13.1 Washington's Amendments to the 2015 UPC (WAC 51-56): A Consolidated Review
Washington Journeyman Plumber Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Administration, Licensing, & General Regulations
1.1 Washington Plumber Certification Law: RCW 18.106, WAC 296-400A, Trainees, & Supervision 1.2 Permits, Inspections, Tests, & Disinfection (UPC Chapter 1, 609, 712) 1.3 General Regulations: Prohibited Fittings, Pipe Protection, Nail Plates, Sleeves, & Trenching (UPC Chapter 3) 1.4 Hangers, Supports, Rod Sizes, Dissimilar Metals, & Expansion (UPC 313, Table 313.3)
2 Chapter 2: Plumbing Fixtures, Fittings, & Clearances
2.1 Fixture Setting, Clearances, Closet Flanges, & Water Closets (UPC 402, 411, 413; WA 402.5) 2.2 Showers, Shower Pans, Bathtubs, Lavatories, Bidets, & Scald Limits (UPC 407–410; WA 408) 2.3 Urinals, Floor Drains, Floor Sinks, Sinks, Dishwashers, Disposers, & Special Fixtures (UPC 412–421) 2.4 Minimum Fixture Counts in Washington: IBC Table 2902.1, Not UPC Table 422.1
3 Chapter 3: Water Heaters & Storage Tanks
3.1 Water Heater Permits, Sizing (WA Table 501.1), Bedroom and Bathroom Locations, & Safety Devices 3.2 Temperature and Pressure Relief Valves & Discharge Piping (UPC 504.6, 608; WA 608.3.1 and 608.5) 3.3 Water Heater Installation Details: Garages, Pans, Supports, Attic and Under-Floor Access, & Washington's Mechanical Code Deletions 3.4 Seismic Strapping, Thermal Expansion Tanks, Pressure Regulators, & Temperature Controls (WA 507.2, 608.2, 608.3)
4 Chapter 4: Water Supply and Distribution Systems
4.1 Water Piping Materials, Joints, Lead Limits, Under-Slab Rules, & Velocity (UPC 604, 605, 609, 610.12) 4.2 Water Supply Fixture Units & the Sizing Tables (UPC 610.3, 610.4, 610.8, 610.10) 4.3 Water Pressure Limits, Booster Pumps, Potable Water Tanks, & Water Hammer (UPC 607–609) 4.4 Water Valves, Shutoffs, Manifolds, & Hot Water Distribution (UPC 606, 609.11; WA 210.0 and 609.11)
5 Chapter 5: Backflow Prevention & Cross-Connection Control
5.1 Backflow Principles: Backsiphonage, Backpressure, & Degree of Hazard (UPC 602–603; WAC 246-290-490) 5.2 Backflow Assemblies and Devices: RP, DC, PVB, SVB, AVB, & Installation Rules (UPC 603.3, 603.4, Table 603.2) 5.3 Air Gaps, Critical Level, & Specific Backflow Applications (UPC Table 603.3.1, 603.5) 5.4 Backflow Testing, Certified Testers, & Washington's Cross-Connection Program (WA 603.4.2; WAC 246-290-490, 246-292)
6 Chapter 6: Sanitary Drainage Systems & Sizing
6.1 DWV Materials, Joints, & Changes in Direction (UPC 701, 704–706; WA 701.2) 6.2 Drainage Fixture Units, Trap Sizes, & Flow Conversions (UPC Table 702.1, 702.2, 702.3) 6.3 Sizing Drainage Piping with Table 703.2 (Vertical, Horizontal, Water Closet Limits, & WA Note 4) 6.4 Building Drains, Grade, Gravity Drainage, Backwater Valves, & Washington's Deletion of Building Sewer Rules
7 Chapter 7: Cleanouts, Sumps and Ejectors, Indirect Wastes, & Interceptors
7.1 Cleanouts: Location, Spacing, Size, and Clearance (UPC 707 as Amended by Washington) 7.2 Sumps, Sewage Ejectors, Grinder Pumps, & Macerating Systems (UPC 710) 7.3 Indirect Wastes, Air Gaps and Air Breaks, Receptors, Standpipes, & Condensate (UPC Chapter 8) 7.4 Interceptors and Separators: Grease, Sand, Oil, Laundry, & Bottling (UPC 1009–1017)
8 Chapter 8: Vents and Venting Fundamentals
8.1 Venting Fundamentals: Trap Seal Protection, Vent Sizing, the Half-Drain Rule, & Aggregate Venting (UPC 901–904) 8.2 Vent Grades and Connections, Vent Stacks, Relief and Yoke Vents, & Suds Relief (UPC 905, 907, 711) 8.3 Wet Venting and Circuit Venting (UPC 908, 911; WA 908.2.4 and 911.1) 8.4 Island Fixture Venting, Combination Waste and Vent Systems, & Engineered Vent Systems (UPC 909, 910, 912)
9 Chapter 9: Vent Terminations, Traps, & Priming
9.1 Vent Terminations: Roof Height, Clearances, Used Roofs, Outdoor Vents, & Frost Closure (UPC 906) 9.2 Traps, Trap Arms, Table 1002.2 Distances, & Prohibited Traps (UPC 1001–1004) 9.3 How Trap Seals Are Lost & How the Code Protects Them: Venting, Seal Depth, and Trap Seal Primers (UPC 901.3, 1005, 1007)
10 Chapter 10: Alternate Water, Rainwater Catchment, Definitions, & Referenced Standards
10.1 Alternate Water Sources: Reclaimed, Gray, and On-Site Treated Water (UPC Chapter 15 as Amended by Washington) 10.2 Nonpotable Rainwater Catchment Systems (UPC Chapter 16 as Amended by Washington) 10.3 Key UPC Definitions and Referenced Standards (UPC Chapters 2 and 17; WA Definition Amendments)
11 Chapter 11: Part 2 — Waste & Vent Isometric Drawings & Plan Analysis
11.1 Part 2 Explained: Reading the Waste and Vent Drawing 11.2 Part 2 Worked Example: Accumulating DFU and Sizing Every Drain Segment 11.3 Part 2 Worked Example: Sizing Individual, Branch, and Main Vents and Checking Aggregate Venting 11.4 Spotting Code Violations on Waste and Vent Drawings: A Checklist with Code Citations
12 Chapter 12: Part 3 — Water Supply Isometric Drawings & Pipe Sizing
12.1 Part 3 Explained: Reading the Water Sizing Drawing and Gathering the 610.7 Data 12.2 Part 3 Worked Example: Accumulating Water Supply Fixture Units, Cold and Hot 12.3 Part 3: Available Pressure, Elevation, Regulators, Device Losses, and the Length Column 12.4 Part 3 Worked Example: Sizing the Meter, Building Supply, and Every Branch with Table 610.4
13 Chapter 13: Washington Amendments Review, Plumbing Math, & Water Service Special Topics
13.1 Washington's Amendments to the 2015 UPC (WAC 51-56): A Consolidated Review 13.2 Plumbing Math for the Exam: Offsets, Rolling Offsets, Grade, Areas, Volumes, and Pressure 13.3 Water Service Details, Treatment Units, Softeners, & Residential Sprinklers (UPC 604, 609, 611, 612; WA Amendments)
14 Chapter 14: Comprehensive Exam Preparation & Test-Taking Strategy
14.1 The PSI Exam Day: Structure, Fees, Retakes, Rules, and Pacing 14.2 Using the Provided Tables Fast (702.1, 610.3, 610.4, 610.10) and Writing the Missing Ones from Memory 14.3 High-Yield Number Review, Classic Traps, and a Final Readiness Checklist
13.1 Washington's Amendments to the 2015 UPC (WAC 51-56): A Consolidated Review
Key Takeaways Explain This Topic AI
WAC 51-56-003 adopts the UPC with Appendices A, B, and I, but not Chapters 12 and 14, the Chapter 5 venting and combustion air provisions, or the building sewer provisions.
Washington requires 24 inches in front of water closets and bidets, reduced to 21 inches in dwelling and sleeping units, and a 900-square-inch shower with a 30-inch circle.
Washington requires 12 inches of clearance in front of cleanouts 2 inches and smaller, 18 inches for larger cleanouts, and under-floor cleanouts within 20 feet of an access opening.
Washington requires an air gap or RP on boiler makeup water and a listed RP on carbonated beverage dispensers.
Washington defines hot water as 100°F or more and requires seismic strapping on every water heater, with 4 inches between the controls and the lower strap.
Last updated: September 2026
The Exam Edition and the Field Edition
Exam: L&I and PSI state that the plumber examinations are based on the 2015 Uniform Plumbing Code with the Washington amendments. PSI's July 2026 bulletin still lists the 2015 UPC with Washington amendments as the reference for the open-book pump exam.
Field: WAC 51-56 now adopts the 2021 UPC , effective statewide March 15, 2024 , with updated amendments. Several numbers changed in the field code, including 1.28 gpf water closets, 1.8 gpm showerheads, and faucet flow rates.
Rule for studying: learn the 2015 UPC with the 2015-cycle amendments for the exam. Know the current field numbers so you are not confused on the job.
What Washington Does Not Adopt (WAC 51-56-003 and Chapter Amendments)
- Not adopted What governs instead
- Chapter 12, Fuel Gas Piping The fuel gas provisions of the mechanical code
- Chapter 14, Firestop Protection The building code (WA 312.7)
Chapter 5 venting and combustion air (506.1–506.9, 507.6–507.9, 507.16, 507.18–507.22, 509, 510, 511) The Mechanical Code
Building sewers: Chapter 7 Part II, Sections 713–723 and Tables 717.1 and 721.1 Local sewer and health authorities
- Table 422.1 and Sections 422.1–422.5 (fixture counts) Building Code Chapter 29 and Table 2902.1
- 415.2 Drinking fountain alternatives Building Code Chapter 29
- 1502 Gray water systems Department of Health rules
- 908.2.4 (water closet position on a horizontal wet vent) No restriction
- 612.2–612.7.2 Residential fire sprinklers IBC or IRC (WA 612.1)
- 1105 Controlled-flow roof drainage Not adopted
- Appendices other than A, B, and I Not adopted
- Key Changes, Chapter by Chapter
- Chapter Washington rule Guide section
- 1 102.1 deleted; 103.3.1 state certification rules (RCW 18.106) apply 1.1, 1.2
2 Hot water is 100°F or more ; plumbing system includes water heaters and medical gas within property lines, with no certification needed outside the building; BAT is DOH-certified 10.3
3 301.3 alternates: denials in writing; 312.6 insulate hot and cold pipes outside conditioned space (2015: R-3); 312.7 penetrations per building code 1.3
4 402.5 clearances 24 in , 21 in in dwelling and sleeping units; 405.4 fixtures sold or installed must meet Chapter 4; 407.2 faucets 2.5 gpm , public lavatories 0.5 gpm ; 407.4 metering faucets in public restrooms; 408.2 showerheads 2.5 gpm (2015 cycle); 408.4 tub-to-shower 1-1/2-inch exception; 408.6 shower 900 sq in plus 30-inch circle; 411.2 water closets 1.6 gpf ; 412.1 urinals 1.0 gpf ; 414.3 dishwasher air gaps; 418.3 floor drain locations 2.1–2.4
5 Table 501.1 first hour ratings 42–80 gal ; 504.1 bedroom and bathroom closets; 505.2 non-gas heaters need an overtemperature device and T&P; 507.2 seismic straps for all heaters , 4 in from controls; 507.13 garage 18 in including ignition sources 3.1–3.4
6 603.1 DOH-approved assemblies; 603.2 maintenance and BAT testing; 603.4.2 test at installation and annually ; 603.5.6 irrigation DC only with purveyor and AHJ approval; 603.5.10 boilers air gap or RP ; 603.5.12 carbonators RP ; 604.14 plastic service termination; 606.5 manifolds; 608.3 expansion tanks (instantaneous exempt); 608.5 T&P discharge list with replacement exception; 609.9 disinfection 50 ppm for 24 hr or 200 ppm for 3 hr ; 609.11 insulation per the energy code; 611.1 Group A water system note; 612.1 sprinklers per IBC or IRC 1.2, 3.2, 3.4, 4.1–4.4, 5.1–5.4, 13.3
7 701.2 material limits; Table 703.2 note 4 exception ( four 1.6 gpf water closets on 3-inch horizontal in single-family additions, AHJ approval); 704.3 direct connection; 707.4 cleanout locations; 707.9 clearances 12 and 18 in, 20 ft 6.1–6.4, 7.1
9 903.1 vent material limits; 911.1 circuit venting: 8 fixtures, no restaurant kitchen equipment , back-outlet water closet exception 8.1, 8.3
15 1501.1.1 no reclaimed water indoors in dwellings where residents can reach the plumbing; 1501.7 and 1504.7 Class A reclaimed quality for flushing; 1501.11.2.3 cross-connection discovery procedure; 1503.4 air-gap makeup 10.1
16 1602.1 AHJ approval (exterior irrigation piping excepted); 1601.11.1 abandoned parts not reused for potable water; 1602.11.2.3 discovery procedure 10.2
How These Amendments Show Up on the Exam
Direct recall: "What is the minimum clear space in front of a water closet in a Washington apartment?" Answer: 21 inches .
Trap answers: an option quoting the unamended UPC value, such as 1,024 square inches for a shower or 18 inches of cleanout clearance, is the wrong answer in Washington.
"Not adopted" questions: "Where do Washington fixture counts come from?" Answer: Building Code Table 2902.1 .
Drawing effects: the note 4 exception and the cleanout amendments change Part 2 answers only in the situations they describe. Read the drawing notes for single-family addition language.
A 60-Second Memory Drill
21/24, 900, 12/18/20, 100°F, 4-inch strap gap, 18-inch garage, 50/24 or 200/3, air gap or RP for boilers, RP for carbonators, 8 circuit fixtures, no kitchen equipment, no sewers, no Chapter 12, no Table 422.1, no gray water. Each phrase maps to one row of the tables above.