1.1 The WELL Building Standard & Project Typologies 1.2 The WELL Certification Journey & Documentation 1.3 Scoring Rules, Preconditions & Certification Levels 1.4 Performance Verification, On-Site Testing & Recertification 1.5 Precertification, Mid-Cycle Reviews & the WELL Ratings Family 1.6 WELL Portfolio & WELL at Scale: Scope, Documentation Scales & Score
2 Chapter 2: Air — Indoor Air Quality, Ventilation, Filtration & Contaminant Control
2.1 Air Quality Thresholds (A01) & Smoke-Free Environments (A02) 2.2 Ventilation Design (A03), Enhanced Ventilation Design (A06) & Air Quality Monitoring (A08) 2.3 Construction Pollution Management (A04), Pollution Infiltration (A09) & Air Filtration (A12) 2.4 Enhanced Air Quality (A05), Enhanced Supply Air (A13) & Microbe and Mold Control (A14) 2.5 Operable Windows (A07), Combustion Minimization (A10) & Source Separation (A11)
3 Chapter 3: Water — Quality Thresholds, Legionella Management, Moisture & Hygiene
3.1 Water Quality Indicators (W01) & Drinking Water Quality (W02) 3.2 Basic Water Management (W03): Ongoing Monitoring & Legionella Plans 3.3 Enhanced Water Quality (W04), Drinking Water Quality Management (W05) & Drinking Water Promotion (W06) 3.4 Moisture Management (W07) & Hygiene Support (W08)
4 Chapter 4: Nourishment — Availability, Transparency, Portioning & Sourcing
4.1 Fruits and Vegetables (N01) & Nutritional Transparency (N02) 4.2 Refined Ingredients (N03), Food Advertising (N04), Artificial Ingredients (N05) & Portion Sizes (N06) 4.3 Nutrition Education (N07), Mindful Eating (N08) & Food Preparation (N10) 4.4 Special Diets (N09), Responsible Food Sourcing (N11), Food Production (N12) & Local Food Environment (N13)
5 Chapter 5: Light — Light Exposure, Visual Acuity, Circadian Design & Daylight
5.1 Light Exposure (L01) & Visual Lighting Design (L02) 5.2 Circadian Lighting Design (L03): EML, M-EDI and the Enhanced Daylight Trade 5.3 Electric Light Glare Control (L04), Visual Balance (L07) & Electric Light Quality (L08) 5.4 Daylight Design Strategies (L05), Daylight Simulation (L06) & Occupant Lighting Control (L09)
6 Chapter 6: Movement — Active Design, Ergonomics, Site Selection & Activity Programs
6.1 Active Buildings and Communities (V01) & Circulation Network (V03) 6.2 Ergonomic Workstation Design (V02), Active Furnishings (V07) & Self-Monitoring (V10) 6.3 Physical Activity Opportunities (V06), Spaces and Equipment (V08) & Promotion (V09) 6.4 Facilities for Active Occupants (V04) & Site Planning and Selection (V05)
7 Chapter 7: Thermal Comfort — Performance, Zoning, Individual Control & Humidity
7.1 Thermal Performance (T01) & Verified Thermal Comfort (T02) 7.2 Thermal Zoning (T03), Radiant Thermal Comfort (T05) & Thermal Comfort Monitoring (T06) 7.3 Individual Thermal Control (T04) & Humidity Control (T07)
8 Chapter 8: Sound — Acoustic Zoning, Noise Limits, Isolation & Masking
8.1 Sound Mapping (S01) & Maximum Noise Levels (S02) 8.2 Sound Barriers (S03) & Minimum Background Sound (S06) 8.3 Reverberation Time (S04) & Sound Reducing Surfaces (S05)
9 Chapter 9: Materials — Restrictions, Hazard Management, VOCs, Transparency & Cleaning
9.1 Material Restrictions (X01) & Enhanced Material Restrictions (X05) 9.2 Interior Hazardous Materials Management (X02), CCA and Lead Management (X03) & Site Remediation (X04) 9.3 VOC Restrictions (X06), Materials Transparency (X07) & Materials Optimization (X08) 9.4 Waste Management (X09), Pest Management and Pesticide Use (X10) & Cleaning Products and Protocols (X11)
10 Chapter 10: Mind — Mental Health, Nature and Place, Restoration & Substance Use
10.1 Mental Health Promotion (M01), Services (M03) & Education (M04) 10.2 Nature and Place (M02) & Enhanced Access to Nature (M09) 10.3 Restorative Opportunities (M06), Restorative Spaces (M07) & Restorative Programming (M08) 10.4 Stress Management (M05), Tobacco Cessation (M10) & Substance Use Services (M11)
11 Chapter 11: Community — Health Promotion, Integrative Design, Emergency Preparedness & Equity
11.1 Health and Wellness Promotion (C01), Integrative Design (C02) & Enhanced Promotion (C07) 11.2 Emergency Preparedness (C03) & Emergency Resources (C14) 11.3 Occupant Survey (C04), Enhanced Occupant Survey (C05) & Diversity and Inclusion (C12) 11.4 Health Services and Benefits (C06), New Parent Support (C08), New Mother Support (C09), Family Support (C10), Civic Engagement (C11) & Accessibility (C13)
12 Chapter 12: Innovation, WELL Core Applicability & Exam Strategy
12.1 Innovation Features (I01–I05), Alternative Adherence Paths & Equivalencies 12.2 WELL Core Applicability, Multifamily Residential & Sector-Specific Space Types 12.3 WELL AP Exam Mastery: Format, Domain Weights, Embedded Content & Test-Day Strategy
12.2 WELL Core Applicability, Multifamily Residential & Sector-Specific Space Types
Key Takeaways Explain This Topic AI
WELL Core features are met according to four applicability scopes: the whole building, non-leased spaces, the extent of developer buildout, or for direct staff.
Many WELL Core features offer one additional point for meeting the requirement inside tenant or leased spaces, and that extra point counts against the 12-point concept cap.
WELL Core requires at least 2.5% of total building floor area available for performance testing, including all common areas and spaces under building management control, supplemented with tenant space if needed.
Where a WELL Core building has no direct staff and no contracted staff, direct-staff preconditions are considered met but direct-staff optimizations cannot be pursued.
WELL v2 designates every part for specific space types, and requirements marked for all spaces apply project-wide while space-type requirements are either additive to or substituted for them.
Last updated: September 2026
12.2 WELL Core Applicability, Multifamily Residential & Sector-Specific Space Types
Core Exam Takeaway: WELL Core is not "WELL with fewer features" — it is WELL with different scopes, different point values, and an extra-point mechanism . Memorize the four applicability designations (whole building / non-leased spaces / extent of developer buildout / direct staff), the 2.5% testing area rule, and the multifamily dwelling-unit testing rule (Bronze and Silver without unit testing; Gold and Platinum require it).
1. The four WELL Core applicability scopes
Every WELL Core feature is met at one of four scopes, and being able to identify which one applies is a recurring Application-level exam skill:
Scope Definition WELL's example
Whole building All areas within the project boundary. The project must facilitate tenant achievement in leased spaces . A03 Part 1 Ensure Adequate Ventilation — though if using mechanical or mixed-mode ventilation, the project must provide leased spaces with sufficient outdoor air but is not required to install ducts and diffusers within leased spaces
Non-leased spaces All areas within the boundary not considered leased space — common areas and spaces under owner control L02 Part 1 Provide Visual Acuity, applied to lighting in common spaces, lobby entrance, reception, staircases and pathways
Extent of developer buildout All non-leased space plus all construction within leased space for which the project owner team is responsible W08 Part 3 Support Effective Handwashing — met in bathrooms located in non-leased spaces, and also in leased-space bathrooms if the developer built them
Direct staff Building staff under direct employment by the project owner V09 Part 1 Offer Physical Activity Incentives, earned by providing incentives to employed direct staff
The direct staff rules — three cases worth memorizing
There must be at least one direct staff member serving the project who spends no less than 30 hours per month in the building in order to pursue direct-staff features. The direct staff member is not required to have a permanent workstation in the project building.
If a project has no direct staff on-site but does have sub-contracted staff (e.g., for building management), the project may earn points by meeting requirements for all or a defined subset of building management staff .
If a project has no direct staff and no contracted staff — for example where tenants are responsible for operations and maintenance — direct-staff preconditions are considered "met," but direct-staff optimizations cannot be pursued.
Important
Case 3 is the trap: a base building with no staff at all does not fail its preconditions, but it also forfeits the corresponding optimization points. And note the general rule that projects must use a single consistent population across all features, including preconditions — a project may only earn a point for a building-management-staff optimization if it also meets all preconditions for that same group of people.
2. WELL Core point values and the extra-point rule
Important
WELL Core projects have different point values for parts and features than owner-occupied projects , based on the extent to which requirements benefit all occupants within the project. Features that must be met for the whole building are generally worth more for WELL Core , while features with no or limited effect on tenants are generally reduced in value.
Examples from the standard illustrate the spread:
- Feature WELL Certification WELL Core Why
- A06 Enhanced Ventilation Design 3 5 Whole-building benefit
- V03 Circulation Network 3 6 Whole-building benefit
- M09 Enhanced Access to Nature 2 4 Whole-building benefit
- A11 Source Separation 1 0.5 Non-leased spaces only
- A08 Air Quality Monitoring and Awareness 2 1.5 Non-leased spaces only
- L09 Occupant Lighting Control 3 1.5 Limited tenant effect
- The extra-point rule
For many features, a WELL Core project earns one additional point by also meeting the requirement within tenant or leased space — or, where no non-leased area exists for the feature to apply, by applying the feature in leased areas. WELL's own example is L02 Part 1 , applicable to non-leased spaces, where extending visual acuity requirements into leased spaces earns one extra point.
Warning
The extra point counts against the 12-point concept cap. WELL Core guidance states that projects may earn no more than 12 points per concept including any extra points achieved . A Core project that maximizes tenant-space extensions in a single concept can therefore waste effort.
Two more Core-specific mechanisms
Performance testing area: at least 2.5% of total building floor area must be available for testing, and the available area must include all common areas and spaces directly under building management control . If those comprise less than 2.5%, the project supplements with tenant spaces , and testing in leased space may occur before or after tenant occupancy . Some performance-based optimizations explicitly require testing in tenant spaces to be awarded.
Tenant exclusions: several features permit up to 10% of total tenant-occupied area to be excluded from feature scope — A12, A13, A14 and T05 all carry this allowance — while others (A05, L01 Option 4, L02, L03, T07) instead require access to at least 10% of leased space for testing .
3. Multifamily Residential
Multifamily residential projects use the WELL Certification pathway, never WELL Core , even though most regular occupants are tenants and the owner may not complete the dwelling-unit fit-out. Eligibility requires at least five dwelling units in a single building with common structural elements , across all market thresholds including affordable, market-rate and luxury housing.
The dwelling-unit testing rule — the concept's single most examinable fact
- Target level Precondition testing inside dwelling units Optimization testing inside dwelling units
- Bronze Not required Required
- Silver Not required Required
- Gold Required (a sample of units) Required
- Platinum Required (a sample of units) Required
- At recertification, any level Not required — only common areas and spaces dedicated to building management —
The features carrying the note are A01 (Air Quality) , W01 (Water Quality Indicators) , W02 (Drinking Water Quality) , L02 (Visual Lighting Design) and T01 (Thermal Performance) ; sampling rates are in the WELL Performance Verification Guidebook .
Dwelling-unit-specific requirements elsewhere in the standard
Many features carry a distinct "For Dwelling Units" scope, and knowing where they diverge is worth several marks:
Feature Dwelling-unit-specific requirement
A11 Source Separation Range hood exhaust vented directly outdoors , outlets ≥ 10 ft (3 m) from air intakes, greater of 100 cfm per linear foot or 200 cfm , hood covering ≥ 75% of burner area
W02 Drinking Water Quality One drinking water dispenser per dwelling unit , in addition to the project's first
L01 / L03 / L05 / L06 Glazing at 7% of regularly occupied floor area (L01 Option 2); L03 levels at 55 in (140 cm) centre of living rooms and kitchens, dimmable , auto-dimmed after 8:00 pm
- N10 Food Preparation Countertop, sink, refrigerator, cabinets, stove with hood vented directly outdoors
- N12 Food Production 15 ft² (1.4 m²) per dwelling unit , capped at 1,500 ft², floor of 200 ft²
- S02 Maximum Noise Levels Bedroom background noise ≤ 35 dBA over a 12-hour minimum including 10 pm–7 am
- V04 Facilities for Active Occupants Long-term bike parking for ≥ 30% of regular occupants
- 4. Space types — how one feature part becomes several requirements
All parts of WELL v2 are designated for specific space types , and space types refer to spaces within a project, not the project as a whole . A school comprises classrooms, offices, a commercial kitchen and dining areas — four space types inside one project.
Parts marked "for all spaces" apply to all spaces within the project boundary, for all project types .
Space-type requirements are either required in addition to the "all spaces" requirements, or used in place of them — and the feature language says which.
WELL's own worked examples make the distinction concrete:
N01 Part 1 has separate requirements for dining spaces and all other spaces, indicated by the tab "For All Spaces except Dining Spaces" — the dining requirement replaces the general one.
N01 Part 2 has one set of requirements "For All Spaces" including dining spaces, plus additional requirements "For Dining Spaces" only — here the dining requirement is additive .
Space types that carry their own thresholds across the standard
Space type Where it changes the requirement
Commercial kitchen spaces A01 (PM2.5 ≤ 35 µg/m³, CO ≤ 34 mg/m³ / 30 ppm), A10 (excluded from combustion ban), A11 (hood geometry), T01 (operative temperature ≤ 80 °F / 27 °C), T04 Parts 2 and 3 (excluded)
Commercial dining spaces N01 (four fruits and four vegetables; menu design), N02 (menu calories, allergen training, sugar labeling), N06 (650 Cal and dishware)
Office spaces V02 Parts 1–3 (visual ergonomics, height-adjustable surfaces, chair adjustability), V07 (active workstations), S06 Part 1 (sound masking), C05 Part 1 (enhanced survey)
- Retail spaces V04 (bike parking per 5,000 ft²), M10 Part 2 (tobacco sale and marketing ban)
- Industrial A01 (kitchen/industrial thresholds), L04 (UGR ≤ 19 rather than 16), S02 (excluded)
- Dwelling units See the table above
- Circulation areas L08 Part 1 (relaxed colour rendering: CRI ≥ 80 with no R9 condition)
Primary and secondary schools N10 (on-site meal preparation), N06 and S05 (student dishware and acoustics), V06 and V09 (student activity provisions), M06 Part 1 Option 3 ( 8:30 a.m. start)
Tip
The exam's Application-level questions are frequently built exactly here: you are given a project type and a space type and asked which threshold governs. The reliable method is to identify (1) the project pathway — owner-occupied, WELL Core, or multifamily residential — then (2) the space type , then (3) whether the space-type requirement adds to or replaces the "all spaces" requirement . Answering in that order resolves most scenario items.