Study guide

9.2 Traps, Trap Arms, Table 1002.2 Distances, & Prohibited Traps (UPC 1001–1004)

Washington Journeyman Plumber Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Administration, Licensing, & General Regulations

1.1 Washington Plumber Certification Law: RCW 18.106, WAC 296-400A, Trainees, & Supervision 1.2 Permits, Inspections, Tests, & Disinfection (UPC Chapter 1, 609, 712) 1.3 General Regulations: Prohibited Fittings, Pipe Protection, Nail Plates, Sleeves, & Trenching (UPC Chapter 3) 1.4 Hangers, Supports, Rod Sizes, Dissimilar Metals, & Expansion (UPC 313, Table 313.3)

2 Chapter 2: Plumbing Fixtures, Fittings, & Clearances

2.1 Fixture Setting, Clearances, Closet Flanges, & Water Closets (UPC 402, 411, 413; WA 402.5) 2.2 Showers, Shower Pans, Bathtubs, Lavatories, Bidets, & Scald Limits (UPC 407–410; WA 408) 2.3 Urinals, Floor Drains, Floor Sinks, Sinks, Dishwashers, Disposers, & Special Fixtures (UPC 412–421) 2.4 Minimum Fixture Counts in Washington: IBC Table 2902.1, Not UPC Table 422.1

3 Chapter 3: Water Heaters & Storage Tanks

3.1 Water Heater Permits, Sizing (WA Table 501.1), Bedroom and Bathroom Locations, & Safety Devices 3.2 Temperature and Pressure Relief Valves & Discharge Piping (UPC 504.6, 608; WA 608.3.1 and 608.5) 3.3 Water Heater Installation Details: Garages, Pans, Supports, Attic and Under-Floor Access, & Washington's Mechanical Code Deletions 3.4 Seismic Strapping, Thermal Expansion Tanks, Pressure Regulators, & Temperature Controls (WA 507.2, 608.2, 608.3)

4 Chapter 4: Water Supply and Distribution Systems

4.1 Water Piping Materials, Joints, Lead Limits, Under-Slab Rules, & Velocity (UPC 604, 605, 609, 610.12) 4.2 Water Supply Fixture Units & the Sizing Tables (UPC 610.3, 610.4, 610.8, 610.10) 4.3 Water Pressure Limits, Booster Pumps, Potable Water Tanks, & Water Hammer (UPC 607–609) 4.4 Water Valves, Shutoffs, Manifolds, & Hot Water Distribution (UPC 606, 609.11; WA 210.0 and 609.11)

5 Chapter 5: Backflow Prevention & Cross-Connection Control

5.1 Backflow Principles: Backsiphonage, Backpressure, & Degree of Hazard (UPC 602–603; WAC 246-290-490) 5.2 Backflow Assemblies and Devices: RP, DC, PVB, SVB, AVB, & Installation Rules (UPC 603.3, 603.4, Table 603.2) 5.3 Air Gaps, Critical Level, & Specific Backflow Applications (UPC Table 603.3.1, 603.5) 5.4 Backflow Testing, Certified Testers, & Washington's Cross-Connection Program (WA 603.4.2; WAC 246-290-490, 246-292)

6 Chapter 6: Sanitary Drainage Systems & Sizing

6.1 DWV Materials, Joints, & Changes in Direction (UPC 701, 704–706; WA 701.2) 6.2 Drainage Fixture Units, Trap Sizes, & Flow Conversions (UPC Table 702.1, 702.2, 702.3) 6.3 Sizing Drainage Piping with Table 703.2 (Vertical, Horizontal, Water Closet Limits, & WA Note 4) 6.4 Building Drains, Grade, Gravity Drainage, Backwater Valves, & Washington's Deletion of Building Sewer Rules

7 Chapter 7: Cleanouts, Sumps and Ejectors, Indirect Wastes, & Interceptors

7.1 Cleanouts: Location, Spacing, Size, and Clearance (UPC 707 as Amended by Washington) 7.2 Sumps, Sewage Ejectors, Grinder Pumps, & Macerating Systems (UPC 710) 7.3 Indirect Wastes, Air Gaps and Air Breaks, Receptors, Standpipes, & Condensate (UPC Chapter 8) 7.4 Interceptors and Separators: Grease, Sand, Oil, Laundry, & Bottling (UPC 1009–1017)

8 Chapter 8: Vents and Venting Fundamentals

8.1 Venting Fundamentals: Trap Seal Protection, Vent Sizing, the Half-Drain Rule, & Aggregate Venting (UPC 901–904) 8.2 Vent Grades and Connections, Vent Stacks, Relief and Yoke Vents, & Suds Relief (UPC 905, 907, 711) 8.3 Wet Venting and Circuit Venting (UPC 908, 911; WA 908.2.4 and 911.1) 8.4 Island Fixture Venting, Combination Waste and Vent Systems, & Engineered Vent Systems (UPC 909, 910, 912)

9 Chapter 9: Vent Terminations, Traps, & Priming

9.1 Vent Terminations: Roof Height, Clearances, Used Roofs, Outdoor Vents, & Frost Closure (UPC 906) 9.2 Traps, Trap Arms, Table 1002.2 Distances, & Prohibited Traps (UPC 1001–1004) 9.3 How Trap Seals Are Lost & How the Code Protects Them: Venting, Seal Depth, and Trap Seal Primers (UPC 901.3, 1005, 1007)

10 Chapter 10: Alternate Water, Rainwater Catchment, Definitions, & Referenced Standards

10.1 Alternate Water Sources: Reclaimed, Gray, and On-Site Treated Water (UPC Chapter 15 as Amended by Washington) 10.2 Nonpotable Rainwater Catchment Systems (UPC Chapter 16 as Amended by Washington) 10.3 Key UPC Definitions and Referenced Standards (UPC Chapters 2 and 17; WA Definition Amendments)

11 Chapter 11: Part 2 — Waste & Vent Isometric Drawings & Plan Analysis

11.1 Part 2 Explained: Reading the Waste and Vent Drawing 11.2 Part 2 Worked Example: Accumulating DFU and Sizing Every Drain Segment 11.3 Part 2 Worked Example: Sizing Individual, Branch, and Main Vents and Checking Aggregate Venting 11.4 Spotting Code Violations on Waste and Vent Drawings: A Checklist with Code Citations

12 Chapter 12: Part 3 — Water Supply Isometric Drawings & Pipe Sizing

12.1 Part 3 Explained: Reading the Water Sizing Drawing and Gathering the 610.7 Data 12.2 Part 3 Worked Example: Accumulating Water Supply Fixture Units, Cold and Hot 12.3 Part 3: Available Pressure, Elevation, Regulators, Device Losses, and the Length Column 12.4 Part 3 Worked Example: Sizing the Meter, Building Supply, and Every Branch with Table 610.4

13 Chapter 13: Washington Amendments Review, Plumbing Math, & Water Service Special Topics

13.1 Washington's Amendments to the 2015 UPC (WAC 51-56): A Consolidated Review 13.2 Plumbing Math for the Exam: Offsets, Rolling Offsets, Grade, Areas, Volumes, and Pressure 13.3 Water Service Details, Treatment Units, Softeners, & Residential Sprinklers (UPC 604, 609, 611, 612; WA Amendments)

14 Chapter 14: Comprehensive Exam Preparation & Test-Taking Strategy

14.1 The PSI Exam Day: Structure, Fees, Retakes, Rules, and Pacing 14.2 Using the Provided Tables Fast (702.1, 610.3, 610.4, 610.10) and Writing the Missing Ones from Memory 14.3 High-Yield Number Review, Classic Traps, and a Final Readiness Checklist

9.2 Traps, Trap Arms, Table 1002.2 Distances, & Prohibited Traps (UPC 1001–1004)

Key Takeaways Explain This Topic AI

UPC Table 1002.2 limits trap arm length to 30 inches for 1-1/4-inch, 42 inches for 1-1/2-inch, 60 inches for 2-inch, 72 inches for 3-inch, and 120 inches for 4-inch arms.

The developed length from the top of a water closet flange to the inner edge of its vent may not exceed 6 feet (Table 1002.2 note 2).

A trap arm may change direction up to 90 degrees without a cleanout; arms 3 inches and larger may change up to 135 degrees (UPC 1002.3).

S-traps, bell traps, crown-vented traps, traps with movable parts, and double trapping are prohibited (UPC 1004.1).

A fixture tailpiece may not exceed 24 inches, and one trap may serve up to three adjacent single-compartment sinks, laundry tubs, or lavatories with outlets no more than 30 inches apart (UPC 1001.2).

Last updated: September 2026

Separate Traps (UPC 1001.2)

Each plumbing fixture is separately trapped by an approved liquid-seal trap. Fixtures with integral traps, such as water closets, are excepted.

Not more than one trap is permitted on a trap arm.

Food waste disposers on restaurant, commercial, or industrial sinks connect to a separate trap .

Each domestic clothes washer and each laundry tub has its own trap. A laundry tub's trap may also receive an adjacent clothes washer.

The distance from the fixture outlet down to the trap weir is as short as practicable. A fixture tailpiece may not exceed 24 inches .

One trap may serve a set of up to three single-compartment sinks or laundry tubs of the same depth , or three lavatories that are immediately adjacent in the same room. The waste outlets must be no more than 30 inches apart , and with three compartments the trap is centrally located .

Trap Arms and Vent Distance (UPC 1002 and Table 1002.2)

A trap arm is the portion of the fixture drain between the trap and the vent. Section 1002.2 requires each fixture trap to have a protecting vent located so the developed length from the trap weir to the inner edge of the vent falls within Table 1002.2, and never less than two times the trap arm diameter .

  • Trap arm diameter Minimum distance, trap to vent Maximum distance, trap to vent
  • 1-1/4 in 2-1/2 in 30 in (2 ft 6 in)
  • 1-1/2 in 3 in 42 in (3 ft 6 in)
  • 2 in 4 in 60 in (5 ft)
  • 3 in 6 in 72 in (6 ft)
  • 4 in 8 in 120 in (10 ft)
  • Over 4 in 2 × diameter 120 in

Table notes:

Maintain a 1/4 inch per foot slope on the trap arm.

Water closets and similar fixtures: the developed length from the top of the closet flange to the inner edge of the vent may not exceed 6 feet .

Why the maximum? On a long, sloped trap arm, the pipe's end drops below the trap weir. Once the fall exceeds the pipe diameter, the arm can run full and self-siphon the trap. Why the minimum? A vent too close to the weir can let the trap siphon, or act like the prohibited crown vent.

Trap arm fall check: A 1-1/2-inch arm at its 42-inch maximum, sloped 1/4 inch per foot, falls 3.5 × 0.25 = 0.875 inch . That is less than the pipe diameter, so the vent opening stays above the weir level of the trap outlet.

Change of direction (UPC 1002.3)

A trap arm may change direction up to 90 degrees without a cleanout .

Exception: Trap arms 3 inches and larger may change up to 135 degrees without a cleanout.

Horizontal changes follow 706.3 (wyes or combination wye and 1/8 bends).

Trap arm cleanouts follow 1002.3 (707.14).

Vent opening (UPC 1002.4)

The vent pipe opening from a soil or waste pipe, except for water closets and similar fixtures, may not be below the trap weir .

Trap Construction and Size (UPC 1003)

1003.1: Traps are self-cleaning , except those inside an interceptor. Traps for tubs, showers, lavatories, sinks, laundry tubs, floor drains, urinals, and drinking fountains are of standard design, made of ABS, cast brass, cast iron, lead, PP, PVC, or other approved material. An exposed, accessible drawn copper-alloy tubing trap of at least No. 17 B&S gauge is allowed on fixtures discharging domestic sewage.

1003.2: No more than one slip joint on the outlet side of a trap, and no tubing trap without a listed tubing trap adapter.

1003.3: Trap size is at least the Table 702.1 size and no more than one pipe size larger . The trap is the same size as its trap arm .

Trap Seal (UPC 1005)

Each fixture trap has a liquid seal of at least 2 inches and not more than 4 inches , unless the AHJ requires a deeper seal. Traps are set level with respect to their seals and protected from freezing where necessary. The trap seal is the vertical distance between the crown weir and the top dip of the trap.

Prohibited Traps (UPC 1004)

Prohibited Why

Traps depending on movable parts , and bladders or check valves used as traps (1004.1, 1004.2) Parts stick or wear, and the seal is lost

Traps with concealed interior partitions , except plastic, glass, or similar corrosion-resistant ones A corroded partition fails without being seen

  • S-traps They self-siphon
  • Bell traps They clog and lose their seal
  • Crown-vented traps A vent at the crown clogs and promotes siphoning
  • Double trapping Two seals in series create an air lock
  • Drum and bottle traps Only for special conditions
  • Unvented traps Unless the code specifically allows them
  • Floor Drain Traps and Building Traps

1006.1: Floor drains connect to a trap that is readily cleanable and sized for its purpose. The drain inlet must be in full view. Where subject to reverse flow of sewage, the drain gets a backwater valve .

1008.1: Building traps are not installed unless the AHJ requires them. Where installed, they need a cleanout and a relieving vent or fresh-air intake on the inlet side, not larger than half the drain diameter , ending above grade in a screened outlet outside the building.