Study guide
11.4 OSHA 29 CFR Part 1904: Recording and Reporting Occupational Injuries and Illnesses
Texas Air Conditioning and Refrigeration Contractor License Exam Exam
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
About the Texas ACR Contractor Exam Open-Book Strategy and the Approved Reference Library
2 Chapter 1: Texas Licensing Laws & TDLR Regulations
1.1 TDLR Licensing Framework, Class A vs Class B Scope, and Technician Registration 1.2 Insurance, Financial Responsibility, Display of License, and Advertising Rules 1.3 TDLR Enforcement, Violations, Administrative Penalties, and Continuing Education
3 Chapter 2: Thermodynamics & Core HVAC Principles
2.1 Heat Transfer Principles: Conduction, Convection, Radiation, and Sensible vs Latent Heat 2.2 Temperature, Pressure, Enthalpy, and the Pressure-Temperature Relationship 2.3 System Airflow Fundamentals, CFM Calculations, and Total External Static Pressure
4 Chapter 3: Load Calculations & System Sizing (Manual J, S, D)
3.1 ACCA Manual J Load Calculations: Heat Gain, Heat Loss, and Building Envelope Factors 3.2 ACCA Manual S Equipment Selection and Manual D Duct Design Principles 3.3 Texas Climate Design Conditions, Solar Gain, and Infiltration Adjustments
5 Chapter 4: Refrigerants, EPA Section 608 & Low-GWP A2L Transition
4.1 Refrigerant Classifications (CFC, HCFC, HFC, HFO) and EPA Section 608 Rules 4.2 AIM Act Phasedown, Next-Gen Low-GWP Refrigerants (R-454B, R-32), and A2L Safety Rules 4.3 Refrigerant Recovery, Recycling, Reclamation, Leak Repair Thresholds, and Evacuation
6 Chapter 5: Refrigeration Cycle & Core System Components
5.1 The Vapor-Compression Refrigeration Cycle and System Component States 5.2 Compressors: Types (Scroll, Reciprocating, Rotary), Maintenance, and Failure Modes 5.3 Condensers, Evaporators, and Expansion Devices (TXV, EEV, Fixed Orifice) 5.4 Service Valves, Filter-Driers, Sight Glasses, and Solenoid & Check Valves
7 Chapter 6: Air Distribution, Ductwork & Indoor Air Quality
6.1 Duct Layouts, Materials, Insulation, Duct Sealing, and Friction Loss 6.2 Air Balancing, Blower Performance Curves, and Air Distribution Fittings 6.3 Indoor Air Quality (IAQ): Ventilation, Filtration, Humidity Control, and ASHRAE 62.2 6.4 Mechanical Ventilation Rates, Air Equipment, and Refrigeration Machinery Rooms
8 Chapter 7: Heating Systems, Gas Controls & Venting
7.1 Gas-Fired Heating: Natural Gas, LP, Burners, Heat Exchangers, and Gas Piping 7.2 Gas Furnace Venting Categories, Draft Hoods, and Combustion Air Requirements 7.3 Electric Resistance Heating and Heat Pump Operation in Heating & Defrost Modes 7.4 Clothes Dryer Exhaust and Product-Conveying Duct Systems 7.5 Combustion Testing and Analysis: CO, Oxygen, Stack Temperature, Draft, and Efficiency
9 Chapter 8: Electrical Systems, Controls & Troubleshooting
8.1 HVAC Electrical Fundamentals: Voltage, Current, Resistance, and Transformer Sizing 8.2 Electric Motors: PSC, ECM, Capacitor Sizing, Relays, Contactors, and Starters 8.3 Schematics Reading, Control Circuits (24V), Thermostats, and Diagnostic Sequence 8.4 Pressure and Safety Controls: High/Low Pressure, Oil Safety, Freeze Protection, and Head Pressure Control
10 Chapter 9: Mechanical Codes & Texas Local Standards (IMC, IFGC & UMC)
9.1 International Mechanical Code (IMC): Equipment Clearances, Access, and Support 9.2 International Fuel Gas Code (IFGC): Pipe Sizing, Materials, Purging, and Testing 9.3 Condensate Drain Piping, Trap Sizing, Secondary Drain Protection, and Auxiliary Pans 9.4 Uniform Mechanical Code vs. International Mechanical Code: Adoption, Differences, and Locating Code Answers 9.5 Refrigerant Line Sizing, Piping Materials, Brazing, Oil Return, and Pipe Support
11 Chapter 10: Commercial Refrigeration & Process Cooling Systems
10.1 Commercial Refrigeration Systems: Walk-in Freezers, Coolers, and Multi-Compressor Racks 10.2 Defrost Systems: Electric, Hot Gas, Off-Cycle, and Evaporator Pressure Regulators (EPR) 10.3 Hydronic Chilled Water Systems, Boilers, and Process Cooling Fundamentals
12 Chapter 11: Jobsite Safety, OSHA Compliance & Business Practice
11.1 OSHA Safety Standards: Fall Protection, Personal Protective Equipment (PPE), and Ladder Safety 11.2 Lockout/Tagout (LOTO), Electrical Safety, High-Pressure Gas Cylinder Handling 11.3 Contractor Business Operations: Contracts, Lien Laws, Permits, Inspections, and Warranties 11.4 OSHA 29 CFR Part 1904: Recording and Reporting Occupational Injuries and Illnesses
11.4 OSHA 29 CFR Part 1904: Recording and Reporting Occupational Injuries and Illnesses
Key Takeaways Explain This Topic AI
29 CFR Part 1904 is the only OSHA document on the TDLR/PSI approved reference list for the ACR exams, and Texas has no OSHA-approved State Plan for private employers, so federal Part 1904 applies directly to an ACR contractor.
The two partial exemptions are 10 or fewer employees at all times during the previous calendar year (1904.1) and low-hazard industries in Appendix A to Subpart B (1904.2); no construction code appears on that list, so NAICS 238220 HVAC contractors are never industry-exempt.
A case is recordable only if it is work-related (1904.5), a new case (1904.6), and meets a 1904.7 criterion: death, days away from work, restricted work or job transfer, medical treatment beyond first aid, loss of consciousness, or significant diagnosis by a physician or other licensed health care professional.
1904.7(b)(5)(ii) is a closed 14-item first-aid list; days away and restricted days start counting the day after the injury and may be capped at 180 calendar days under 1904.7(b)(3).
Record within 7 calendar days (1904.29(b)(3)), post the certified Form 300A from February 1 through April 30 (1904.32), retain records 5 years (1904.33), and report a fatality within 8 hours and a hospitalization, amputation, or loss of an eye within 24 hours (1904.39).
Last updated: August 2026
Why Part 1904 Is the Only OSHA Reference You Need
Every TDLR Air Conditioning and Refrigeration (ACR) contractor exam is open book, and the approved reference list names exactly one OSHA document: 29 CFR Part 1904, Recording and Reporting Occupational Injuries and Illnesses . Fall protection, ladders, and personal protective equipment live in 29 CFR Parts 1926 and 1910 — indispensable on a jobsite, but not the book on your table at the test center. Safety-area items that quote an OSHA rule come from Part 1904, so learn its structure well enough to open to the right section in seconds.
Texas has no OSHA-approved State Plan for private-sector employers, so federal OSHA enforces the Occupational Safety and Health Act directly at an ACR contractor's shop and every jobsite. There is no state variant to reconcile: Part 1904 as printed in the Code of Federal Regulations is the operative rule.
Who Must Keep Records: Two Partial Exemptions
Part 1904 relieves two groups of routine recordkeeping, and both exemptions are partial .
Size exemption — 1904.1. If your company had 10 or fewer employees at all times during the previous calendar year , you do not have to keep the OSHA injury and illness records. The count is company-wide rather than per establishment, and it is a peak count: an eleventh employee hired for one week in July defeats the exemption for the following year.
Industry exemption — 1904.2. An establishment classified in a low-hazard industry listed in Appendix A to Subpart B of Part 1904 is likewise relieved of routine recordkeeping. That appendix covers retail, finance, insurance, real estate, professional offices, and similar service industries; the lowest North American Industry Classification System ( NAICS ) code on it is 4412. No construction code appears anywhere in Appendix A. NAICS 238220, Plumbing, Heating, and Air-Conditioning Contractors , is not on the list — so a Texas ACR contractor with more than 10 employees keeps the log, full stop.
What neither exemption excuses. A partially exempt employer must still:
- report fatalities and severe outcomes under 1904.39 ;
- begin keeping records if OSHA notifies you in writing under 1904.41 ;
complete and return a Bureau of Labor Statistics ( BLS ) survey if the BLS notifies you under 1904.42 .
Separately, a construction establishment (NAICS 23) with 20–249 employees that is required to keep records must electronically submit its Form 300A data to OSHA by March 2 of the following year under 1904.41; establishments with 250 or more employees submit the same summary.