Study guide
13.5 Civil Penalties, Appeals, Exam Rules & Certificate Discipline
Washington Journeyman Electrician 01 General Journey Level
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Exam Structure & Open-Book Code Navigation
1.1 Washington 01 Electrician Licensing Pathway & Exam Structure 1.2 National Electrical Code Architecture & Fast Lookup Strategies 1.3 Open-Book Exam Rules, Reference Preparation & Pacing
2 Chapter 2: Electrical Theory & Fundamental Math
2.1 Ohm's Law, Joule's Law & Circuit Analysis 2.2 AC Fundamentals, Reactance & Power Factor 2.3 Three-Phase Power Calculations: Wye & Delta Configurations
3 Chapter 3: General Installation Requirements & Conductor Sizing
3.1 Installation Requirements & Working Space Clearances 3.2 Conductor Sizing & Table 310.16 Ampacity 3.3 Temperature Correction Factors & Raceway Derating
4 Chapter 4: Wiring Methods, Raceways & Enclosure Calculations
4.1 Common Wiring Methods & Cable Assemblies 4.2 Conduit & Tubing Installation and Fill Calculations 4.3 Box Fill & Pull Box Sizing Calculations 4.4 Flexible Raceways, ENT, Wireways, Cable Trays, Specialty Cables & Plenum Rules
5 Chapter 5: Branch Circuits, Feeders & Overcurrent Protection
5.1 Branch Circuit Ratings, Receptacle Placement & Lighting 5.2 GFCI, AFCI & Special Protection Requirements 5.3 Overcurrent Protection & Feeder Tap Rules 5.4 Grounded Conductors, Feeders, Outside Circuits & Surge Protection (Articles 200, 215, 225, 280, 285) 5.5 Overcurrent Device Location, Fuses, Circuit Breakers & Transformer Secondary Conductors (Article 240)
6 Chapter 6: Grounding & Bonding (Article 250)
6.1 Grounding vs. Bonding: Core Principles & Definitions 6.2 Grounding Electrode Systems & GEC Sizing 6.3 Main Bonding Jumpers & Equipment Grounding Conductor Sizing
7 Chapter 7: Services, Feeders & Load Calculations
7.1 Electrical Services & Service Equipment (Article 230) 7.2 Dwelling Unit Load Calculations: Standard & Optional Methods 7.3 Commercial Load Calculations & Voltage Drop
8 Chapter 8: Equipment for General Use & Equipment Over 1000 Volts (Articles 400-490)
8.1 Flexible Cords, Fixture Wires, Switches, Receptacles & Panelboards (Articles 400-408) 8.2 Luminaires, Appliances, Space Heating & Other Equipment (Articles 410-427, 455-480) 8.3 Equipment Over 1000 Volts (Article 490 and Related Rules)
9 Chapter 9: Motors, HVAC Equipment, Generators & Transformers (Articles 430-450)
9.1 Motor Branch Circuit Conductor Sizing & Overloads 9.2 Motor Short-Circuit Protection & Disconnecting Means 9.3 Transformers, Generators & Hermetic HVAC Equipment
10 Chapter 10: Hazardous Locations & Special Occupancies (Articles 500-590)
10.1 Hazardous (Classified) Locations (Articles 500–516) 10.2 Health Care Facilities, Places of Assembly & Theaters (Articles 517-540) 10.3 Agricultural Buildings, Mobile Homes, RV Parks, Marinas & Temporary Installations (Articles 545-590)
11 Chapter 11: Special Equipment (Articles 600-695)
11.1 Signs, Cranes, Elevators, EV Charging, Welders, IT Rooms & Industrial Machinery (Articles 600-670) 11.2 Swimming Pools, Spas, Hot Tubs & Fountains (Article 680) 11.3 Solar Photovoltaic Systems, Fuel Cells, Wind & Fire Pumps (Articles 690-695)
12 Chapter 12: Emergency Systems, Special Conditions & Communications (Articles 700-830)
12.1 Emergency, Legally Required & Optional Standby Systems (Articles 700-702) 12.2 Interconnected Power Sources, Energy Storage, Power-Limited Circuits, Fire Alarm & Communications (Articles 705-830)
13 Chapter 13: Washington Electrical Laws & Administrative Code (RCW 19.28 & WAC 296-46B)
13.1 Certificates of Competency, Specialty Scopes & Renewal 13.2 Trainees, Supervision Ratios, Apprenticeship & Qualifying Experience 13.3 Electrical Contractors, Administrators, Bonds & Exemptions 13.4 Permits, Inspections, Class A & Class B Work, and Plan Review 13.5 Civil Penalties, Appeals, Exam Rules & Certificate Discipline 13.6 WAC 296-46B Amendments: Adoption, General Rules, Services, Grounding & Wiring (NEC Chapters 1-4) 13.7 WAC 296-46B Amendments: Special Occupancies, Special Equipment, Emergency Systems & Communications (NEC Chapters 5-8)
13.5 Civil Penalties, Appeals, Exam Rules & Certificate Discipline
Key Takeaways Explain This Topic AI
Penalties for violating the licensing and installation sections range from $50 to $10,000; violations of the certification sections range from $50 to $500 (RCW 19.28.131, 19.28.271).
Each day a violation occurs can be a separate offense, and a repeat within three years of a final judgment is charged as a second or later offense (WAC 296-46B-915).
A penalty may be appealed to the Electrical Board by filing a written notice with L&I within 20 days after notice, with a certified check for $200 or 10 percent of the penalty, whichever is less but not under $100 (RCW 19.28.131).
The Electrical Board has 15 members appointed by the governor for four-year terms (RCW 19.28.311).
Exam rules: 70 percent on each section, a one-year exam period, a two-week wait after a failure, and a three-month wait after failing a part three times in a year (WAC 296-46B-960).
Last updated: September 2026
Why this section matters
The WA Codes section asks about the consequences of breaking the rules as well as the rules themselves. You also need the exam rules to plan your own testing, since WAC 296-46B-960 controls what you may bring and how retests work.
Statutory penalty ranges
Statute Covers Range
RCW 19.28.131 Licensing, installation, and inspection provisions (RCW 19.28.010-.141 and .311-.361) $50 to $10,000 per violation
RCW 19.28.271 Certification provisions (RCW 19.28.161-.271): employing uncertified workers, working without a certificate $50 to $500 per violation
RCW 19.28.271(1) makes it unlawful to employ someone without a certificate of competency, temporary permit, or training certificate, and unlawful for an individual to do electrical work without one of those documents and photo identification in his or her possession. Equipment installed by an uncertified person may not receive a permit or a service connection.
The civil penalty schedule (WAC 296-46B-915)
- Violation 1st 2nd Each later
- Unlicensed contracting (electrical or telecommunications) $1,000 $2,000 $3,000, then $10,000
- Employing a person without a valid certificate or training certificate $250 $500 $500
- Failing to visibly display a (valid) certificate $50 $100 $100
- Working without a valid certificate, or outside its scope $250 $500 $500
- Improper ratio of electricians to trainees $250 $500 $500
- Failing to supervise a trainee properly $250 $500 $500
- Working as a trainee without proper supervision $50 $250 $500
- Work outside the scope of a specialty contractor license $500 $1,500 $3,000, then $6,000
- Selling unlisted spa, hot tub, pool, or hydromassage equipment $500 $1,000 $2,000
- Covering or concealing work before inspection $250 $1,000 $2,000
- Not making corrections within 15 days $250 $1,000 $2,000
- No permit (or provisional label) or inspection before starting work $250 $1,000 $2,000
Rules that apply across the schedule:
Each day a violation occurs on a job site may be a separate offense.
Once a violation becomes a final judgment, any additional violation within three years is a second or later offense.
For serious noncompliance or violations, L&I may double the penalty, up to $10,000.
The owner emergency-repair exception: no permit penalty if the permit is obtained and posted by the next business day after the emergency repair began.
A contractor cited three times in three years for ratio or supervision violations must be audited (WAC 296-46B-975).
Appeals (RCW 19.28.131, 19.28.271)
The assessed party files a written notice of appeal with L&I within 20 days after notice of the penalty is given.
The notice must include a certified check for $200 or 10 percent of the penalty, whichever is less , but never less than $100 . It is returned if the Electrical Board does not sustain L&I's decision.
Filing the appeal stays the penalty until the board decides.
The Electrical Board (RCW 19.28.311)
The board has 15 members appointed by the governor , with the advice of the director of L&I, for four-year terms . It includes representatives of utilities, a telecommunications provider, licensed electrical contractors (three), a licensed telecommunications contractor, manufacturers or distributors, the public, certified electricians (three), a telecommunications worker, a professional electrical engineer, an outside line worker, and one nonvoting city building official.
The board advises the director on enforcement, installation standards, inspection procedures, and rules. No rule may be amended or repealed until the board has had a chance to consider it. The board also hears appeals and certificate revocation cases.
Revocation of certificates (RCW 19.28.241)
L&I may revoke a certificate of competency when:
- it was obtained through error or fraud ;
- the holder is judged incompetent to work in the trade;
- the holder violated RCW 19.28.161-.271 or a rule adopted under the chapter; or
the holder committed a serious violation , meaning one that presents imminent danger to the public.
Before revoking, L&I sends written notice by registered mail with the allegations and an opportunity for a hearing before the board. After a revocation, L&I may deny a new application for up to two years . A suspended certificate can be renewed, but it stays suspended and the holder must pass the competency exam before it is reactivated. A revoked certificate cannot be renewed (WAC 296-46B-940(12), (13)).
Examination rules (WAC 296-46B-960)
- Topic Rule
- Passing score At least 70% on each exam or section
Open book, allowed Any original copyrighted material; a silent, nonprinting, nonprogrammable calculator not designed for preprogrammed electrical calculations; copies of RCW 19.28 and WAC 296-46B; a foreign-language dictionary without definitions
Not allowed Copies of copyrighted material; copies of internet publications other than the RCW and WAC; personal notes; any personal computing device other than the calculator
Exam period Electrician and master electrician candidates must pass all sections within one year from the exam approval date ; passed sections need not be retaken within that period; if the year runs out, start over with all sections
Accommodations For disability or limited English proficiency, by written request; extra time up to double the normal time
- Retest wait Two weeks after a failing score
- Three failures Failing any part three times within one year means a three-month wait before retaking it
Score review Written request to the chief electrical inspector within 20 days of the exam, with the review fee ($165.50 in the current WAC 296-46B-909 table). The candidate gets one hour to review and must cite published references. L&I decides within 15 days and changes results only for clear and convincing evidence that would produce a passing score.
- Cheating A wait of at least 11 months ; the retest is given by L&I in Tumwater; civil penalties possible
- Confidentiality All exam questions are confidential; candidates agree not to copy or share content
- After failing A candidate may keep working as a supervised trainee with a valid training certificate
L&I's exam page adds that a first attempt in each one-year period must include all sections, and that after three failures the 90-day wait applies between all attempts until the candidate passes.