Study guide

2.2 Coagulation, Flocculation & Sedimentation Processes

Virginia Water/Wastewater Operator Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Virginia Licensing, Regulations & Administrative Standards

1.1 Virginia DPOR Board Structure, License Categories & Scope of Practice 1.2 Experience, Education, Substitutions & Examination Approval 1.3 Renewal, Reinstatement, CPE Requirements & Discipline 1.4 Virginia Drinking Water & Wastewater Environmental Governance 1.5 Facility Classification & Minimum Operator Attendance 1.6 The ABC/WPI Exam Blueprint, References & Test-Day Rules 1.7 License Maintenance, Reporting Duties & Professional Conduct

2 Chapter 2: Source Water & Drinking Water Treatment Unit Processes

2.1 Source Water Hydrology, Groundwater Protection & Raw Water Quality 2.2 Coagulation, Flocculation & Sedimentation Processes 2.3 Filtration Technologies & Media Management 2.4 Disinfection Chemistry, CT Calculations & Disinfection Byproducts 2.5 Corrosion Control, Softening & Fluoridation Chemistry 2.6 Pretreatment: Screening, Presedimentation, Aeration & Preoxidation 2.7 Filter Backwash, Surface Wash, Air Scour & Filter Surveillance 2.8 Membrane Systems: MF, UF, NF and RO Operation & Integrity Testing 2.9 Water Treatment Residuals: Handling, Thickening & Disposal 2.10 Chemical Feed Systems: Metering Pumps, Dry Feeders & Calibration 2.11 Process Monitoring, Trend Interpretation & Plant Optimization 2.12 Iron and Manganese, Taste-and-Odor Control, GAC & PFAS

3 Chapter 3: Wastewater Treatment, Biological Processes & Biosolids

3.1 Preliminary Treatment & Primary Clarification 3.2 Activated Sludge Dynamics & Secondary Process Control 3.3 Attached Growth Systems & Advanced Biological Processes 3.4 Biological & Chemical Nutrient Removal (BNR/ENR) 3.5 Solids Thickening, Digestion & Biosolids Management 3.6 Wastewater Characteristics, Influent Loading & Industrial Pretreatment 3.7 Secondary Clarifier Operation & Sludge Blanket Control 3.8 Lagoons, Stabilization Ponds & Natural Treatment Systems 3.9 Tertiary Filtration, Effluent Polishing & Water Reuse 3.10 Wastewater Disinfection & Dechlorination Systems 3.11 Aeration Systems, Blowers, Diffusers & Dissolved Oxygen Control 3.12 Digester Gas Handling, Cogeneration & Gas System Safety 3.13 Biosolids Land Application, Part 503 & Virginia Permitting

4 Chapter 4: Distribution Networks, Collection Systems & Hydraulic Systems

4.1 Water Distribution Networks, Storage & Pressure Management 4.2 Cross-Connection Control & Backflow Prevention Assemblies 4.3 Wastewater Collection Systems, Lift Stations & Inflow/Infiltration 4.4 Centrifugal & Positive Displacement Pumps 4.5 Motors, Drives, Control Systems & SCADA 4.6 Storage Tank Inspection, Meters, Services & Distribution Appurtenances 4.7 Main Disinfection, Flushing & Distribution Water Quality Management 4.8 Sewer Cleaning, CCTV Inspection & Collection System Rehabilitation 4.9 Maintenance Programs, Asset Management & Pump Efficiency Testing 4.10 Odor Control, Standby Power & Ancillary Plant Equipment

5 Chapter 5: Laboratory Analysis, Environmental Safety & Applied Math

5.1 Water & Wastewater Laboratory Analysis & QA/QC Protocols 5.2 Confined Space Entry, Chemical Safety & OSHA/VOSH Compliance 5.3 Hydraulic, Dosage & Pounds Formula Math 5.4 Wastewater Process & Loading Rate Mathematics 5.5 Drinking Water Microbiology & the Revised Total Coliform Rule 5.6 Wastewater Laboratory Analysis: Nutrients, Metals, WET & Regulatory Testing 5.7 Instrument Calibration, Online Analyzers & Data Validation 5.8 Process Control Testing: Jar Tests, Settleometer & Microscopic Examination 5.9 Chemical Receiving, Storage, Spill Response & Hazardous Waste 5.10 Electrical Safety, Fall Protection, Excavation & Traffic Control 5.11 PPE, Respiratory Protection & Biological Hazards 5.12 Advanced Applied Math: Mass Balance, Blending & Efficiency

6 Chapter 6: Regulatory Compliance, Reporting & Plant Administration

6.1 Safe Drinking Water Act Compliance: MCLs, Monitoring & Violations 6.2 Public Notification, Consumer Confidence Reports & Customer Complaints 6.3 VPDES Permit Compliance, DMRs & Overflow Reporting 6.4 Operating Records, Logbooks, Reports & Data Integrity 6.5 Emergency Response Planning & AWIA Risk and Resilience 6.6 Facility Security, SCADA Cybersecurity & Vulnerability Assessment 6.7 Budgeting, Procurement, Inventory & Capital Planning 6.8 Supervision, Training, SOP Development & Resource Optimization

2.2 Coagulation, Flocculation & Sedimentation Processes

Key Takeaways Explain This Topic AI

Natural colloidal particles maintain stability due to negative surface charges creating an electrical double layer, producing electrostatic repulsive forces measured as zeta potential (typically -15 to -30 mV).

Coagulation destabilizes colloids within 0.1 to 1.0 seconds via charge neutralization, electrical double-layer compression, inter-particle bridging, or sweep flocculation.

Standard aluminum sulfate (alum) hydrolysis consumes approximately 0.50 mg/L of natural alkalinity (as CaCO3) per 1.0 mg/L of alum dosed, driving pH downward if buffering is inadequate.

Rapid flash mixing requires intense shear velocity gradients (G > 700 s⁻¹ for 10-30 seconds), while flocculation demands tapered, gentle mixing (G decreasing from 50 to 20 s⁻¹ over 20-40 minutes) to prevent floc shear.

Sedimentation performance is governed by Surface Overflow Rate (SOR, typically 500-1,000 gpd/sq ft in conventional basins, up to 2,000-3,000 gpd/sq ft with inclined tube/plate settlers) and Weir Overflow Rate (WOR ≤ 20,000 gpd/ft).

Last updated: August 2026

Colloidal Chemistry & Electrokinetic Theory

Suspended matter in surface water consists of silt, clay, microorganisms, and natural organic matter (NOM) ranging in diameter from 0.001 μ m 0.001\,\mu\text{m} 0.001 μ m to 1.0 μ m 1.0\,\mu\text{m} 1.0 μ m . Because of their extremely small mass and high specific surface area, colloids remain in permanent suspension due to Brownian motion (thermal molecular bombardment) and do not settle under gravity (a 0.1 μ m 0.1\,\mu\text{m} 0.1 μ m colloidal clay particle requires over 20 years to settle 1 meter through quiescent water).

The Electrical Double Layer & Zeta Potential

In natural waters at neutral pH, colloidal surfaces carry a net negative electrical surface charge resulting from:

Isomorphous substitution of lower-valence metal ions within the mineral clay lattice.

Ionization of structural functional groups (carboxylic − COOH -\text{COOH} − COOH and phenolic − OH -\text{OH} − OH groups on humic/fulvic molecules).

Preferential adsorption of natural organic anions.

To balance this negative surface charge, waterborne cations orient themselves around each particle, establishing an Electrical Double Layer : Particle Surface (-) | Stern Layer (+) | Diffuse Layer (+ / -) | Bulk Solution (Neutral)

  • ==================== | =============== | ===================== | =======================
  • (-) | (+) | (+) (-) | (+) (-)
  • Fixed Negative | Fixed Cations | Dynamic Counter-Ions | Electrically Balanced
  • Surface Charge | (Adsorbed) | (Gradual Decay) | Water Matrix
  • | | |
  • |<-- Shear Plane / Slipping Plane -------->
  • | [Zeta Potential Measured Here] |

Stern Layer : A rigidly bound, immobile monolayer of positively charged counter-ions held tightly against the negative particle surface by electrostatic attraction.

Gouy-Chapman Diffuse Layer : A surrounding dynamic zone where positive counter-ions outnumber negative co-ions, with ion concentrations gradually equilibrating to the bulk solution.

Shear Plane (Slipping Plane) : The theoretical boundary separating ions moving with the hydrodynamic motion of the particle from the surrounding bulk fluid.

Zeta Potential ( ζ \zeta ζ ) : The electrical potential (measured in millivolts, mV \text{mV} mV ) existing at the shear plane. In raw natural water, zeta potential typically ranges from − 15 mV to − 30 mV -15\text{ mV to } -30\text{ mV} − 15 mV to − 30 mV .

According to DLVO Theory (Derjaguin, Landau, Verwey, and Overbeek), the stability of a colloidal suspension is determined by the net balance between two opposing forces:

Van der Waals Attractive Forces ( V A V_A V A ​ ) : Universal short-range intermolecular attractive forces.

Electrostatic Repulsive Forces ( V R V_R V R ​ ) : Long-range repulsive forces generated by overlapping diffuse electrical double layers of adjacent negative particles.

The net energy curve creates a repulsive Energy Barrier . The fundamental purpose of chemical coagulation is to destabilize the suspension by reducing the zeta potential toward the isoelectric point ( 0 mV 0\text{ mV} 0 mV , with optimal coagulation typically occurring between − 5 mV and + 3 mV -5\text{ mV and } +3\text{ mV} − 5 mV and + 3 mV ), suppressing the energy barrier and allowing attractive van der Waals forces to bond particles upon collision.

Coagulation Mechanisms & Primary Chemical Reactions

Chemical coagulation achieves colloidal destabilization through four primary mechanisms depending on coagulant type, dosage, and raw water pH:

Double-Layer Compression : High ionic strength compresses the diffuse electrical double layer, reducing the range of electrostatic repulsion.

Charge Neutralization (Adsorption-Destabilization) : Positively charged metal hydrolysis species or cationic polymers adsorb directly onto negative colloidal surfaces, neutralizing surface charges within 0.01 to 0.1 seconds 0.01\text{ to }0.1\text{ seconds} 0.01 to 0.1 seconds . Risk : Overdosing causes charge reversal (positive particle charge) and colloidal restabilization.

Enmeshment in Precipitate (Sweep Flocculation) : When metal coagulant is applied in concentrations exceeding the solubility limit of metal hydroxide, massive, sticky, amorphous precipitates ( A l ( O H ) 3 Al(OH)_3 A l ( O H ) 3 ​ or F e ( O H ) 3 Fe(OH)_3 F e ( O H ) 3 ​ ) form rapidly. As these precipitates drop through the water column, they physically trap and enmesh colloids. This is the dominant mechanism in low-turbidity, high-color waters.

Inter-Particle Polymer Bridging : Long-chain synthetic polymer molecules attach to multiple colloids simultaneously, forming a structural molecular matrix. [Colloid -] --- (Polymer Chain) --- [Colloid -] --- (Polymer Chain) --- [Colloid -]

Metal Coagulants & Alkalinity Consumption Stoichiometry

Primary coagulants are trivalent metal salts based on aluminum or iron.

1. Aluminum Sulfate (Alum): A l 2 ( S O 4 ) 3 ⋅ 14 H 2 O Al_2(SO_4)_3 \cdot 14H_2O A l 2 ​ ( S O 4 ​ ) 3 ​ ⋅ 14 H 2 ​ O

When standard dry or liquid commercial alum is added to water, it dissociates and hydrolyzes instantly through intermediate poly-nuclear species ( A l ( O H ) 2 + , A l 7 ( O H ) 17 4 + , A l 13 O 4 ( O H ) 24 7 + Al(OH)^{2+}, Al_7(OH)_{17}^{4+}, Al_{13}O_4(OH)_{24}^{7+} A l ( O H ) 2 + , A l 7 ​ ( O H ) 17 4 + ​ , A l 13 ​ O 4 ​ ( O H ) 24 7 + ​ ) into solid insoluble aluminum hydroxide: A l 2 ( S O 4 ) 3 ⋅ 14 H 2 O + 3 C a ( H C O 3 ) 2 → 2 A l ( O H ) 3 ↓ + 3 C a S O 4 + 6 C O 2 ↑ + 14 H 2 O Al_2(SO_4)_3 \cdot 14H_2O + 3Ca(HCO_3)_2 \rightarrow 2Al(OH)_3\downarrow + 3CaSO_4 + 6CO_2\uparrow + 14H_2O A l 2 ​ ( S O 4 ​ ) 3 ​ ⋅ 14 H 2 ​ O + 3 C a ( H C O 3 ​ ) 2 ​ → 2 A l ( O H ) 3 ​ ↓ + 3 C a S O 4 ​ + 6 C O 2 ​ ↑ + 14 H 2 ​ O

Optimal Coagulation pH : 5.8 to 7.5 5.8\text{ to }7.5 5.8 to 7.5

Alkalinity Consumption : Each 1.0 mg/L 1.0\text{ mg/L} 1.0 mg/L of commercial alum consumes approximately 0.50 mg/L 0.50\text{ mg/L} 0.50 mg/L of natural alkalinity as C a C O 3 CaCO_3 C a C O 3 ​ and releases free carbonic acid ( C O 2 CO_2 C O 2 ​ ).

If raw water total alkalinity is below 30 − 45 mg/L as C a C O 3 30-45\text{ mg/L as } CaCO_3 30 − 45 mg/L as C a C O 3 ​ , alum addition will depress the pH severely below the optimal precipitation range, leaving soluble aluminum residuals in finished water and creating highly corrosive conditions. Supplementary base ( hydrated lime C a ( O H ) 2 Ca(OH)_2 C a ( O H ) 2 ​ , soda ash N a 2 C O 3 Na_2CO_3 N a 2 ​ C O 3 ​ , or caustic soda N a O H NaOH N a O H ) must be dosed.

2. Ferric Chloride ( F e C l 3 FeCl_3 F e C l 3 ​ ) & Ferric Sulfate ( F e 2 ( S O 4 ) 3 Fe_2(SO_4)_3 F e 2 ​ ( S O 4 ​ ) 3 ​ )

Iron-based coagulants hydrolyze into dense, insoluble ferric hydroxide flocs: 2 F e C l 3 + 3 C a ( H C O 3 ) 2 → 2 F e ( O H ) 3 ↓ + 3 C a C l 2 + 6 C O 2 ↑ 2FeCl_3 + 3Ca(HCO_3)_2 \rightarrow 2Fe(OH)_3\downarrow + 3CaCl_2 + 6CO_2\uparrow 2 F e C l 3 ​ + 3 C a ( H C O 3 ​ ) 2 ​ → 2 F e ( O H ) 3 ​ ↓ + 3 C a C l 2 ​ + 6 C O 2 ​ ↑

Effective pH Range : Broad operating window ( 4.0 to 11.0 4.0\text{ to }11.0 4.0 to 11.0 ).

Alkalinity Consumption : 1.0 mg/L 1.0\text{ mg/L} 1.0 mg/L of F e C l 3 FeCl_3 F e C l 3 ​ consumes 0.92 mg/L 0.92\text{ mg/L} 0.92 mg/L of alkalinity as C a C O 3 CaCO_3 C a C O 3 ​ .

Operational Characteristics : Ferric floc is denser and settles faster than alum floc; highly effective in cold water ( < 4 ∘ C < 4^\circ\text{C} < 4 ∘ C ); excellent for heavy metals and arsenic removal; solutions are extremely acidic ( p H < 2 pH < 2 p H < 2 ) and corrosive to chemical feed lines.

3. Polyaluminum Chloride (PACl) & Aluminum Chlorohydrate (ACH)

Pre-polymerized aluminum salts ( A l n ( O H ) m C l 3 n − m Al_n(OH)_mCl_{3n-m} A l n ​ ( O H ) m ​ C l 3 n − m ​ ) are engineered with pre-hydrolyzed high-charge polymeric species:

Consume 50 % 50\% 50% to 80 % 80\% 80% less natural alkalinity than alum.

Perform exceptionally well in cold raw waters without requiring pH adjustment.

Generate smaller, denser sludge volumes with lower residual dissolved aluminum carryover.

4. Coagulant Aids & Flocculant Polymers

Cationic Polymers (e.g., PolyDADMAC): High positive charge density, low-to-medium molecular weight; used as primary coagulants or coagulant aids for charge neutralization, reducing required metal coagulant dose.

Anionic Polymers (hydrolyzed polyacrylamides): High molecular weight, negative charge; used in the flocculation stage to form broad inter-particle bridges in moderate-to-high turbidity waters.

Nonionic Polymers : Neutral polyacrylamides used as filter aids to increase floc shear resistance across granular media beds.

  • Flash (Rapid) Mixing & Flocculation Dynamics Raw Water + Coagulant
  • ========================> [ FLASH MIX ] ================> [ FLOC CHAMBER 1 ] ===>
  • G > 700 s^-1 G = 50-70 s^-1
  • Time = 10-30 sec (Rapid Collisions)
  • |
  • ===> [ FLOC CHAMBER 2 ] ===> [ FLOC CHAMBER 3 ] ================> [ SEDIMENTATION BASIN ]
  • G = 30-40 s^-1 G = 15-25 s^-1 Quiescent Settling
  • (Floc Growth) (Prevent Floc Shear) SOR: 500-1000 gpd/sq ft
  • Rapid Flash Mixing Mechanics

Because charge neutralization reactions occur in less than 0.1 second 0.1\text{ second} 0.1 second , the coagulant chemical must be dispersed instantaneously throughout the raw water stream before metal hydrolysis precipitates form.

Mechanisms : In-line static mixers, high-speed mechanical turbine impellers, pumped chemical diffusion quills, or hydraulic jumps in flumes.

Velocity Gradient ( G G G ) : The mathematical measure of mixing intensity (shear rate in s − 1 \text{s}^{-1} s − 1 ): G = P μ ⋅ V G = \sqrt{\frac{P}{\mu \cdot V}} G = μ ⋅ V P ​ ​

Where P P P is power dissipated in the fluid ( ft ⋅ lb/s \text{ft}\cdot\text{lb/s} ft ⋅ lb/s or Watts \text{Watts} Watts ), μ \mu μ is dynamic fluid viscosity ( lb ⋅ s/ft 2 \text{lb}\cdot\text{s/ft}^2 lb ⋅ s/ft 2 or Pa ⋅ s \text{Pa}\cdot\text{s} Pa ⋅ s ), and V V V is basin volume ( ft 3 \text{ft}^3 ft 3 or m 3 \text{m}^3 m 3 ).

Flash Mix Design Standards :

  • Velocity Gradient: G > 700 to 1000 s − 1 G > 700\text{ to }1000\text{ s}^{-1} G > 700 to 1000 s − 1
  • Detention Time ( t t t ): 10 to 30 seconds 10\text{ to }30\text{ seconds} 10 to 30 seconds

Mixing Product ( G t Gt Gt ): 10 , 000 to 30 , 000 10,000\text{ to }30,000 10 , 000 to 30 , 000 (dimensionless)

Tapered Flocculation Design

Flocculation provides gentle, prolonged agitation to promote collisions among destabilized microflocs, agglomerating them into large, dense, settleable macroflocs (pinfloc growing to 1 − 3 mm 1-3\text{ mm} 1 − 3 mm flocs).

If mixing intensity is too low, particles will not collide; if mixing intensity is too high, the hydraulic shear forces exceed the structural tensile strength of the floc, causing floc shear (breakup) .

To optimize kinetics, plants utilize Tapered Flocculation across a minimum of 3 compartmentalized stages:

Stage 1 : G = 50 to 70 s − 1 G = 50\text{ to }70\text{ s}^{-1} G = 50 to 70 s − 1 (High initial collision frequency)

Stage 2 : G = 30 to 40 s − 1 G = 30\text{ to }40\text{ s}^{-1} G = 30 to 40 s − 1 (Floc aggregation and densification)

Stage 3 : G = 15 to 25 s − 1 G = 15\text{ to }25\text{ s}^{-1} G = 15 to 25 s − 1 (Gentle transport preventing shear)

Detention Time : 20 to 40 minutes 20\text{ to }40\text{ minutes} 20 to 40 minutes total retention time.

Camp Number ( G t Gt Gt ) : 20 , 000 to 100 , 000 20,000\text{ to }100,000 20 , 000 to 100 , 000 .

Equipment : Horizontal paddle-wheel flocculators with variable frequency drives (VFDs) or vertical hydrofoil axial turbines separated by baffled dividing walls (orifice velocity 0.5 to 1.5 fps 0.5\text{ to }1.5\text{ fps} 0.5 to 1.5 fps ) to eliminate hydraulic short-circuiting.

Sedimentation Basin Hydraulics & Clarifier Typologies

Sedimentation is the physical separation process where aggregated floc settles to the basin floor under gravitational acceleration, producing a clarified supernatant for filtration.

Hazen Theory & Hydraulic Loading Metrics

According to Hazen's sedimentation theory, the removal of unhindered settling particles in a horizontal flow clarifier depends entirely on the basin surface area ( A s A_s A s ​ ) and volumetric flow rate ( Q Q Q ) , completely independent of water depth or detention time. A particle is completely removed if its settling velocity ( v s v_s v s ​ ) equals or exceeds the basin's Surface Overflow Rate ( S O R SOR SOR ) : S O R = Plant Flow Rate ( Q ) Basin Surface Area ( A s ) = gal/day ft 2 ( or gpm ft 2 ) SOR = \frac{\text{Plant Flow Rate } (Q)}{\text{Basin Surface Area } (A_s)} = \frac{\text{gal/day}}{\text{ft}^2} \quad \left(\text{or } \frac{\text{gpm}}{\text{ft}^2}\right) SOR = Basin Surface Area ( A s ​ ) Plant Flow Rate ( Q ) ​ = ft 2 gal/day ​ ( or ft 2 gpm ​ ) Weir Overflow Rate ( W O R ) = Plant Flow Rate ( Q ) Total Effluent Weir Length ( L weir ) = gal/day linear ft \text{Weir Overflow Rate } (WOR) = \frac{\text{Plant Flow Rate } (Q)}{\text{Total Effluent Weir Length } (L_{\text{weir}})} = \frac{\text{gal/day}}{\text{linear ft}} Weir Overflow Rate ( W OR ) = Total Effluent Weir Length ( L weir ​ ) Plant Flow Rate ( Q ) ​ = linear ft gal/day ​ Detention Time ( D T ) = Basin Volume ( V ) Flow Rate ( Q ) = Gallons × 24 hr/day Flow (gpd) \text{Detention Time } (DT) = \frac{\text{Basin Volume } (V)}{\text{Flow Rate } (Q)} = \frac{\text{Gallons} \times 24\text{ hr/day}}{\text{Flow (gpd)}} Detention Time ( D T ) = Flow Rate ( Q ) Basin Volume ( V ) ​ = Flow (gpd) Gallons × 24 hr/day ​

Clarifier Classifications

Conventional Rectangular Basins : Long basins with length-to-width ratios ≥ 4 : 1 \ge 4:1 ≥ 4 : 1 and depths of 10 − 15 ft 10-15\text{ ft} 10 − 15 ft . Feature 4 functional zones: Inlet (perforated target baffle to distribute flow evenly), Settling zone, Sludge collection zone (bottom flight scrapers), and Outlet zone (submerged launders with adjustable V-notch weir plates). Detention time: 2 − 4 hours 2-4\text{ hours} 2 − 4 hours ; S O R : 500 − 1000 gpd/sq ft SOR: 500-1000\text{ gpd/sq ft} SOR : 500 − 1000 gpd/sq ft .

Circular Center-Feed Clarifiers : Radial flow outwardly directed from a central energy-dissipating feed well toward a peripheral effluent launder. Equipped with rotating bottom rake scrapers.

Upflow Solids-Contact Clarifiers : Single compact vessels integrating rapid mix, reaction flocculation, and high-density sludge blanket filtration. Influent raw water is forced upward through a dynamic suspended bed of previously formed sludge flocs, accelerating particle contact and achieving S O R SOR SOR values of 1000 − 1500 gpd/sq ft 1000-1500\text{ gpd/sq ft} 1000 − 1500 gpd/sq ft .

High-Rate Inclined Settlers (Tube & Plate Settlers) : Modules of PVC tubes inclined at a 60 ∘ 60^\circ 6 0 ∘ angle (or parallel Lamella plates). The 60 ∘ 60^\circ 6 0 ∘ inclination makes the surfaces self-cleaning (sludge slides down continuously into the hopper). The effective settling depth is reduced from 12 feet 12\text{ feet} 12 feet to 2 inches 2\text{ inches} 2 inches , drastically shrinking required basin footprint and allowing S O R SOR SOR loading rates of 1500 to 3000 gpd/sq ft 1500\text{ to }3000\text{ gpd/sq ft} 1500 to 3000 gpd/sq ft .

Jar Testing Protocol & Coagulation Optimization

The laboratory Jar Test is the standard operational procedure for establishing optimal coagulant type, chemical dose, coagulant aid concentration, and target coagulation pH. [Jar 1: 10 mg/L] [Jar 2: 20 mg/L] [Jar 3: 30 mg/L] [Jar 4: 40 mg/L] [Jar 5: 50 mg/L] [Jar 6: Control]

  • -----------------------------------------------------------------------------------------------------
  • 1. Rapid Mix: 100-300 RPM for 1.0 minute (Simulates Flash Mix)
  • 2. Flocculation: Tapered 40 -> 25 -> 15 RPM for 20 minutes (Simulates 3-Stage Floc)
  • 3. Settle: 0 RPM for 15-30 minutes (Simulates Clarifier)
  • 4. Evaluate: Measure Supernatant Turbidity (NTU), Final pH, TOC/UV-254, and Floc Size/Rate
  • Step-by-Step Jar Test Procedure

Collect a fresh representative raw water sample and immediately measure temperature, pH, turbidity, and alkalinity.

Fill six 2-liter square B-Ker (anti-vortex) jars with 2000 mL 2000\text{ mL} 2000 mL of sample each.

Add variable, graduated doses of primary coagulant (e.g., 10 , 20 , 30 , 40 , 50 mg/L 10, 20, 30, 40, 50\text{ mg/L} 10 , 20 , 30 , 40 , 50 mg/L ) across the jars simultaneously while running.

Flash Mix : Run gang stirrers at high speed ( 100 to 300 rpm 100\text{ to }300\text{ rpm} 100 to 300 rpm ) for 1.0 minute 1.0\text{ minute} 1.0 minute .

Flocculation : Reduce stirrer speeds to simulate plant hydraulics: 40 rpm 40\text{ rpm} 40 rpm for 10 min 10\text{ min} 10 min , 25 rpm 25\text{ rpm} 25 rpm for 10 min 10\text{ min} 10 min , and 15 rpm 15\text{ rpm} 15 rpm for 5 min 5\text{ min} 5 min . Record time to initial visible pinfloc formation.

Settling : Stop stirrers and allow quiescent settling for 15 to 30 minutes 15\text{ to }30\text{ minutes} 15 to 30 minutes . Record floc settling velocity ( % settled per minute \%\text{ settled per minute} % settled per minute ) and sludge compaction volume.

Analysis : Extract supernatant samples from the sampling ports ( 2 inches 2\text{ inches} 2 inches below surface) and analyze for: residual turbidity (NTU), true color (PCU), UV-254 absorbance / TOC, residual dissolved aluminum/iron, and final pH.

Selection : The optimal dose is the lowest chemical quantity that achieves target turbidity removal, maximum TOC/UV-254 reduction, robust settling velocity, and acceptable final pH without chemical overdosing.

Loading diagram... Coagulation, Flocculation & Sedimentation Unit Processes