Study guide
13.5 Micro-Renewable Energy Technologies
City & Guilds 2365 Level 2 Diploma in Electrical Installations Exam
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Qualification Overview
1.1 About the City & Guilds 2365 Level 2 Qualification 1.2 Study Strategy, Exam Technique & Resource Navigation
2 Health, Safety & Environmental Legislation, Risk Assessment & Permits
2.1 Statutory Framework & Health and Safety Law 2.2 Hazardous Substances, Incident Reporting & Welfare 2.3 Work Equipment, Manual Handling & PPE 2.4 Environmental Legislation, Pollution & Site Waste 2.5 Risk Assessments, Method Statements, Permits to Work & Safety Signs
3 Electrical Safety, Safe Isolation, Site Hazards & Emergencies
3.1 Safe Isolation Procedures & GS38 Compliance 3.2 Electrical Hazards & Electric Shock Physiology 3.3 Fire Safety, Site Supplies & Emergency Response 3.4 Accidents, First Aid, Emergency Procedures & Reporting
4 Working at Height & Access Equipment
4.1 Work at Height Regulations & Risk Management 4.2 Ladders, Stepladders & Podiums 4.3 Mobile Access Towers & Scaffolding Systems
5 Mathematical Principles, Units & Basic Mechanics
5.1 Mathematical Foundations & Transposition for Electricians 5.2 SI Units of Measurement in Electrotechnology 5.3 Basic Mechanics: Force, Work, Power & Mechanical Energy 5.4 Mass, Weight, Levers, Gears & Pulleys
6 Electron Theory, Resistance, Resistivity & DC Circuits
6.1 Resistance, Resistivity & Conductor Dimensions 6.2 Temperature Coefficient of Resistance 6.3 Ohm's Law, Power & Direct Current Calculations 6.4 Series, Parallel & Combination DC Circuits 6.5 Electron Theory, Conductors, Insulators & the Effects of Current
7 Magnetism, Electromagnetism & Transformers
7.1 Magnetic Fields, Flux & Solenoid Properties 7.2 Electromagnetic Induction & Motor/Generator Principles 7.3 Transformer Principles, Construction & Calculations
8 Alternating Current, Three-Phase Systems & Electronic Components
8.1 AC Waveform Generation & Key Values 8.2 AC Circuit Theory: Reactance, Impedance & Power Factor 8.3 Three-Phase Generation, Star-Delta & UK Distribution 8.4 Electronic Components in Electrical Systems
9 Industry Regulations, Technical Information & Drawings
9.1 Electrical Regulations, Standards & Part P 9.2 Electrical Drawings, Diagrams & BS EN 60617 Symbols 9.3 Technical Specifications, Schedules & Environmental Influences
10 Wiring Systems, Cables, Containment & Practical Installation
10.1 Thermoplastic, Armoured & Flexible Cables 10.2 Specialised Cables: MICC & Fire-Performance Cables 10.3 Conduit Systems: Steel & PVC 10.4 Trunking, Cable Tray & Cable Supports 10.5 Unit 204 Practical Skills: Tools, Preparation & Installing Wiring Systems
11 Final Circuits, Protective Devices, Alarm & Control Circuits
11.1 Lighting Circuits & Switching Arrangements 11.2 Power Circuits: Ring Final, Radial & Dedicated Circuits 11.3 Consumer Units, Distribution Boards & Protective Devices 11.4 Alarm, Emergency Lighting, Data & Control Circuits
12 Cable Selection & Structural Installation
12.1 Cable Current-Carrying Capacity & Correction Factors 12.2 Voltage Drop Principles & Calculations 12.3 Structural Integrity & Concealed Cable Routing
13 Supply Systems, Earthing, Shock Protection & Micro-Renewables
13.1 UK Electricity Supply Networks & Distribution 13.2 Earthing System Configurations: TN-S, TN-C-S (PME and PNB) & TT 13.3 Protective Conductors, Bonding & Earth Electrodes 13.4 Automatic Disconnection of Supply (ADS) & Maximum Zs 13.5 Micro-Renewable Energy Technologies
14 Electrical Inspection & Dead Testing Sequence
14.1 Inspection Principles & Testing Safety to GS38 14.2 Continuity Testing: Protective Conductors & Ring Circuits 14.3 Insulation Resistance & Polarity Verification
15 Live Testing, Certification & Handover
15.1 Live Testing: Earth Loop Impedance, PFC & RCD Testing 15.2 Certification, Handover & Commissioning
16 Communicating within Building Services Engineering (Unit 210)
16.1 The Construction Team: Site Management, Trades & Site Visitors 16.2 Information Sources: Legislation, Guidance & Workplace Documents 16.3 Customer Information, Company Policies & Limits of Authority 16.4 Communicating Effectively: Methods, Accessibility & Conflict
13.5 Micro-Renewable Energy Technologies
Key Takeaways Explain This Topic AI
Unit 203 lists solar thermal, ground source and air source heat pumps, biomass, solar PV, micro-wind, micro-hydro, heat-led micro-CHP, rainwater harvesting and greywater re-use.
Solar PV produces d.c. that an inverter converts to a.c.; generators up to 16 A per phase connect under G98 (notify the DNO within 28 days of commissioning), and larger ones need prior approval under G99.
Heat pumps move heat from the air or ground using a refrigeration cycle, typically delivering 3 to 4 units of heat for each unit of electricity (the COP).
Heat-led micro-CHP generates electricity as a by-product while producing the heat the building needs.
Installation requirements include planning or permitted development, Building Regulations, BS 7671, DNO connection rules, MCS certification for export payments and grants, and location factors such as orientation, wind, head and flow.
Last updated: October 2026
13.5 Micro-Renewable Energy Technologies
Unit 203 learning outcome 6 (3 of the 40 test questions) asks you to describe the types of micro-renewable energy, identify the requirements for installing them (legal, regulatory and location), and identify their advantages and disadvantages. The range lists ten technologies: solar thermal (hot water), ground source heat pump, air source heat pump, biomass, solar photovoltaic, micro-wind, micro-hydro, micro-combined heat and power (heat led), rainwater harvesting and greywater re-use .
- Technologies That Produce Heat
- Solar thermal (hot water)
Collectors on the roof (flat-plate or evacuated-tube) absorb heat from the sun. A pump circulates a water and glycol (antifreeze) solution through a sealed loop to a coil in a twin-coil hot water cylinder . A differential temperature controller runs the pump only when the collector is hotter than the cylinder. A boiler coil or immersion heater tops up the temperature when solar input is low. The electrician supplies the pump station and controller and wires the temperature sensors.
Heat pumps (air source and ground source)
A heat pump moves heat from a low-temperature source to the building using a vapour-compression refrigeration cycle :
Evaporator : cold refrigerant absorbs heat from the outside air or a ground loop and evaporates.
Compressor : an electrically driven compressor raises the refrigerant's pressure and temperature.
Condenser : the hot refrigerant gives up its heat to the heating water and condenses.
Expansion valve : the pressure drops and the cycle repeats.
The coefficient of performance (COP) is the heat delivered divided by the electrical energy used; typical values are about 3 to 4. Heat pumps work best with low flow temperatures, such as underfloor heating or larger radiators.
Air source (ASHP) : an outdoor unit extracts heat from the air. It is cheaper to install but less efficient in very cold weather, and the unit needs careful siting for noise and airflow.
Ground source (GSHP) : pipes in horizontal trenches (needing a large area of land) or vertical boreholes extract heat from the ground, which stays at a steadier temperature.
The electrician provides a dedicated circuit sized for the unit's running and starting current, with the protective device and RCD type the manufacturer specifies, and a local isolator.
Biomass
Boilers or stoves burn wood pellets, wood chips or logs. They need space for fuel storage and access for deliveries, a suitable flue, and regular ash removal. In smoke control areas only approved (exempt) appliances may be used. Biomass is treated as low carbon because new growth reabsorbs the carbon dioxide released.
Micro-CHP (heat led)
A micro combined heat and power unit, usually gas-fired, uses a small engine, Stirling engine or fuel cell to produce heat for the building and electricity as a by-product . "Heat led" means it runs when the building needs heat, so its electrical output follows the heating demand.
- Technologies That Produce Electricity
- Solar photovoltaic (PV)
PV cells convert daylight directly into d.c. electricity. Panels are connected in strings , and an inverter converts the d.c. into a.c. synchronised with the supply. The installation needs d.c.-rated isolators, an a.c. isolator, a generation meter and warning labels, and must meet BS 7671 Section 712. Output depends on orientation (south-facing is best in the UK), tilt and shading . Battery storage is increasingly added; Amendment 4 introduced a new Chapter 57 for stationary secondary batteries.
Connection to the network : generators rated up to 16 A per phase connect under Engineering Recommendation G98 , with the DNO notified within 28 days of commissioning. Larger systems need the DNO's approval before connection under G99 .
Micro-wind
Small wind turbines on masts or buildings drive generators, usually through an inverter. They need a good average wind speed and smooth airflow; turbines on buildings in towns often perform poorly because of turbulence. Planning, noise, vibration and mast structure all need considering.
Micro-hydro
A turbine driven by flowing water generates electricity continuously where a suitable stream or river has enough head (height difference) and flow . Schemes usually need permissions such as an abstraction licence from the environmental regulator, and protection for fish and wildlife.
- Technologies That Save Water
- Rainwater harvesting
Rainwater from roofs is filtered into a storage tank (often underground), and a pump supplies non-drinking uses such as WC flushing, washing machines and garden taps. A mains top-up feeds the tank through an air gap so that drinking water cannot be contaminated. The electrician wires the pump and its control panel.
Greywater re-use
Lightly used water from baths, showers and basins is collected, filtered or treated, and stored for WC flushing or garden use. It must not be stored for long because bacteria can grow, and the pipework must be clearly marked. The electrician wires the pumps, treatment units and controls.
Loading diagram... Grid-Connected Solar PV System
Installation Requirements
Requirement What to consider
Legal Planning permission or permitted development (size, position, listed buildings and conservation areas); Building Regulations (structural loading of roofs, Part P electrical work, Part L energy efficiency, Part G for hot water systems); water regulations for rainwater and greywater systems; abstraction licences for micro-hydro; smoke control rules for biomass.
Regulatory BS 7671 (for example Section 712 for PV and Chapter 57 for batteries), DNO connection under G98 or G99, manufacturers' instructions, F-gas rules for work on heat pump refrigerant circuits, and MCS (Microgeneration Certification Scheme) certification of the installer and products, which is normally needed to receive Smart Export Guarantee payments or grants such as the Boiler Upgrade Scheme.
Location Orientation, tilt and shading (PV and solar thermal); roof strength and space; average wind speed and turbulence (micro-wind); head and flow (micro-hydro); land area or borehole access (GSHP); outdoor unit position and noise (ASHP); fuel storage and delivery access (biomass); space for tanks (rainwater and greywater).
Advantages and Disadvantages
Technology Advantages Disadvantages
Solar thermal Free heat for hot water; low running costs; low maintenance Needs a suitable roof and cylinder; little output in winter; needs a back-up heat source
Air source heat pump High efficiency; no fuel deliveries; can also provide cooling Less efficient in very cold weather; outdoor unit noise; may need larger radiators
Ground source heat pump Very efficient with a steady source temperature; long life High installation cost; needs land or boreholes
Biomass Low net carbon; can use local fuel Fuel storage and handling; ash and emissions; needs a flue
Solar PV Free electricity; export income; silent with few moving parts Daylight only and variable; high initial cost; inverter replacement during its life
Micro-wind Can generate day and night when windy Needs a good wind site; planning issues; noise and vibration; poor in urban turbulence
Micro-hydro Continuous, reliable output Very site-specific; permissions needed; environmental impact
Micro-CHP (heat led) Uses one fuel for both heat and power efficiently Usually still burns fossil fuel; generates only when heat is needed
Rainwater harvesting Cuts mains water use and bills; reduces surface water run-off Tank cost and space; pump energy; maintenance
- Greywater re-use Saves water Needs treatment and maintenance; cannot be stored for long; hygiene risk
- Related Low-Carbon Installations
Battery storage : stores surplus PV output for use later; installed to BS 7671 Chapter 57 (new in Amendment 4) and the manufacturer's instructions.
EV charging points (BS 7671 Section 722): on a PME supply an outdoor charge point needs measures against a broken PEN conductor, such as an open-PEN protection device, a TT earth electrode or an isolating transformer, and the right RCD protection (for example a Type A RCD with a 6 mA d.c. detecting device, or a Type B RCD). Amendment 4 also recognises RDC protective devices for EV charging.