Study guide
9.1 Material Restrictions (X01) & Enhanced Material Restrictions (X05)
WELL Accredited Professional WELL AP
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: WELL Certification Process, Project Typologies & Scoring
1.1 The WELL Building Standard & Project Typologies 1.2 The WELL Certification Journey & Documentation 1.3 Scoring Rules, Preconditions & Certification Levels 1.4 Performance Verification, On-Site Testing & Recertification 1.5 Precertification, Mid-Cycle Reviews & the WELL Ratings Family 1.6 WELL Portfolio & WELL at Scale: Scope, Documentation Scales & Score
2 Chapter 2: Air — Indoor Air Quality, Ventilation, Filtration & Contaminant Control
2.1 Air Quality Thresholds (A01) & Smoke-Free Environments (A02) 2.2 Ventilation Design (A03), Enhanced Ventilation Design (A06) & Air Quality Monitoring (A08) 2.3 Construction Pollution Management (A04), Pollution Infiltration (A09) & Air Filtration (A12) 2.4 Enhanced Air Quality (A05), Enhanced Supply Air (A13) & Microbe and Mold Control (A14) 2.5 Operable Windows (A07), Combustion Minimization (A10) & Source Separation (A11)
3 Chapter 3: Water — Quality Thresholds, Legionella Management, Moisture & Hygiene
3.1 Water Quality Indicators (W01) & Drinking Water Quality (W02) 3.2 Basic Water Management (W03): Ongoing Monitoring & Legionella Plans 3.3 Enhanced Water Quality (W04), Drinking Water Quality Management (W05) & Drinking Water Promotion (W06) 3.4 Moisture Management (W07) & Hygiene Support (W08)
4 Chapter 4: Nourishment — Availability, Transparency, Portioning & Sourcing
4.1 Fruits and Vegetables (N01) & Nutritional Transparency (N02) 4.2 Refined Ingredients (N03), Food Advertising (N04), Artificial Ingredients (N05) & Portion Sizes (N06) 4.3 Nutrition Education (N07), Mindful Eating (N08) & Food Preparation (N10) 4.4 Special Diets (N09), Responsible Food Sourcing (N11), Food Production (N12) & Local Food Environment (N13)
5 Chapter 5: Light — Light Exposure, Visual Acuity, Circadian Design & Daylight
5.1 Light Exposure (L01) & Visual Lighting Design (L02) 5.2 Circadian Lighting Design (L03): EML, M-EDI and the Enhanced Daylight Trade 5.3 Electric Light Glare Control (L04), Visual Balance (L07) & Electric Light Quality (L08) 5.4 Daylight Design Strategies (L05), Daylight Simulation (L06) & Occupant Lighting Control (L09)
6 Chapter 6: Movement — Active Design, Ergonomics, Site Selection & Activity Programs
6.1 Active Buildings and Communities (V01) & Circulation Network (V03) 6.2 Ergonomic Workstation Design (V02), Active Furnishings (V07) & Self-Monitoring (V10) 6.3 Physical Activity Opportunities (V06), Spaces and Equipment (V08) & Promotion (V09) 6.4 Facilities for Active Occupants (V04) & Site Planning and Selection (V05)
7 Chapter 7: Thermal Comfort — Performance, Zoning, Individual Control & Humidity
7.1 Thermal Performance (T01) & Verified Thermal Comfort (T02) 7.2 Thermal Zoning (T03), Radiant Thermal Comfort (T05) & Thermal Comfort Monitoring (T06) 7.3 Individual Thermal Control (T04) & Humidity Control (T07)
8 Chapter 8: Sound — Acoustic Zoning, Noise Limits, Isolation & Masking
8.1 Sound Mapping (S01) & Maximum Noise Levels (S02) 8.2 Sound Barriers (S03) & Minimum Background Sound (S06) 8.3 Reverberation Time (S04) & Sound Reducing Surfaces (S05)
9 Chapter 9: Materials — Restrictions, Hazard Management, VOCs, Transparency & Cleaning
9.1 Material Restrictions (X01) & Enhanced Material Restrictions (X05) 9.2 Interior Hazardous Materials Management (X02), CCA and Lead Management (X03) & Site Remediation (X04) 9.3 VOC Restrictions (X06), Materials Transparency (X07) & Materials Optimization (X08) 9.4 Waste Management (X09), Pest Management and Pesticide Use (X10) & Cleaning Products and Protocols (X11)
10 Chapter 10: Mind — Mental Health, Nature and Place, Restoration & Substance Use
10.1 Mental Health Promotion (M01), Services (M03) & Education (M04) 10.2 Nature and Place (M02) & Enhanced Access to Nature (M09) 10.3 Restorative Opportunities (M06), Restorative Spaces (M07) & Restorative Programming (M08) 10.4 Stress Management (M05), Tobacco Cessation (M10) & Substance Use Services (M11)
11 Chapter 11: Community — Health Promotion, Integrative Design, Emergency Preparedness & Equity
11.1 Health and Wellness Promotion (C01), Integrative Design (C02) & Enhanced Promotion (C07) 11.2 Emergency Preparedness (C03) & Emergency Resources (C14) 11.3 Occupant Survey (C04), Enhanced Occupant Survey (C05) & Diversity and Inclusion (C12) 11.4 Health Services and Benefits (C06), New Parent Support (C08), New Mother Support (C09), Family Support (C10), Civic Engagement (C11) & Accessibility (C13)
12 Chapter 12: Innovation, WELL Core Applicability & Exam Strategy
12.1 Innovation Features (I01–I05), Alternative Adherence Paths & Equivalencies 12.2 WELL Core Applicability, Multifamily Residential & Sector-Specific Space Types 12.3 WELL AP Exam Mastery: Format, Domain Weights, Embedded Content & Test-Day Strategy
9.1 Material Restrictions (X01) & Enhanced Material Restrictions (X05)
Key Takeaways Explain This Topic AI
X01 Part 1 requires nine listed product categories not to contain over 1,000 ppm of asbestos by weight or area, including thermal protection, acoustic treatments, roofing, ceilings and resilient flooring.
X01 Part 2 requires newly installed fluorescent and sodium lamps to meet RoHS restrictions or tabulated mercury limits, and newly installed fire alarms, meters, sensors, relays, thermostats and load break switches to meet RoHS or 0.1% mercury by weight.
X01 Part 3 restricts lead in the same electrical devices to RoHS or 0.01% (100 ppm) by weight, and requires newly installed paints to meet one of four lead criteria.
X05 Enhanced Material Restrictions is worth 2 points and requires at least 50% by cost of newly installed products in defined categories, with a minimum of 10 distinct products, to meet 100 ppm limits.
X05 targets halogenated flame retardants, PFAS, lead, cadmium and mercury in textiles and plastics, and HFRs, PFAS and orthophthalates in flooring, insulation, panels and plastic plumbing.
Last updated: September 2026
9.1 Material Restrictions (X01) & Enhanced Material Restrictions (X05)
Core Exam Takeaway: Materials has three preconditions (X01, X02, X03) and eight optimizations (X04–X11) , and carries 9 scored exam questions . X01 Material Restrictions restricts exactly three substances in newly installed products — asbestos, mercury, lead . X05 Enhanced Material Restrictions (2 pt) adds HFRs, PFAS, orthophthalates, cadmium at 100 ppm , across 50% by cost, minimum 10 distinct products . There is also a beta feature X12 Contact Reduction , which is not assessable .
The concept's two halves
Materials divides cleanly, and knowing which half a feature sits in prevents most numbering errors:
Half Question it answers Features
What you bring in Are newly installed products free of hazardous ingredients, and do we know what is in them? X01, X05, X06, X07, X08
What is already there, and what you do daily Are legacy hazards and operational chemicals managed? X02, X03, X04, X09, X10, X11
The "newly installed products" scoping rule
This is essential to X01 and X05 and is stated in WELL's general guidance: the requirements of some features apply to products installed after project registration. Two consequences:
Preconditions have no minimum scope. A project that installs no lamps or electronics is considered in compliance with X01's relevant parts. Nothing must be ripped out.
Optimizations do have minimum scope. X05 requires at least 10 distinct products within the category before the percentage test even applies — which stops a project from claiming the point on the strength of two chairs.
Feature X01: Material Restrictions — Precondition
Intent: reduce or eliminate human exposure to building materials known to be hazardous.
X01 Part 1 — Restrict Asbestos
For newly installed or applied products within the project boundary: the following nine product categories do not contain over 1,000 ppm of asbestos by weight or area :
- Thermal protection , including all insulation (lagging) applied to pipes, fittings, boilers, tanks and ducts
- Acoustic treatments
- Sheathing
- Roofing and siding
- Fire and smoke protection
- Joint protection
- Plaster and gypsum board
- Ceilings
- Resilient flooring
- X01 Part 2 — Restrict Mercury
(a) Newly installed fluorescent and sodium lamps , if present, meet RoHS restrictions or these limits:
- Lamp type Maximum mercury content
- Compact, integral ballast 3.5 mg
- Compact, non-integral ballast 3.5 mg
- T-5, circular 9 mg
- T-5, linear 2.5 mg
- T-8, eight-foot 10 mg
- T-8, four-foot 3.5 mg
- T-8, U-bent 6 mg
- High-pressure sodium, 400 W or less 10 mg
- High-pressure sodium, over 400 W 32 mg
(b) Newly installed fire alarms, meters, sensors, relays, thermostats and load break switches meet RoHS restrictions or contain no more than 0.1% (1,000 ppm) mercury by weight .
- X01 Part 3 — Restrict Lead
- Option 1: Paints and electronics
(a) The same device list — fire alarms, meters, sensors, relays, thermostats, load break switches — meets RoHS or contains no more than 0.01% (100 ppm) lead by weight .
(b) Newly installed paints applied as finishes meet at least one of:
- Lead concentration of 100 ppm (0.01%) by weight or below
- No added lead carbonates and lead sulfates
Deemed free of lead or with no added lead by an ISO 14024-compliant (Type 1) Ecolabel , or a voluntary third-party certification recognized by local government
Paints meet Feature X08: Materials Optimization
Option 2: Drinking water pipes, fittings and solder — newly installed or applied pipes, fixtures, fittings and solder intended for drinking water distribution.
WELL Core guidance for all parts: extent of developer buildout. +-----------------------------------------------------------------------------+
- | X01: THREE SUBSTANCES, THREE DIFFERENT THRESHOLDS |
- | |
- | ASBESTOS 1,000 ppm by weight or area, in 9 named product categories |
- | MERCURY 0.1% = 1,000 ppm by weight, in electrical devices |
- | (plus a per-lamp-type milligram table) |
- | LEAD 0.01% = 100 ppm by weight, in electrical devices AND paints |
- | |
- | Note the ten-fold difference between the MERCURY device limit (1,000 ppm) |
- | and the LEAD device limit (100 ppm) for the SAME device list. Lead is |
- | held to the stricter number. |
- +-----------------------------------------------------------------------------+
Important
The same six devices appear in both Part 2 and Part 3 — fire alarms, meters, sensors, relays, thermostats and load break switches — but the thresholds differ by a factor of ten: 0.1% (1,000 ppm) for mercury , 0.01% (100 ppm) for lead . Both parts accept RoHS compliance as a shortcut, which is why specifying RoHS-compliant devices satisfies the whole of X01 Parts 2(b) and 3(a) in one stroke.
Tip
X01 Part 3(b)(4) is a cross-reference worth noticing: a paint that meets X08 Materials Optimization automatically satisfies the lead criterion. WELL builds these shortcuts deliberately — a product screened against the Living Building Challenge Red List or the Cradle to Cradle Restricted Substances List has already been screened for lead.
Feature X05: Enhanced Material Restrictions — Optimization (2 pt / WELL Core 2 pt)
Intent: minimize exposure to certain chemicals by limiting their presence in products.
X05 Part 1 — Select Compliant Interior Furnishings (1 pt / Core 1 pt)
Option 1: Furniture, millwork and fixtures. At least 50% by cost of newly installed furniture, millwork and fixtures ( minimum 10 distinct products , as defined in Appendix X1) meet one of:
(a) Textiles (fabrics including upholstery) and plastics contain 100 ppm (0.01%) by weight or less of these five compound classes, unless higher amounts are mandated by local codes :
- Halogenated flame retardants (HFR)
- Per- and polyfluoroalkyl substances (PFAS)
- Lead
- Cadmium
- Mercury
For assessing compliance, all pieces of each of the two material categories (textiles, plastics) are grouped together and each is assessed independently against the 100 ppm threshold.
(b) The products do not contain textiles and plastic at all.
Option 2: Electrical and electronic products. All newly installed electrical and electronic products specified in Appendix X1 are compliant with RoHS restrictions .
X05 Part 2 — Select Compliant Architectural and Interior Products (1 pt / Core 1 pt)
At least 50% by cost of newly installed products in the classes below ( minimum 10 distinct products ), meet these 100 ppm (0.01%) by weight limits, unless higher amounts are mandated by local code:
- Product class Restricted to ≤ 100 ppm
- Flooring HFR , PFAS , orthophthalates
- Insulation — thermal and acoustic in walls, ceilings, ducts, tubes and pipes HFR
- Ceiling and wall panels HFR , orthophthalates
- Plastic plumbing orthophthalates
WELL Core guidance for both parts: extent of developer buildout.
Important
Memorize the pattern, not each cell. HFRs appear in all four product classes because flame-retardant treatment is ubiquitous in flooring, insulation and panels. Orthophthalates appear wherever flexible PVC does — flooring, panels, plastic plumbing — because they are the plasticizers that make PVC flexible. PFAS appear where stain and water repellency is sold — textiles and flooring. Reasoning from function gets you the right answer faster than rote recall.
Why these four chemical classes
Class Where it is used Health concern
Halogenated flame retardants (HFR) Foam, textiles, insulation, plastics, electronics casings Persistent and bioaccumulative; endocrine disruption and developmental neurotoxicity associated with several congeners; they migrate out of products into dust
PFAS Stain-, water- and grease-repellent treatments on textiles and flooring Extreme environmental persistence ("forever chemicals"); immune, thyroid and developmental effects
Orthophthalates Plasticizers in flexible PVC — flooring, wall panels, plumbing Endocrine disruption, particularly anti-androgenic effects on reproductive development
Heavy metals — lead, cadmium, mercury Pigments, stabilizers, electronics Neurotoxicity (lead, mercury), renal and skeletal toxicity (cadmium)
Note that all four classes share a dust pathway : they are not strongly volatile, so they leave products as semi-volatile compounds and particulate that settle into dust and are ingested or absorbed dermally — especially by crawling children. That is why WELL restricts them in products rather than setting an air concentration threshold as it does for VOCs in A01 and X06 .
Tip
"50% by cost" and "minimum 10 distinct products" travel together throughout X05, X06 Part 2, X07 and X08. Cost-weighting stops a project from satisfying the requirement with cheap trivia while installing an expensive non-compliant floor; the product-count floor stops a tiny project from claiming a materials point on almost no material at all.