Study guide

8.3 Reverberation Time (S04) & Sound Reducing Surfaces (S05)

WELL Accredited Professional WELL AP

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: WELL Certification Process, Project Typologies & Scoring

1.1 The WELL Building Standard & Project Typologies 1.2 The WELL Certification Journey & Documentation 1.3 Scoring Rules, Preconditions & Certification Levels 1.4 Performance Verification, On-Site Testing & Recertification 1.5 Precertification, Mid-Cycle Reviews & the WELL Ratings Family 1.6 WELL Portfolio & WELL at Scale: Scope, Documentation Scales & Score

2 Chapter 2: Air — Indoor Air Quality, Ventilation, Filtration & Contaminant Control

2.1 Air Quality Thresholds (A01) & Smoke-Free Environments (A02) 2.2 Ventilation Design (A03), Enhanced Ventilation Design (A06) & Air Quality Monitoring (A08) 2.3 Construction Pollution Management (A04), Pollution Infiltration (A09) & Air Filtration (A12) 2.4 Enhanced Air Quality (A05), Enhanced Supply Air (A13) & Microbe and Mold Control (A14) 2.5 Operable Windows (A07), Combustion Minimization (A10) & Source Separation (A11)

3 Chapter 3: Water — Quality Thresholds, Legionella Management, Moisture & Hygiene

3.1 Water Quality Indicators (W01) & Drinking Water Quality (W02) 3.2 Basic Water Management (W03): Ongoing Monitoring & Legionella Plans 3.3 Enhanced Water Quality (W04), Drinking Water Quality Management (W05) & Drinking Water Promotion (W06) 3.4 Moisture Management (W07) & Hygiene Support (W08)

4 Chapter 4: Nourishment — Availability, Transparency, Portioning & Sourcing

4.1 Fruits and Vegetables (N01) & Nutritional Transparency (N02) 4.2 Refined Ingredients (N03), Food Advertising (N04), Artificial Ingredients (N05) & Portion Sizes (N06) 4.3 Nutrition Education (N07), Mindful Eating (N08) & Food Preparation (N10) 4.4 Special Diets (N09), Responsible Food Sourcing (N11), Food Production (N12) & Local Food Environment (N13)

5 Chapter 5: Light — Light Exposure, Visual Acuity, Circadian Design & Daylight

5.1 Light Exposure (L01) & Visual Lighting Design (L02) 5.2 Circadian Lighting Design (L03): EML, M-EDI and the Enhanced Daylight Trade 5.3 Electric Light Glare Control (L04), Visual Balance (L07) & Electric Light Quality (L08) 5.4 Daylight Design Strategies (L05), Daylight Simulation (L06) & Occupant Lighting Control (L09)

6 Chapter 6: Movement — Active Design, Ergonomics, Site Selection & Activity Programs

6.1 Active Buildings and Communities (V01) & Circulation Network (V03) 6.2 Ergonomic Workstation Design (V02), Active Furnishings (V07) & Self-Monitoring (V10) 6.3 Physical Activity Opportunities (V06), Spaces and Equipment (V08) & Promotion (V09) 6.4 Facilities for Active Occupants (V04) & Site Planning and Selection (V05)

7 Chapter 7: Thermal Comfort — Performance, Zoning, Individual Control & Humidity

7.1 Thermal Performance (T01) & Verified Thermal Comfort (T02) 7.2 Thermal Zoning (T03), Radiant Thermal Comfort (T05) & Thermal Comfort Monitoring (T06) 7.3 Individual Thermal Control (T04) & Humidity Control (T07)

8 Chapter 8: Sound — Acoustic Zoning, Noise Limits, Isolation & Masking

8.1 Sound Mapping (S01) & Maximum Noise Levels (S02) 8.2 Sound Barriers (S03) & Minimum Background Sound (S06) 8.3 Reverberation Time (S04) & Sound Reducing Surfaces (S05)

9 Chapter 9: Materials — Restrictions, Hazard Management, VOCs, Transparency & Cleaning

9.1 Material Restrictions (X01) & Enhanced Material Restrictions (X05) 9.2 Interior Hazardous Materials Management (X02), CCA and Lead Management (X03) & Site Remediation (X04) 9.3 VOC Restrictions (X06), Materials Transparency (X07) & Materials Optimization (X08) 9.4 Waste Management (X09), Pest Management and Pesticide Use (X10) & Cleaning Products and Protocols (X11)

10 Chapter 10: Mind — Mental Health, Nature and Place, Restoration & Substance Use

10.1 Mental Health Promotion (M01), Services (M03) & Education (M04) 10.2 Nature and Place (M02) & Enhanced Access to Nature (M09) 10.3 Restorative Opportunities (M06), Restorative Spaces (M07) & Restorative Programming (M08) 10.4 Stress Management (M05), Tobacco Cessation (M10) & Substance Use Services (M11)

11 Chapter 11: Community — Health Promotion, Integrative Design, Emergency Preparedness & Equity

11.1 Health and Wellness Promotion (C01), Integrative Design (C02) & Enhanced Promotion (C07) 11.2 Emergency Preparedness (C03) & Emergency Resources (C14) 11.3 Occupant Survey (C04), Enhanced Occupant Survey (C05) & Diversity and Inclusion (C12) 11.4 Health Services and Benefits (C06), New Parent Support (C08), New Mother Support (C09), Family Support (C10), Civic Engagement (C11) & Accessibility (C13)

12 Chapter 12: Innovation, WELL Core Applicability & Exam Strategy

12.1 Innovation Features (I01–I05), Alternative Adherence Paths & Equivalencies 12.2 WELL Core Applicability, Multifamily Residential & Sector-Specific Space Types 12.3 WELL AP Exam Mastery: Format, Domain Weights, Embedded Content & Test-Day Strategy

8.3 Reverberation Time (S04) & Sound Reducing Surfaces (S05)

Key Takeaways Explain This Topic AI

Both S04 and S05 apply only where the listed space types cumulatively make up at least 10% of occupiable project area.

S04 caps reverberation time at 0.6 seconds for learning and conferencing areas under 10,000 ft3 (280 m3), with wider bands as volume increases.

S04 sets 0.8 to 1.0 seconds for areas for speech, and no more than 1.0 second for dining areas and regularly occupied areas with public address systems.

S05 awards 1 point for minimum NRC of 0.75 across at least 75% of available ceiling area in open workspaces, and 2 points for 0.90 across all available ceiling area.

The S05 2-point tier for open workspaces also requires partial height barriers at least 4 ft (1.2 m) above finished floor with minimum NRC of 0.70 between all opposing workstations.

Last updated: September 2026

8.3 Reverberation Time (S04) & Sound Reducing Surfaces (S05)

Core Exam Takeaway: S04 Reverberation Time (2 pt / WELL Core 1 pt) and S05 Sound Reducing Surfaces (2 pt / Core 1 pt) share a crucial gating condition: both apply only where the listed space types cumulatively make up at least 10% of occupiable project area. Memorize S04's 0.6 s cap for small learning and conferencing rooms and S05's NRC 0.75 / 0.90 ladder, plus the 4 ft (1.2 m) / NRC 0.70 partial-height barrier in the 2-point tier.

Reverberation time in one paragraph

Reverberation time (RT, or RT₆₀) is the time for sound pressure to decay by 60 dB after the source stops. It is governed by room volume and total absorption — Sabine's relationship makes RT proportional to volume and inversely proportional to absorption area. Two consequences drive S04's structure: larger rooms reverberate longer for the same finishes , which is why S04's thresholds are banded by volume ; and the fix is always absorption , which is why S05 exists as a separate purchasable feature .

Note also that S04 sets ranges, not just ceilings , for several space types. Too little reverberation is also a defect — an anechoic room makes speaking exhausting, because talkers get no acoustic support and unconsciously raise vocal effort. Hence bands like 0.8 ≤ t ≤ 1.0 s for areas for speech.

Feature S04: Reverberation Time — Optimization (2 pt / WELL Core 1 pt)

Intent: design spaces in accordance with comfortable reverberation times that support speech intelligibility, vocal effort and are conducive to concentration .

S04 Part 1 — Achieve Reverberation Time Thresholds

Applicability gate: for projects in which the space types listed cumulatively make up at least 10% of occupiable project area .

Option 1: Reverberation time, design and Option 2: Reverberation time, performance use the same thresholds ; the difference is whether compliance is demonstrated by design calculation or by measurement :

  • Space type Space volume, v Reverberation time, t (seconds)
  • Areas for learning and conferencing v < 10,000 ft³ (280 m³) t ≤ 0.6
  • 10,000 ft³ (280 m³) ≤ v ≤ 20,000 ft³ (570 m³) 0.5 ≤ t ≤ 0.8
  • v > 20,000 ft³ (570 m³) 0.6 ≤ t ≤ 1.0
  • Areas for speech n/a 0.8 ≤ t ≤ 1.0
  • Areas for dining ; regularly occupied areas with public address systems n/a t ≤ 1.0
  • Areas for fitness v < 10,000 ft³ (280 m³) 0.7 ≤ t ≤ 0.8
  • 10,000 ft³ (280 m³) ≤ v ≤ 20,000 ft³ (570 m³) 0.8 ≤ t ≤ 1.1
  • v > 20,000 ft³ (570 m³) 1.0 ≤ t ≤ 1.8
  • Areas for music rehearsal v < 10,000 ft³ (280 m³) t ≤ 1.1

10,000 ft³ (280 m³) ≤ v ≤ 20,000 ft³ (570 m³) 1.0 ≤ t ≤ 1.4 +-----------------------------------------------------------------------------+

  • | S04: HOW THE THRESHOLDS MOVE, AND WHY |
  • | |
  • | As VOLUME rises, the permitted RT band rises -- Sabine's relationship |
  • | makes short RT in a large room economically brutal. |
  • | |
  • | As the room's PURPOSE shifts from LISTENING to MAKING SOUND, |
  • | the band rises too: |
  • | |
  • | learning / conferencing t <= 0.6 s (small) <-- intelligibility |
  • | areas for speech 0.8 - 1.0 s <-- support the talker |
  • | dining / PA systems t <= 1.0 s <-- keep announcements |
  • | intelligible |
  • | fitness (small) 0.7 - 0.8 s |
  • | music rehearsal (small) t <= 1.1 s <-- musicians need decay |
  • | |
  • | Note the LOWER bounds: too dead a room is also a failure. |
  • +-----------------------------------------------------------------------------+

Important

The 10% applicability gate is the most commonly missed element of both S04 and S05. A project whose learning, conferencing, speech, dining, fitness and music-rehearsal spaces together occupy less than 10% of occupiable area is not required to meet the tables in order to earn the feature. This is a scoping rule that keeps the feature proportionate — an office with one small huddle room is not asked to acoustically engineer it.

Tip

The 0.6-second cap for small learning and conferencing spaces is the single most quotable number in S04. It reflects a large speech-intelligibility literature showing that classroom comprehension — especially for children, second-language listeners and anyone with hearing loss — degrades sharply above roughly 0.6 s in typically sized rooms.

Feature S05: Sound Reducing Surfaces — Optimization (2 pt / WELL Core 1 pt)

Intent: design spaces with sound reducing surfaces to minimize the buildup of speech or other unwanted sound .

S05 Part 1 — Implement Sound Reducing Surfaces

Same applicability gate: the listed space types cumulatively make up at least 10% of occupiable project area .

Space type Metric 1 point (Core 0.5) 2 points (Core 1)

Open workspaces Minimum NRC/ α w \alpha_{\text{w}} α w ​ 0.75 for at least 75% of available ceiling area 0.90 for all available ceiling area

Minimum furniture height and NRC/ α w \alpha_{\text{w}} α w ​ n/a Partial height barriers with a minimum height of 4 ft (1.2 m) above finished floor and a minimum NRC/ α w \alpha_{\text{w}} α w ​ of 0.70 between all opposing workstations

Areas for conferencing and learning Minimum NRC/ α w \alpha_{\text{w}} α w ​ at ceilings 0.75 for at least 50% of available ceiling area 0.90 for all available ceiling area

Minimum NRC/ α w \alpha_{\text{w}} α w ​ at walls 0.75 on at least 25% of two walls 0.80 on at least 25% of two perpendicular walls

Areas for dining Minimum NRC/ α w \alpha_{\text{w}} α w ​ at ceilings 0.75 for at least 50% of available ceiling area 0.90 for all available ceiling area

WELL Core guidance: non-leased spaces; an additional point for also meeting requirements in leased spaces.

Important

Open workspaces have a stricter 1-point ceiling requirement than conferencing, learning and dining areas — 75% of available ceiling area versus 50% . Open plans have no walls to stop speech, so the ceiling is the only large absorptive surface available, and it has to work harder.

Tip

The 2-point tier for open workspaces adds a second, independent requirement. It is not enough to upgrade the ceiling to NRC 0.90 across all available area; the project must also install partial height barriers at least 4 ft (1.2 m) above finished floor with NRC of at least 0.70 between all opposing workstations . Ceiling absorption handles reflected sound; the barrier interrupts the direct line-of-sight path between facing occupants, which absorption alone cannot address.

Tip

Note "two perpendicular walls" in the 2-point conferencing tier. Treating two parallel walls leaves the perpendicular pair to sustain a flutter echo between them; treating perpendicular surfaces breaks reflection paths in both room axes. The upgrade from 1 point to 2 points here is a geometry change as much as a performance change — and the wall coverage requirement drops from NRC 0.75 to 0.80 while the geometric constraint tightens.

NRC and α w \alpha_{\text{w}} α w ​

NRC (Noise Reduction Coefficient) is the arithmetic average of a material's absorption coefficients at 250, 500, 1000 and 2000 Hz, rounded to the nearest 0.05, on a 0-to-1 scale. α w \alpha_{\text{w}} α w ​ (weighted sound absorption coefficient) is the ISO equivalent. An NRC of 0.90 means the surface absorbs roughly 90% of incident sound energy in the speech-relevant bands — which is why standard mineral-fibre acoustic tile typically sits around 0.70 and reaching 0.90 usually requires a high-performance tile, a suspended baffle array, or an exposed-structure ceiling with a dedicated absorptive layer.

How S04, S05 and S06 combine

These three features solve the same problem — speech that should not be intelligible — by three different physical mechanisms, and a project usually needs at least two of them:

  • Mechanism Feature What it does to a distant conversation
  • Absorb S05 Removes reflected energy, so only the direct path survives
  • Shorten decay S04 Stops syllables smearing into one another across the room
  • Mask S06 Raises the noise floor so the surviving speech is unintelligible

S06 Part 2 pays an extra point precisely for combining masking with either S03 isolation or S05 absorption — WELL's acknowledgement that no single mechanism is sufficient in an open plan.