Study guide
Section 8.3: Unit Conversions & Scale
USPS Postal Exam 955 Technical Maintenance
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
1.1 USPS 955 Exam Structure & Scoring 1.2 Personal Characteristics & Experience Inventory 1.3 PSI Testing & Multicraft Test Strategy
2 Chapter 2: Electronics
Section 2.1: Digital Logic Gates & Truth Tables Section 2.2: Combinational & Sequential Logic Section 2.3: Analog Electronic Devices Section 2.4: Operational Amplifiers (Op-amps) & Filters Section 2.5: Power Supplies & Rectification Section 2.6: Electronic Schematic & Symbol Reading
3 Chapter 3: Electrical Fundamentals
Section 3.1: Ohm's Law & Circuit Calculations Section 3.2: Capacitance, Inductance & RC/RL Networks Section 3.3: AC & DC Power Fundamentals Section 3.4: Three-Phase Power & Motors
4 Chapter 4: Mechanical Systems
Section 4.1: Power Transmission & Machine Elements Section 4.2: Bearings & Lubrication Section 4.3: Hydraulic Principles & Components Section 4.4: Pneumatic Principles & Components
5 Chapter 5: HVAC & Refrigeration
Section 5.1: The Refrigeration Cycle Section 5.2: Refrigerants & Environmental Controls Section 5.3: Heating & Combustion Systems Section 5.4: HVAC Control Systems
6 Chapter 6: Computers, PLCs & Networking
Section 6.1: PC Hardware & Operating Systems Section 6.2: Industrial Networks & Cabling Section 6.3: PLC Fundamentals & I/O Systems Section 6.4: PLC Troubleshooting & Ladder Logic
7 Chapter 7: Spatial Reasoning
Section 7.1: Object Rotation & 3D Visualization Section 7.2: Paper Folding & Pattern Matching Section 7.3: Part Assembly & Mechanical Drawing Section 7.4: Spatial Visualization Strategies
8 Chapter 8: Mathematical Reasoning
Section 8.1: Applied Algebra & Formulas Section 8.2: Geometric Formulas & Measurement Section 8.3: Unit Conversions & Scale Section 8.4: Readout & Indicator Problems
9 Chapter 9: Industrial Safety & Standards
9.1 Lockout/Tagout (LOTO) Procedures 9.2 Electrical Safety & NFPA 70E 9.3 Workplace Hazards, PPE & SDS 9.4 Safe Tool Usage & Material Handling
Section 8.3: Unit Conversions & Scale
Key Takeaways Explain This Topic AI
Conversions between metric (SI) and imperial systems are common in facilities with both U.S. and foreign machinery.
One inch is equal to exactly 25.4 millimeters (or 2.54 centimeters), which is the primary factor for length conversions.
Temperature conversions use formulas to relate Fahrenheit and Celsius: F = (C * 1.8) + 32.
A drawing scale ratio (e.g., 1:50) relates drawing measurements directly to the actual dimensions of physical structures.
Last updated: July 2026
Section 8.3: Unit Conversions & Scale
Mail processing facilities operated by the United States Postal Service utilize a diverse array of automated equipment sourced from global manufacturers. As a result, technicians must work with components, tools, and technical documentation designed in both the Imperial System (standard U.S. customary units) and the Metric System (International System of Units, or SI ). For instance, a technician might need to determine if a metric fastener can substitute for an imperial bolt, calculate temperature limits between Celsius and Fahrenheit, or interpret scaled architectural and mechanical engineering blueprints to plan machinery installations. This section covers unit conversion techniques and scale drawing interpretation.
The Metric System vs. The Imperial System
The metric system is a base-10 decimal system of measurement. This means all units are based on multiples of ten, making conversions within the system straightforward. Conversions are performed by shifting the decimal point to the left or right.
- Metric Prefixes
- Kilo- ( k k k ): 10 3 10^3 1 0 3 ( 1 , 000 1,000 1 , 000 times the base unit)
- Base Unit : Meter ( m m m ) for length, Gram ( g g g ) for mass, Liter ( L L L ) for volume
- Centi- ( c c c ): 10 − 2 10^{-2} 1 0 − 2 ( 1 / 100 1/100 1/100 of the base unit)
- Milli- ( m m m ): 10 − 3 10^{-3} 1 0 − 3 ( 1 / 1 , 000 1/1,000 1/1 , 000 of the base unit)
- Micro- ( μ \mu μ ): 10 − 6 10^{-6} 1 0 − 6 ( 1 / 1 , 000 , 000 1/1,000,000 1/1 , 000 , 000 of the base unit)
For example, to convert 480 millimeters (mm) 480\text{ millimeters (mm)} 480 millimeters (mm) to meters ( m m m ), move the decimal point three places to the left (dividing by 1000): 480 mm = 0.48 m 480\text{ mm} = 0.48\text{ m} 480 mm = 0.48 m
The imperial system uses historically derived units that do not share a common base. In maintenance, length measurements are frequently expressed in fractional inches (e.g., 1 / 2 " 1/2" 1/2" , 5 / 8 " 5/8" 5/8" , 11 / 16 " 11/16" 11/16" ). Converting within the imperial system requires memorizing specific ratios (e.g., 12 inches = 1 foot 12\text{ inches} = 1\text{ foot} 12 inches = 1 foot , 3 feet = 1 yard 3\text{ feet} = 1\text{ yard} 3 feet = 1 yard ).
Imperial and Metric Conversions
Technicians often need to convert dimensions between systems. The following table highlights the essential conversion factors:
Dimension Metric Unit Imperial Unit Conversion Factor
Length Millimeters ( m m mm mm ) Inches ( i n in in ) 1 in = 25.4 mm 1\text{ in} = 25.4\text{ mm} 1 in = 25.4 mm
Length Centimeters ( c m cm c m ) Inches ( i n in in ) 1 in = 2.54 cm 1\text{ in} = 2.54\text{ cm} 1 in = 2.54 cm
Length Meters ( m m m ) Feet ( f t ft f t ) 1 m ≈ 3.28 ft 1\text{ m} \approx 3.28\text{ ft} 1 m ≈ 3.28 ft
Mass/Weight Kilograms ( k g kg k g ) Pounds ( l b s lbs l b s ) 1 kg ≈ 2.205 lbs 1\text{ kg} \approx 2.205\text{ lbs} 1 kg ≈ 2.205 lbs
Mass/Weight Grams ( g g g ) Ounces ( o z oz oz ) 1 oz ≈ 28.35 g 1\text{ oz} \approx 28.35\text{ g} 1 oz ≈ 28.35 g
Volume Liters ( L L L ) Gallons ( g a l gal g a l ) 1 gal ≈ 3.785 L 1\text{ gal} \approx 3.785\text{ L} 1 gal ≈ 3.785 L
Pressure Bar Pounds/Sq. Inch ( p s i psi p s i ) 1 bar ≈ 14.5 psi 1\text{ bar} \approx 14.5\text{ psi} 1 bar ≈ 14.5 psi
Worked Example: Metric to Imperial Length Conversion
A replacement linear actuator shaft has a length specified in a catalog as 350 mm 350\text{ mm} 350 mm . A technician wants to know the length in inches to see if it will clear an adjacent safety guard.
Step 1: Set up the dimensional analysis Length in inches = 350 mm 25.4 mm/inch \text{Length in inches} = \frac{350\text{ mm}}{25.4\text{ mm/inch}} Length in inches = 25.4 mm/inch 350 mm
Step 2: Perform the division Length in inches ≈ 13.78 inches \text{Length in inches} \approx 13.78\text{ inches} Length in inches ≈ 13.78 inches
Temperature Conversions
In HVAC (Heating, Ventilation, and Air Conditioning) systems and motor monitoring, temperature limits may be expressed in Fahrenheit ( ∘ F ^\circ\text{F} ∘ F ) or Celsius ( ∘ C ^\circ\text{C} ∘ C ). The conversion formulas are: T ∘ F = ( T ∘ C × 1.8 ) + 32 T_{^\circ\text{F}} = (T_{^\circ\text{C}} \times 1.8) + 32 T ∘ F = ( T ∘ C × 1.8 ) + 32 T ∘ C = T ∘ F − 32 1.8 T_{^\circ\text{C}} = \frac{T_{^\circ\text{F}} - 32}{1.8} T ∘ C = 1.8 T ∘ F − 32
For example, if a variable-frequency drive controller reports an internal heat sink temperature of 113 ∘ F 113^\circ\text{F} 11 3 ∘ F , the Celsius equivalent is: T ∘ C = 113 − 32 1.8 = 81 1.8 = 45 ∘ C T_{^\circ\text{C}} = \frac{113 - 32}{1.8} = \frac{81}{1.8} = 45^\circ\text{C} T ∘ C = 1.8 113 − 32 = 1.8 81 = 4 5 ∘ C
Interpreting Scaled Drawings
An engineering drawing or architectural blueprint represents physical structures or machine components scaled down to fit on paper. The scale ratio on a drawing indicates the relationship between the size of the drawing elements and the actual physical objects.
Types of Scales
Ratio Scale (e.g., 1 : 20 1:20 1 : 20 ): This is a unitless scale. It means 1 1 1 unit of any length on the drawing represents 20 20 20 of those same units in the actual physical object. If a drawing dimension is 5 cm 5\text{ cm} 5 cm long, the real object is 5 cm × 20 = 100 cm = 1 meter 5\text{ cm} \times 20 = 100\text{ cm} = 1\text{ meter} 5 cm × 20 = 100 cm = 1 meter .
Customary Architectural Scale (e.g., 1 / 4 " = 1 ′ − 0 " 1/4" = 1'-0" 1/4" = 1 ′ − 0" ): This is commonly used in floor plans and layout drawings. It means every quarter-inch on the drawing represents one foot in the actual building.
Step-by-Step Scale Calculation
To find the actual distance or dimension from a scaled drawing:
Identify the Scale : Find the scale ratio in the drawing's title block or legend.
Measure the Drawing Distance : Use a ruler to measure the distance between two points on the physical blueprint.
Multiply by the Scale Factor : Multiply the measured distance by the scale factor (the second number in a ratio, or the ratio conversion factor).
Convert Units (if necessary) : Ensure the final dimension is in the desired units (e.g., feet, meters).
Worked Example: Blueprint Scale
A technician is reviewing a facility floor plan to determine if a new parcel sorting machine will fit. The blueprint scale is 1 : 60 1:60 1 : 60 . On the drawing, the length of the room is measured as 15 cm 15\text{ cm} 15 cm . Calculate the actual length of the room in meters.
Step 1: Multiply by the scale factor Actual Length = 15 cm × 60 = 900 cm \text{Actual Length} = 15\text{ cm} \times 60 = 900\text{ cm} Actual Length = 15 cm × 60 = 900 cm
Step 2: Convert centimeters to meters Actual Length = 900 cm 100 cm/meter = 9 meters \text{Actual Length} = \frac{900\text{ cm}}{100\text{ cm/meter}} = 9\text{ meters} Actual Length = 100 cm/meter 900 cm = 9 meters The actual length of the room is 9 meters 9\text{ meters} 9 meters .
Dimensional Analysis (Factor-Label Method)
When executing complex conversions involving multiple units (such as converting flow rate from gallons per minute to liters per second), technicians use dimensional analysis . This involves writing conversion factors as fractions and multiplying them so that unwanted units cancel out.
For example, convert a flow rate of 10 gallons per minute (gpm) 10\text{ gallons per minute (gpm)} 10 gallons per minute (gpm) to liters per second:
Convert gallons to liters ( 1 gal ≈ 3.785 L 1\text{ gal} \approx 3.785\text{ L} 1 gal ≈ 3.785 L ): 10 gal 1 min × 3.785 L 1 gal = 37.85 L/min \frac{10\text{ gal}}{1\text{ min}} \times \frac{3.785\text{ L}}{1\text{ gal}} = 37.85\text{ L/min} 1 min 10 gal × 1 gal 3.785 L = 37.85 L/min
Convert minutes to seconds ( 1 min = 60 seconds 1\text{ min} = 60\text{ seconds} 1 min = 60 seconds ): 37.85 L 1 min × 1 min 60 sec ≈ 0.63 liters per second \frac{37.85\text{ L}}{1\text{ min}} \times \frac{1\text{ min}}{60\text{ sec}} \approx 0.63\text{ liters per second} 1 min 37.85 L × 60 sec 1 min ≈ 0.63 liters per second
Fraction-to-Decimal Conversions in Maintenance
Because imperial fasteners and drills are sized in fractions of an inch, technicians must quickly convert fractions to decimals to compare them to caliper readings.
To convert a fraction to a decimal, divide the numerator by the denominator.
- 1 / 8 " = 1 ÷ 8 = 0.125 " 1/8" = 1 \div 8 = 0.125" 1/8" = 1 ÷ 8 = 0.125"
- 3 / 8 " = 3 ÷ 8 = 0.375 " 3/8" = 3 \div 8 = 0.375" 3/8" = 3 ÷ 8 = 0.375"
- 5 / 16 " = 5 ÷ 16 = 0.3125 " 5/16" = 5 \div 16 = 0.3125" 5/16" = 5 ÷ 16 = 0.3125"
- 11 / 16 " = 11 ÷ 16 = 0.6875 " 11/16" = 11 \div 16 = 0.6875" 11/16" = 11 ÷ 16 = 0.6875"
Comparing a caliper reading of 0.325 " 0.325" 0.325" to a nominal bolt size of 5 / 16 " 5/16" 5/16" , the technician can identify that the bolt is slightly smaller ( 0.3125 " 0.3125" 0.3125" ) and the hole may be oversized.