About the LEEA Foundation Certificate The LEEA Qualification Pathway, Diplomas & the TEAM Card
2 Legislation, Standards & Regulatory Framework
1.1 Health and Safety at Work etc. Act 1974 & Management Regulations 1.2 Provision and Use of Work Equipment Regulations 1998 (PUWER 1998) 1.3 Lifting Operations and Lifting Equipment Regulations 1998 (LOLER 1998) 1.4 Standards, Marking & Documentation 1.5 Controlling Risks, Hazard Management & the 5-Step Risk Assessment
3 Principles of Mechanics & Material Properties
2.1 Forces, Mass, Weight & Center of Gravity 2.2 Mechanical Properties: Stress, Strain & Safety Factors 2.3 WLL, SWL & Rating Concepts 2.4 Heat Treatment & Metallurgy in Lifting Equipment 2.5 Units of Measure, Symbols & Conversions 2.6 Basic Machines, Mechanical Advantage, Velocity Ratio & Efficiency 2.7 Verification, Test Machines, Calibration & NDT Methods
4 Shackles, Eyebolts & Threaded Fittings
3.1 Shackles: Types, Standards & Rating 3.2 Shackle Inspection, Safe Use & Rejection Criteria 3.3 Eyebolts & Eyenuts: Types & Angular Loading 3.4 Eyebolt Installation, Inspection & Rejection Criteria 3.5 Rigging Screws & Turnbuckles
5 Chain Slings & Components
4.1 Chain Sling Construction & Grades 4.2 Chain Components: Master Links, Hooks & Couplers 4.3 Chain Sling Marking, Certification & Safe Use 4.4 Chain Sling Inspection, Wear & Rejection Criteria
6 Wire Rope Slings & Terminations
5.1 Wire Rope Construction & Cores 5.2 Wire Rope Terminations & Assemblies 5.3 Wire Rope Sling Ratings & Safe Use 5.4 Wire Rope Sling Inspection & Discard Criteria
7 Textile Slings & Below-the-Hook Accessories
6.1 Flat Woven Webbing Slings 6.2 Roundslings & High-Performance Fiber Slings 6.3 Textile Sling Inspection, Chemical & Mechanical Damage 6.4 Plate Clamps, Beam Clamps & Below-the-Hook Lifters 6.5 Fibre Rope Slings & Natural Fibre Ropes 6.6 Crane Forks & C-Hooks
8 Manual & Powered Lifting Appliances
7.1 Manual Chain Blocks & Lever Hoists 7.2 Wire Rope Pull-Lifts, Winches & Jacks 7.3 Powered Hoists: Electric & Pneumatic 7.4 Cranes, Structures & Supporting Equipment 7.5 Mobile Cranes, Tower Cranes & Offshore Cranes 7.6 Offshore Containers, Pad Eyes & Lifting Sets
9 Rigging Calculations, Mode Factors & Complex Lifts
8.1 Uniform Load Method (ULM) for Multi-Leg Slings 8.2 Trigonometric Method for Multi-Leg Slings 8.3 Hitch Mode Factors: Choked, Basket & Wrap Hitches 8.4 Center of Gravity Off-Center & Asymmetric Load Calculations
8.4 Center of Gravity Off-Center & Asymmetric Load Calculations
Key Takeaways Explain This Topic AI
When the Center of Gravity (CG) of a load is off-center, the weight is distributed unequally between sling legs, with the leg closest to the CG carrying the majority of the load according to W_A = W * (d_B / (d_A + d_B)).
For an asymmetric load lifted by a 2-leg sling from a single crane hook, the hook will naturally align directly above the CG, causing the sling legs to assume unequal angles to the vertical and unequal tension forces.
In multi-leg slings (3-leg or 4-leg) on asymmetric loads, rigging calculations must ensure that no single leg exceeds its individual rated Working Load Limit, often requiring leg tension to be calculated as if 2 legs carry the entire load weight.
Adjusting sling leg lengths using chain shorteners or turnbuckles allows the hook to be positioned directly above the off-center CG while keeping the load level, avoiding dangerous load tilting.
In 2-crane tailing operations (turning or upending heavy vessels), load sharing dynamically shifts between the main crane and tailing crane as the tilt angle changes, requiring continuous monitoring of both hook loads throughout the turn.
Last updated: August 2026
In real-world industrial rigging, loads are rarely perfectly symmetrical or uniformly dense. Heavy internal components—such as electric motors, gearboxes, refractory linings, or liquid pockets—shift the Center of Gravity (CG) away from the geometric center of the object. Lifting an asymmetric load without calculating off-center CG distribution leads to severe load tilting, unequal sling leg tension, unexpected load swings, and potential rigging failure.
Physics of Center of Gravity (CG) and Center of Lift (CL)
The Center of Gravity (CG) is the theoretical point through which the entire weight of a body acts in three-dimensional space. The Center of Lift (CL) is the point in space located directly below the crane hook apex where the sling forces converge.
The Fundamental Law of Static Suspension
LAW OF SUSPENSION: When any body is suspended freely from a single crane hook, it will automatically rotate and tilt until its Center of Gravity sits on a vertical line running directly beneath the crane hook .
If the pick points are placed symmetrically around the geometric center of an asymmetric load, the heavier end will sink and the lighter end will rise until the CG aligns vertically under the hook. This rotation causes the sling leg attached to the heavy end to become much steeper, drastically increasing tension in that leg while the light-end leg goes slack.
2-Point Load Sharing Formula (Static Equilibrium)
To calculate how total load weight ( W W W ) is shared between two lifting points (Point A and Point B) when the Center of Gravity is off-center, we apply static moment equilibrium about each pick point.
Let:
W = Total gross load weight W = \text{Total gross load weight} W = Total gross load weight
L = d A + d B = Total horizontal distance between Pick Points A and B L = d_A + d_B = \text{Total horizontal distance between Pick Points A and B} L = d A + d B = Total horizontal distance between Pick Points A and B
d A = Horizontal distance from Pick Point A to the Center of Gravity d_A = \text{Horizontal distance from Pick Point A to the Center of Gravity} d A = Horizontal distance from Pick Point A to the Center of Gravity
d B = Horizontal distance from Pick Point B to the Center of Gravity d_B = \text{Horizontal distance from Pick Point B to the Center of Gravity} d B = Horizontal distance from Pick Point B to the Center of Gravity
W A = Vertical load share carried by Pick Point A W_A = \text{Vertical load share carried by Pick Point A} W A = Vertical load share carried by Pick Point A
W B = Vertical load share carried by Pick Point B W_B = \text{Vertical load share carried by Pick Point B} W B = Vertical load share carried by Pick Point B
Derivation from Moment Equilibrium
Taking moments about Pick Point B ( ∑ M B = 0 \sum M_B = 0 ∑ M B = 0 ): W A ⋅ ( d A + d B ) − W ⋅ d B = 0 ⟹ W A = W ⋅ ( d B d A + d B ) W_A \cdot (d_A + d_B) - W \cdot d_B = 0 \implies W_A = W \cdot \left(\frac{d_B}{d_A + d_B}\right) W A ⋅ ( d A + d B ) − W ⋅ d B = 0 ⟹ W A = W ⋅ ( d A + d B d B )
Taking moments about Pick Point A ( ∑ M A = 0 \sum M_A = 0 ∑ M A = 0 ): W B = W ⋅ ( d A d A + d B ) W_B = W \cdot \left(\frac{d_A}{d_A + d_B}\right) W B = W ⋅ ( d A + d B d A )
Key Principle of Asymmetric Distribution
Notice the inverse horizontal relationship: The pick point closest to the Center of Gravity carries the larger share of the weight. As d A → 0 d_A \to 0 d A → 0 , W A → W W_A \to W W A → W .
Calculating Leg Tension for Off-Center CG
Once the vertical load shares ( W A W_A W A and W B W_B W B ) are determined, the actual tension in each sling leg ( T A T_A T A and T B T_B T B ) must be calculated by incorporating the sling leg angles ( θ A \theta_A θ A and θ B \theta_B θ B measured to the vertical): T A = W A cos θ A = W ⋅ d B ( d A + d B ) ⋅ cos θ A T_A = \frac{W_A}{\cos\theta_A} = \frac{W \cdot d_B}{(d_A + d_B) \cdot \cos\theta_A} T A = cos θ A W A = ( d A + d B ) ⋅ cos θ A W ⋅ d B T B = W B cos θ B = W ⋅ d A ( d A + d B ) ⋅ cos θ B T_B = \frac{W_B}{\cos\theta_B} = \frac{W \cdot d_A}{(d_A + d_B) \cdot \cos\theta_B} T B = cos θ B W B = ( d A + d B ) ⋅ cos θ B W ⋅ d A
Engineering Methods for Managing Asymmetric Lifts
When handling asymmetric loads, riggers employ three standard engineering solutions:
1. Adjusting Sling Leg Lengths (Leg Shorteners / Turnbuckles)
To keep an asymmetric load perfectly level during lifting, the crane hook must be positioned directly above the CG before hoisting. Because the CG is closer to Point A than Point B, the distance from Point A to the hook is shorter than from Point B to the hook. Riggers use chain shortening clutches or turnbuckles to shorten Leg A and lengthen Leg B. This aligns the hook over the CG while holding the load structure perfectly horizontal.
2. De-rating Sling Assemblies or Selecting Asymmetric Capacities
If equal-length sling legs are used and the load is allowed to tilt, or if a multi-leg (3 or 4 leg) sling is used on an asymmetric load, the load distribution must be assumed non-uniform. Standard LEEA practice mandates:
Calculate maximum tension in the heavily loaded leg.
Select a sling size where each individual leg WLL is capable of supporting the maximum tension ( T m a x T_{max} T ma x ) , effectively ignoring assistance from lighter legs.
3. Multi-Leg (3 & 4 Leg) Asymmetric Rule
For 3-leg and 4-leg slings on asymmetric loads, statics shows that two legs closest to the CG may carry up to 80% to 100% of the entire load weight . The rigger must evaluate load distribution in two orthogonal planes ( X X X and Y Y Y axes) to calculate individual leg loads.
Tailing Lifts with Two Cranes (Upending Operations)
A tailing lift is a complex, high-risk operation where two cranes (a Main Crane and a Tailing Crane) work in tandem to tilt or upend a heavy vessel, column, or vessel from a horizontal orientation to vertical (or vice-versa).
Dynamic Load Distribution during Tilting
As the vessel transitions from horizontal ( 0 ∘ 0^\circ 0 ∘ ) to vertical ( 90 ∘ 90^\circ 9 0 ∘ ), the distribution of load weight between the Main Crane ( W m a i n W_{main} W main ) and Tailing Crane ( W t a i l W_{tail} W t ai l ) shifts dynamically as a function of tilt angle ( ϕ \phi ϕ ):
Horizontal Position ( ϕ = 0 ∘ \phi = 0^\circ ϕ = 0 ∘ ): Static 2-point load sharing applies based on CG distance: W m a i n = W ⋅ ( d t a i l L ) , W t a i l = W ⋅ ( d h e a d L ) W_{main} = W \cdot \left(\frac{d_{tail}}{L}\right), \quad W_{tail} = W \cdot \left(\frac{d_{head}}{L}\right) W main = W ⋅ ( L d t ai l ) , W t ai l = W ⋅ ( L d h e a d )
Tilting Transition ( 0 ∘ < ϕ < 90 ∘ 0^\circ < \phi < 90^\circ 0 ∘ < ϕ < 9 0 ∘ ): As the Main Crane lifts the head lug upward, the Center of Gravity shifts horizontally toward the main head lug. The load share on the tailing crane steadily decreases while the load share on the main crane increases.
Vertical Position ( ϕ = 90 ∘ \phi = 90^\circ ϕ = 9 0 ∘ ): When the vessel reaches true vertical, the Center of Gravity is suspended directly beneath the Main Crane hook. W m a i n = 100 % of Total Weight W , W t a i l = 0 W_{main} = 100\% \text{ of Total Weight } W, \quad W_{tail} = 0 W main = 100% of Total Weight W , W t ai l = 0
CRITICAL TAILING SAFETY: Riggers and crane operators must continuously monitor load indicator displays during upending. The main crane must be rated for 100 % 100\% 100% of the gross vessel weight, while the tailing crane and tailing lug must be rated for the maximum horizontal load share plus impact factors. Swivel hoist rings or trunnions must be used to prevent side-loading crane blocks during rotation.
- Step-by-Step Worked Engineering Examples
- Worked Example 1: Asymmetric Load Sharing & Leg Tension
Problem: A skid containing a heavy compressor motor has a total mass of 12.0 tonnes 12.0\text{ tonnes} 12.0 tonnes and a total length of 6.0 metres 6.0\text{ metres} 6.0 metres . The Center of Gravity is located 1.8 metres 1.8\text{ metres} 1.8 metres from Pick Point A and 4.2 metres 4.2\text{ metres} 4.2 metres from Pick Point B. The load is lifted using a 2-leg chain sling with legs adjusted so that each leg forms an angle of 30 ∘ 30^\circ 3 0 ∘ to the vertical while keeping the skid level. Calculate:
Vertical load share at Pick Point A ( W A W_A W A ) and Pick Point B ( W B W_B W B ).
Actual leg tension in Leg A ( T A T_A T A ) and Leg B ( T B T_B T B ).
Solution:
Calculate Vertical Load Shares: L = d A + d B = 1.8 m + 4.2 m = 6.0 metres L = d_A + d_B = 1.8\text{ m} + 4.2\text{ m} = 6.0\text{ metres} L = d A + d B = 1.8 m + 4.2 m = 6.0 metres W A = W ⋅ ( d B L ) = 12.0 t × ( 4.2 6.0 ) = 12.0 × 0.70 = 8.40 tonnes W_A = W \cdot \left(\frac{d_B}{L}\right) = 12.0\text{ t} \times \left(\frac{4.2}{6.0}\right) = 12.0 \times 0.70 = 8.40\text{ tonnes} W A = W ⋅ ( L d B ) = 12.0 t × ( 6.0 4.2 ) = 12.0 × 0.70 = 8.40 tonnes W B = W ⋅ ( d A L ) = 12.0 t × ( 1.8 6.0 ) = 12.0 × 0.30 = 3.60 tonnes W_B = W \cdot \left(\frac{d_A}{L}\right) = 12.0\text{ t} \times \left(\frac{1.8}{6.0}\right) = 12.0 \times 0.30 = 3.60\text{ tonnes} W B = W ⋅ ( L d A ) = 12.0 t × ( 6.0 1.8 ) = 12.0 × 0.30 = 3.60 tonnes
Check: W A + W B = 8.40 + 3.60 = 12.00 tonnes W_A + W_B = 8.40 + 3.60 = 12.00\text{ tonnes} W A + W B = 8.40 + 3.60 = 12.00 tonnes .
Calculate Sling Leg Tensions ( θ = 30 ∘ , cos ( 30 ∘ ) = 0.8660 \theta = 30^\circ, \cos(30^\circ) = 0.8660 θ = 3 0 ∘ , cos ( 3 0 ∘ ) = 0.8660 ): T A = W A cos ( 30 ∘ ) = 8.40 t 0.8660 = 9.6998 ≈ 9.70 tonnes T_A = \frac{W_A}{\cos(30^\circ)} = \frac{8.40\text{ t}}{0.8660} = 9.6998 \approx 9.70\text{ tonnes} T A = cos ( 3 0 ∘ ) W A = 0.8660 8.40 t = 9.6998 ≈ 9.70 tonnes T B = W B cos ( 30 ∘ ) = 3.60 t 0.8660 = 4.1570 ≈ 4.16 tonnes T_B = \frac{W_B}{\cos(30^\circ)} = \frac{3.60\text{ t}}{0.8660} = 4.1570 \approx 4.16\text{ tonnes} T B = cos ( 3 0 ∘ ) W B = 0.8660 3.60 t = 4.1570 ≈ 4.16 tonnes
Engineering Conclusion: Leg A experiences 9.70 tonnes 9.70\text{ tonnes} 9.70 tonnes of tension—more than double the tension in Leg B ( 4.16 t 4.16\text{ t} 4.16 t ). The rigger must select a chain size for Leg A rated for at least 9.70 tonnes 9.70\text{ tonnes} 9.70 tonnes WLL (e.g., 16mm Grade 80 chain, W L L = 8.0 t WLL = 8.0\text{ t} W LL = 8.0 t is insufficient; 20mm Grade 80, W L L = 12.5 t WLL = 12.5\text{ t} W LL = 12.5 t is required).
Worked Example 2: Two-Crane Tailing Lift Upending Load Allocation
Problem: A 40.0 -tonne 40.0\text{-tonne} 40.0 -tonne distillation column 20.0 metres 20.0\text{ metres} 20.0 metres in length is horizontal. Its CG is located 8.0 metres 8.0\text{ metres} 8.0 metres from the Head Lug (Main Crane) and 12.0 metres 12.0\text{ metres} 12.0 metres from the Tail Lug (Tailing Crane).
Calculate initial crane load sharing in the horizontal position.
Determine the required capacity of the Main Crane when upending is complete.
Solution:
Horizontal Load Sharing ( ϕ = 0 ∘ \phi = 0^\circ ϕ = 0 ∘ ): W m a i n = W ⋅ ( d t a i l L ) = 40.0 t × ( 12.0 m 20.0 m ) = 40.0 × 0.60 = 24.0 tonnes W_{main} = W \cdot \left(\frac{d_{tail}}{L}\right) = 40.0\text{ t} \times \left(\frac{12.0\text{ m}}{20.0\text{ m}}\right) = 40.0 \times 0.60 = 24.0\text{ tonnes} W main = W ⋅ ( L d t ai l ) = 40.0 t × ( 20.0 m 12.0 m ) = 40.0 × 0.60 = 24.0 tonnes W t a i l = W ⋅ ( d h e a d L ) = 40.0 t × ( 8.0 m 20.0 m ) = 40.0 × 0.40 = 16.0 tonnes W_{tail} = W \cdot \left(\frac{d_{head}}{L}\right) = 40.0\text{ t} \times \left(\frac{8.0\text{ m}}{20.0\text{ m}}\right) = 40.0 \times 0.40 = 16.0\text{ tonnes} W t ai l = W ⋅ ( L d h e a d ) = 40.0 t × ( 20.0 m 8.0 m ) = 40.0 × 0.40 = 16.0 tonnes
Upending Completion ( ϕ = 90 ∘ \phi = 90^\circ ϕ = 9 0 ∘ ): When fully vertical, the tailing crane is disconnected and the Main Crane carries 100 % 100\% 100% of the load.
Main Crane Requirement: Must be rated for at least 40.0 tonnes 40.0\text{ tonnes} 40.0 tonnes plus dynamic safety factor.