Study guide

8.1 Sound Mapping (S01) & Maximum Noise Levels (S02)

WELL Accredited Professional WELL AP

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: WELL Certification Process, Project Typologies & Scoring

1.1 The WELL Building Standard & Project Typologies 1.2 The WELL Certification Journey & Documentation 1.3 Scoring Rules, Preconditions & Certification Levels 1.4 Performance Verification, On-Site Testing & Recertification 1.5 Precertification, Mid-Cycle Reviews & the WELL Ratings Family 1.6 WELL Portfolio & WELL at Scale: Scope, Documentation Scales & Score

2 Chapter 2: Air — Indoor Air Quality, Ventilation, Filtration & Contaminant Control

2.1 Air Quality Thresholds (A01) & Smoke-Free Environments (A02) 2.2 Ventilation Design (A03), Enhanced Ventilation Design (A06) & Air Quality Monitoring (A08) 2.3 Construction Pollution Management (A04), Pollution Infiltration (A09) & Air Filtration (A12) 2.4 Enhanced Air Quality (A05), Enhanced Supply Air (A13) & Microbe and Mold Control (A14) 2.5 Operable Windows (A07), Combustion Minimization (A10) & Source Separation (A11)

3 Chapter 3: Water — Quality Thresholds, Legionella Management, Moisture & Hygiene

3.1 Water Quality Indicators (W01) & Drinking Water Quality (W02) 3.2 Basic Water Management (W03): Ongoing Monitoring & Legionella Plans 3.3 Enhanced Water Quality (W04), Drinking Water Quality Management (W05) & Drinking Water Promotion (W06) 3.4 Moisture Management (W07) & Hygiene Support (W08)

4 Chapter 4: Nourishment — Availability, Transparency, Portioning & Sourcing

4.1 Fruits and Vegetables (N01) & Nutritional Transparency (N02) 4.2 Refined Ingredients (N03), Food Advertising (N04), Artificial Ingredients (N05) & Portion Sizes (N06) 4.3 Nutrition Education (N07), Mindful Eating (N08) & Food Preparation (N10) 4.4 Special Diets (N09), Responsible Food Sourcing (N11), Food Production (N12) & Local Food Environment (N13)

5 Chapter 5: Light — Light Exposure, Visual Acuity, Circadian Design & Daylight

5.1 Light Exposure (L01) & Visual Lighting Design (L02) 5.2 Circadian Lighting Design (L03): EML, M-EDI and the Enhanced Daylight Trade 5.3 Electric Light Glare Control (L04), Visual Balance (L07) & Electric Light Quality (L08) 5.4 Daylight Design Strategies (L05), Daylight Simulation (L06) & Occupant Lighting Control (L09)

6 Chapter 6: Movement — Active Design, Ergonomics, Site Selection & Activity Programs

6.1 Active Buildings and Communities (V01) & Circulation Network (V03) 6.2 Ergonomic Workstation Design (V02), Active Furnishings (V07) & Self-Monitoring (V10) 6.3 Physical Activity Opportunities (V06), Spaces and Equipment (V08) & Promotion (V09) 6.4 Facilities for Active Occupants (V04) & Site Planning and Selection (V05)

7 Chapter 7: Thermal Comfort — Performance, Zoning, Individual Control & Humidity

7.1 Thermal Performance (T01) & Verified Thermal Comfort (T02) 7.2 Thermal Zoning (T03), Radiant Thermal Comfort (T05) & Thermal Comfort Monitoring (T06) 7.3 Individual Thermal Control (T04) & Humidity Control (T07)

8 Chapter 8: Sound — Acoustic Zoning, Noise Limits, Isolation & Masking

8.1 Sound Mapping (S01) & Maximum Noise Levels (S02) 8.2 Sound Barriers (S03) & Minimum Background Sound (S06) 8.3 Reverberation Time (S04) & Sound Reducing Surfaces (S05)

9 Chapter 9: Materials — Restrictions, Hazard Management, VOCs, Transparency & Cleaning

9.1 Material Restrictions (X01) & Enhanced Material Restrictions (X05) 9.2 Interior Hazardous Materials Management (X02), CCA and Lead Management (X03) & Site Remediation (X04) 9.3 VOC Restrictions (X06), Materials Transparency (X07) & Materials Optimization (X08) 9.4 Waste Management (X09), Pest Management and Pesticide Use (X10) & Cleaning Products and Protocols (X11)

10 Chapter 10: Mind — Mental Health, Nature and Place, Restoration & Substance Use

10.1 Mental Health Promotion (M01), Services (M03) & Education (M04) 10.2 Nature and Place (M02) & Enhanced Access to Nature (M09) 10.3 Restorative Opportunities (M06), Restorative Spaces (M07) & Restorative Programming (M08) 10.4 Stress Management (M05), Tobacco Cessation (M10) & Substance Use Services (M11)

11 Chapter 11: Community — Health Promotion, Integrative Design, Emergency Preparedness & Equity

11.1 Health and Wellness Promotion (C01), Integrative Design (C02) & Enhanced Promotion (C07) 11.2 Emergency Preparedness (C03) & Emergency Resources (C14) 11.3 Occupant Survey (C04), Enhanced Occupant Survey (C05) & Diversity and Inclusion (C12) 11.4 Health Services and Benefits (C06), New Parent Support (C08), New Mother Support (C09), Family Support (C10), Civic Engagement (C11) & Accessibility (C13)

12 Chapter 12: Innovation, WELL Core Applicability & Exam Strategy

12.1 Innovation Features (I01–I05), Alternative Adherence Paths & Equivalencies 12.2 WELL Core Applicability, Multifamily Residential & Sector-Specific Space Types 12.3 WELL AP Exam Mastery: Format, Domain Weights, Embedded Content & Test-Day Strategy

8.1 Sound Mapping (S01) & Maximum Noise Levels (S02)

Key Takeaways Explain This Topic AI

S01 Sound Mapping is the Sound concept's only precondition and requires an annotated floor plan labeling four zone types made available to occupants: Loud, Quiet, Mixed and Circulation zones.

S01 Part 2 accepts either an acoustic design plan developed by the project team or owner with an implementation timeline, or a detailed report from a professional in acoustics.

S02 Maximum Noise Levels defines three categories: Category 1 areas for conferencing, learning or speaking, Category 2 enclosed areas for concentration, and Category 3 open areas for concentration, spaces with PA systems and dining areas.

S02's 3-point tier caps average sound pressure level at 35 dBA in Category 1, 40 dBA in Category 2 and 45 dBA in Category 3, measured over five minutes.

For dwelling units S02 caps average bedroom background noise at 35 dBA measured over at least 12 hours including 10 pm to 7 am.

Last updated: September 2026

8.1 Sound Mapping (S01) & Maximum Noise Levels (S02)

Core Exam Takeaway: Sound has one precondition (S01) and five optimizations (S02–S06) , and carries 8 scored exam questions . S01 Sound Mapping creates the four zone labels — Loud, Quiet, Mixed, Circulation — that S02, S03, S05 and S06 all reference . Learn the zones before the numbers. Then memorize S02's 3-point row: 35 / 40 / 45 dBA for Categories 1 / 2 / 3.

Feature S01: Sound Mapping — Precondition

Intent: incorporate the strategic planning required to prevent issues of acoustic disturbance from various sources of noise.

S01 Part 1 — Label Acoustic Zones

(a) An annotated document is submitted and made available to occupants showing labelled zones throughout the project floor plan or similar schematic:

Zone Definition WELL's examples

Loud zones Areas intended for loud equipment or activities mechanical rooms, kitchens, fitness rooms, social spaces, recreational rooms, music rooms

Quiet zones Areas intended for concentration, wellness, rest, study and/or privacy restorative spaces, lactation rooms, nap rooms

Mixed zones Areas intended for learning, collaboration and/or presentation auditoriums, classrooms, breakout spaces

Circulation zones Occupiable areas not intended for regular occupancy hallways, egress, atria, stairs, lobbies

(b) If Loud zones directly border Quiet zones , the project provides a plan for reprogramming or mitigating sound transmission between them.

S01 Part 2 — Provide Acoustic Design Plan

The project provides one of:

(a) A plan developed by the project team and/or project owner outlining acoustical solutions and a timeline for implementation , focused on managing acoustical comfort, background noise, speech privacy, reverberation time and/or impact noise within the project boundary; or

(b) A detailed report from a professional in acoustics describing existing conditions, recommended solutions and measurement results , focused on background noise, speech privacy, reverberation time and/or impact noise. These measurements are not required to adhere to the Performance Verification Guidebook requirements for on-site testing.

WELL Core guidance for both parts: whole building, based on any knowledge of anticipated uses .

Important

S01's zone labels are load-bearing across the whole concept. S03's wall isolation table is keyed to "Loud zones," "Quiet zones" and "Circulation zones." S06's masking thresholds apply to "open areas with Quiet zones" and "enclosed rooms labeled as Quiet zones." A project that labels its zones carelessly inherits the wrong targets everywhere else — which is exactly why sound mapping is the precondition rather than an optimization.

Tip

Note that Circulation zones are defined as occupiable areas not intended for regular occupancy — a hallway is occupiable but not regularly occupied, which links this definition straight back to the WELL v2 space-occupancy vocabulary. And note Part 1(b)'s remedy language: "reprogramming or mitigating" . Moving the nap room away from the mechanical room is an equally valid answer to a Loud–Quiet adjacency as building a better wall.

Tip

Part 2 offers a team-authored plan or an acoustician's report , and the report route explicitly exempts its measurements from Performance Verification Guidebook protocols . That makes S01 Part 2 achievable with an ordinary consultant survey rather than a formal WELL performance test.

Feature S02: Maximum Noise Levels — Optimization (3 pt / WELL Core 1.5 pt)

Intent: achieve desired ambient noise levels such that HVAC, exterior noise intrusion or other noise sources do not impact occupant health and well-being.

The three categories

S02 defines its own category system, which is not identical to S01's zones:

  • Category 1 — Areas for conferencing, learning or speaking
  • Category 2 — Enclosed areas for concentration
  • Category 3 — Open areas for concentration, spaces with PA systems , and areas for dining
  • S02 Part 1 — Limit Background Noise Levels

For all spaces except dwelling units, commercial kitchen spaces and industrial.

Background noise levels are measured over a period of five minutes and average sound pressure levels do not exceed:

  • Sound pressure level Unit Category 3 Category 2 Category 1 Points (Core)
  • Average SPL ( L eq L_{\text{eq}} L eq ​ ) dBA 45 40 35 3 (1.5)
  • dBC 65 60 55
  • Max SPL ( L Max L_{\text{Max}} L Max ​ ) dBA 55 50 45
  • dBC 75 70 65
  • Average SPL ( L eq L_{\text{eq}} L eq ​ ) dBA 50 45 40 1 (0.5)
  • dBC 70 65 60
  • Max SPL ( L Max L_{\text{Max}} L Max ​ ) dBA 60 55 50
  • dBC 80 75 70

For dwelling units: average background noise levels in bedrooms, measured over a minimum 12-hour period which must include the hours of 10 pm to 7 am, do not exceed 35 dBA ( L eq L_{\text{eq}} L eq ​ ).

WELL Core guidance: non-leased spaces; consider lobbies, hallways and corridors within non-leased spaces as Category 3 ; an additional point for also meeting Category 3 levels in leased spaces. +-----------------------------------------------------------------------------+

  • | S02: HOW THE TABLE IS STRUCTURED (READ THIS FIRST) |
  • | |
  • | THREE AXES, and candidates confuse them constantly: |
  • | |
  • | 1. CATEGORY 1 (conferencing/learning/speaking) is the STRICTEST |
  • | 3 (open concentration / PA / dining) is the LOOSEST |
  • | |
  • | 2. METRIC Average SPL (Leq) is 10 dB tighter than Max SPL (LMax) |
  • | dBC is 20 dB looser than dBA in every single cell |
  • | |
  • | 3. TIER The 3-POINT row is 5 dB tighter than the 1-POINT row |
  • | |
  • | Anchor to memorize: 3-point, Average, dBA = 35 / 40 / 45 |
  • | for Category 1 / 2 / 3 |
  • | Everything else moves from there in clean 5 and 10 dB steps. |
  • +-----------------------------------------------------------------------------+

Important

Why dBA and dBC both appear. The A-weighting curve approximates human sensitivity at moderate levels and heavily discounts low frequencies. The C-weighting curve is nearly flat and therefore captures the low-frequency rumble — fan noise, transformer hum, traffic — that A-weighting hides. A room can pass a dBA limit while being genuinely oppressive from mechanical rumble, which is why S02 imposes both , with dBC set 20 dB above the corresponding dBA value in every cell.

Tip

The dwelling-unit requirement is measured differently in every respect : a 12-hour minimum window rather than five minutes, mandatorily spanning 10 pm to 7 am , in bedrooms , at 35 dBA L eq L_{\text{eq}} L eq ​ — the same number as the strictest Category 1 average, but earned over a night rather than a five-minute sample. Sleep is the use case, so the measurement follows the sleeper.

Warning

S02 excludes commercial kitchen spaces and industrial spaces entirely — those environments are inherently loud, and WELL addresses occupant protection there through other means rather than by setting an unachievable ambient limit.

Reading the concept as a system

The five Sound optimizations divide the problem cleanly, and each is worth locating before studying its numbers:

  • Feature Acoustic problem it solves
  • S02 Maximum Noise Levels Too much ambient noise (HVAC, exterior intrusion)
  • S03 Sound Barriers Sound passing between enclosed spaces — isolation and speech privacy
  • S04 Reverberation Time Sound persisting within a space — intelligibility and vocal effort
  • S05 Sound Reducing Surfaces Build-up of speech and unwanted sound — absorption
  • S06 Minimum Background Sound Too little ambient noise, which makes distant speech intelligible — masking

Note the elegant tension between S02 and S06 : one caps background sound, the other establishes a floor. A room that is too quiet offers no speech privacy at all, because a conversation two desks away becomes perfectly audible. WELL's answer is a band , not a minimum.