Study guide
14.4 Impression Materials, Cements & Other Materials
MFDS Part 1 Membership of the Faculty of Dental Surgery
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
Current Exam Facts How to Use This Guide Eligibility, Booking & the MFDS Pathway
2 Basic Sciences, History Taking & Clinical Assessment
1.1 Head & Neck Anatomy and Underpinning Basic Sciences 1.2 History Taking, Communication & Clinical Examination 1.3 Special Tests, Investigations & Diagnostic Accuracy 1.4 Differential Diagnosis, Triage & When to Biopsy 1.5 Dental Anomalies & Developmental Conditions
3 Cariology, Operative Dentistry & Endodontics
2.1 Cariology & Caries Diagnosis 2.2 Caries Management & Prevention 2.3 Operative Dentistry & Cavity Preparation 2.4 Endodontics 2.5 Tooth Surface Loss & Tooth Discolouration
4 Periodontology & Prosthodontics
3.1 Periodontology 3.2 Fixed Prosthodontics 3.3 Removable Prosthodontics 3.4 Occlusion & Occlusal Assessment
5 Paediatric Dentistry, Orthodontics & Dental Trauma
4.1 Paediatric Dentistry 4.2 Orthodontics 4.3 Dental Trauma 4.4 Orthodontic Assessment, Indices & Referral 4.5 Impacted Teeth & Radiographic Localisation
6 Oral Surgery, Treatment Planning & Prevention
5.1 Oral Surgery & Extractions 5.2 Treatment Planning & Patient Management 5.3 Prevention & Health Promotion
7 Cardiovascular, Respiratory & Endocrine Disease
6.1 Cardiovascular Disease 6.2 Respiratory Disease 6.3 Endocrine Disease & Diabetes 6.4 Bleeding Disorders & Anticoagulation
8 Haematology, Infection & the Medically Compromised Patient
7.1 Haematology 7.2 Infectious Disease 7.3 The Medically Compromised Patient 7.4 Neurological & Gastrointestinal Disease
9 Medical Emergencies in Dental Practice
8.1 Medical Emergencies & Resuscitation 8.2 Anaphylaxis & Acute Allergy 8.3 Emergency Drugs & the Resuscitation Kit
10 Special Care Dentistry, Mental Health & Anxiety Management
9.1 Special Care Dentistry & Patients with Disability 9.2 Mental Health & Behavioural Science 9.3 Dental Anxiety & Behaviour Management
11 Oral Medicine — Mucosal Disease & Orofacial Pain
10.1 Oral Mucosal Disease & Lichen Planus 10.2 Vesiculobullous & Ulcerative Disorders 10.3 Candidiasis & Fungal Infections 10.4 Orofacial Pain & Neuropathic Disorders
12 Oral Pathology — Lesions, Cysts, Tumours & Salivary Glands
11.1 Premalignant Lesions & Oral Cancer 11.2 Odontogenic Cysts 11.3 Odontogenic & Non-Odontogenic Tumours 11.4 Salivary Gland Disease
13 Pharmacology — Local Anaesthesia, Analgesia & Sedation
12.1 Local Anaesthesia 12.2 Analgesics & NSAIDs 12.3 Conscious Sedation
14 Pharmacology — Antimicrobials, Prescribing & Drug Interactions
13.1 Antimicrobials & Antibiotic Stewardship 13.2 Prescribing & Drug Interactions
15 Dental Materials
14.1 Properties & Testing of Dental Materials 14.2 Amalgam & Metal Restorations 14.3 Composite Resin & Adhesive Dentistry 14.4 Impression Materials, Cements & Other Materials
16 Microbiology, Infection Control & Radiology
15.1 Oral Microbiology & Infection Control 15.2 Dental Radiology & Imaging 15.3 Radiation Protection
17 Law, Ethics, Professionalism & Evidence-Based Dentistry
16.1 Consent & Confidentiality 16.2 GDC Standards & Professionalism 16.3 Safeguarding & Duty of Candour 16.4 Evidence-Based Dentistry & Research Methods 16.5 Records, Information Governance & Regulation 16.6 Communication, Teamworking, Human Factors & Raising Concerns
18 Statistics, Dental Public Health, Critical Appraisal & Exam Strategy
17.1 Statistics & Critical Appraisal 17.2 Dental Public Health & Epidemiology 17.3 SBA Technique & Exam Strategy 17.4 Final Review & Key Points
14.4 Impression Materials, Cements & Other Materials
Key Takeaways Explain This Topic AI
Elastomeric impression materials — addition silicones (polyvinyl siloxane), polyethers, and condensation silicones — give high accuracy and elastic recovery; hydrocolloids (agar, alginate) are less accurate but cheap and useful for study models.
Addition silicone (PVS) is the most dimensionally stable and accurate, hydrophobic (needs surfactant), and has the best elastic recovery; polyether is hydrophilic and accurate but absorbs water and is stiffer to remove.
GIC chemically bonds to tooth and releases fluoride but is weak and moisture-sensitive; RMGIC adds light-cure resin for command set; compomers are polyacid-modified composites needing bonding.
Zinc phosphate cement is strong but non-adhesive and acidic to the pulp; zinc polycarboxylate adheres to tooth; resin luting cements bond both to tooth (adhesive) and restoration (silane/MDP) for ceramic restorations.
Dimensional accuracy is set by handling: single-stage vs two-stage putty-wash, mixing technique, syringing light-body, and pouring within the stability window.
Last updated: August 2026
Impression Materials
A dental impression records negative detail of the prepared tooth and surrounding structures; the cast poured from it must be dimensionally accurate to produce a well-fitting indirect restoration.
Hydrocolloids
Material Reversible? Accuracy Use
Alginate (irreversible hydrocolloid) No (chemical set) Moderate — limited detail, dimensional instability Study models, orthodontic models, primary impressions
Agar (reversible hydrocolloid) Yes (thermoreversible gel–sol) Good accuracy, hydrophilic Rarely used now; needs water-cooled trays
Alginate must be poured promptly (within the hour) or stored in 100% humidity because it shrinks by syneresis (water loss) and expands by imbibition (water uptake).
Elastomers
- Property Addition silicone (PVS) Polyether Condensation silicone Polysulphide
- Accuracy Excellent Excellent Good (less stable) Good
- Dimensional stability Excellent (can pour days later) Good (if dry) Poor (shrinkage on set) Moderate
- Elastic recovery Best Excellent Moderate Good
- Hydrophilicity Hydrophobic (needs surfactant) Hydrophilic Hydrophobic Moderate
- Stiffness on set Low–medium (easy removal) High (stiff; harder to remove, atraumatic risk) Low Low
- Taste/smell Neutral Pleasant Neutral Unpleasant (sulphur)
- Hydrogen release None (addition) None Yes (can inhibit addition silicone) —
- Technique — Putty-Wash vs Single-Stage
Two-stage putty-wash — a putty preliminary impression is taken, relieved, then a light-body wash captures detail. Accurate but the putty can lock undercuts; careful relief prevents distortion.
Single-stage (simultaneous) — putty and wash mixed and seated together; faster, technique-dependent on even wash distribution.
Hydrogen Inhibition
Condensation silicones release hydrogen gas as they set, which can inhibit the surface set of an addition silicone used in the same impression. Avoid latex gloves with addition silicone (sulphur inhibits platinum catalyst); use nitrile or vinyl. Use a surfactant to wet the moist tooth before PVS.
Cements (Luting Agents)
Cement Strength Adhesion Notes / use
Zinc phosphate High compressive, low tensile None (mechanical) Classic luting agent; acidic initial pH irritates pulp; needs liner
Zinc polycarboxylate Moderate Adheres to tooth (polyacrylic acid to Ca²⁺) Pulp-friendly; lower strength; for less retentive prep needs mechanical retention
Glass ionomer (GIC) Moderate Chemical bond to tooth, releases fluoride Soluble early; film thickness critical
Resin-modified GIC (RMGIC) Moderate–high Chemical + resin Command set portion; fluoride release; common for crowns
Resin cement High Adhesive (tooth via adhesive, ceramic via silane/MDP) Highest retention; technique-sensitive; for ceramic and bonded restorations
Selection: resin cement for all-ceramic and bonded restorations; GIC/RMGIC for metal crowns and where moisture control is harder; polycarboxylate for sensitive pulps; phosphate as a reliable traditional option where good retention form exists.
Liners, Bases, and Varnishes
Liner (thin, <0.5 mm) — protects the pulp or medicates it: calcium hydroxide (Dycal) for indirect/ direct pulp caps, stimulating reparative dentine; RMGIC liner for pulpal floor.
Base (thicker, 1–2 mm) — provides thermal insulation and stress distribution under amalgam: GIC , ZOE , or RMGIC .
Varnish — thin resin to seal dentinal tubules and reduce microleakage under amalgam (largely superseded by dentine bonding agents).
Calcium Hydroxide and MTA
Calcium hydroxide — high pH (~12) causes mild necrosis that triggers reparative dentine bridge formation; used for direct and indirect pulp caps.
MTA / bioceramic — now preferred for direct pulp capping and perforation repair; sets in moisture, biocompatible, seals well; slower set (replaced by faster bioceramics in many uses).
Selection by Situation — a Quick Map
- Situation Material of choice
- Class II amalgam, deep floor Base with GIC/RMGIC; cavity varnish or bonding agent at margins
- All-ceramic crown Resin cement (adhesive to tooth + silane to ceramic)
- Metal crown, good retention GIC or RMGIC; phosphate acceptable
- Direct pulp cap Calcium hydroxide or bioceramic (MTA)
- Final impression for crowns Addition silicone (PVS) two-stage putty-wash, or polyether
- Study model Alginate, poured within the hour
- Pitfalls
Storing an alginate impression dry → syneresis shrinkage and distorted cast.
Latex gloves inhibiting addition silicone set at the impression surface.
Mixing condensation silicone (hydrogen) with addition silicone → surface inhibition.
Pouring polyether wet → water absorption and swelling distortion.
Using a resin cement without proper tooth adhesive or ceramic silane → low bond and early failure.
Disinfection of Impressions
All impressions must be disinfected before handling or pouring to control cross-infection. The method depends on the material's dimensional stability and water sensitivity.
Material Recommended disinfection Stability after disinfection
Addition silicone (PVS) Immersion in glutaraldehyde or sodium hypochlorite Excellent — tolerates immersion, can be poured days later
Polyether Spray disinfection only — AVOID immersion Absorbs water and swells if immersed; pour within 24 hours
Alginate Brief immersion (~10 minutes) or spray, then pour promptly Dimensionally unstable — pour within the hour
- Condensation silicone Brief immersion or spray Poor stability — pour as soon as possible
- Working and Setting Times
Mix thoroughly within the working time so the material is homogeneous before it begins to polymerise; seat the tray before the onset of set to avoid distortion and capture fine detail. Once removed, pour within the material's dimensional-stability window : alginate within the hour (or store at 100% humidity), addition silicone can wait days, and polyether should be poured promptly and kept dry.
Digital Impressions (Intraoral Scanning)
Intraoral scanning captures the preparation and margins directly as a digital file, removing the need for impression material, disinfection, and a pour. Advantages include improved patient tolerance, no material-related distortion, and a direct digital workflow for crowns, bridges, and implant frameworks. For single units, accuracy is comparable to PVS; the scan captures the margin and can be reviewed on screen before the patient leaves. However, deep subgingival margins and bleeding sulci can still challenge scan accuracy, and a retraction cord or paste may be needed to expose it.