Study guide

5.3 Basic Mechanics: Force, Work, Power & Mechanical Energy

City & Guilds 2365 Level 2 Diploma in Electrical Installations Exam

Track your progress as you read

Finished sections get a check mark.

1 Introduction & Qualification Overview

1.1 About the City & Guilds 2365 Level 2 Qualification 1.2 Study Strategy, Exam Technique & Resource Navigation

2 Health, Safety & Environmental Legislation, Risk Assessment & Permits

2.1 Statutory Framework & Health and Safety Law 2.2 Hazardous Substances, Incident Reporting & Welfare 2.3 Work Equipment, Manual Handling & PPE 2.4 Environmental Legislation, Pollution & Site Waste 2.5 Risk Assessments, Method Statements, Permits to Work & Safety Signs

3 Electrical Safety, Safe Isolation, Site Hazards & Emergencies

3.1 Safe Isolation Procedures & GS38 Compliance 3.2 Electrical Hazards & Electric Shock Physiology 3.3 Fire Safety, Site Supplies & Emergency Response 3.4 Accidents, First Aid, Emergency Procedures & Reporting

4 Working at Height & Access Equipment

4.1 Work at Height Regulations & Risk Management 4.2 Ladders, Stepladders & Podiums 4.3 Mobile Access Towers & Scaffolding Systems

5 Mathematical Principles, Units & Basic Mechanics

5.1 Mathematical Foundations & Transposition for Electricians 5.2 SI Units of Measurement in Electrotechnology 5.3 Basic Mechanics: Force, Work, Power & Mechanical Energy 5.4 Mass, Weight, Levers, Gears & Pulleys

6 Electron Theory, Resistance, Resistivity & DC Circuits

6.1 Resistance, Resistivity & Conductor Dimensions 6.2 Temperature Coefficient of Resistance 6.3 Ohm's Law, Power & Direct Current Calculations 6.4 Series, Parallel & Combination DC Circuits 6.5 Electron Theory, Conductors, Insulators & the Effects of Current

7 Magnetism, Electromagnetism & Transformers

7.1 Magnetic Fields, Flux & Solenoid Properties 7.2 Electromagnetic Induction & Motor/Generator Principles 7.3 Transformer Principles, Construction & Calculations

8 Alternating Current, Three-Phase Systems & Electronic Components

8.1 AC Waveform Generation & Key Values 8.2 AC Circuit Theory: Reactance, Impedance & Power Factor 8.3 Three-Phase Generation, Star-Delta & UK Distribution 8.4 Electronic Components in Electrical Systems

9 Industry Regulations, Technical Information & Drawings

9.1 Electrical Regulations, Standards & Part P 9.2 Electrical Drawings, Diagrams & BS EN 60617 Symbols 9.3 Technical Specifications, Schedules & Environmental Influences

10 Wiring Systems, Cables, Containment & Practical Installation

10.1 Thermoplastic, Armoured & Flexible Cables 10.2 Specialised Cables: MICC & Fire-Performance Cables 10.3 Conduit Systems: Steel & PVC 10.4 Trunking, Cable Tray & Cable Supports 10.5 Unit 204 Practical Skills: Tools, Preparation & Installing Wiring Systems

11 Final Circuits, Protective Devices, Alarm & Control Circuits

11.1 Lighting Circuits & Switching Arrangements 11.2 Power Circuits: Ring Final, Radial & Dedicated Circuits 11.3 Consumer Units, Distribution Boards & Protective Devices 11.4 Alarm, Emergency Lighting, Data & Control Circuits

12 Cable Selection & Structural Installation

12.1 Cable Current-Carrying Capacity & Correction Factors 12.2 Voltage Drop Principles & Calculations 12.3 Structural Integrity & Concealed Cable Routing

13 Supply Systems, Earthing, Shock Protection & Micro-Renewables

13.1 UK Electricity Supply Networks & Distribution 13.2 Earthing System Configurations: TN-S, TN-C-S (PME and PNB) & TT 13.3 Protective Conductors, Bonding & Earth Electrodes 13.4 Automatic Disconnection of Supply (ADS) & Maximum Zs 13.5 Micro-Renewable Energy Technologies

14 Electrical Inspection & Dead Testing Sequence

14.1 Inspection Principles & Testing Safety to GS38 14.2 Continuity Testing: Protective Conductors & Ring Circuits 14.3 Insulation Resistance & Polarity Verification

15 Live Testing, Certification & Handover

15.1 Live Testing: Earth Loop Impedance, PFC & RCD Testing 15.2 Certification, Handover & Commissioning

16 Communicating within Building Services Engineering (Unit 210)

16.1 The Construction Team: Site Management, Trades & Site Visitors 16.2 Information Sources: Legislation, Guidance & Workplace Documents 16.3 Customer Information, Company Policies & Limits of Authority 16.4 Communicating Effectively: Methods, Accessibility & Conflict

5.3 Basic Mechanics: Force, Work, Power & Mechanical Energy

Key Takeaways Explain This Topic AI

Mass (kg) is the constant quantity of matter contained within an object, whereas weight (N) is the downward gravitational force acting on that mass ( W = m × g W = m \times g W = m × g , where g = 9.81 m/s 2 g = 9.81\text{ m/s}^2 g = 9.81 m/s 2 on Earth).

Work done ( W W W ) in Joules is the product of applied force ( F F F in Newtons) and the distance moved in the direction of the force ( d d d in meters); lifting a mass vertically requires work equal to m × g × h m \times g \times h m × g × h .

Mechanical power ( P P P ) is the time rate of doing work ( P = W t = F × v P = \frac{W}{t} = F \times v P = t W ​ = F × v in Watts), and connects to rotating electric motor shafts via torque as P = 2 π N τ 60 P = \frac{2\pi N \tau}{60} P = 60 2 π N τ ​ .

Mechanical energy exists as gravitational potential energy ( E p = m g h E_p = mgh E p ​ = m g h ) and kinetic energy ( E k = 1 2 m v 2 E_k = \frac{1}{2}mv^2 E k ​ = 2 1 ​ m v 2 ); energy conservation dictates that mechanical and electrical losses dissipate primarily as thermal energy.

System efficiency ( η \eta η ) is the ratio of useful power output to total power input; determining the electrical input power required by an electromechanical drive requires dividing output power by efficiency ( P in = P out η P_{\text{in}} = \frac{P_{\text{out}}}{\eta} P in ​ = η P out ​ ​ ).

Last updated: October 2026

5.3 Basic Mechanics: Force, Work, Power & Mechanical Energy

Electricians do not work solely with electrical circuits in isolation; they install, connect, and maintain electromechanical systems including electric motors, winches, passenger lifts, conveyor belts, and air handling fans. Selecting appropriate cable sizes, circuit breakers, and starters for these machines requires understanding how mechanical forces, work done, shaft torque, and power relate directly to electrical demand.

  • Mass vs. Weight and Newton's Second Law
  • Mass vs. Weight

A fundamental physics principle frequently tested in electrotechnical examinations is the distinction between mass and weight:

Mass ( m m m ): The intrinsic quantity of matter contained in an object, measured in kilograms ( kg \text{kg} kg ) . Mass remains constant regardless of position or gravitational field strength.

Weight ( W W W ): The downward gravitational force exerted on a mass by Earth's gravity, measured in Newtons ( N \text{N} N ) .

Weight ( W ) = m × g \text{Weight } (W) = m \times g Weight ( W ) = m × g Where:

  • m m m = mass in kilograms ( kg \text{kg} kg )
  • g g g = acceleration due to gravity = 9.81 m/s 2 = 9.81\text{ m/s}^2 = 9.81 m/s 2 (standard terrestrial value)

For example, an industrial distribution transformer with a mass of 150 kg 150\text{ kg} 150 kg exerts a downward gravitational force (weight) of: W = 150 kg × 9.81 m/s 2 = 1 , 471.5 N W = 150\text{ kg} \times 9.81\text{ m/s}^2 = 1,471.5\text{ N} W = 150 kg × 9.81 m/s 2 = 1 , 471.5 N

Force and Newton's Second Law of Motion

A force is any interaction that, when unopposed, changes or tends to change the state of rest or uniform motion of an object. Newton's Second Law of Motion states that force is directly proportional to the rate of change of momentum:

F = m × a F = m \times a F = m × a Where:

  • F F F = force in Newtons ( N \text{N} N )
  • m m m = mass in kilograms ( kg \text{kg} kg )
  • a a a = acceleration in meters per second squared ( m/s 2 \text{m/s}^2 m/s 2 )

Definition of the Newton ( N \text{N} N ): One Newton is the force required to accelerate a mass of one kilogram at a rate of one meter per second squared ( 1 N = 1 kg ⋅ m/s 2 1\text{ N} = 1\text{ kg}\cdot\text{m/s}^2 1 N = 1 kg ⋅ m/s 2 ).

  • Mechanical Parameter Symbol Coherent SI Unit Formula Electrotechnical Application
  • Mass m m m Kilogram ( kg \text{kg} kg ) Base SI unit Equipment weight verification, cable tray loading

Weight (Gravity Force) W W W or F g F_g F g ​ Newton ( N \text{N} N ) W = m × g W = m \times g W = m × g Sizing fixings, brackets, catenary wires

Linear Force F F F Newton ( N \text{N} N ) F = m × a F = m \times a F = m × a Cable pulling winches, motor linear thrust

Work Done W W W Joule ( J \text{J} J ) W = F × d W = F \times d W = F × d Energy expended lifting loads or pulling cables

Mechanical Power P P P Watt ( W \text{W} W ) P = W t = F × v P = \frac{W}{t} = F \times v P = t W ​ = F × v Electric motor sizing, mechanical drive rating

Torque τ \tau τ Newton-meter ( N ⋅ m \text{N}\cdot\text{m} N ⋅ m ) τ = F × r \tau = F \times r τ = F × r Motor shaft turning effort, conduit bending effort

  • Work Done and Mechanical Energy
  • Work Done ( W W W )

In mechanics, work is done whenever a force acts upon an object causing it to move through a distance in the direction of the force:

W = F × d W = F \times d W = F × d Where:

  • W W W = work done in Joules ( J \text{J} J ) or Newton-meters ( N ⋅ m \text{N}\cdot\text{m} N ⋅ m )
  • F F F = applied force in Newtons ( N \text{N} N )
  • d d d = distance moved in the direction of the force in meters ( m \text{m} m )

When a load is lifted vertically against gravity, the force required equals the weight of the load ( F = m × g F = m \times g F = m × g ), yielding: W = m × g × h W = m \times g \times h W = m × g × h Where h h h is the vertical height lifted in meters.

Mechanical Energy: Potential and Kinetic

Energy is defined as the capacity to do work , measured in Joules ( J \text{J} J ) .

Gravitational Potential Energy ( E p E_p E p ​ ): The stored energy possessed by a body due to its elevated position in a gravitational field: E p = m × g × h E_p = m \times g \times h E p ​ = m × g × h

Kinetic Energy ( E k E_k E k ​ ): The energy possessed by an object due to its motion: E k = 1 2 m v 2 E_k = \frac{1}{2} m v^2 E k ​ = 2 1 ​ m v 2 Where m m m is mass in kg \text{kg} kg and v v v is velocity in meters per second ( m/s \text{m/s} m/s ).

According to the Principle of Conservation of Energy , energy cannot be created or destroyed; it can only be converted from one form to another. When an electric hoist lowers a heavy cable drum, potential energy converts into kinetic energy and thermal energy dissipated through friction in the brakes.

  • Mechanical Power and Torque
  • Mechanical Power ( P P P )

Power is the rate of doing work or the rate of energy transfer over time:

P = W t = F × d t P = \frac{W}{t} = \frac{F \times d}{t} P = t W ​ = t F × d ​ Since linear velocity is distance divided by time ( v = d t v = \frac{d}{t} v = t d ​ ), power can also be expressed as: P = F × v P = F \times v P = F × v Where:

  • P P P = power in Watts ( W \text{W} W , where 1 W = 1 J/s 1\text{ W} = 1\text{ J/s} 1 W = 1 J/s )
  • F F F = force in Newtons ( N \text{N} N )
  • v v v = constant velocity in meters per second ( m/s \text{m/s} m/s )

Note

Motor nameplates occasionally state power ratings in horsepower (hp) . The standard conversion is 1 hp = 746 W = 0.746 kW 1\text{ hp} = 746\text{ W} = 0.746\text{ kW} 1 hp = 746 W = 0.746 kW . A 5 hp 5\text{ hp} 5 hp motor delivers 5 × 746 W = 3 , 730 W = 3.73 kW 5 \times 746\text{ W} = 3,730\text{ W} = 3.73\text{ kW} 5 × 746 W = 3 , 730 W = 3.73 kW of mechanical output power at its shaft.

Torque ( τ \tau τ )

Torque (or turning moment) is the measure of the turning effort or rotational force exerted about a pivot axis:

τ = F × r \tau = F \times r τ = F × r Where:

  • τ \tau τ = torque in Newton-meters ( N ⋅ m \text{N}\cdot\text{m} N ⋅ m )
  • F F F = applied perpendicular force in Newtons ( N \text{N} N )

r r r = radius (perpendicular distance from the axis of rotation to the line of action) in meters ( m \text{m} m )

In electric motors, torque is produced by magnetic interactions between the rotor and stator. The rotational mechanical power available at the motor shaft is determined by its torque and rotational speed:

P = ω × τ = 2 π N τ 60 P = \omega \times \tau = \frac{2\pi N \tau}{60} P = ω × τ = 60 2 π N τ ​ Where:

  • P P P = shaft output power in Watts ( W \text{W} W )
  • N N N = rotational speed in revolutions per minute ( RPM \text{RPM} RPM )
  • τ \tau τ = shaft torque in Newton-meters ( N ⋅ m \text{N}\cdot\text{m} N ⋅ m )

ω \omega ω = angular velocity in radians per second ( rad/s \text{rad/s} rad/s ), where ω = 2 π N 60 \omega = \frac{2\pi N}{60} ω = 60 2 π N ​

Rearranging to calculate motor shaft torque: τ = 60 × P 2 π N \tau = \frac{60 \times P}{2\pi N} τ = 2 π N 60 × P ​

Efficiency and Electro-Mechanical Losses

No electromechanical machine transforms energy with 100 % 100\% 100% perfection. In every motor, generator, transformer, or gearbox, a portion of the input power is converted into non-useful thermal energy. ┌────────────────────────┐ ┌────────────────────────┐ ┌────────────────────────┐

  • │ INPUT POWER │ │ ELECTROMECHANICAL │ │ USEFUL POWER │
  • │ (Pin) │ ───► │ ENERGY LOSSES │ ───► │ OUTPUT (Pout) │
  • │ Electrical Supply (VI) │ │ • Copper I²R Losses │ │ Mechanical Shaft Power │
  • └────────────────────────┘ │ • Iron Core Losses │ └────────────────────────┘
  • │ • Friction & Windage │
  • └────────────────────────┘
  • The Efficiency Formula

Efficiency (symbol η \eta η , Greek letter eta) is the ratio of useful output power to total input power, expressed as a fraction or percentage:

η = Useful Output Power ( P out ) Total Input Power ( P in ) × 100 % \eta = \frac{\text{Useful Output Power } (P_{\text{out}})}{\text{Total Input Power } (P_{\text{in}})} \times 100\% η = Total Input Power ( P in ​ ) Useful Output Power ( P out ​ ) ​ × 100%

Rearranging to find the required electrical input power: P in = P out η P_{\text{in}} = \frac{P_{\text{out}}}{\eta} P in ​ = η P out ​ ​

Nature of Losses in Electromechanical Drives

Electrical Copper Losses ( I 2 R I^2 R I 2 R ): Heat generated in motor stator and rotor copper windings due to electrical resistance.

Magnetic Iron Losses: Energy lost in laminated silicon steel cores due to magnetic hysteresis (continuous molecular reorientation) and eddy currents (circulating currents induced in the core metal).

Mechanical Losses: Friction in motor bearings, gearbox gear meshes, and aerodynamic resistance ( windage ) caused by the internal cooling fan.

Tip

In efficiency calculations, Input Power is always greater than Output Power . If your calculated input power is smaller than the output power, you have accidentally inverted the formula.

Comprehensive Worked Example: Sizing an Electric Hoist Drive

Problem Statement: An electric hoist on a construction site is required to lift a pallet of electrical switchgear with a mass of 600 kg 600\text{ kg} 600 kg through a vertical height of 18 meters 18\text{ meters} 18 meters in 24 seconds 24\text{ seconds} 24 seconds .

The hoist gearbox has a mechanical efficiency of 80 % 80\% 80% ( η m = 0.80 \eta_m = 0.80 η m ​ = 0.80 ), and the single-phase 230 V 230\text{ V} 230 V electric motor driving it has an electrical efficiency of 75 % 75\% 75% ( η e = 0.75 \eta_e = 0.75 η e ​ = 0.75 ). Assuming a motor power factor of 1.0 1.0 1.0 , calculate:

The weight of the load in Newtons.

The mechanical work done in Joules.

The useful mechanical power output ( P out P_{\text{out}} P out ​ ) of the hoist.

The total combined system efficiency ( η total \eta_{\text{total}} η total ​ ).

The electrical power input ( P in P_{\text{in}} P in ​ ) drawn from the 230 V 230\text{ V} 230 V supply.

The steady-state operating current drawn by the motor.

Step-by-Step Solution:

Step 1: Weight of the load ( W W W ): W = m × g = 600 kg × 9.81 m/s 2 = 5 , 886 N W = m \times g = 600\text{ kg} \times 9.81\text{ m/s}^2 = 5,886\text{ N} W = m × g = 600 kg × 9.81 m/s 2 = 5 , 886 N

Step 2: Work done ( W W W ): W = F × d = 5 , 886 N × 18 m = 105 , 948 J ≈ 105.95 kJ W = F \times d = 5,886\text{ N} \times 18\text{ m} = 105,948\text{ J} \approx 105.95\text{ kJ} W = F × d = 5 , 886 N × 18 m = 105 , 948 J ≈ 105.95 kJ

Step 3: Useful mechanical power output ( P out P_{\text{out}} P out ​ ): P out = W t = 105 , 948 J 24 s = 4 , 414.5 W = 4.415 kW P_{\text{out}} = \frac{W}{t} = \frac{105,948\text{ J}}{24\text{ s}} = 4,414.5\text{ W} = 4.415\text{ kW} P out ​ = t W ​ = 24 s 105 , 948 J ​ = 4 , 414.5 W = 4.415 kW

Step 4: Combined system efficiency ( η total \eta_{\text{total}} η total ​ ): η total = η m × η e = 0.80 × 0.75 = 0.60 (or 60 % ) \eta_{\text{total}} = \eta_m \times \eta_e = 0.80 \times 0.75 = 0.60 \text{ (or } 60\%\text{)} η total ​ = η m ​ × η e ​ = 0.80 × 0.75 = 0.60 (or 60% )

Step 5: Electrical power input ( P in P_{\text{in}} P in ​ ): P in = P out η total = 4 , 414.5 W 0.60 = 7 , 357.5 W ≈ 7.36 kW P_{\text{in}} = \frac{P_{\text{out}}}{\eta_{\text{total}}} = \frac{4,414.5\text{ W}}{0.60} = 7,357.5\text{ W} \approx 7.36\text{ kW} P in ​ = η total ​ P out ​ ​ = 0.60 4 , 414.5 W ​ = 7 , 357.5 W ≈ 7.36 kW

Step 6: Motor operating current ( I I I ): I = P in V = 7 , 357.5 W 230 V ≈ 31.99 A I = \frac{P_{\text{in}}}{V} = \frac{7,357.5\text{ W}}{230\text{ V}} \approx 31.99\text{ A} I = V P in ​ ​ = 230 V 7 , 357.5 W ​ ≈ 31.99 A

This calculation demonstrates why mechanics is critical for electricians: the useful mechanical work rate requires only 4.41 kW 4.41\text{ kW} 4.41 kW , but due to cumulative losses, the electrical installation must supply 7.36 kW 7.36\text{ kW} 7.36 kW ( 32 A 32\text{ A} 32 A ), dictating a dedicated 32 A 32\text{ A} 32 A or 40 A 40\text{ A} 40 A circuit with suitably rated 6 mm 2 6\text{ mm}^2 6 mm 2 or 10 mm 2 10\text{ mm}^2 10 mm 2 conductors.

Loading diagram... Power Flow and Loss Distribution in an Electromechanical Hoist Installation