Study guide

2.12 Iron and Manganese, Taste-and-Odor Control, GAC & PFAS

Virginia Water/Wastewater Operator Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Virginia Licensing, Regulations & Administrative Standards

1.1 Virginia DPOR Board Structure, License Categories & Scope of Practice 1.2 Experience, Education, Substitutions & Examination Approval 1.3 Renewal, Reinstatement, CPE Requirements & Discipline 1.4 Virginia Drinking Water & Wastewater Environmental Governance 1.5 Facility Classification & Minimum Operator Attendance 1.6 The ABC/WPI Exam Blueprint, References & Test-Day Rules 1.7 License Maintenance, Reporting Duties & Professional Conduct

2 Chapter 2: Source Water & Drinking Water Treatment Unit Processes

2.1 Source Water Hydrology, Groundwater Protection & Raw Water Quality 2.2 Coagulation, Flocculation & Sedimentation Processes 2.3 Filtration Technologies & Media Management 2.4 Disinfection Chemistry, CT Calculations & Disinfection Byproducts 2.5 Corrosion Control, Softening & Fluoridation Chemistry 2.6 Pretreatment: Screening, Presedimentation, Aeration & Preoxidation 2.7 Filter Backwash, Surface Wash, Air Scour & Filter Surveillance 2.8 Membrane Systems: MF, UF, NF and RO Operation & Integrity Testing 2.9 Water Treatment Residuals: Handling, Thickening & Disposal 2.10 Chemical Feed Systems: Metering Pumps, Dry Feeders & Calibration 2.11 Process Monitoring, Trend Interpretation & Plant Optimization 2.12 Iron and Manganese, Taste-and-Odor Control, GAC & PFAS

3 Chapter 3: Wastewater Treatment, Biological Processes & Biosolids

3.1 Preliminary Treatment & Primary Clarification 3.2 Activated Sludge Dynamics & Secondary Process Control 3.3 Attached Growth Systems & Advanced Biological Processes 3.4 Biological & Chemical Nutrient Removal (BNR/ENR) 3.5 Solids Thickening, Digestion & Biosolids Management 3.6 Wastewater Characteristics, Influent Loading & Industrial Pretreatment 3.7 Secondary Clarifier Operation & Sludge Blanket Control 3.8 Lagoons, Stabilization Ponds & Natural Treatment Systems 3.9 Tertiary Filtration, Effluent Polishing & Water Reuse 3.10 Wastewater Disinfection & Dechlorination Systems 3.11 Aeration Systems, Blowers, Diffusers & Dissolved Oxygen Control 3.12 Digester Gas Handling, Cogeneration & Gas System Safety 3.13 Biosolids Land Application, Part 503 & Virginia Permitting

4 Chapter 4: Distribution Networks, Collection Systems & Hydraulic Systems

4.1 Water Distribution Networks, Storage & Pressure Management 4.2 Cross-Connection Control & Backflow Prevention Assemblies 4.3 Wastewater Collection Systems, Lift Stations & Inflow/Infiltration 4.4 Centrifugal & Positive Displacement Pumps 4.5 Motors, Drives, Control Systems & SCADA 4.6 Storage Tank Inspection, Meters, Services & Distribution Appurtenances 4.7 Main Disinfection, Flushing & Distribution Water Quality Management 4.8 Sewer Cleaning, CCTV Inspection & Collection System Rehabilitation 4.9 Maintenance Programs, Asset Management & Pump Efficiency Testing 4.10 Odor Control, Standby Power & Ancillary Plant Equipment

5 Chapter 5: Laboratory Analysis, Environmental Safety & Applied Math

5.1 Water & Wastewater Laboratory Analysis & QA/QC Protocols 5.2 Confined Space Entry, Chemical Safety & OSHA/VOSH Compliance 5.3 Hydraulic, Dosage & Pounds Formula Math 5.4 Wastewater Process & Loading Rate Mathematics 5.5 Drinking Water Microbiology & the Revised Total Coliform Rule 5.6 Wastewater Laboratory Analysis: Nutrients, Metals, WET & Regulatory Testing 5.7 Instrument Calibration, Online Analyzers & Data Validation 5.8 Process Control Testing: Jar Tests, Settleometer & Microscopic Examination 5.9 Chemical Receiving, Storage, Spill Response & Hazardous Waste 5.10 Electrical Safety, Fall Protection, Excavation & Traffic Control 5.11 PPE, Respiratory Protection & Biological Hazards 5.12 Advanced Applied Math: Mass Balance, Blending & Efficiency

6 Chapter 6: Regulatory Compliance, Reporting & Plant Administration

6.1 Safe Drinking Water Act Compliance: MCLs, Monitoring & Violations 6.2 Public Notification, Consumer Confidence Reports & Customer Complaints 6.3 VPDES Permit Compliance, DMRs & Overflow Reporting 6.4 Operating Records, Logbooks, Reports & Data Integrity 6.5 Emergency Response Planning & AWIA Risk and Resilience 6.6 Facility Security, SCADA Cybersecurity & Vulnerability Assessment 6.7 Budgeting, Procurement, Inventory & Capital Planning 6.8 Supervision, Training, SOP Development & Resource Optimization

2.12 Iron and Manganese, Taste-and-Odor Control, GAC & PFAS

Key Takeaways Explain This Topic AI

Iron and manganese are secondary contaminants at 0.3 mg/L and 0.05 mg/L respectively, but customer complaints usually begin well below those levels.

Manganese oxidizes far more slowly than iron with free chlorine at normal pH, which is why permanganate, chlorine dioxide, ozone, or catalytic media is used instead.

Sequestration with polyphosphate holds iron and manganese in solution but does not remove them, works only up to roughly 1 mg/L combined, and fails when the water is heated.

Geosmin and MIB are detectable by human senses at concentrations below 10 nanograms per liter and are best removed with activated carbon or ozone rather than by conventional coagulation.

EPA finalized enforceable maximum contaminant levels for PFOA and PFOS at 4.0 nanograms per liter in April 2024, and granular activated carbon, ion exchange, and reverse osmosis are the recognized removal technologies.

Last updated: August 2026

Iron and Manganese, Taste-and-Odor Control, GAC & PFAS

The ABC Water Treatment outline names "iron/manganese treatment" under Treatment Process, "activated carbon contactors" among the technologies that drive Virginia's waterworks classification, and "emerging contaminants (e.g., microplastics, PFAS)" as an analysis the operator must be able to perform, record, and interpret.

  • 1. Iron and Manganese
  • Why they matter

Neither is a health risk at the concentrations found in most water supplies. Both are secondary contaminants regulated for aesthetic reasons:

  • Contaminant Secondary MCL Symptom
  • Iron 0.3 mg/L Red-brown staining, metallic taste, red water complaints
  • Manganese 0.05 mg/L Black staining, bitter taste, black water and black particles

Complaints typically begin below the SMCL - manganese at 0.02 mg/L will stain laundry over time, and manganese deposits accumulate in mains for years before a flow disturbance releases them all at once as black water.

Where they come from

Anoxic groundwater - reduced Fe2+ and Mn2+ are soluble and colorless. The water is clear at the tap and turns red or black in the sink as it oxidizes.

Reservoir hypolimnion during summer stratification - the same reduction chemistry, then delivered to the plant intake at turnover.

Oxidation rates - the key operational difference

  • Oxidant Iron (Fe2+) Manganese (Mn2+)
  • Oxygen (aeration) Fast above pH 7 Impractically slow below pH 9.5
  • Free chlorine Fast, seconds Slow below pH 8 ; hours at pH 7
  • Potassium permanganate Fast Fast , minutes, across normal pH
  • Chlorine dioxide Fast Fast across a wide pH range
  • Ozone Very fast Very fast - but overdose oxidizes Mn to permanganate , producing pink water

Stoichiometry worth remembering: roughly 1 mg/L KMnO4 per 1 mg/L Fe and roughly 2 mg/L KMnO4 per 1 mg/L Mn . Chlorine requires about 0.62 mg/L per mg/L Fe and about 1.3 mg/L per mg/L Mn.

Treatment options

Oxidation and filtration. Oxidize to insoluble Fe(OH)3 or MnO2, allow adequate reaction time in a detention basin, then filter. The most common approach and the most robust.

Manganese greensand or catalytic media. Glauconite or engineered media coated with manganese dioxide catalyzes oxidation on the grain surface. Operated either continuously regenerated (a low permanganate or chlorine dose fed ahead of the filter) or intermittently regenerated (batch permanganate soak). The classic failure is the pink water breakthrough that follows an intermittent regeneration that was not fully rinsed.

Sequestration. Polyphosphate or silicate binds Fe and Mn as a soluble complex so it never precipitates.

It does not remove anything. The metal is still in the water delivered to the customer.

Practical limit is roughly 1 mg/L combined Fe plus Mn ; above that, sequestration fails.

The complex breaks down on heating , so the water discolors in a water heater or a kettle even though it is clear at the tap.

Polyphosphate must be applied before any oxidant, or the metal oxidizes first and cannot be sequestered.

Polyphosphate can also mobilize lead deposits, so it must be evaluated against corrosion control objectives.

Ion exchange or lime softening - both remove iron and manganese incidentally, but iron fouls cation resin badly unless the water is truly anoxic.

Biological filtration - engineered filters cultivating Gallionella and Leptothrix to oxidize iron and manganese, used in Europe and increasingly in North America.

  • 2. Taste and Odor
  • The dominant compounds

Geosmin - earthy, musty. Produced by cyanobacteria and actinomycetes.

2-methylisoborneol (MIB) - musty, camphor. Same producers.

Human detection thresholds are approximately 4 to 10 nanograms per liter (parts per trillion) , which is one thousandth of the concentration at which most contaminants are even measurable in a plant lab. Complaints therefore arrive long before routine analysis flags anything.

Other taste-and-odor sources: hydrogen sulfide (rotten egg, groundwater), chlorophenols (medicinal, from chlorine reacting with phenolic industrial discharge), decaying vegetation (grassy, swampy), and chloramine off-flavors .

Treatment

  • Method Effectiveness on geosmin/MIB Notes
  • Conventional coagulation Poor - these are dissolved, not particulate Do not expect help
  • Free chlorine Poor, and may worsen taste by forming chlorophenols Not a solution

Powdered activated carbon (PAC) Good, 5 to 30 mg/L Must be added early with contact time, and before any oxidant

  • Granular activated carbon (GAC) Very good Continuous, no daily handling; capital cost
  • Ozone Very good Also destroys color and some organics; produces bromate risk
  • Ozone plus biofiltration Excellent The current best-practice combination
  • Reservoir management Preventive Multi-level intake, destratification, nutrient control

PAC application rules: apply as far upstream as contact time allows (presedimentation or rapid mix), never simultaneously with chlorine or permanganate (the carbon consumes the oxidant and the oxidant is wasted), and expect PAC to increase sludge volume and to darken filter backwash.

3. Activated Carbon Fundamentals

Activated carbon works by physical adsorption onto an enormous internal surface area - 500 to 1,500 square meters per gram .

  • PAC GAC
  • Particle size Under 0.1 mm (powder) 0.6 to 2.4 mm (granular)

Application Dosed as a slurry, removed with the sludge Fixed bed, either as a filter medium (filter-adsorber) or a separate post-filter contactor

  • Dose / design basis mg/L Empty bed contact time (EBCT) , typically 10 to 20 minutes
  • Cost profile Low capital, high recurring High capital, low recurring
  • Best for Seasonal, episodic events Continuous, year-round loading

Empty bed contact time = (Bed volume) / (Flow rate). A 500 cubic foot bed at 250 cubic feet per minute has an EBCT of 2 minutes - far too short for organics removal.

Exhaustion and breakthrough. A GAC bed does not fail suddenly; a mass-transfer zone migrates down the bed until the target compound appears in the effluent. Two operational consequences:

Monitor the effluent , not the calendar. Bed life varies enormously with loading.

Competitive adsorption means a strongly adsorbed compound can displace a weakly adsorbed one already on the carbon, so effluent concentration can briefly exceed influent concentration - a phenomenon called chromatographic peaking.

GAC beds are warm, wet, and organic-rich, so they support biological growth . That is a benefit in intentional biofiltration and a problem if it produces heterotrophic plate count increases downstream.

Spent GAC is either reactivated thermally off site or landfilled. Reactivation loses about 5 to 10 percent of the carbon per cycle.

4. PFAS

Per- and polyfluoroalkyl substances are synthetic fluorinated compounds used in firefighting foam, non-stick and stain-resistant coatings, and many industrial processes. The carbon-fluorine bond makes them extremely persistent - hence "forever chemicals."

The current federal standards

In April 2024 EPA finalized the first enforceable National Primary Drinking Water Regulation for PFAS:

  • Compound MCL
  • PFOA 4.0 ng/L (parts per trillion)
  • PFOS 4.0 ng/L
  • PFHxS 10 ng/L
  • PFNA 10 ng/L
  • HFPO-DA (GenX chemicals) 10 ng/L
  • Mixtures of PFHxS, PFNA, HFPO-DA, and PFBS Hazard Index of 1 (unitless)

Systems must complete initial monitoring and, where levels exceed the standards, install treatment. Note that PFOA and PFOS also carry MCLGs of zero , reflecting the absence of an identified safe threshold.

What works and what does not

Technology PFAS removal Notes

Granular activated carbon Effective, especially for long-chain PFOA and PFOS Short-chain compounds break through much sooner; competitive adsorption from background TOC shortens bed life dramatically

Anion exchange resin Effective, generally longer run times than GAC PFAS are anionic; single-use resin is common because regeneration produces a difficult brine

Reverse osmosis / nanofiltration Highly effective, over 90 percent for most PFAS Produces a concentrate stream that still contains the PFAS and must be managed

Conventional coagulation, sedimentation, filtration Essentially no removal PFAS are dissolved and not adsorbed to floc

Air stripping No removal PFAS are not volatile

Oxidation - chlorine, ozone, permanganate, UV No destruction The carbon-fluorine bond is not broken by conventional oxidants; oxidation of precursors can actually increase measured PFOA and PFOS

That last row is the exam-relevant trap. Adding more chlorine or ozone does nothing for PFAS, and oxidizing polyfluorinated precursors can convert them into the very perfluorinated compounds being measured.

Analysis

PFAS are measured at parts per trillion by liquid chromatography with tandem mass spectrometry - EPA Methods 533 and 537.1 . Sampling requires PFAS-free field practice: no PTFE-lined caps, no waterproof field clothing, no adhesive notes, no fast-food wrappers, and specified bottle types. Contamination during sampling is the most common cause of a false positive.

Microplastics

Also listed in the ABC criteria as an emerging contaminant. There is currently no federal MCL for microplastics in drinking water and no standardized regulatory analytical method . Conventional coagulation, sedimentation, and filtration remove a substantial fraction of larger particles, and membranes remove more, but operators should describe the status accurately: monitored and researched, not regulated.