Study guide
5.4 Wire Rope Sling Inspection & Discard Criteria
LEEA Foundation Certificate Lifting Equipment Engineers Association, UK
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
About the LEEA Foundation Certificate The LEEA Qualification Pathway, Diplomas & the TEAM Card
2 Legislation, Standards & Regulatory Framework
1.1 Health and Safety at Work etc. Act 1974 & Management Regulations 1.2 Provision and Use of Work Equipment Regulations 1998 (PUWER 1998) 1.3 Lifting Operations and Lifting Equipment Regulations 1998 (LOLER 1998) 1.4 Standards, Marking & Documentation 1.5 Controlling Risks, Hazard Management & the 5-Step Risk Assessment
3 Principles of Mechanics & Material Properties
2.1 Forces, Mass, Weight & Center of Gravity 2.2 Mechanical Properties: Stress, Strain & Safety Factors 2.3 WLL, SWL & Rating Concepts 2.4 Heat Treatment & Metallurgy in Lifting Equipment 2.5 Units of Measure, Symbols & Conversions 2.6 Basic Machines, Mechanical Advantage, Velocity Ratio & Efficiency 2.7 Verification, Test Machines, Calibration & NDT Methods
4 Shackles, Eyebolts & Threaded Fittings
3.1 Shackles: Types, Standards & Rating 3.2 Shackle Inspection, Safe Use & Rejection Criteria 3.3 Eyebolts & Eyenuts: Types & Angular Loading 3.4 Eyebolt Installation, Inspection & Rejection Criteria 3.5 Rigging Screws & Turnbuckles
5 Chain Slings & Components
4.1 Chain Sling Construction & Grades 4.2 Chain Components: Master Links, Hooks & Couplers 4.3 Chain Sling Marking, Certification & Safe Use 4.4 Chain Sling Inspection, Wear & Rejection Criteria
6 Wire Rope Slings & Terminations
5.1 Wire Rope Construction & Cores 5.2 Wire Rope Terminations & Assemblies 5.3 Wire Rope Sling Ratings & Safe Use 5.4 Wire Rope Sling Inspection & Discard Criteria
7 Textile Slings & Below-the-Hook Accessories
6.1 Flat Woven Webbing Slings 6.2 Roundslings & High-Performance Fiber Slings 6.3 Textile Sling Inspection, Chemical & Mechanical Damage 6.4 Plate Clamps, Beam Clamps & Below-the-Hook Lifters 6.5 Fibre Rope Slings & Natural Fibre Ropes 6.6 Crane Forks & C-Hooks
8 Manual & Powered Lifting Appliances
7.1 Manual Chain Blocks & Lever Hoists 7.2 Wire Rope Pull-Lifts, Winches & Jacks 7.3 Powered Hoists: Electric & Pneumatic 7.4 Cranes, Structures & Supporting Equipment 7.5 Mobile Cranes, Tower Cranes & Offshore Cranes 7.6 Offshore Containers, Pad Eyes & Lifting Sets
9 Rigging Calculations, Mode Factors & Complex Lifts
8.1 Uniform Load Method (ULM) for Multi-Leg Slings 8.2 Trigonometric Method for Multi-Leg Slings 8.3 Hitch Mode Factors: Choked, Basket & Wrap Hitches 8.4 Center of Gravity Off-Center & Asymmetric Load Calculations
5.4 Wire Rope Sling Inspection & Discard Criteria
Key Takeaways Explain This Topic AI
Wire rope slings used as lifting accessories require thorough examination at intervals not exceeding 6 months unless a competent-person examination scheme sets another interval, plus appropriate pre-use checks.
One common sling criterion accepts no more than 6 randomly distributed outer-wire breaks in 6d and no more than 14 in 30d; the applicable sling standard and manufacturer instructions control the exact limit.
Concentrated breaks, breaks at terminations, valley breaks, severe corrosion, kinks, birdcaging, heat damage and core failure can require withdrawal before a simple random-break count is reached.
Diameter loss must be assessed by the method and limit for the sling construction and manufacturer; it is not safe to apply a universal 7% rule to every wire rope sling.
When a limit is reached or the rope condition creates doubt, quarantine the sling for competent-person assessment rather than continuing to use it until a numerical threshold is exceeded.
Last updated: August 2026
5.4 Wire Rope Sling Inspection & Discard Criteria
Steel wire rope slings are subjected to rigorous mechanical, environmental, and operational stresses during their service life. Over time, cyclic flexure, abrasion, impact loading, chemical exposure, and thermal cycles induce progressive degradation. Because wire ropes consist of numerous individual load-bearing elements, structural deterioration often manifests incrementally before catastrophic collapse occurs.
To ensure absolute safety during overhead lifting, statutory regulations—specifically the UK Lifting Operations and Lifting Equipment Regulations 1998 (LOLER) —and international technical standards ( BS ISO 4309 and BS EN 13414-2 ) mandate rigorous inspection regimes and clear, uncompromised discard criteria for wire rope slings.
1. Statutory Inspection Framework under LOLER 1998
Under LOLER 1998, wire rope slings are legally classified as lifting accessories . As such, they are subject to three distinct tiers of inspection: STATUTORY INSPECTION REGIME (LOLER 1998 / BS EN 13414-2)
- 1. PRE-USE CHECK 2. INTERIM INSPECTION 3. THOROUGH EXAMINATION
- Every shift by rigger Driven by harsh duty Statutory every 6 MONTHS
- Visual & tactile Formal documented check By independent Competent Person
Pre-Use Check (Regulation 8): Conducted by the slinger/rigger prior to every lifting shift. A visual and tactile hands-on pass along the entire length of the sling to detect obvious kinks, broken wires, severe crushing, ferrule damage, or missing marking tags.
Interim Inspection: Formal documented checks conducted at determined intervals between thorough examinations. Mandatory when slings are used in arduous environments (e.g., offshore platforms, hot metal foundries, tunneling, or acidic chemical plants).
Statutory Thorough Examination (Regulation 9(3)(a)(i)): Mandatory comprehensive examination conducted by a legally defined Competent Person at maximum intervals of 6 months (or in accordance with an examination scheme drawn up by a competent person). The results must be formally recorded in a signed Certificate of Thorough Examination.
2. Quantitative Broken Wire Discard Criteria (BS ISO 4309 / BS EN 13414-2)
Broken wires are the most common indicator of fatigue and abrasive wear. The number, distribution, and location of broken outer wires must be counted over specific reference lengths measured in rope diameters ( d d d ) . BROKEN WIRE MEASUREMENT LENGTHS
- |<------------------ 3d Length ------------------>|
- |<-------------------------------- 6d Length -------------------------------->|
- ===============================================================================
- [wire] [wire] [X] [wire] [wire] [X] [wire] [wire] [wire] [X] [wire] [X]
- ===============================================================================
- Discard Limits for 6-Strand and 8-Strand Wire Rope Slings
According to BS ISO 4309 and BS EN 13414-2, a wire rope sling MUST be taken out of service and discarded immediately if the number of broken outer wires reaches or exceeds the following quantitative thresholds:
Discard Category Measurement Reference Length Maximum Permissible Broken Wires Action upon Reaching Limit
Randomly Distributed (6-strand / 8-strand) Over 6 Rope Diameters ( 6 d 6d 6 d ) 6 Broken Wires IMMEDIATE DISCARD
Randomly Distributed (6-strand / 8-strand) Over 3 Rope Diameters ( 3 d 3d 3 d ) 3 Broken Wires IMMEDIATE DISCARD
Concentrated in Single Strand Over 6 Rope Diameters ( 6 d 6d 6 d ) 2 Broken Wires in same strand IMMEDIATE DISCARD
- Valley Broken Wires Any length 1 Broken Wire between strands IMMEDIATE DISCARD
- Termination Entry Breaks Adjacent to ferrule/thimble 1 Broken Wire at termination IMMEDIATE DISCARD
- Critical Wire Break Definitions
Valley Broken Wires: A wire fracture occurring in the inter-strand valley where two outer strands meet. Valley breaks indicate deep internal wire breakage or core collapse, signifying severe internal structural deterioration. Zero tolerance: A single valley break requires immediate discard!
Termination Entry Breaks: Wires breaking immediately adjacent to an aluminum ferrule, steel sleeve, or socket entry. Indicates concentrated bending fatigue or improper swaging fitments. Zero tolerance: A single break at the termination requires immediate discard!
3. Severe Mechanical Deformities & Structural Distortions
Mechanical deformities distort the internal geometric balance of the rope, causing localized stress spikes and immediate loss of strength. Any sling exhibiting the following deformities must be discarded immediately (repair or straightening is strictly illegal): 1. BIRDCAGING 2. KINKING
- Outer strands burst outward Sharp permanent angular bend
- exposing core shearing internal wires
- .----. \ /
- / \ \/
- | (FC) | <-- Core exposed /\
- \ / / \
- '----'
- 3. CORE COLLAPSE 4. BASKET DEFORMATION
- Rope diameter collapses Strands bulge into basket shape
- =====\ /===== =====( ( ) )=====
- \/
- A. Birdcaging
Description: Outer strands unlay and burst radially outward from the core, forming a cage-like structure that exposes the internal core.
Root Cause: Sudden release of tension (shock un-weighting) or severe torsional shock on a twisted line.
Action: IMMEDIATE DISCARD.
B. Kinking
Description: A tight, permanent angular bend in the rope created when a loop or twist is pulled straight under tension without allowing the rope to rotate.
Mechanics: Kinking deforms outer wires, shears internal core wires, distorts strand lay, and causes catastrophic local loss of strength.
Action: IMMEDIATE DISCARD. (Attempting to hammer out or unbend a kink is strictly prohibited).
C. Core Collapse & Core Protrusion
Description: The central core (FC or IWRC) breaks, degrades, or extrudes outward between the outer strands.
Root Cause: Severe crushing, dynamic shock loading, or high thermal exposure.
Action: IMMEDIATE DISCARD.
D. Basket Deformation & Strand Displacement
Description: Localized displacement of one or more outer strands creating an open basket bulge or high strand.
Action: IMMEDIATE DISCARD.
E. Localized Flattening & Crushing
Description: Rope cross-section flattened by impact or heavy pressure against sharp corners.
Discard Limit: If the rope diameter is flattened by > 10 % > 10\% > 10% to 20 % 20\% 20% of its nominal diameter, the sling must be discarded.
4. Diameter Reduction, Wear & Corrosion MEASURING WIRE ROPE DIAMETER WITH VERNIER CALIPERS
- INCORRECT METHOD (Flat-to-Flat) CORRECT METHOD (Crown-to-Crown)
- [CALIPER JAWS] [CALIPER JAWS]
- | | | |
- v v v v
- (o)----(o) (O)========(O)
- / \ / \
- (o) (o) (O) (O)
- \ / \ /
- (o)----(o) (O)========(O)
- A. Diameter Reduction Measurement
Measurement Technique: Rope diameter MUST be measured using vernier calipers across the widest external crown points (Crown-to-Crown). Measuring across flats yields a false low reading.
Discard Criterion: A wire rope sling must be discarded if the nominal rope diameter ( d d d ) decreases by 7 % 7\% 7% or more compared to the nominal specified diameter (or 10 % 10\% 10% compared to an un-deformed section of the same rope).
Engineering Significance: A the applicable documented limit reduction in diameter indicates severe internal wire friction wear, internal corrosion, or core collapse, even if outer wire breaks are not yet visible.
B. Corrosion Classifications & Discard Limits
Light Surface Oxidation: Light surface rusting removable with an oiled cloth. Acceptable; sling can remain in service.
Severe External Corrosion: Rough, pitted wire surfaces, loose outer wires, or reduced wire cross-section. IMMEDIATE DISCARD.
Internal Corrosion: Marked by dry red rust powder ("bleeding rust") exuding from the valleys between strands. Indicates internal core decay and hidden wire breaks. IMMEDIATE DISCARD.
- 5. Thermal Damage & Termination Rejection Criteria
- Thermal / Electrical Damage
Arc Strikes: Electrical arc contact (e.g., from welding ground clamps) causes localized melting, grain structure embrittlement, and immediate wire failure. IMMEDIATE DISCARD.
Heat Discoloration: Blueing, blackening, or oxidation of steel wires from exposure to excessive heat ( > 400 ∘ C > 400^\circ\text{C} > 40 0 ∘ C ). IMMEDIATE DISCARD.
Termination Inspection Checks
Ferrule Condition: Discard if the aluminum or steel ferrule exhibits cracking, splitting, excessive abrasion, severe gouging, or mechanical deformation.
Tell-Tale Tail Slippage: Discard if the wire rope tail shows evidence of slipping into or through the ferrule.
Thimble Integrity: Discard if the thimble is distorted, pinched, cracked, or has sharp edges cutting into the rope wires.
Marking & Traceability: Under LOLER 1998 Regulation 8, any sling missing its permanent legibility tag (stamped with WLL, serial number, grade, and CE/UKCA mark) must be immediately withdrawn from service until re-certified.