10.3 Urinals, Special Fixtures, & Interceptors
Texas Journeyman Plumber Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Licensing Laws, Board Rules, & Safety
1.1 TSBPE Laws, Board Rules, & Scope of Practice 1.2 Responsible Master Plumber (RMP) Supervision & Permitting 1.3 Jobsite Safety, OSHA Standards, & Trenching 1.4 Enforcement, Disciplinary Action, & Penalties
2 Chapter 2: Exam Format, Adopted Codes, & Definitions
2.1 Exam Format, Scoring, & Testing Logistics 2.2 Adopted Plumbing Codes & Jurisdictional Authority 2.3 Code Definitions & Trade Terminology
3 Chapter 3: General Regulations & Piping Installation
3.1 Approved Piping Materials & Standards 3.2 Pipe Hangers, Supports, & Spacing 3.3 Structural Protection, Sleeving, & Penetrations 3.4 System Testing & Inspection Requirements
4 Chapter 4: Drainage Systems & Pipe Sizing
4.1 Drainage Fixture Units (DFU) & Fixture Drains 4.2 Building Drains, Sewers, & Minimum Slopes 4.3 Cleanouts: Sizing, Clearances, & Locations 4.4 Sumps, Sewage Ejectors, & Indirect Waste Systems 4.5 Storm Drainage Systems
5 Chapter 5: Traps & Trap Seal Protection
5.1 Trap Design, Sizing, & Prohibited Traps 5.2 Trap Seal Protection, Trap Arms, & Trap Primers
6 Chapter 6: Venting Methods & Design
6.1 Vent Sizing, Developed Length, & Terminations 6.2 Individual, Common, & Relief Vents 6.3 Wet Venting, Circuit Venting, & Combination Systems 6.4 Air Admittance Valves (AAV) & Island Fixture Vents
7 Chapter 7: Potable Water Supply & Distribution
7.1 Water Supply Fixture Units (WSFU) & Pipe Sizing 7.2 Water Pressure, PRVs, & Thermal Expansion 7.3 Cross-Connection Control & Backflow Devices 7.4 Water Service, Metering, & System Disinfection
8 Chapter 8: Water Heaters & Scald Prevention
8.1 Water Heater Types, Sizing, & Installation 8.2 Temperature & Pressure (T&P) Relief Valves & Discharge 8.3 Combustion Air, Venting, & Scald-Prevention Mixing Valves
9 Chapter 9: Fuel Gas Piping Systems
9.1 Fuel Gas Properties & Piping Materials (IFGC / NFPA 54) 9.2 Gas Pipe Sizing & Longest Length Method 9.3 Gas Shutoff Valves, Regulators, & Pressure Testing
10 Chapter 10: Fixtures, Faucets, & Accessibility
10.1 Fixture Clearances & Accessibility Standards (ADA) 10.2 Water Conservation & Flush Rates 10.3 Urinals, Special Fixtures, & Interceptors 10.4 Fixture Fittings, Faucets, & Accessories
11 Chapter 11: Plumbing Math & Trade Calculations
11.1 45-Degree & Rolling Offset Calculations 11.2 Grade, Fall, & Invert Elevation Calculations 11.3 Volume, Capacity, & Hydrostatic Pressure Calculations
12 Chapter 12: Isometric Drawings & TSBPE Practical Exam
12.1 Isometric Drawing Principles & Piping Schematics 12.2 TSBPE 2-Story DWV Dollhouse Design & Layout 12.3 Water & Gas Piping Schematics for Practical Stations 12.4 Hands-On Shop Skills: Brazing, Soldering, & Flaring
10.3 Urinals, Special Fixtures, & Interceptors
Key Takeaways Explain This Topic AI
All wall-hung plumbing fixtures (water closets, urinals, bariatric lavatories) must be supported on concealed, heavy-duty structural in-wall carrier systems anchored directly to the structural slab or framing; fastening fixtures solely to drywall or partition studs is a major code violation.
Emergency eyewash and safety shower equipment (ANSI/ISEA Z358.1 & OSHA 1910.151) must deliver tepid water (60°F to 100°F) controlled by an ASSE 1071 mixing valve for at least 15 continuous minutes at specified minimum flow rates (Shower: 20 GPM at 30 psi; Eyewash: 0.4 GPM; Eye/Face wash: 3.0 GPM).
Emergency fixtures must be accessible within a 10-second travel time (approximately 55 feet) along an unobstructed, level path, with a single-motion valve actuator that opens in 1 second or less and remains open without being held.
Grease interceptors are divided into point-of-use Hydromechanical Grease Interceptors (HGI) sized by flow rate (GPM) and fixture volume, and outdoor Gravity Grease Interceptors (GGI) sized by retention time (minimum 500-750 gallons).
The 25% Rule mandates that grease interceptors must be fully pumped and cleaned whenever the combined floating grease layer and settled bottom solids layer exceed 25% of the total liquid operating depth to prevent grease carryover into the public sewer.
Last updated: August 2026
10.3 Urinals, Special Fixtures, & Interceptors
Commercial and institutional plumbing installations frequently involve specialized fixtures that require precise structural anchoring, life-safety hydraulic controls, and wastewater pretreatment devices. On the Texas Journeyman Plumber examination, the Texas State Board of Plumbing Examiners (TSBPE) tests candidates extensively on the installation of wall-hung fixture carriers , emergency eyewash and deluge shower systems (governed by ANSI/ISEA Z358.1 and OSHA 29 CFR 1910.151 ), and grease and oil interceptors .
A journeyman plumber must understand how to size, pipe, vent, and maintain these specialized systems to protect building occupants, structural integrity, and public sewer infrastructure.
1. Wall-Hung Fixtures & Structural In-Wall Carriers
Wall-hung plumbing fixtures—including wall-hung water closets, blowout/siphon-jet urinals, and institutional lavatories—offer superior sanitation because the floor beneath remains unobstructed for mopping and disinfection. +-----------------------------------------------------------------------------------+
- | WALL-HUNG FIXTURE CARRIER REQUIREMENTS |
- | |
- | - STRUCTURAL ANCHORAGE: Must be supported on heavy-gauge concealed in-wall |
- | structural cast iron or steel carrier frames. |
- | - LOAD TRANSFER: Carrier base feet must be bolted directly to the |
- | concrete floor slab with heavy anchor bolts. |
- | - WALL CONTACT: Fixture must NOT transfer cantilevered rotational |
- | stress to drywall, gypsum board, or finish partitions. |
- | - BARIATRIC RATING: Standard commercial carriers rated min 500 lbs (227 kg)|
- | Bariatric heavy-duty carriers rated 1,000 lbs (454 kg) |
- +-----------------------------------------------------------------------------------+
- The Cantilever Problem
When an adult sits on a wall-hung water closet, their body weight acts at a leverage distance of 20 to 28 inches from the wall face. This creates a severe rotational moment (torque) that pulls outward on top mounting studs and pushes inward on bottom studs.
Mandatory In-Wall Carrier Code Rules:
Prohibition of Drywall Fastening: Plumbing codes strictly prohibit fastening wall-hung fixtures solely to drywall, tile, plaster, or wood/metal partition stud faces using lag screws or toggle bolts. All weight must be carried by an in-wall carrier system conforming to ASME A112.6.1M .
Base Foot Anchoring: The heavy cast steel or iron feet of the carrier frame must be bolted directly to the structural concrete floor slab using heavy-duty mechanical wedge anchors or epoxy anchors.
Threaded Rod & Gasket Adjustment: Carrier support studs (typically four 5/8-inch alloy steel threaded rods) must be adjusted so that the back of the vitreous china fixture bears firmly against the finished wall without cracking the china. An approved neoprene or felt closet gasket seals the waste horn connection to prevent sewer gas and water leakage.
2. Emergency Eyewash & Safety Shower Equipment (ANSI/ISEA Z358.1)
Emergency eye, face, and body flush stations are required in industrial facilities, commercial kitchens, chemical laboratories, automotive battery charging areas, and water treatment plants where workers are exposed to hazardous, corrosive, or caustic substances. +-----------------------------------------------------------------------------------+
- | ANSI/ISEA Z358.1 & OSHA EMERGENCY FIXTURE RULES |
- | |
- | - TEPID WATER RANGE: 60°F to 100°F (15.6°C to 37.8°C) MANDATORY |
- | - FLUSH DURATION: Minimum 15 MINUTES continuous flow |
- | - EMERGENCY SHOWER FLOW: Minimum 20 GPM (75.7 L/min) at 30 psi flow pressure |
- | - EMERGENCY EYEWASH FLOW: Minimum 0.4 GPM (1.5 L/min) at 30 psi flow pressure |
- | - EYE/FACE WASH FLOW: Minimum 3.0 GPM (11.4 L/min) at 30 psi flow pressure |
- | - TRAVEL TIME / DISTANCE: Within 10 SECONDS (approx 55 ft) unobstructed path |
- | - VALVE ACTUATION: 1 SECOND or less; stay-open valve (hands-free) |
- +-----------------------------------------------------------------------------------+
- The Tepid Water Mandate
Water supplied to emergency fixtures must be tepid , defined strictly by ANSI Z358.1 as 60°F to 100°F (15.6°C to 37.8°C) :
Below 60°F (15.6°C): Water causes rapid hypothermia, cold shock, and premature cessation of flushing before chemicals are fully washed away.
Above 100°F (37.8°C): High temperatures accelerate chemical reaction rates with flesh and ocular tissue, driving caustic acids deeper into the cornea.
Thermostatic Mixing Valve Standard: Emergency equipment must be supplied through an ASSE 1071 certified thermostatic mixing valve . ASSE 1071 valves include an internal cold-water bypass mechanism that ensures full cold water flow continues even if the hot water supply fails.
Flow Rates and Durations
All emergency equipment must be capable of delivering continuous fluid for a minimum of 15 minutes : Total Emergency Water Volume = Flow Rate (GPM) × 15 minutes \text{Total Emergency Water Volume} = \text{Flow Rate (GPM)} \times 15\text{ minutes} Total Emergency Water Volume = Flow Rate (GPM) × 15 minutes
Emergency Deluge Shower: Minimum 20 GPM (75.7 L/min) at 30 psi → 20 × 15 = 300 gallons minimum supply.
Emergency Eyewash: Minimum 0.4 GPM (1.5 L/min) at 30 psi → 0.4 × 15 = 6 gallons minimum supply.
Eye/Face Wash Combination: Minimum 3.0 GPM (11.4 L/min) at 30 psi → 3.0 × 15 = 45 gallons minimum supply.
Physical Clearances and Heights
Location: Must be reached within 10 seconds of travel (approximately 55 feet / 16.8 meters) across a level, unobstructed path with zero intervening closed doors or stairs.
Shower Head Mounting Height: Between 82 and 96 inches (2083 to 2438 mm) above the finished floor, producing a spray pattern diameter of at least 20 inches at a height of 60 inches above the floor.
Eyewash Nozzle Height: Between 33 and 53 inches (838 to 1346 mm) above the finished floor, located at least 6 inches from any wall or obstruction.
Hands-Free Valve Actuator: The valve mechanism must open in 1 second or less upon a single manual push or pull action and must remain latched fully open without requiring the injured user to keep holding the actuator handle.
3. Grease Interceptors: Hydromechanical vs. Gravity Systems
Commercial food service establishments generate large volumes of Fats, Oils, and Grease (FOG) . When hot grease cools inside public sewer mains, it congeals into massive solid deposits ("fatbergs"), causing catastrophic sanitary sewer overflows. +-----------------------------------------------------------------------------------+
- | GREASE INTERCEPTOR CLASSIFICATIONS |
- | |
- | [HYDROMECHANICAL GREASE INTERCEPTOR (HGI)] |
- | - Point-of-use indoor or outdoor unit located near fixture. |
- | - Sized by Peak Flow Rate (GPM) and Grease Storage Capacity (lbs). |
- | - Utilizes flow control fitting with air intake vent to generate micro-bubbles. |
- | - Certified under ASME A112.14.3, PDI G-101, or CSA B481. |
- | |
- | [GRAVITY GREASE INTERCEPTOR (GGI)] |
- | - Large underground concrete/fiberglass dual-compartment tank installed outdoors. |
- | - Sized by Liquid Retention Volume (typically 500 to 2,000+ gallons). |
- | - Minimum 30-minute hydraulic retention time under peak sanitary discharge. |
- | - Certified under IAPMO/ANSI Z1001. |
- +-----------------------------------------------------------------------------------+
- Comparison of HGI and GGI Interceptors
- Technical Parameter Hydromechanical Grease Interceptor (HGI) Gravity Grease Interceptor (GGI)
- Primary Sizing Metric Flow Rate in Gallons Per Minute (GPM) Total Liquid Volume in Gallons
- Typical Capacity 20 to 100 GPM (40 to 200 lbs grease) 500 to 2,000+ gallons
Separation Principle Flow restriction + hydrodynamic air entrainment Natural gravity flotation & settling over time
Retention Time Under 2 minutes Minimum 30 minutes
Installation Location Under 3-compartment sink, floor-recessed in kitchen Buried outdoors in parking/driveway lane
- Flow Control Device Mandatory engineered orifice with air vent Not required (uses full gravity inlet line)
- Venting Requirement Flow control air vent + outlet trap vent Dedicated tank body vent + inlet/outlet DWV vents
- 4. Hydromechanical Grease Interceptor (HGI) Sizing Calculations
HGI units are sized based on the total liquid volume of connected fixtures and the required drain-down time period (1-minute or 2-minute drain period). +-----------------------------------------------------------------------------------+
- | HGI FLOW SIZING FORMULA WORKFLOW |
- | |
- | [STEP 1] Calculate Sink Volume: V_cubic = Length × Width × Depth (all inches) |
- | [STEP 2] Convert to Gallons: V_gallons = V_cubic / 231 cu in/gal |
- | [STEP 3] Apply 75% Fill Factor: V_actual = V_gallons × 0.75 |
- | [STEP 4] Calculate GPM Flow: Flow Rate (GPM) = V_actual / Drain Time (min) |
- +-----------------------------------------------------------------------------------+
Worked Sizing Example: A commercial restaurant installs a standard 3-compartment pot-washing sink. Each compartment measures 24 inches long × 24 inches wide × 14 inches deep. Calculate the required HGI flow rating based on a standard 2-minute drain-down period :
Calculate total volumetric capacity in cubic inches for all 3 compartments: V cubic = 3 × ( 24 in × 24 in × 14 in ) = 3 × 8 , 064 = 24 , 192 cu in V_{\text{cubic}} = 3 \times (24\text{ in} \times 24\text{ in} \times 14\text{ in}) = 3 \times 8,064 = 24,192\text{ cu in} V cubic = 3 × ( 24 in × 24 in × 14 in ) = 3 × 8 , 064 = 24 , 192 cu in
Convert cubic inches to total liquid gallons (1 gal = 231 cu in): V gallons = 24 , 192 231 = 104.73 gallons V_{\text{gallons}} = \frac{24,192}{231} = 104.73\text{ gallons} V gallons = 231 24 , 192 = 104.73 gallons
Apply the standard 75% (0.75) fixture fill factor (accounting for dish displacement and freeboard): V actual = 104.73 × 0.75 = 78.55 gallons V_{\text{actual}} = 104.73 \times 0.75 = 78.55\text{ gallons} V actual = 104.73 × 0.75 = 78.55 gallons
Calculate required discharge flow rate for a 2-minute drain period: Flow Rate (GPM) = 78.55 gal 2 min = 39.27 GPM \text{Flow Rate (GPM)} = \frac{78.55\text{ gal}}{2\text{ min}} = 39.27\text{ GPM} Flow Rate (GPM) = 2 min 78.55 gal = 39.27 GPM
Selection: Select the next largest standard certified HGI size: 50 GPM rating (with a certified 100 lb grease retention capacity).
The HGI Flow Control Device Rule
Every HGI must have an engineered flow control fitting installed immediately ahead of the inlet. The flow control orifice restricts inflow to the interceptor's certified GPM rating and incorporates an air intake vent that draws in room air. Micro-air bubbles attach to grease globules, accelerating their buoyancy rise to the surface.
5. Maintenance & The 25% Rule
Plumbing codes and municipal wastewater utility ordinances enforce the 25% Rule for all grease interceptors (both HGI and GGI). +-----------------------------------------------------------------------------------+
- | THE 25% GREASE MAINTENANCE RULE |
- | |
- | An interceptor MUST be completely pumped, cleaned, and refilled with clean |
- | water whenever the COMBINED THICKNESS of: |
- | |
- | [Top Floating FOG Layer] + [Bottom Settled Solids/Sludge Layer] |
- | |
- | reaches or exceeds TWENTY-FIVE PERCENT (25%) of the total liquid operating depth.|
- +-----------------------------------------------------------------------------------+
Consequence of Exceeding 25%: When grease and solids occupy > 25% of the tank depth, the effective retention volume is reduced, causing water velocity through the interceptor to increase dramatically. High-velocity liquid sweeps trapped grease straight through the baffles and into the municipal sewer main.
6. Sand, Oil, & Lint Interceptors
Specialized commercial occupancies require dedicated interceptors to capture non-grease contaminants: +-----------------------------------------------------------------------------------+
- | SPECIAL INTERCEPTOR CLASSIFICATIONS |
- | |
- | [OIL & SAND INTERCEPTORS] - Automotive shops, car washes, parking garages. |
- | - Must have a minimum 6-inch (152 mm) water seal trap. |
- | - Must be vented with two independent vapor vent pipes |
- | terminating independently to open outside air. |
- | |
- | [LINT INTERCEPTORS] - Commercial laundry facilities and laundromats. |
- | - Wire basket or removable mesh screen with <= 1/2" |
- | openings to prevent lint clogging DWV sewer lines. |
- +-----------------------------------------------------------------------------------+