Study guide
1.3 Standards of Practice: Designations, Address Changes & License Use
Virginia Journeyman Plumber Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Exam Overview, Virginia Licensing Law & Standards of Practice
1.1 Exam Format, Permitted References & Open-Book Strategy 1.2 Definitions, Licensure Requirement & Qualification for the Exam 1.3 Standards of Practice: Designations, Address Changes & License Use 1.4 Standards of Conduct, Prohibited Acts & Revocation of Licensure
2 Chapter 2: Renewal, USBC Administration & General Regulations
2.1 License Renewal, Continuing Education & Reinstatement 2.2 Virginia USBC Administration, Permits, Inspections & Required Tests 2.3 General Regulations: Materials, Protection, Support, Trenching & Structural Safety
3 Chapter 3: Plumbing Fixtures, Clearances & Temperature Control
3.1 Minimum Plumbing Facilities: Table 403.1, Calculations & Separate Facilities 3.2 Fixture Installation: Clearances, Compartments, Connections, Showers & Accessibility 3.3 Water Conservation, Temperature-Limiting Devices, Flushing Devices & Emergency Fixtures
4 Chapter 4: Fixture Traps, Trap Seals & Interceptors
4.1 Fixture Traps, Trap Seals & Trap Seal Protection 4.2 Grease Interceptors: Where Required, Sizing, Flow Control & Virginia's Disposer Rule 4.3 Oil Separators, Sand & Lint Interceptors, Other Interceptors & Corrosive Waste
5 Chapter 5: Sanitary Drainage Systems & Sizing
5.1 Drainage Principles & Drainage Fixture Units (Tables 709.1 and 709.2) 5.2 Horizontal Branches, Building Drains & Building Sewers: Slope, Sizing & Separation 5.3 Soil & Waste Stacks, Stack Offsets, Branch Connections & Relief Vents
6 Chapter 6: Drainage Fittings, Cleanouts, Indirect Waste & Sumps
6.1 Drainage Fittings, Changes of Direction, Joints & Prohibited Connections 6.2 Cleanouts: Locations, Spacing, Size, Clearance & Access 6.3 Indirect Waste, Air Gaps, Air Breaks, Waste Receptors & Condensate Disposal 6.4 Sumps, Sewage Pumps, Ejectors & Backwater Valves
7 Chapter 7: Vent Systems & Sizing
7.1 Vent Purpose, Terminals, Outdoor Extensions & Vent Connections 7.2 Trap-to-Vent Distance (Table 909.1) & Vent Pipe Sizing (906) 7.3 Common Vents, Wet Venting & Waste Stack Vents 7.4 Circuit Venting, Combination Waste & Vent, Island, Single-Stack & Air Admittance Valves
8 Chapter 8: Water Supply, Distribution Sizing, Hot Water & Water Heaters
8.1 Water Service, Pipe Materials, Joints, Valves, Pressure Control & Disinfection 8.2 Water Distribution Design: Flow and Pressure Criteria, Fixture Supplies & Pipe Sizing 8.3 Hot Water Supply: Delivery Distance, Temperature Control, Recirculation & Thermal Expansion 8.4 Water Heaters: Installation, Relief Valves, Discharge Piping & Drain Pans
9 Chapter 9: Backflow Prevention & Cross-Connection Control
9.1 Cross-Connections, Backsiphonage, Backpressure & Degree of Hazard 9.2 Air Gaps, Atmospheric Vacuum Breakers & Hose Connection Protection 9.3 Testable Assemblies: RP, Double Check, PVB & SVB; Location, Testing & Virginia Certification 9.4 Protecting Specific Connections: Beverage Dispensers, Boilers, Sprinklers, Irrigation & Equipment
10 Chapter 10: Storm Drainage Systems & Sizing (with Virginia Amendments)
10.1 Storm Drainage Basics: Disposal, Materials, Rainfall Rates & Roof Area 10.2 Sizing Leaders, Conductors, Horizontal Storm Drains & Gutters (Virginia Tables) 10.3 Secondary (Emergency) Roof Drains, Scuppers & Roof Ponding 10.4 Subsoil Drains, Building Subdrains, Storm Sumps, Controlled-Flow Roofs & Continuous Flow
1.3 Standards of Practice: Designations, Address Changes & License Use
Key Takeaways Explain This Topic AI
Under 18VAC50-30-150, a regulant adds a trade designation by submitting a Board form with acceptable evidence of experience and, where applicable, an examination.
Adding a designation does not change the renewal date; renewal is based on the date the license was first issued (18VAC50-30-150 B).
Deleting the only trade or level designation on a license terminates the license (18VAC50-30-150 C).
Under 18VAC50-30-160, any change of address must be reported to the Board in writing within 30 days, and a post office box alone is not acceptable.
Under 18VAC50-30-170, no license or certification may be assigned or otherwise transferred.
Last updated: October 2026
Why Part IV matters on the exam
Standards of Practice is worth 3 items , more than any other regulatory area. The questions are usually short recall items with distractors that sound plausible: wrong deadlines, invented "pocket card" rules, or rules taken from the contractor regulations. The regulation itself is short, so learn its three sections exactly.
18VAC50-30-150: Adding or deleting trade designations
A Virginia tradesman license can carry more than one trade designation , for example plumbing (PLB) and gas fitting (GFC), each at the journeyman or master level.
Adding (subsection A): submit a Board form with acceptable evidence of experience, and an examination where applicable, for the designation sought. You must meet the general requirements of 18VAC50-30-30 and the qualifications of 18VAC50-30-39 for that designation.
Renewal date (subsection B): a license may have several designations, but its renewal date is based on the date the license was originally issued , not the date the newest designation was added.
Deleting (subsection C): to delete a designation, submit a signed statement listing it. If the license has only one trade or level designation, deleting it terminates the license .
The fee schedule in 18VAC50-30-90 lists $105 for an additional tradesman designation.
Example: A journeyman plumber licensed in March 2025 adds a journeyman gas fitter designation in June 2026. The license still expires at the end of March 2028, three years after the original issue month.
18VAC50-30-160: Change of address
Any change of address must be reported in writing to the Board within 30 days of the change. The Board is not responsible for a regulant's failure to receive notices or correspondence because of a failure to report a change of address. A post office box alone is not acceptable.
Points that are often tested:
The deadline is 30 days , not 10, 14 or 60 days, and not "at renewal."
The notice must be in writing ; a phone call does not satisfy the rule.
The address rule connects to renewal: 18VAC50-30-120 H says that not receiving a renewal notice does not relieve you of the duty to renew.
At application, 18VAC50-30-30 requires an address of record; a P.O. box works only with a physical address also on file.
18VAC50-30-170: No transfer
No license or certification issued by the Board may be assigned or otherwise transferred .
The license belongs to the individual who earned it. It cannot be sold, lent or reassigned to an employer, partner or helper. The conduct rules make the same point from another direction: 18VAC50-30-190 (8) prohibits allowing one's license or certification to be used by an unlicensed or uncertified individual , and aiding or abetting an unlicensed contractor.
Tradesman license versus contractor license
A tradesman license shows individual competence . Contracting is regulated separately under Article 1 of Chapter 11 and 18VAC50-22.
- Point Tradesman (18VAC50-30) Contractor (18VAC50-22)
- Who holds it An individual A firm (sole proprietor, LLC, corporation and so on)
- What it allows Performing plumbing work Bidding, contracting for and managing construction projects
- Threshold Not tied to contract value Required when a single contract or project is over $1,000
Contractor classes under § 54.1-1100:
- Class Single contract or project Total in any 12 months
- C Over $1,000 but less than $30,000 Less than $250,000
- B $30,000 or more but less than $150,000 $250,000 or more but less than $1 million
- A $150,000 or more $1 million or more
The same definition states that the Board requires a master tradesman license as a condition of licensure for electrical, plumbing and HVAC contractors. The DPOR tradesman application adds a practical warning: an applicant performing work over $1,000 must contact the Board to obtain a contractor license. This explains why 18VAC50-30-190 (6) addresses tradesmen who perform jobs under $1,000 : below that threshold, a licensed tradesman may contract directly without a contractor license, and still owes the duty to finish the job and handle the customer's money properly.
Permits connect the two licenses. Under VCC 108.4 and § 54.1-1111, a permit applicant must prove that they are licensed or certified under Chapter 11 to do the work, or file a written statement that they are not subject to licensure.
Supervision
The statute, not Part IV, governs supervision. § 54.1-1129 A says that an individual working under the supervision of a tradesman licensed in that specialty does not need a tradesman license. The tradesman regulations do not set an apprentice-to-journeyman ratio. Apprenticeship ratios come from registered apprenticeship standards, not from 18VAC50-30.