Study guide

7.4 Cranes, Structures & Supporting Equipment

LEEA Foundation Certificate Lifting Equipment Engineers Association, UK

Track your progress as you read

Finished sections get a check mark.

1 Introduction & Exam Overview

About the LEEA Foundation Certificate The LEEA Qualification Pathway, Diplomas & the TEAM Card

2 Legislation, Standards & Regulatory Framework

1.1 Health and Safety at Work etc. Act 1974 & Management Regulations 1.2 Provision and Use of Work Equipment Regulations 1998 (PUWER 1998) 1.3 Lifting Operations and Lifting Equipment Regulations 1998 (LOLER 1998) 1.4 Standards, Marking & Documentation 1.5 Controlling Risks, Hazard Management & the 5-Step Risk Assessment

3 Principles of Mechanics & Material Properties

2.1 Forces, Mass, Weight & Center of Gravity 2.2 Mechanical Properties: Stress, Strain & Safety Factors 2.3 WLL, SWL & Rating Concepts 2.4 Heat Treatment & Metallurgy in Lifting Equipment 2.5 Units of Measure, Symbols & Conversions 2.6 Basic Machines, Mechanical Advantage, Velocity Ratio & Efficiency 2.7 Verification, Test Machines, Calibration & NDT Methods

4 Shackles, Eyebolts & Threaded Fittings

3.1 Shackles: Types, Standards & Rating 3.2 Shackle Inspection, Safe Use & Rejection Criteria 3.3 Eyebolts & Eyenuts: Types & Angular Loading 3.4 Eyebolt Installation, Inspection & Rejection Criteria 3.5 Rigging Screws & Turnbuckles

5 Chain Slings & Components

4.1 Chain Sling Construction & Grades 4.2 Chain Components: Master Links, Hooks & Couplers 4.3 Chain Sling Marking, Certification & Safe Use 4.4 Chain Sling Inspection, Wear & Rejection Criteria

6 Wire Rope Slings & Terminations

5.1 Wire Rope Construction & Cores 5.2 Wire Rope Terminations & Assemblies 5.3 Wire Rope Sling Ratings & Safe Use 5.4 Wire Rope Sling Inspection & Discard Criteria

7 Textile Slings & Below-the-Hook Accessories

6.1 Flat Woven Webbing Slings 6.2 Roundslings & High-Performance Fiber Slings 6.3 Textile Sling Inspection, Chemical & Mechanical Damage 6.4 Plate Clamps, Beam Clamps & Below-the-Hook Lifters 6.5 Fibre Rope Slings & Natural Fibre Ropes 6.6 Crane Forks & C-Hooks

8 Manual & Powered Lifting Appliances

7.1 Manual Chain Blocks & Lever Hoists 7.2 Wire Rope Pull-Lifts, Winches & Jacks 7.3 Powered Hoists: Electric & Pneumatic 7.4 Cranes, Structures & Supporting Equipment 7.5 Mobile Cranes, Tower Cranes & Offshore Cranes 7.6 Offshore Containers, Pad Eyes & Lifting Sets

9 Rigging Calculations, Mode Factors & Complex Lifts

8.1 Uniform Load Method (ULM) for Multi-Leg Slings 8.2 Trigonometric Method for Multi-Leg Slings 8.3 Hitch Mode Factors: Choked, Basket & Wrap Hitches 8.4 Center of Gravity Off-Center & Asymmetric Load Calculations

7.4 Cranes, Structures & Supporting Equipment

Key Takeaways Explain This Topic AI

A crane system includes the hoist, bridge or jib, end carriages, trolley, tracks, runway or supporting structure, power feed, controls, foundations and connection details.

Top-running, under-slung, portal, semi-portal, jib, monorail and mobile gantry arrangements impose different loads and clearances on their supporting structures.

Deflection limits depend on the applicable crane or structural standard, crane class, span, load case and manufacturer design; L/500 is not a universal LOLER limit for every bridge or runway.

LOLER does not mandate one proof-load factor or routine NDT at every periodic examination; the competent person decides necessary testing using the design, standard, manufacturer information and risk.

Pre-use and interim checks focus on controls, brakes, limits, ropes or chains, hooks, tracks and obvious damage; thorough examination addresses the safety-critical system at the interval or scheme in force.

Last updated: August 2026

Cranes, Structures and Supporting Equipment

A crane is not just the hook and hoist. Its load travels through the lifting medium, drum or pocket wheel, trolley, bridge or jib, end carriages, rails, runway beams, connections, columns and foundations. Every element in that path must suit the rated load, dynamic effects and operating environment.

Common Arrangements

Arrangement Distinguishing feature Key selection concern

Top-running bridge crane End carriages run on rails above the supporting runways Building loads, rail alignment, access and clearances

Under-slung bridge crane Bridge runs from the lower flanges of tracks Flange loading, suspension details and end approach

Portal or gantry crane Bridge is supported on legs running on low-level tracks Ground-level travel path, rail and foundation condition

  • Semi-portal crane One side is elevated and one side leg-supported Unequal support systems and alignment
  • Monorail Hoist trolley follows one runway Curves, switches, transfer points and end stops

Slewing jib Cantilever arm rotates about a wall or pillar support Effective radius, overturning moment and foundation

  • Mobile gantry Freestanding frame can be repositioned Floor capacity, wheel locks, erection and movement rules
  • Crane Motions

A bridge crane may have hoisting, cross-travel and long-travel motions. Controls must identify direction clearly from the operator's viewpoint. Travel paths, hook paths and end approaches must remain clear, and end stops or anti-collision devices are final protections rather than normal brakes.

Supporting Structures and Load Paths

The rated payload is only part of the imposed load. Design and selection also consider:

  • self-weight of hoist, trolley, bridge and accessories;
  • acceleration, braking and skew forces;
  • impact or hoisting dynamic factors;
  • side loads, wind and outdoor exposure;
  • wheel loads and their spacing;
  • fatigue class and expected operating cycles;
  • foundation bearing and anchor forces; and

maintenance access and rescue arrangements.

For a pillar jib, the overturning effect grows with load × radius . A 2 t load at 5 m creates twice the payload moment of the same load at 2.5 m, before self-weight and dynamic effects. That is why the jib, column, base plate, anchors and concrete foundation form one engineered system.

Trolleys, Clamps and Tracks

A trolley must match the beam flange width and profile and be adjusted with the clearances required by its instructions. Anti-drop features reduce the consequence of wheel or axle failure, while end stops prevent travel off an open runway. A temporary beam clamp also depends on the suitability of the beam and correct installation; most clamps permit in-line loading only unless the manufacturer states otherwise.

Runway switches, turntables and transfer bridges must be fully aligned and locked before a trolley crosses. A small step or gap can shock-load the wheel and supporting structure.

Deflection Is Design-Specific

Excessive deflection can cause trolley drift, alignment problems, poor load positioning and fatigue. Designers therefore control stiffness as well as strength. However, LOLER does not prescribe a universal L/500 limit . Different crane and runway standards, classes, load combinations and owner specifications can set different criteria.

A calculation question is valid only when it supplies the governing limit. If a design specification states L/500 for a 12,000 mm span, the permitted deflection is:

12,000 / 500 = 24 mm.

That arithmetic does not prove that L/500 governs another crane. The competent engineer must identify the applicable standard and design data first.

Commissioning, Examination and Testing

Lifting equipment normally needs thorough examination before first use unless the Declaration-of-Conformity exception applies. Equipment whose safety depends on installation or assembly must be examined after installation and before use at that location.

Testing Boundary

HSE states that most lifting equipment does not need routine testing as part of every thorough examination and that overload testing can itself cause damage. Testing may be appropriate for manufacturer verification, installation, major alteration, repair, exceptional circumstances, or where the competent person needs it to support an examination.

The test load and method come from the applicable product or crane standard, manufacturer information, design and competent-person plan. Figures such as 1.25 static or 1.1 dynamic occur in particular contexts, but they are not universal LOLER factors. Never choose a test mass from memory.

Examination Scope

A competent-person examination may address:

  • structure, welds, bolted joints, rails and anchors;
  • hooks, ropes, chains, drums, sheaves and terminations;
  • brakes, controls, emergency stops, limits and overload protection;
  • trolleys, end carriages, wheels, buffers and anti-collision systems;
  • electrical, hydraulic or pneumatic safety functions; and

markings, reports, maintenance history and outstanding defects.

NDT is used where visual examination, history, deterioration mechanism or the examination scheme justifies it. It is not mandatory on every weld at every annual examination.

Safe Operating Check

Before a lift, the operator checks the condition and function within their training: controls and direction, brakes, hook and latch, rope or chain, visible track, travel path, limits where required, and warning devices. Make a trial lift just clear, confirm balance and brake holding, then travel smoothly without dragging, side pulling or driving into end stops.

The lowest safe capacity in the complete configuration governs. A 5 t hoist on a 3.2 t runway is a 3.2 t system, subject to any further configuration or environmental derating.