1 Chapter 1: Administration, Licensing, & General Regulations

1.1 Washington Plumber Certification Law: RCW 18.106, WAC 296-400A, Trainees, & Supervision 1.2 Permits, Inspections, Tests, & Disinfection (UPC Chapter 1, 609, 712) 1.3 General Regulations: Prohibited Fittings, Pipe Protection, Nail Plates, Sleeves, & Trenching (UPC Chapter 3) 1.4 Hangers, Supports, Rod Sizes, Dissimilar Metals, & Expansion (UPC 313, Table 313.3)

2 Chapter 2: Plumbing Fixtures, Fittings, & Clearances

2.1 Fixture Setting, Clearances, Closet Flanges, & Water Closets (UPC 402, 411, 413; WA 402.5) 2.2 Showers, Shower Pans, Bathtubs, Lavatories, Bidets, & Scald Limits (UPC 407–410; WA 408) 2.3 Urinals, Floor Drains, Floor Sinks, Sinks, Dishwashers, Disposers, & Special Fixtures (UPC 412–421) 2.4 Minimum Fixture Counts in Washington: IBC Table 2902.1, Not UPC Table 422.1

3 Chapter 3: Water Heaters & Storage Tanks

3.1 Water Heater Permits, Sizing (WA Table 501.1), Bedroom and Bathroom Locations, & Safety Devices 3.2 Temperature and Pressure Relief Valves & Discharge Piping (UPC 504.6, 608; WA 608.3.1 and 608.5) 3.3 Water Heater Installation Details: Garages, Pans, Supports, Attic and Under-Floor Access, & Washington's Mechanical Code Deletions 3.4 Seismic Strapping, Thermal Expansion Tanks, Pressure Regulators, & Temperature Controls (WA 507.2, 608.2, 608.3)

4 Chapter 4: Water Supply and Distribution Systems

4.1 Water Piping Materials, Joints, Lead Limits, Under-Slab Rules, & Velocity (UPC 604, 605, 609, 610.12) 4.2 Water Supply Fixture Units & the Sizing Tables (UPC 610.3, 610.4, 610.8, 610.10) 4.3 Water Pressure Limits, Booster Pumps, Potable Water Tanks, & Water Hammer (UPC 607–609) 4.4 Water Valves, Shutoffs, Manifolds, & Hot Water Distribution (UPC 606, 609.11; WA 210.0 and 609.11)

5 Chapter 5: Backflow Prevention & Cross-Connection Control

5.1 Backflow Principles: Backsiphonage, Backpressure, & Degree of Hazard (UPC 602–603; WAC 246-290-490) 5.2 Backflow Assemblies and Devices: RP, DC, PVB, SVB, AVB, & Installation Rules (UPC 603.3, 603.4, Table 603.2) 5.3 Air Gaps, Critical Level, & Specific Backflow Applications (UPC Table 603.3.1, 603.5) 5.4 Backflow Testing, Certified Testers, & Washington's Cross-Connection Program (WA 603.4.2; WAC 246-290-490, 246-292)

6 Chapter 6: Sanitary Drainage Systems & Sizing

6.1 DWV Materials, Joints, & Changes in Direction (UPC 701, 704–706; WA 701.2) 6.2 Drainage Fixture Units, Trap Sizes, & Flow Conversions (UPC Table 702.1, 702.2, 702.3) 6.3 Sizing Drainage Piping with Table 703.2 (Vertical, Horizontal, Water Closet Limits, & WA Note 4) 6.4 Building Drains, Grade, Gravity Drainage, Backwater Valves, & Washington's Deletion of Building Sewer Rules

7 Chapter 7: Cleanouts, Sumps and Ejectors, Indirect Wastes, & Interceptors

7.1 Cleanouts: Location, Spacing, Size, and Clearance (UPC 707 as Amended by Washington) 7.2 Sumps, Sewage Ejectors, Grinder Pumps, & Macerating Systems (UPC 710) 7.3 Indirect Wastes, Air Gaps and Air Breaks, Receptors, Standpipes, & Condensate (UPC Chapter 8) 7.4 Interceptors and Separators: Grease, Sand, Oil, Laundry, & Bottling (UPC 1009–1017)

8 Chapter 8: Vents and Venting Fundamentals

8.1 Venting Fundamentals: Trap Seal Protection, Vent Sizing, the Half-Drain Rule, & Aggregate Venting (UPC 901–904) 8.2 Vent Grades and Connections, Vent Stacks, Relief and Yoke Vents, & Suds Relief (UPC 905, 907, 711) 8.3 Wet Venting and Circuit Venting (UPC 908, 911; WA 908.2.4 and 911.1) 8.4 Island Fixture Venting, Combination Waste and Vent Systems, & Engineered Vent Systems (UPC 909, 910, 912)

9 Chapter 9: Vent Terminations, Traps, & Priming

9.1 Vent Terminations: Roof Height, Clearances, Used Roofs, Outdoor Vents, & Frost Closure (UPC 906) 9.2 Traps, Trap Arms, Table 1002.2 Distances, & Prohibited Traps (UPC 1001–1004) 9.3 How Trap Seals Are Lost & How the Code Protects Them: Venting, Seal Depth, and Trap Seal Primers (UPC 901.3, 1005, 1007)

10 Chapter 10: Alternate Water, Rainwater Catchment, Definitions, & Referenced Standards

10.1 Alternate Water Sources: Reclaimed, Gray, and On-Site Treated Water (UPC Chapter 15 as Amended by Washington) 10.2 Nonpotable Rainwater Catchment Systems (UPC Chapter 16 as Amended by Washington) 10.3 Key UPC Definitions and Referenced Standards (UPC Chapters 2 and 17; WA Definition Amendments)

11 Chapter 11: Part 2 — Waste & Vent Isometric Drawings & Plan Analysis

11.1 Part 2 Explained: Reading the Waste and Vent Drawing 11.2 Part 2 Worked Example: Accumulating DFU and Sizing Every Drain Segment 11.3 Part 2 Worked Example: Sizing Individual, Branch, and Main Vents and Checking Aggregate Venting 11.4 Spotting Code Violations on Waste and Vent Drawings: A Checklist with Code Citations

12 Chapter 12: Part 3 — Water Supply Isometric Drawings & Pipe Sizing

12.1 Part 3 Explained: Reading the Water Sizing Drawing and Gathering the 610.7 Data 12.2 Part 3 Worked Example: Accumulating Water Supply Fixture Units, Cold and Hot 12.3 Part 3: Available Pressure, Elevation, Regulators, Device Losses, and the Length Column 12.4 Part 3 Worked Example: Sizing the Meter, Building Supply, and Every Branch with Table 610.4

13 Chapter 13: Washington Amendments Review, Plumbing Math, & Water Service Special Topics

13.1 Washington's Amendments to the 2015 UPC (WAC 51-56): A Consolidated Review 13.2 Plumbing Math for the Exam: Offsets, Rolling Offsets, Grade, Areas, Volumes, and Pressure 13.3 Water Service Details, Treatment Units, Softeners, & Residential Sprinklers (UPC 604, 609, 611, 612; WA Amendments)

14 Chapter 14: Comprehensive Exam Preparation & Test-Taking Strategy

14.1 The PSI Exam Day: Structure, Fees, Retakes, Rules, and Pacing 14.2 Using the Provided Tables Fast (702.1, 610.3, 610.4, 610.10) and Writing the Missing Ones from Memory 14.3 High-Yield Number Review, Classic Traps, and a Final Readiness Checklist

1.1 Washington Plumber Certification Law: RCW 18.106, WAC 296-400A, Trainees, & Supervision

Key Takeaways Explain This Topic AI

Washington journey level (PL01) exam eligibility requires 8,000 hours over at least 4 years, including 4,000 commercial hours under a certified journey level plumber (WAC 296-400A-121).

Candidates must complete 16 hours of approved continuing education, including at least 4 hours of industry-related electrical, before taking the journey level exam (WAC 296-400A-121).

A journey level certificate renews every 3 years on the holder's birthdate and requires 24 continuing education hours: at least 12 plumbing code and 4 electrical (WAC 296-400A-028).

One journey level plumber working as a journey level plumber may supervise no more than 1 trainee on a job site, with supervision at least 75% of the time (WAC 296-400A-120).

A notice of infraction under RCW 18.106 must be appealed within 20 days of service, accompanied by a $200 certified check (RCW 18.106.200).

Last updated: September 2026

Why Licensing Law Matters Before You Study Code

The Washington journey level exam itself is built from the Uniform Plumbing Code (UPC), but you only reach the exam by satisfying Washington's certification law. Knowing the rules also protects your hours: trainee time that is worked out of ratio, on an expired card, or without the required continuing education is simply not credited. Two legal texts govern everything in this section:

Chapter 18.106 RCW (Plumbers) , the statute passed by the Legislature. It requires a certificate, defines trainee supervision, sets renewal, and creates civil infractions.

Chapter 296-400A WAC (Plumber Certification Rules) , the Department of Labor & Industries (L&I) rules that implement the statute: certificate types, exam eligibility, continuing education, fees, and the penalty schedule.

Under RCW 18.106.020, no person may engage in the trade of plumbing without a certificate, temporary permit, or trainee certificate and photo identification in their possession . L&I also requires the certificate to be worn and visibly displayed on the job.

Certificate Types and Scope (WAC 296-400A-010)

  • Certificate Code Scope of work
  • Journey level plumber PL01 All phases of plumbing: residential, commercial, and industrial

Residential specialty plumber PL02 Installation, maintenance, and repair of all phases of plumbing in residential structures

Residential service plumber PL04 Repair or replacement of existing fixtures, piping, and fittings in single-family dwellings and duplexes

  • Pump and irrigation specialty PL03 Pumping, treatment, storage, and irrigation equipment for domestic water
  • Limited volume domestic pump PL03A Domestic pumping systems not exceeding 100 gallons per minute

Backflow specialty (maintenance and repair) PL30 Maintenance and repair of backflow assemblies inside buildings; not installing or replacing them

Plumber trainee PT00 / PT31 Learning the trade under supervision; PT31 is the backflow trainee card

A medical gas piping installer endorsement is separate. Only an active Washington journey level plumber may apply for it.

Exam Eligibility and Fees

WAC 296-400A-121 sets the experience you must document before L&I approves a journey level exam application:

8,000 hours and not less than four years of documented training.

Those hours must include 4,000 hours of commercial plumbing experience under the direct supervision of a certified journey level plumber.

16 hours of approved continuing education , including at least 4 hours of industry-related electrical training , completed before testing.

WAC 296-400A-045 sets L&I's fees. The journey level exam application fee is $202.10 per exam and is nonrefundable. The journey level certificate (first card or renewal) is $242.70 for three years, and a trainee certificate is $60.00 . PSI charges its own separate scheduling fee (see Section 14.1). After you pass, you have 90 days to pay the certification fee. If you miss that deadline, you must retest (WAC 296-400A-020).

Trainee Certificates, Hours, and Continuing Education

Every apprentice or learner must hold a plumbing training certificate . It is valid for one year and must be renewed annually (RCW 18.106.070; WAC 296-400A-120).

Trainees need 8 hours of approved continuing education per year . Over a two-year period, those hours must include at least 8 hours of plumbing code and 4 hours of electrical training.

At renewal, the trainee submits signed, notarized affidavits of experience listing each employer and the hours worked by category. Hours are due within 30 days after the trainee certificate's renewal date. If they are late, the trainee may lose credit for them.

Hours worked while a trainee card is expired or inactive are not credited . Hours are also not credited while the trainee owes outstanding penalties.

Certified plumbers renew every three years on or before their birthdate (RCW 18.106.070). Journey level renewal requires 24 hours of approved continuing education, with at least 12 hours of plumbing code and 4 hours of electrical . The remaining 8 hours may be plumbing or electrical. If you renew late, you pay a doubled fee. If you do not renew within 90 days of the renewal date, you must retake the examination.

Supervision Ratios

The ratio rules in RCW 18.106.070(4) and WAC 296-400A-120(3) apply until December 31, 2028:

  • Supervising plumber and job Maximum trainees
  • Journey level plumber working as a journey level plumber, any job site 1
  • Residential service plumber 1

Specialty plumber, or journey level plumber working as a specialty plumber, on a residential structure job site 3 (2 after December 31, 2028)

  • Domestic pump work 3 (2 after December 31, 2028)
  • Medical gas or backflow trainee 1, with 100% supervision

The supervising plumber must be on the same job site for at least 75% of each working day . The statute allows a narrow remote-supervision option by live audio and video. It applies only when the trainee has more than 2,000 hours, the supervisor is within 40 miles, and the work is residential service plumbing. Apprentices and approved trade-school trainees may work without direct on-site supervision during the last six months of their required experience.

Infractions, Appeals, and Reciprocity

Violations of RCW 18.106 are civil infractions. Each day and each job site in violation is a separate infraction. WAC 296-400A-400 sets escalating penalties:

  • Infraction Individual Contractor or employer
  • First $100 $500
  • Second $200 $1,000
  • Third $500 $2,000
  • Fourth $1,000 $4,000
  • Later $2,000, $4,000, then up to $5,000 Up to $5,000

To contest a notice of infraction, file a notice of appeal with L&I within 20 days of service , together with a $200 certified check . An administrative law judge at the Office of Administrative Hearings decides the appeal (RCW 18.106.200).

Washington has a reciprocal journey level agreement with Idaho . Other out-of-state plumbers must pass the Washington exam. Out-of-state journey level plumbers from non-reciprocal states may qualify for a temporary permit valid for 120 days ($100.30).