Energy Recovery Ventilators (ERVs) exchange both sensible heat and latent moisture between incoming outdoor air and exhaust streams, making them superior to Heat Recovery Ventilators (HRVs) in humid Texas climates.

Air filtration efficiency is rated using Minimum Efficiency Reporting Value (MERV 1-16); MERV 8-11 filter general dust/pollen, while MERV 13+ filter sub-micron particles, smoke, and viral carrier droplets to meet IECC standards.

Maintaining indoor relative humidity between 30% and 60% is essential for IAQ; low airflow fan modes (350 CFM/ton) or dedicated whole-house dehumidifiers manage latent loads during humid shoulder seasons.

Carbon monoxide hazards require source control: maintaining combustion air supply under IFGC/IMC, inspecting heat exchangers, and taking immediate corrective action if ambient CO exceeds 35 ppm.

Last updated: August 2026

ASHRAE Standard 62.2 Residential Mechanical Ventilation Requirements

Modern residential construction techniques create highly airtight building envelopes to meet energy conservation codes. While tight building construction reduces heating and cooling energy waste, it traps indoor air pollutants—including volatile organic compounds (VOCs) off-gassing from building materials, carbon dioxide, formaldehyde, radon, pet dander, and excess moisture.

To maintain healthy indoor air quality (IAQ), ASHRAE Standard 62.2 ("Ventilation and Acceptable Indoor Air Quality in Residential Buildings") mandates continuous mechanical outdoor air ventilation in single-family homes and multi-family structures.

ASHRAE 62.2 Continuous Ventilation Airflow Formula

The total required continuous mechanical ventilation airflow rate ( Q fan Q_{\text{fan}} Q fan ​ ) in cubic feet per minute (CFM) is calculated using the standard ASHRAE 62.2-2016/2019 equation: Q fan = ( 0.03 × A floor ) + [ 7.5 × ( N br + 1 ) ] Q_{\text{fan}} = (0.03 \times A_{\text{floor}}) + [7.5 \times (N_{\text{br}} + 1)] Q fan ​ = ( 0.03 × A floor ​ ) + [ 7.5 × ( N br ​ + 1 )]

Where:

Q fan Q_{\text{fan}} Q fan ​ = Continuous mechanical ventilation airflow rate in CFM .

A floor A_{\text{floor}} A floor ​ = Total conditioned floor area of the dwelling in square feet (sq ft) .

N br N_{\text{br}} N br ​ = Number of bedrooms (must not be less than 1).

( N br + 1 ) (N_{\text{br}} + 1) ( N br ​ + 1 ) = Assumed number of occupants in the dwelling.

Sample Calculation:

Calculate the required continuous mechanical ventilation airflow for a 4-bedroom home with 3,000 sq ft of conditioned floor area: Q fan = ( 0.03 × 3000 ) + [ 7.5 × ( 4 + 1 ) ] = 90 + ( 7.5 × 5 ) = 90 + 37.5 = 127.5 CFM (round to 128 CFM) Q_{\text{fan}} = (0.03 \times 3000) + [7.5 \times (4 + 1)] = 90 + (7.5 \times 5) = 90 + 37.5 = 127.5\text{ CFM (round to 128 CFM)} Q fan ​ = ( 0.03 × 3000 ) + [ 7.5 × ( 4 + 1 )] = 90 + ( 7.5 × 5 ) = 90 + 37.5 = 127.5 CFM (round to 128 CFM)

Intermittent Ventilation Adjustment

If the mechanical ventilation system operates intermittently (controlled by an automated timer cycling fan operation on and off each hour) rather than 24/7 continuously, the fan airflow rate during the active run cycle must be increased proportionately using the ASHRAE 62.2 fractional schedule multiplier so that the total volume of fresh air delivered per day remains equivalent to continuous ventilation.

Mechanical Ventilation Systems: ERV vs HRV Mechanics

Mechanical outdoor ventilation air can be introduced using three core system configurations: Exhaust-Only (continuous bath exhaust fan), Supply-Only (fresh air intake tied to return plenum with motorized damper), or Balanced Ventilation using energy recovery equipment.

Heat Recovery Ventilator (HRV) Mechanics

A Heat Recovery Ventilator (HRV) contains a fixed air-to-air heat exchanger core (constructed of aluminum or synthetic plates). Outgoing warm indoor exhaust air passes through alternating channels beside incoming cold outdoor air without mixing streams.

Sensible Energy Exchange : HRVs transfer sensible heat only between air streams.

Climate Application : HRVs excel in cold, dry northern winter climates where the goal is to recover sensible heat from exhaust air without transferring interior moisture outside. HRVs are unsuitable for hot, humid Texas summers because they do not extract latent humidity from incoming outdoor fresh air.

Energy Recovery Ventilator (ERV) Mechanics

An Energy Recovery Ventilator (ERV) utilizes a permeable desiccant-treated core or rotating enthalpy wheel that allows air streams to transfer both sensible heat and latent moisture.

Total Enthalpy Exchange : ERVs transfer both sensible heat AND latent moisture .

Summer Operation in Texas : Hot, humid outdoor air entering the ERV passes across the desiccant core. Heat and moisture pass from incoming outdoor air into the cool, dry outgoing exhaust air stream. This pre-cools and pre-dehumidifies incoming outdoor ventilation air before it enters the living space.

Climate Recommendation : ERVs are strongly recommended across Texas Climate Zones 2 and 3 to prevent fresh air ventilation requirements from overloading central cooling equipment with excess humidity.

  • Feature Heat Recovery Ventilator (HRV) Energy Recovery Ventilator (ERV)
  • Heat Transfer Type Sensible Heat Only Sensible Heat + Latent Moisture
  • Core Construction Non-permeable metal/plastic plates Permeable desiccant-coated membrane / wheel

Texas Climate Suitability Poor (allows humidity ingress in summer) Excellent (pre-dehumidifies outdoor intake air)

  • Winter Operation Recovers sensible heat from exhaust Recovers sensible heat and prevents indoor over-drying
  • Air Filtration Standards and MERV Rating Classifications

Air filtration protects HVAC equipment coils and improves indoor air quality by removing airborne particulates. Filters are rated under ASHRAE Standard 52.2 using the Minimum Efficiency Reporting Value (MERV) scale, ranging from MERV 1 to MERV 16.

Comprehensive MERV Rating Table

MERV Rating Particle Size Efficiency Range Common Captured Contaminants Typical Filter Material & Pressure Drop

MERV 1 - 4 < 20 % < 20\% < 20% efficiency on 3.0 − 10.0 μ m 3.0 - 10.0\,\mu\text{m} 3.0 − 10.0 μ m Large dust, carpet fibers, lint, bug dust Fiberglass disposable panel filter ( 0.05 − 0.10 in. w.g. 0.05 - 0.10\text{ in. w.g.} 0.05 − 0.10 in. w.g. drop); equipment protection only

MERV 5 - 8 20 % − 70 % 20\% - 70\% 20% − 70% efficiency on 3.0 − 10.0 μ m 3.0 - 10.0\,\mu\text{m} 3.0 − 10.0 μ m Mold spores, dust mite debris, cement dust, hairspray Standard pleated synthetic filter ( 0.15 − 0.25 in. w.g. 0.15 - 0.25\text{ in. w.g.} 0.15 − 0.25 in. w.g. drop); residential baseline upgrade

MERV 9 - 12 > 85 % > 85\% > 85% efficiency on 3.0 − 10.0 μ m 3.0 - 10.0\,\mu\text{m} 3.0 − 10.0 μ m , > 50 % > 50\% > 50% on 1.0 − 3.0 μ m 1.0 - 3.0\,\mu\text{m} 1.0 − 3.0 μ m Auto emissions, fine flour, pet dander, lead dust High-efficiency 4-inch deep pleated media filter ( 0.20 − 0.30 in. w.g. 0.20 - 0.30\text{ in. w.g.} 0.20 − 0.30 in. w.g. drop)

MERV 13 - 16 > 90 % > 90\% > 90% efficiency on 1.0 − 3.0 μ m 1.0 - 3.0\,\mu\text{m} 1.0 − 3.0 μ m , > 75 % > 75\% > 75% on 0.3 − 1.0 μ m 0.3 - 1.0\,\mu\text{m} 0.3 − 1.0 μ m Bacteria, virus carriers, tobacco smoke, fine smog Deep-pleated mini-pleat media filter ( 0.25 − 0.40 in. w.g. 0.25 - 0.40\text{ in. w.g.} 0.25 − 0.40 in. w.g. drop); IECC / LEED requirement

HEPA (MERV 17-20) ≥ 99.97 % \ge 99.97\% ≥ 99.97% efficiency on 0.3 μ m 0.3\,\mu\text{m} 0.3 μ m particles Ultra-fine smoke, viral nuclei, radioactive dust HEPA filter cell ( 0.80 − 1.20 in. w.g. 0.80 - 1.20\text{ in. w.g.} 0.80 − 1.20 in. w.g. drop); requires dedicated booster blower

Critical Pressure Drop Hazard: Replacing a standard MERV 4 fiberglass filter with a high-resistance 1-inch MERV 13 filter inside a narrow filter grille can add 0.35 in. w.g. 0.35\text{ in. w.g.} 0.35 in. w.g. of static pressure drop, restricting blower airflow. To install MERV 13+ filtration without penalizing fan performance, contractors must install 4-inch or 5-inch deep media filter cabinets to expand filter surface area and keep face velocity low.

Indoor Humidity Control and Dehumidification Strategies

Indoor relative humidity (RH) directly influences human thermal comfort, health, and building durability. ASHRAE Standard 55 recommends maintaining indoor relative humidity between 30% and 60% .

Hazards of High Humidity ( > 60 % > 60\% > 60% RH)

Accelerates dust mite reproduction and fungal/mold spore growth on drywall and duct surfaces.

Causes occupant discomfort by inhibiting evaporative cooling from human skin, prompting occupants to lower thermostat setpoints needlessly.

Sensible Heat Ratio (SHR) and Latent Load Challenges

The Sensible Heat Ratio (SHR) represents the proportion of sensible cooling capacity relative to total cooling capacity: SHR = Q sensible Q total = Q sensible Q sensible + Q latent \text{SHR} = \frac{Q_{\text{sensible}}}{Q_{\text{total}}} = \frac{Q_{\text{sensible}}}{Q_{\text{sensible}} + Q_{\text{latent}}} SHR = Q total ​ Q sensible ​ ​ = Q sensible ​ + Q latent ​ Q sensible ​ ​

In modern insulated Texas homes, high-performance windows and high-R insulation reduce sensible heat gain while latent moisture gains (from occupants, showers, cooking, and ventilation) remain high. This lowers the required building SHR down to 0.65-0.70. Standard air conditioners operating at 400 CFM/ton have an SHR of ~0.75-0.80, which can satisfy sensible thermostat setpoints before extracting sufficient latent moisture.

Field Dehumidification Methods

Variable-Speed Low Airflow Fan Mode : Modern thermostats command variable-speed blowers to drop airflow to 325 - 350 CFM per ton during high-humidity calls. Lower airflow drops evaporator coil saturation temperature, increasing moisture condensation rate off the air stream.

Whole-House Dedicated Dehumidifiers : Installed parallel to the central HVAC return system, dedicated dehumidifiers extract 70-130 pints of water per day independently of cooling calls. They run during humid spring and fall shoulder seasons when cooling load is low but ambient humidity is high.

Hot Gas Reheat Coils : Used in commercial HVAC packages. Air is sub-cooled across an evaporator coil to remove moisture, then passed across a downstream hot gas reheat coil (fed by hot compressor discharge vapor) to raise air temperature back to neutral room delivery temperature.

Carbon Monoxide (CO) Hazards and Pollutant Source Control

Carbon monoxide (CO) is an odorless, colorless, toxic gas produced by incomplete combustion of fossil fuels (natural gas, LP, fuel oil). When inhaled, CO binds to blood hemoglobin with an affinity approximately 200 times greater than oxygen , forming carboxyhemoglobin and preventing cellular oxygen transfer.

CO Exposure Thresholds and Standards

EPA Outdoor Ambient Limit : 9 ppm over an 8-hour period.

OSHA 8-Hour Permissible Exposure Limit (PEL) : 50 ppm.

Indoor Action Threshold : If ambient air testing inside a home reveals CO concentrations exceeding 35 ppm , the technician must immediately turn off all fuel-burning appliances, evacuate occupants, ventilate the space, and locate the combustion leak source.

IAQ Source Control and Combustion Safety Rules

Combustion Air Provisions (IFGC Chapter 3) : Ensure fuel-burning furnaces and water heaters receive adequate combustion air (minimum 50 cu ft of room volume per 1,000 BTU/hr aggregate input rating for unconfined spaces).

Heat Exchanger Integrity Inspections : Inspect gas furnace heat exchangers annually for stress cracks or rust perforations that permit toxic flue gases to bleed directly into supply air distribution ducts.

Garages and Attached Structures : Maintain positive pressure in conditioned spaces relative to attached garages to prevent motor vehicle exhaust fumes from infiltrating living areas.