Study guide
7.2 Spreader Plates, Outrigger Mats & Setup
IPAF MEWP Operator PAL Card
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: The IPAF MEWP Operator Course & PAL Card
1.1 The IPAF MEWP Operator Course, Theory Test & PAL Card
2 Chapter 2: UK Health, Safety & Statutory Regulations
2.1 Health and Safety at Work etc. Act 1974 (HASAWA) 2.2 Lifting Operations and Lifting Equipment Regulations 1998 (LOLER) 2.3 Provision and Use of Work Equipment Regulations 1998 (PUWER) 2.4 Work at Height Regulations 2005 (WAHR) & Hierarchy of Control
3 Chapter 3: British Standards, Design Classifications & Kinematics
3.1 BS 8460:2025 Code of Practice & the User's Responsibilities 3.2 BS EN 280-1 & ISO 16368 Design Groups (A and B) 3.3 Travel Types (Type 1, Type 2, Type 3) & IPAF Categories
4 Chapter 4: MEWP Categories, Machine Selection & Specifications
4.1 Static Platforms: Category 1a (Static Vertical) and Category 1b (Static Boom) 4.2 Mobile Platforms: Category 3a (Mobile Vertical) and Category 3b (Mobile Boom) 4.3 IPAF Categories, PAVs, Specialist Units & MEWP Selection
5 Chapter 5: Pre-Use Inspections & Daily Maintenance
5.1 Walk-Around Visual Inspection Protocol 5.2 Running Gear, Wheels & Tyre Management 5.3 Documentation, Operator Manuals & Daily Logbook Records
6 Chapter 6: Safety Systems, Controls & Emergency Lowering
6.1 Dual Control Station Operation & Interlocks 6.2 Load Sensing, Tilt Alarms & Anti-Entrapment Devices 6.3 Emergency Descent Systems & Defect Quarantine
7 Chapter 7: Ground Assessment, Outriggers & Stability Physics
7.1 Ground Bearing Capacity & Subsurface Hazards 7.2 Spreader Plates, Outrigger Mats & Setup 7.3 Platform Loading, Centre of Gravity & Dynamic Forces
8 Chapter 8: Environmental Hazards, Overhead Clearances & Safe Operations
8.1 Wind Speed Dynamics & Adverse Weather 8.2 Overhead Power Lines & HSE GS6 8.3 Manoeuvring, Travelling & Collision Avoidance 8.4 Parking, Securing & Transporting MEWPs, and Other Site Hazards
9 Chapter 9: Fall Protection, Catapult Effect & Emergency Rescue
9.1 Fall Protection Policy & IPAF Technical Guidance H1 9.2 PFPE Inspection, Anchor Points & Catapult Physics 9.3 Recovery & Rescue Planning and Suspension Trauma
7.2 Spreader Plates, Outrigger Mats & Setup
Key Takeaways Explain This Topic AI
Spreader plates (outrigger mats) expand the contact surface area of an outrigger shoe, reducing applied pressure below the allowable ground bearing capacity.
The minimum required spreader plate surface area is calculated using the formula: Area (m²) = Maximum Outrigger Point Load (kN) / Allowable Ground Bearing Capacity (kN/m²).
Use purpose-made spreader pads rated for the load, such as engineered polymer or suitable hardwood mats; never improvise with scaffold boards, bricks, blocks or pallets.
Pad thickness and bending stiffness are vital; an insufficiently rigid pad will bend under the outrigger foot, concentrating point loading in the centre and defeating the load-spreading mechanism.
Where the manufacturer requires it, as on most vehicle-mounted platforms, outriggers are extended until the road wheels are clear of the ground, and the chassis is levelled within the manufacturer's tolerance.
Last updated: October 2026
Spreader Plates, Outrigger Mats & Setup
Quick Answer: The steel foot (shoe) on an outrigger is rarely large enough to spread its load safely onto natural ground or paving. Spreader plates (outrigger pads) enlarge the contact area so the applied pressure stays below the ground's allowable bearing pressure ( q allowable q_{\text{allowable}} q allowable ). Size them with Area ( m 2 ) = Outrigger Point Load ( k N ) Ground Bearing Capacity ( k N / m 2 ) \text{Area } (m^2) = \frac{\text{Outrigger Point Load } (kN)}{\text{Ground Bearing Capacity } (kN/m^2)} Area ( m 2 ) = Ground Bearing Capacity ( k N / m 2 ) Outrigger Point Load ( k N ) , use purpose-made pads rated for the load, centre the foot on the pad, and set the outriggers as the manufacturer instructs (on most vehicle mounts, until the wheels are clear of the ground).
Proper outrigger setup is the single most critical procedural defence against MEWP overturns. A failure to size, position, or level outrigger pads correctly can cause rapid structural instability, resulting in catastrophic loss of life and equipment destruction.
Purpose & Physics of Spreader Plates
A standard manufacturer-fitted outrigger shoe typically has a diameter or side length of 200 mm to 350 mm, providing a contact area of merely 0.03 m 2 0.03\text{ m}^2 0.03 m 2 to 0.09 m 2 0.09\text{ m}^2 0.09 m 2 . When a 60 kN outrigger load is transferred through an unaugmented 300 mm diameter shoe ( A ≈ 0.071 m 2 A \approx 0.071\text{ m}^2 A ≈ 0.071 m 2 ), the ground pressure exerted is:
P = F A = 60 kN 0.071 m 2 ≈ 845 kN/m 2 P = \frac{F}{A} = \frac{60\text{ kN}}{0.071\text{ m}^2} \approx 845\text{ kN/m}^2 P = A F = 0.071 m 2 60 kN ≈ 845 kN/m 2
As established in Section 7.1, very few soils on construction sites—with the exception of solid bedrock—can withstand 845 kN/m 2 845\text{ kN/m}^2 845 kN/m 2 . On typical firm ground ( 100 kN/m 2 100\text{ kN/m}^2 100 kN/m 2 ), this unaugmented shoe will punch straight through the surface.
Spreader plates (also termed outrigger pads or mats ) bridge this mechanical divide. By introducing a rigid, wide-area pad between the metal outrigger shoe and the ground, the concentrated point load is dispersed across a much larger surface area, driving the applied pressure below the ground's allowable bearing threshold.
The Sizing Formula & Worked Engineering Calculation
To determine the minimum surface area required for an outrigger spreader plate, operators and planners use the basic pressure equation (IPAF's online Spreader Pad Calculator applies the same principle):
Required Area A (m 2 ) = Maximum Outrigger Point Load P max (kN) Allowable Ground Bearing Capacity q allowable (kN/m 2 ) \text{Required Area } A\text{ (m}^2\text{)} = \frac{\text{Maximum Outrigger Point Load } P_{\max}\text{ (kN)}}{\text{Allowable Ground Bearing Capacity } q_{\text{allowable}}\text{ (kN/m}^2\text{)}} Required Area A (m 2 ) = Allowable Ground Bearing Capacity q allowable (kN/m 2 ) Maximum Outrigger Point Load P m a x (kN)
Once the required surface area ( A A A ) is calculated, the physical dimensions of the pad are derived based on pad geometry:
- Square Spreader Plate : Side length L = A L = \sqrt{A} L = A
- Circular Spreader Plate : Diameter D = 4 A π D = \sqrt{\frac{4A}{\pi}} D = π 4 A
- Step-by-Step Worked Sizing Example
An operator must set up a Category 1b truck-mounted boom on an unpaved grass verge adjacent to a commercial building.
Step 1: Identify Maximum Outrigger Point Load ( P max P_{\max} P m a x ) Consult the manufacturer's specification decal or operator handbook. For this 7,500 kg gross weight unit, the maximum calculated corner outrigger point load under full outreach and payload is specified as 65 kN 65\text{ kN} 65 kN (~6.6 tonnes force).
Step 2: Determine Allowable Ground Bearing Capacity ( q allowable q_{\text{allowable}} q allowable ) The site ground assessment confirms the subsoil is firm, naturally consolidated cohesive clay with an allowable bearing capacity of 100 kN/m 2 100\text{ kN/m}^2 100 kN/m 2 (~10 t/m²).
Step 3: Calculate Minimum Required Pad Area ( A A A ) A = P max q allowable = 65 kN 100 kN/m 2 = 0.65 m 2 A = \frac{P_{\max}}{q_{\text{allowable}}} = \frac{65\text{ kN}}{100\text{ kN/m}^2} = 0.65\text{ m}^2 A = q allowable P m a x = 100 kN/m 2 65 kN = 0.65 m 2
Step 4: Determine Pad Dimensions For a square spreader plate: L = 0.65 m 2 ≈ 0.806 m = 806 mm L = \sqrt{0.65\text{ m}^2} \approx 0.806\text{ m} = 806\text{ mm} L = 0.65 m 2 ≈ 0.806 m = 806 mm
Step 5: Select Commercial Spreader Plate Always round up to the next commercially available size. In this scenario, standard 800 mm × 800 mm 800\text{ mm} \times 800\text{ mm} 800 mm × 800 mm ( 0.64 m 2 0.64\text{ m}^2 0.64 m 2 ) pads are slightly undersized; the operator must select 900 mm × 900 mm 900\text{ mm} \times 900\text{ mm} 900 mm × 900 mm ( 0.81 m 2 0.81\text{ m}^2 0.81 m 2 ) or 1 , 000 mm × 1 , 000 mm 1,000\text{ mm} \times 1,000\text{ mm} 1 , 000 mm × 1 , 000 mm ( 1.0 m 2 1.0\text{ m}^2 1.0 m 2 ) spreader mats.
Actual Applied Pressure with 900 mm Pad = 65 kN 0.81 m 2 = 80.2 kN/m 2 \text{Actual Applied Pressure with } 900\text{ mm Pad} = \frac{65\text{ kN}}{0.81\text{ m}^2} = 80.2\text{ kN/m}^2 Actual Applied Pressure with 900 mm Pad = 0.81 m 2 65 kN = 80.2 kN/m 2
Because 80.2 kN/m 2 < 100 kN/m 2 80.2\text{ kN/m}^2 < 100\text{ kN/m}^2 80.2 kN/m 2 < 100 kN/m 2 , the ground will safely support the machine without shear failure or excessive settlement.
Spreader Mat Materials: Approved vs. Prohibited
The material composition of an outrigger pad dictates its ability to transmit bending moments and resist punching shear.
Approved Spreader Mat Materials
High-Density Polyethylene (HDPE) / UHMW Composite Mats :
Modern engineered plastic mats are the industry benchmark for powered access operations.
Manufactured from ultra-high-molecular-weight polyethylene, they are virtually unbreakable, impervious to water, oil, and chemicals, and will not rot, crack, or splinter.
They maintain consistent flexural modulus across extreme temperature ranges (-40°C to +80°C) and feature integrated carrying handles.
Engineered Hardwood Timber Mats / Sleepers :
Seasoned dense hardwoods such as Oak , Ekki , or Greenheart provide exceptional compressive strength perpendicular to the grain.
Hardwood timbers must be structurally sound, free from rot, splits, or insect infestation, and bolted together with steel tie rods into a unified load-distributing mat.
Materials Not to Use
Industry guidance and site rules are clear that improvised packing must not be used under outriggers. Never use:
Softwood Timber Scaffold Boards : Scaffold boards are manufactured from European whitewood/redwood designed for distributed pedestrian loads in tension and bending. Under high concentrated compressive point loads, softwood crushes, splits along the grain, and snaps instantly.
Cinder Blocks, Bricks & Concrete Masonry : Concrete blocks and building bricks possess high compressive strength only when uniformly loaded across an entire wall mortar bed. Under a localised outrigger point load, masonry fractures brittly and shatters into rubble.
Wooden Pallets & Timber Offcuts : Slatted wooden shipping pallets contain huge internal voids. Placing an outrigger jack on a pallet results in instantaneous collapse as the thin pine slats snap.
Plywood Sheets & OSB Offcuts : Thin sheets of standard shuttering plywood or oriented strand board (OSB) delaminate rapidly when wet and lack the flexural stiffness required to spread heavy point loads.
Spreader Mat Material Comparison
Material Mechanical Integrity Water & Rot Resistance Suitability for MEWP Outriggers
Engineered HDPE Composite Superior flexural rigidity; high yield strength 100% impervious; zero water absorption Approved : Industry standard for all MEWP categories
Bolted Hardwood (Oak / Ekki) High compressive strength; excellent rigidity Good if seasoned; subject to weathering Approved : Suitable when bolted into solid mats
Softwood Scaffold Planks Brittle in shear; splits easily along grain Prone to rot, warping, and moisture degradation PROHIBITED : Fails under concentrated point loads
Hollow / Solid Concrete Blocks Brittle; zero tensile/bending resistance Degrades in freeze-thaw cycles PROHIBITED : Catastrophic brittle fracture risk
Wooden Shipping Pallets Unrated pine slats over large hollow voids Poor; rots and splinters rapidly PROHIBITED : Immediate structural collapse
Warning
Never use softwood timber scaffold boards, concrete building blocks, or pallets as outrigger packing. After an overturn, improvised packing is clear evidence that the set-up was not planned to a safe standard.
Pad Thickness, Stiffness & Cantilever Point Loading
A common and dangerous misconception among untrained operators is that simply placing any thin plate under an outrigger foot guarantees safe load distribution. In reality, pad thickness and bending stiffness are just as critical as surface area. INCORRECT (THIN / FLEXIBLE MAT) CORRECT (RIGID / THICK MAT)
- Outrigger Shoe Outrigger Shoe
- │ │ │ │
- ▼ ▼ ▼ ▼
- ┌──────────────┐ ┌──────────────┐
- ══╡ ╞══ ████████████████████
- ╱ └──────────────┘ ╲ ████████████████████
- ╱ ▲ ▲ ╲ │ │
- ▼ ─┴──────────────┴─ ▼ ▼ ▼
- Edges Curl Up; Point Load Concentrated Uniform 45° Stress Dispersion Across
- Directly Under Centre Shoe Entire Ground Area
- The Bending Mechanism (Cantilever Deflection)
When an outrigger shoe pushes down into the centre of a wide spreader plate, the ground pushes back upward against the outer edges of the plate. This creates a severe bending moment (cantilever flexure) acting from the edge of the steel shoe to the outer perimeter of the pad.
If the pad is too thin or flexible , it deflects elastically. The outer edges of the pad bend upward, losing contact with the ground entirely. As a result, the entire 60 kN load remains concentrated in the exact centre beneath the shoe, completely defeating the purpose of the spreader plate.
If the pad is sufficiently thick and rigid , the load disperses outward through the material at approximately a 45° angle of distribution , transferring uniform compressive stress across the entire bottom surface of the pad.
Rules for Pad Thickness & Centreing
Rated Pads Only : Use pads that their manufacturer rates for the outrigger load and pad size. Thin or flexible sheets bend under the foot and concentrate the load in the centre, so thickness and stiffness matter as much as area.
Centreing the Shoe : The outrigger foot must always be positioned dead-centre on the spreader plate. Placing an outrigger shoe near the edge of a pad creates extreme eccentric loading, causing the pad to tilt, gouge into the subsoil, and flip upward, leading to an immediate machine tilt.
Full Extension Interlocks & Setup Sequence
Modern Mobile Elevating Work Platforms incorporate sophisticated electrical and hydraulic safety interlocks governed by BS EN 280 to prevent unsafe operation.
Outrigger Beam Extension Interlocks
Many Category 1b machines feature variable outrigger configurations (e.g., full extension, partial extension, or narrow jacking). Each outrigger beam is fitted with internal microswitches or linear transducers that continuously monitor horizontal extension. If an outrigger beam is not fully extended to its locked detent—or if the control system has not been programmed for a narrow-jacking envelope—the electrical safety circuit isolates the boom lift hydraulics, preventing boom elevation from the stowed position.
Wheel Clearance & Suspension Isolation (Category 1b)
For many static boom platforms (truck mounts, trailer mounts and spider lifts), the manufacturer's set-up procedure lifts the wheels or tracks clear of the ground so that tyres and suspension are not part of the support.
Important
Tyres Off the Ground Where Required: On most vehicle-mounted MEWPs, the manufacturer requires all road wheels to be raised clear of the ground. Leaving tyres in contact puts the vehicle's springs and tyre walls in the load path, so the platform can bounce and roll as the boom moves. Always follow the set-up instructions for that machine.
Hydraulic Pilot Check Valves (Counterbalance Valves)
Every outrigger hydraulic jack cylinder is fitted with an integral, steel-bodied pilot-operated check valve (counterbalance valve) flanged directly to the cylinder port. If a high-pressure hydraulic supply hose bursts or leaks while the platform is elevated, the check valve locks the hydraulic oil inside the cylinder, preventing the jack leg from collapsing.
Levelling Verification: Bullseye Spirit Level & Digital Displays
A MEWP elevated on an unlevel chassis experiences severe eccentric side-loading on its boom structure and slews unevenly, massively increasing the risk of structural failure and tipping.
Tolerance Limits
Outrigger-supported machines (Categories 1a and 1b) typically have an extremely strict allowable levelling tolerance—usually less than 1° (often 0.5°) from true horizontal.
Wheeled self-propelled machines (Categories 3a and 3b) typically allow from about 1.5° (slab scissors, side to side) up to 5° (rough-terrain booms) before the tilt alarm cuts out functions.
Levelling Instrumentation
Bullseye Spirit Level (Circular Bubble) : Mounted directly on the chassis frame. The bubble must be adjusted until it rests precisely within the central target circle. When viewing a bullseye level, the operator must look directly from above to eliminate parallax viewing error.
Electronic Digital Level Displays : High-specification truck mounts and spider lifts feature electronic dual-axis inclinometers that display precise pitch and roll angles in degrees on the ground control console. Automatic outrigger auto-level systems can deploy and level the chassis at the touch of a button, but the operator must manually verify pad contact and ground integrity.
Step-by-Step Levelling Protocol Step 1: Conduct Ground Survey & Position Rated Spreader Pads Beneath All Outriggers
- Step 2: Lower Outriggers in the Sequence the Manufacturer Specifies
- Step 3: Keep Each Outrigger Foot Centred on Its Pad
- Step 4: Extend Until the Wheels Are Clear of the Ground Where the Manual Requires
- Step 5: Adjust to Centre the Level Indicator Within the Manufacturer's Tolerance
- Step 6: Visually Verify All Pads Bear Solid Ground Contact with No Voids
- Step 7: Confirm Interlock Status Indicators Before Operating the Boom