Study guide

1.3 TDLR Enforcement, Violations, Administrative Penalties, and Continuing Education

Texas Air Conditioning and Refrigeration Contractor License Exam Exam

Track your progress as you read

Finished sections get a check mark.

1 Introduction & Exam Overview

About the Texas ACR Contractor Exam Open-Book Strategy and the Approved Reference Library

2 Chapter 1: Texas Licensing Laws & TDLR Regulations

1.1 TDLR Licensing Framework, Class A vs Class B Scope, and Technician Registration 1.2 Insurance, Financial Responsibility, Display of License, and Advertising Rules 1.3 TDLR Enforcement, Violations, Administrative Penalties, and Continuing Education

3 Chapter 2: Thermodynamics & Core HVAC Principles

2.1 Heat Transfer Principles: Conduction, Convection, Radiation, and Sensible vs Latent Heat 2.2 Temperature, Pressure, Enthalpy, and the Pressure-Temperature Relationship 2.3 System Airflow Fundamentals, CFM Calculations, and Total External Static Pressure

4 Chapter 3: Load Calculations & System Sizing (Manual J, S, D)

3.1 ACCA Manual J Load Calculations: Heat Gain, Heat Loss, and Building Envelope Factors 3.2 ACCA Manual S Equipment Selection and Manual D Duct Design Principles 3.3 Texas Climate Design Conditions, Solar Gain, and Infiltration Adjustments

5 Chapter 4: Refrigerants, EPA Section 608 & Low-GWP A2L Transition

4.1 Refrigerant Classifications (CFC, HCFC, HFC, HFO) and EPA Section 608 Rules 4.2 AIM Act Phasedown, Next-Gen Low-GWP Refrigerants (R-454B, R-32), and A2L Safety Rules 4.3 Refrigerant Recovery, Recycling, Reclamation, Leak Repair Thresholds, and Evacuation

6 Chapter 5: Refrigeration Cycle & Core System Components

5.1 The Vapor-Compression Refrigeration Cycle and System Component States 5.2 Compressors: Types (Scroll, Reciprocating, Rotary), Maintenance, and Failure Modes 5.3 Condensers, Evaporators, and Expansion Devices (TXV, EEV, Fixed Orifice) 5.4 Service Valves, Filter-Driers, Sight Glasses, and Solenoid & Check Valves

7 Chapter 6: Air Distribution, Ductwork & Indoor Air Quality

6.1 Duct Layouts, Materials, Insulation, Duct Sealing, and Friction Loss 6.2 Air Balancing, Blower Performance Curves, and Air Distribution Fittings 6.3 Indoor Air Quality (IAQ): Ventilation, Filtration, Humidity Control, and ASHRAE 62.2 6.4 Mechanical Ventilation Rates, Air Equipment, and Refrigeration Machinery Rooms

8 Chapter 7: Heating Systems, Gas Controls & Venting

7.1 Gas-Fired Heating: Natural Gas, LP, Burners, Heat Exchangers, and Gas Piping 7.2 Gas Furnace Venting Categories, Draft Hoods, and Combustion Air Requirements 7.3 Electric Resistance Heating and Heat Pump Operation in Heating & Defrost Modes 7.4 Clothes Dryer Exhaust and Product-Conveying Duct Systems 7.5 Combustion Testing and Analysis: CO, Oxygen, Stack Temperature, Draft, and Efficiency

9 Chapter 8: Electrical Systems, Controls & Troubleshooting

8.1 HVAC Electrical Fundamentals: Voltage, Current, Resistance, and Transformer Sizing 8.2 Electric Motors: PSC, ECM, Capacitor Sizing, Relays, Contactors, and Starters 8.3 Schematics Reading, Control Circuits (24V), Thermostats, and Diagnostic Sequence 8.4 Pressure and Safety Controls: High/Low Pressure, Oil Safety, Freeze Protection, and Head Pressure Control

10 Chapter 9: Mechanical Codes & Texas Local Standards (IMC, IFGC & UMC)

9.1 International Mechanical Code (IMC): Equipment Clearances, Access, and Support 9.2 International Fuel Gas Code (IFGC): Pipe Sizing, Materials, Purging, and Testing 9.3 Condensate Drain Piping, Trap Sizing, Secondary Drain Protection, and Auxiliary Pans 9.4 Uniform Mechanical Code vs. International Mechanical Code: Adoption, Differences, and Locating Code Answers 9.5 Refrigerant Line Sizing, Piping Materials, Brazing, Oil Return, and Pipe Support

11 Chapter 10: Commercial Refrigeration & Process Cooling Systems

10.1 Commercial Refrigeration Systems: Walk-in Freezers, Coolers, and Multi-Compressor Racks 10.2 Defrost Systems: Electric, Hot Gas, Off-Cycle, and Evaporator Pressure Regulators (EPR) 10.3 Hydronic Chilled Water Systems, Boilers, and Process Cooling Fundamentals

12 Chapter 11: Jobsite Safety, OSHA Compliance & Business Practice

11.1 OSHA Safety Standards: Fall Protection, Personal Protective Equipment (PPE), and Ladder Safety 11.2 Lockout/Tagout (LOTO), Electrical Safety, High-Pressure Gas Cylinder Handling 11.3 Contractor Business Operations: Contracts, Lien Laws, Permits, Inspections, and Warranties 11.4 OSHA 29 CFR Part 1904: Recording and Reporting Occupational Injuries and Illnesses

1.3 TDLR Enforcement, Violations, Administrative Penalties, and Continuing Education

Key Takeaways Explain This Topic AI

TDLR Enforcement Division investigates complaints regarding unlicensed contracting, code non-compliance, fraud, and supervision failures.

TDLR may assess administrative civil penalties up to $5,000 per day per violation against individuals or companies violating Chapter 1302 or 16 TAC Chapter 75.

Contracting without a valid TDLR license is a Class C Misdemeanor under Texas criminal law, in addition to civil penalties and court injunctions.

ACR contractor licenses expire annually (every 12 months); late renewals incur monetary penalty multipliers.

Licensees must complete 8 hours of TDLR-approved continuing education annually, including mandatory 1 hour of Texas ACR laws and rules.

Last updated: August 2026

TDLR Enforcement Authority and Complaint Process

The Texas Department of Licensing and Regulation (TDLR) Enforcement Division is empowered to investigate complaints against licensed contractors, certified technicians, registered technicians, and unlicensed individuals operating in Texas. Enforcement actions protect consumers and maintain fair competition by penalizing dishonest practices, mechanical negligence, safety violations, and illegal contracting.

The Complaint Investigation Sequence

Complaint Intake: Complaints are submitted in writing by property owners, municipal building inspectors, or competing contractors alleging violations of Texas Occupations Code Chapter 1302 or 16 TAC Chapter 75.

Preliminary Review: Enforcement attorneys and investigators evaluate whether TDLR has jurisdiction over the alleged matter.

Formal Investigation: If jurisdiction is established, TDLR sends formal notice of the complaint to the respondent. TDLR investigators possess statutory subpoena power to compel production of job contracts, invoices, maintenance logs, employee records, and municipal permit records, and may conduct unannounced field inspections of jobsite installations.

Administrative Proceedings:

Dismissal: Case dismissed if evidence is insufficient to prove a rule violation.

Agreed Order: An informal settlement conference where the respondent agrees to specified administrative penalties, corrective work, or license probation.

Contested Hearing before SOAH: If an agreement cannot be reached, the case proceeds to a formal contested hearing before an Administrative Law Judge (ALJ) at the State Office of Administrative Hearings (SOAH) . The ALJ issues a Proposal for Decision, which is reviewed by the Executive Director or Commission for final sanctions.

Administrative Penalties and Disciplinary Sanctions

TDLR possesses broad authority to issue civil administrative penalties and restrict or revoke professional licenses.

Statutory Maximum Administrative Penalty

Under Texas Occupations Code Sec. 51.302 , incorporated for this program by 16 TAC Sec. 75.90 , TDLR may assess an administrative penalty of up to $5,000 per day per violation . (Sec. 1302.451 is sometimes cited for this, but that section covers emergency cease-and-desist orders and sets no penalty amount; the dollar authority lives in Chapter 51.)

Exam Rule: Each day a violation continues to occur constitutes a separate violation for penalty assessment purposes. For example, if an unlicensed contractor performs unauthorized work over a 10-day period, total potential administrative penalties can reach $50,000 ($5,000 × 10 days).

Statutory Penalty Assessment Factors

When determining the dollar amount of an administrative penalty or selecting license sanctions, TDLR is required by law to evaluate the following statutory criteria:

Harm Severity: The severity, gravity, and extent of potential or actual harm to public health, safety, or consumer property.

Economic Harm: The financial impact or property damage suffered by the consumer.

Violation History: The contractor's history of previous violations or disciplinary actions.

Deterrence Value: The monetary penalty amount necessary to deter future violations by the respondent and across the broader industry.

Good Faith: Efforts demonstrated by the licensee to correct the violation or remediate consumer losses.

Disciplinary Sanction Hierarchy

In addition to monetary penalties, TDLR may impose administrative sanctions against a licensee or certificate holder:

Formal Written Reprimand: Official administrative warning recorded in the licensee's permanent public record.

License Probation: Allowance of restricted contracting under specified conditions (e.g., mandatory inspections, submitting quarterly job logs, re-examination).

License Suspension: Temporary prohibition against engaging in ACR contracting for a specified calendar period.

License Revocation: Permanent cancellation of the contractor license. A person whose license is revoked cannot reapply for a new license for at least one full year from the effective date of revocation.

Violation Severity Class Example Violations Typical Administrative Sanction Range

Class A (Minor) Minor advertising omission, failure to notify TDLR of address change Written reprimand to $500 fine

Class B (Moderate) Failing to display license number on vehicle, failing to provide COI $500 to $1,500 fine per day

Class C (Serious) Contracting without local permits, employing unregistered technicians $1,500 to $3,000 fine per day + probation

Class D (Severe) Contracting without a license, performing unsafe work creating hazard $3,000 to $5,000 fine per day + revocation/injunction

Criminal Penalties for Contracting Without a License

In Texas, engaging in air conditioning and refrigeration contracting without holding a valid state contractor license is not merely an administrative infraction—it is a criminal offense.

Class C Misdemeanor

Under Texas Occupations Code Sec. 1302.453 , a person commits a criminal offense if the person engages in ACR contracting without holding a license issued under Chapter 1302, or if a contractor knowingly employs an unregistered or uncertified individual to perform contracting work. This offense is classified as a Class C Misdemeanor under the Texas Penal Code.

District Court Injunctions & Emergency Orders

In addition to criminal misdemeanor charges prosecuted in municipal or justice courts, TDLR and the Texas Attorney General may file suit in Travis County District Court or local district courts to obtain civil injunctions and emergency cease-and-desist orders against unlicensed operators. Violating a court injunction carries additional civil contempt fines and potential imprisonment.

Annual License Renewal and Continuing Education (CE)

To ensure contractors stay current with changing mechanical codes, safety standards, and state regulations, Texas requires annual license renewal and mandatory ongoing education.

Annual License Expiration Cycle

All Texas ACR contractor licenses, technician certifications, and technician registrations expire annually (every 12 months) from the original date of issuance. Contractors must submit their renewal application, pay the annual renewal fee, and verify insurance coverage prior to the expiration date.

Late Renewal Penalties

90 Days or Less Late: Renewal fee equals 1-1/2 times the standard renewal fee.

More Than 90 Days but Less Than 18 Months Late: Renewal fee equals 2 times the standard renewal fee.

18 Months to 3 Years Late: The license may still be renewed at 2 times the standard fee, but only with the executive director's approval .

More Than 3 Years Expired: The license cannot be renewed; the individual must meet current initial licensing requirements, submit a new application, and retake the licensing examination.

These tiers come from Texas Occupations Code Sec. 51.401 , TDLR's general enabling statute, which governs late renewal across every TDLR program.

Continuing Education (CE) Requirements

Under 16 TAC §75.25 , all licensed contractors must complete 8 hours of TDLR-approved continuing education during each 12-month license period prior to submitting their renewal application.

Mandatory 8-Hour CE Curriculum Breakdown

1 Hour: Mandatory instruction on Texas Air Conditioning and Refrigeration Laws and Rules (Occupations Code Chapter 1302 and 16 TAC Chapter 75).

7 Hours: Approved instruction on technical mechanical topics, including:

International Mechanical Code (IMC), International Fuel Gas Code (IFGC), and International Residential Code (IRC) updates

  • EPA Section 608 regulations, AIM Act transition, and A2L refrigerant safety
  • Electrical safety, controls, and motor diagnostics
  • ACCA Manual J, Manual S, and Manual D load calculation standards
  • Workplace health and safety (OSHA standards, Lockout/Tagout, fall protection)
  • Business practices, contract law, and municipal permitting

CE Compliance Note: CE hours must be provided by a TDLR-approved course provider. Course completion credits are transmitted electronically by the provider directly to TDLR's licensing database. A contractor cannot carry over excess CE hours from one license year to the next.

  • CE Component Hours Required Permitted Topic Scope
  • Texas ACR Laws & Rules 1 Hour Occupations Code 1302, 16 TAC Chapter 75, TDLR administrative updates
  • Technical & Safety Topics 7 Hours Mechanical codes (IMC/IFGC), A2L safety, electrical, load calculations, OSHA
  • Total Annual CE Requirement 8 Hours Mandatory every 12-month renewal cycle prior to license renewal