Study guide
14.1 The PSI Exam Day: Structure, Fees, Retakes, Rules, and Pacing
Washington Journeyman Plumber Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Administration, Licensing, & General Regulations
1.1 Washington Plumber Certification Law: RCW 18.106, WAC 296-400A, Trainees, & Supervision 1.2 Permits, Inspections, Tests, & Disinfection (UPC Chapter 1, 609, 712) 1.3 General Regulations: Prohibited Fittings, Pipe Protection, Nail Plates, Sleeves, & Trenching (UPC Chapter 3) 1.4 Hangers, Supports, Rod Sizes, Dissimilar Metals, & Expansion (UPC 313, Table 313.3)
2 Chapter 2: Plumbing Fixtures, Fittings, & Clearances
2.1 Fixture Setting, Clearances, Closet Flanges, & Water Closets (UPC 402, 411, 413; WA 402.5) 2.2 Showers, Shower Pans, Bathtubs, Lavatories, Bidets, & Scald Limits (UPC 407–410; WA 408) 2.3 Urinals, Floor Drains, Floor Sinks, Sinks, Dishwashers, Disposers, & Special Fixtures (UPC 412–421) 2.4 Minimum Fixture Counts in Washington: IBC Table 2902.1, Not UPC Table 422.1
3 Chapter 3: Water Heaters & Storage Tanks
3.1 Water Heater Permits, Sizing (WA Table 501.1), Bedroom and Bathroom Locations, & Safety Devices 3.2 Temperature and Pressure Relief Valves & Discharge Piping (UPC 504.6, 608; WA 608.3.1 and 608.5) 3.3 Water Heater Installation Details: Garages, Pans, Supports, Attic and Under-Floor Access, & Washington's Mechanical Code Deletions 3.4 Seismic Strapping, Thermal Expansion Tanks, Pressure Regulators, & Temperature Controls (WA 507.2, 608.2, 608.3)
4 Chapter 4: Water Supply and Distribution Systems
4.1 Water Piping Materials, Joints, Lead Limits, Under-Slab Rules, & Velocity (UPC 604, 605, 609, 610.12) 4.2 Water Supply Fixture Units & the Sizing Tables (UPC 610.3, 610.4, 610.8, 610.10) 4.3 Water Pressure Limits, Booster Pumps, Potable Water Tanks, & Water Hammer (UPC 607–609) 4.4 Water Valves, Shutoffs, Manifolds, & Hot Water Distribution (UPC 606, 609.11; WA 210.0 and 609.11)
5 Chapter 5: Backflow Prevention & Cross-Connection Control
5.1 Backflow Principles: Backsiphonage, Backpressure, & Degree of Hazard (UPC 602–603; WAC 246-290-490) 5.2 Backflow Assemblies and Devices: RP, DC, PVB, SVB, AVB, & Installation Rules (UPC 603.3, 603.4, Table 603.2) 5.3 Air Gaps, Critical Level, & Specific Backflow Applications (UPC Table 603.3.1, 603.5) 5.4 Backflow Testing, Certified Testers, & Washington's Cross-Connection Program (WA 603.4.2; WAC 246-290-490, 246-292)
6 Chapter 6: Sanitary Drainage Systems & Sizing
6.1 DWV Materials, Joints, & Changes in Direction (UPC 701, 704–706; WA 701.2) 6.2 Drainage Fixture Units, Trap Sizes, & Flow Conversions (UPC Table 702.1, 702.2, 702.3) 6.3 Sizing Drainage Piping with Table 703.2 (Vertical, Horizontal, Water Closet Limits, & WA Note 4) 6.4 Building Drains, Grade, Gravity Drainage, Backwater Valves, & Washington's Deletion of Building Sewer Rules
7 Chapter 7: Cleanouts, Sumps and Ejectors, Indirect Wastes, & Interceptors
7.1 Cleanouts: Location, Spacing, Size, and Clearance (UPC 707 as Amended by Washington) 7.2 Sumps, Sewage Ejectors, Grinder Pumps, & Macerating Systems (UPC 710) 7.3 Indirect Wastes, Air Gaps and Air Breaks, Receptors, Standpipes, & Condensate (UPC Chapter 8) 7.4 Interceptors and Separators: Grease, Sand, Oil, Laundry, & Bottling (UPC 1009–1017)
8 Chapter 8: Vents and Venting Fundamentals
8.1 Venting Fundamentals: Trap Seal Protection, Vent Sizing, the Half-Drain Rule, & Aggregate Venting (UPC 901–904) 8.2 Vent Grades and Connections, Vent Stacks, Relief and Yoke Vents, & Suds Relief (UPC 905, 907, 711) 8.3 Wet Venting and Circuit Venting (UPC 908, 911; WA 908.2.4 and 911.1) 8.4 Island Fixture Venting, Combination Waste and Vent Systems, & Engineered Vent Systems (UPC 909, 910, 912)
9 Chapter 9: Vent Terminations, Traps, & Priming
9.1 Vent Terminations: Roof Height, Clearances, Used Roofs, Outdoor Vents, & Frost Closure (UPC 906) 9.2 Traps, Trap Arms, Table 1002.2 Distances, & Prohibited Traps (UPC 1001–1004) 9.3 How Trap Seals Are Lost & How the Code Protects Them: Venting, Seal Depth, and Trap Seal Primers (UPC 901.3, 1005, 1007)
10 Chapter 10: Alternate Water, Rainwater Catchment, Definitions, & Referenced Standards
10.1 Alternate Water Sources: Reclaimed, Gray, and On-Site Treated Water (UPC Chapter 15 as Amended by Washington) 10.2 Nonpotable Rainwater Catchment Systems (UPC Chapter 16 as Amended by Washington) 10.3 Key UPC Definitions and Referenced Standards (UPC Chapters 2 and 17; WA Definition Amendments)
11 Chapter 11: Part 2 — Waste & Vent Isometric Drawings & Plan Analysis
11.1 Part 2 Explained: Reading the Waste and Vent Drawing 11.2 Part 2 Worked Example: Accumulating DFU and Sizing Every Drain Segment 11.3 Part 2 Worked Example: Sizing Individual, Branch, and Main Vents and Checking Aggregate Venting 11.4 Spotting Code Violations on Waste and Vent Drawings: A Checklist with Code Citations
12 Chapter 12: Part 3 — Water Supply Isometric Drawings & Pipe Sizing
12.1 Part 3 Explained: Reading the Water Sizing Drawing and Gathering the 610.7 Data 12.2 Part 3 Worked Example: Accumulating Water Supply Fixture Units, Cold and Hot 12.3 Part 3: Available Pressure, Elevation, Regulators, Device Losses, and the Length Column 12.4 Part 3 Worked Example: Sizing the Meter, Building Supply, and Every Branch with Table 610.4
13 Chapter 13: Washington Amendments Review, Plumbing Math, & Water Service Special Topics
13.1 Washington's Amendments to the 2015 UPC (WAC 51-56): A Consolidated Review 13.2 Plumbing Math for the Exam: Offsets, Rolling Offsets, Grade, Areas, Volumes, and Pressure 13.3 Water Service Details, Treatment Units, Softeners, & Residential Sprinklers (UPC 604, 609, 611, 612; WA Amendments)
14 Chapter 14: Comprehensive Exam Preparation & Test-Taking Strategy
14.1 The PSI Exam Day: Structure, Fees, Retakes, Rules, and Pacing 14.2 Using the Provided Tables Fast (702.1, 610.3, 610.4, 610.10) and Writing the Missing Ones from Memory 14.3 High-Yield Number Review, Classic Traps, and a Final Readiness Checklist
14.1 The PSI Exam Day: Structure, Fees, Retakes, Rules, and Pacing
Key Takeaways Explain This Topic AI
The Washington journeyman exam has three closed-book portions of 100, 25, and 25 items, each 90 minutes and each requiring 70 percent (PSI candidate bulletin, revised July 30, 2026).
Candidates must pass all three portions; after a failure, L&I determines whether any previously passed portion is waived.
L&I's journey level exam application fee is $202.10, non-refundable, and an approved application is valid for one year.
PSI's fee is $84 for the three-portion exam and $52 for each individual portion on a retest.
After failing, a candidate must reapply with L&I, pay the application fee again, and wait 14 days from the last failed test before retesting.
Last updated: September 2026
The Three Portions
- Portion Items Time Passing Book
- Journey level code and general trade knowledge 100 90 min 70% Closed
- Waste and vent journey level drawings 25 90 min 70% Closed
- Water sizing journey level drawings 25 90 min 70% Closed
The totals are 150 items and 270 minutes . According to L&I, the code portion draws on UPC Chapters 1–10, 15, 16, and 17 with Washington amendments . The drawing portions draw on Chapter 7 (waste and vent) and Chapter 6 (water). Tables 702.1, 610.3, 610.4, and 610.10 are provided; Table 703.2 is not. The exam is based on the 2015 UPC .
Pass all three: The PSI bulletin says journey level candidates "need to pass all 3 portions of the exam. If they fail any portion of the exam then they will have to retake all portions of the exam. The Department will make the determination if the candidate will receive a waived portion based off of previous attempts."
Getting to the Test
Apply to L&I online or by mail with the $202.10 non-refundable exam fee. Include affidavits of experience, a copy of photo ID, and, for out-of-state plumbers, a copy of the out-of-state license. Journey level candidates need 8,000 hours including 4,000 commercial, plus 16 hours of continuing education (Section 1.1).
Approval: Approved applications are valid for one year . L&I sends instructions, and PSI emails a confirmation.
Schedule with PSI online or by phone and pay PSI's fee: $84 for the three-portion exam, $52 per portion on a retest. PSI fees are not refundable or transferable and are valid for one year from payment.
Reschedule or cancel at least 2 days before the appointment. For a Monday exam, notice must reach PSI by the previous Saturday. Voicemail and email do not count.
Exam Day Rules
Arrive at least 30 minutes early. Late arrivals may be refused and forfeit the fee.
Identification: one valid, unexpired, government-issued photo ID with a signature. Bring the examination notice or certification from the Department . Names must match exactly.
Allowed: a silent, battery-operated, non-programmable calculator with no paper tape and no alphabetic keyboard. PSI provides scratch paper and a pencil , which are returned at the end.
Not allowed: phones, smart watches, bags, notes, reference books (these exams are closed book), food and drink, hats not worn for religious reasons, and bulky outerwear. Items go in secure storage.
Tutorial: up to 15 minutes before the exam, and it does not count against exam time.
Navigation: you may return to any question and change your answer while time remains. You can leave comments on questions, but PSI does not respond to them.
Missed appointment: failing to cancel at least 2 days ahead, not appearing, not checking in on time, or lacking ID forfeits the fee. The bulletin says an absence counts as a fail.
Results and What Comes Next
Scores are given immediately. A pass shows "PASS". A fail comes with a diagnostic report of strengths and weaknesses.
After passing, you have 90 days to pay the certification fee ($242.70 for three years). Otherwise you must retest (WAC 296-400A-020).
After failing, reapply with L&I (new application and fee) and wait 14 days from the last failed test. Unlimited attempts are allowed during the one-year eligibility.
Pacing
- Portion Average time per item Strategy
- Code (100 in 90 min) About 54 seconds One pass answering what you know; flag the rest; come back
Waste and vent (25 in 90 min) About 3.6 minutes Spend the first 10 to 15 minutes building a DFU and size ledger (Section 11.1)
Water sizing (25 in 90 min) About 3.6 minutes Fix the pressure range and length column first; build the fixture unit ledger (Section 12.1)
70 percent means about 70 of 100 on the code portion and roughly 18 of 25 on each drawing portion.
Test-Taking Techniques That Fit This Exam
Washington amendments first. When two options differ only by a Washington amendment, such as 21 or 24 inches, or 900 or 1,024 square inches, the Washington value is the answer (Section 13.1).
Read the occupancy. Private, public, and assembly values differ in Tables 702.1 and 610.3.
Write the notes on scratch paper at the start. Table 703.2 with its notes, Table 1002.2, and the vent area list take about 2 minutes to write from memory, and they speed up both drawing portions.
Units and rounding: round fixture unit totals up when choosing a pipe size. Never round a load down to fit a smaller pipe.
Do not change answers without a reason. Change an answer only when you find a specific error.
Where to Test
The July 30, 2026 PSI bulletin lists Washington test sites including Arlington, Bremerton, Ellensburg, Everett, Kennewick, Lakewood, Liberty Lake, Olympia, Puyallup, Seattle (Bellevue), Snohomish, Spokane (Spokane Valley), Tacoma (Spanaway), Vancouver, and Yakima. Out-of-state testing is requested through PSI's accommodations process.