Study guide
Section 6.2: Industrial Networks & Cabling
USPS Postal Exam 955 Technical Maintenance
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
1.1 USPS 955 Exam Structure & Scoring 1.2 Personal Characteristics & Experience Inventory 1.3 PSI Testing & Multicraft Test Strategy
2 Chapter 2: Electronics
Section 2.1: Digital Logic Gates & Truth Tables Section 2.2: Combinational & Sequential Logic Section 2.3: Analog Electronic Devices Section 2.4: Operational Amplifiers (Op-amps) & Filters Section 2.5: Power Supplies & Rectification Section 2.6: Electronic Schematic & Symbol Reading
3 Chapter 3: Electrical Fundamentals
Section 3.1: Ohm's Law & Circuit Calculations Section 3.2: Capacitance, Inductance & RC/RL Networks Section 3.3: AC & DC Power Fundamentals Section 3.4: Three-Phase Power & Motors
4 Chapter 4: Mechanical Systems
Section 4.1: Power Transmission & Machine Elements Section 4.2: Bearings & Lubrication Section 4.3: Hydraulic Principles & Components Section 4.4: Pneumatic Principles & Components
5 Chapter 5: HVAC & Refrigeration
Section 5.1: The Refrigeration Cycle Section 5.2: Refrigerants & Environmental Controls Section 5.3: Heating & Combustion Systems Section 5.4: HVAC Control Systems
6 Chapter 6: Computers, PLCs & Networking
Section 6.1: PC Hardware & Operating Systems Section 6.2: Industrial Networks & Cabling Section 6.3: PLC Fundamentals & I/O Systems Section 6.4: PLC Troubleshooting & Ladder Logic
7 Chapter 7: Spatial Reasoning
Section 7.1: Object Rotation & 3D Visualization Section 7.2: Paper Folding & Pattern Matching Section 7.3: Part Assembly & Mechanical Drawing Section 7.4: Spatial Visualization Strategies
8 Chapter 8: Mathematical Reasoning
Section 8.1: Applied Algebra & Formulas Section 8.2: Geometric Formulas & Measurement Section 8.3: Unit Conversions & Scale Section 8.4: Readout & Indicator Problems
9 Chapter 9: Industrial Safety & Standards
9.1 Lockout/Tagout (LOTO) Procedures 9.2 Electrical Safety & NFPA 70E 9.3 Workplace Hazards, PPE & SDS 9.4 Safe Tool Usage & Material Handling
Section 6.2: Industrial Networks & Cabling
Key Takeaways Explain This Topic AI
Modern Ethernet networks operate in full-duplex mode using switches to eliminate data collisions.
Shielded Twisted Pair (STP) cabling is required in industrial settings to block Electromagnetic Interference (EMI) from motors.
The TIA-568B cabling standard starts with White/Orange and Orange, whereas TIA-568A starts with White/Green and Green.
Multimode fiber optics use LEDs for short distances (up to 2km), while Single-mode uses lasers for long distances (up to 40km+).
Command-line diagnostics like ping and tracert use ICMP packets to identify connection loss and network hop latency.
Last updated: July 2026
Industrial Networks & Cabling in Postal Infrastructure
In modern postal sorting facilities, processing machines must communicate in real time with centralized servers, databases, and other machinery. This communication is handled by industrial networks using standard Ethernet systems, specialized cabling, and the Transmission Control Protocol/Internet Protocol (TCP/IP) suite. Technicians must understand networking hardware, cabling, addressing, and command-line diagnostic tools.
Ethernet Standards and Media Access Control
Ethernet is the standard technology for Local Area Networks (LANs), standardized under the Institute of Electrical and Electronics Engineers (IEEE) 802.3 working group.
Legacy Ethernet networks used Carrier Sense Multiple Access with Collision Detection (CSMA/CD) to manage data transmission on shared media. In half-duplex mode, devices cannot transmit and receive simultaneously, and data collisions can occur. Modern networks operate in full-duplex mode using dedicated switches, allowing simultaneous two-way communication and eliminating collisions.
Every network interface card has a unique, hardcoded physical address known as the Media Access Control (MAC) address. Operating at Layer 2 (Data Link Layer) of the Open Systems Interconnection (OSI) model, network switches use MAC addresses to forward data frames only to the specific port connected to the destination device, optimizing bandwidth.
Copper Cabling and RJ-45 Pinouts
Twisted-pair copper cables are the most common media in local networks. They consist of eight color-coded insulated copper wires twisted in pairs to reduce crosstalk (electromagnetic interference between adjacent wire pairs).
UTP vs. STP
Unshielded Twisted Pair (UTP): Standard ethernet cable with no extra shielding. It is flexible and inexpensive but susceptible to electrical noise.
Shielded Twisted Pair (STP): Contains an outer metal foil or braided shield surrounding the conductors to block external Electromagnetic Interference (EMI) and Radio Frequency Interference (RFI). STP is mandatory in industrial environments near high-voltage motors, variable frequency drives, or solenoids.
RJ-45 Standards (TIA-568A and TIA-568B)
Cables terminate in Registered Jack 45 (RJ-45) connectors. The Telecommunications Industry Association (TIA) defines two wiring standards, TIA-568A and TIA-568B.
- Pin Number TIA-568A Wire Color TIA-568B Wire Color
- Pin 1 White/Green White/Orange
- Pin 2 Green Orange
- Pin 3 White/Orange White/Green
- Pin 4 Blue Blue
- Pin 5 White/Blue White/Blue
- Pin 6 Orange Green
- Pin 7 White/Brown White/Brown
- Pin 8 Brown Brown
A straight-through cable has the same pinout standard (usually TIA-568B) on both ends, used to connect dissimilar devices (e.g., PC to Switch). A crossover cable has TIA-568A on one end and TIA-568B on the other, crossing pins 1 and 3, and 2 and 6. This was historically used to connect similar devices (e.g., Switch to Switch or PC to PC), though modern hardware utilizes Automatic Medium-Dependent Interface Crossover (Auto-MDIX) to automatically detect and adjust the port connection electronically.
Fiber Optic Cabling
In large postal facilities, distances can exceed the 100-meter (328 feet) limit of copper Ethernet cabling. In these cases, and where electrical noise is severe, fiber optic cabling is used. Fiber optics transmit data as light pulses through glass or plastic cores, providing total immunity to EMI/RFI and much higher bandwidth.
Fiber cables are categorized into two types:
Multimode Fiber (MMF): Has a relatively large core (50 to 62.5 microns) that allows multiple paths (modes) of light to propagate. It uses inexpensive Light-Emitting Diode (LED) transmitters. MMF is ideal for shorter distances, typically up to 2 kilometers, making it suitable for linking control rooms to sorting machines within a single facility.
Single-mode Fiber (SMF): Has a tiny core (approximately 9 microns) through which only a single path of light travels. It requires precise laser transmitters. SMF has extremely low signal loss and can transmit data over distances up to 40 kilometers or more, commonly used for facility-to-facility links.
TCP/IP Architecture, Addressing, and Subnetting
The TCP/IP model is the foundation of network communication, consisting of four layers: Network Interface (Link), Internet, Transport, and Application.
IP Addressing (IPv4)
An Internet Protocol Version 4 (IPv4) address is a 32-bit logical address written in dotted-decimal format (e.g., 192.168.1.50 ), divided into four 8-bit octets. An IP address consists of a network portion and a host portion.
The subnet mask determines which part of the address represents the network and which part represents the host. For example, a subnet mask of 255.255.255.0 (or /24 in Classless Inter-Domain Routing notation) means the first 24 bits represent the network and the last 8 bits represent individual host addresses.
For communication outside the local network, devices send packets to their designated default gateway , which is the IP address of the local router. Routers operate at Layer 3 (Network Layer) of the OSI model and route packets across different networks based on logical IP addresses.
Network Diagnostics and Troubleshooting Tools
When a sorting machine loses connection to the server, technicians use command-line utility tools to isolate the failure.
Diagnostic Command-Line Tools
ping : Uses Internet Control Message Protocol (ICMP) echo requests to verify network connectivity with a destination IP or domain. The tool measures the round-trip time and packet loss percentage. A failed ping indicates a network break, incorrect IP settings, or firewall blocking.
tracert (Windows) / traceroute (Linux): Traces the path that a packet takes to reach a destination host, displaying the IP address and response times of each intermediate router (hop). It helps identify which router or segment is dropped or experiencing latency.
ipconfig (Windows) / ifconfig (Linux): Displays the local computer's network interface details, including the assigned IP address, subnet mask, default gateway, and MAC address. Using ipconfig /release and ipconfig /renew can reset DHCP configurations.
netstat : Displays active TCP connections, listening ports, and routing tables.
arp : Displays the Address Resolution Protocol cache, which maps IP addresses to physical MAC addresses on the local network.
Troubleshooting Network Issues Flow
Physical Layer Check : Verify link status LEDs on the network card and switch ports. A dark LED indicates a disconnected cable, a broken wire, or a failed port.
IP Configuration Check : Run ipconfig to ensure the host has a valid IP address. If it shows an Automatic Private IP Addressing (APIPA) address in the range 169.254.0.1 to 169.254.255.254 , the PC was unable to contact a DHCP server.
Local Connectivity Check : Ping the loopback address ( 127.0.0.1 ) to test the TCP/IP stack. Then ping the default gateway.
Remote Connectivity Check : Ping the destination server. If local ping works but remote ping fails, run tracert to find the failing router.