Study guide
1.5 Code Structure, Key Definitions, Basic Principles & Referenced Standards
Wisconsin Journeyman Plumber Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Licensing, Exam Rules & Code Administration
1.1 Wisconsin Plumbing Credentials, Scope & Supervision (Ch. 145, SPS 305) 1.2 The Journeyman Exam: Format, Fees, Retakes & Permitted References 1.3 Plan Review, Plan Approval & Product Approvals (SPS 382.20) 1.4 Testing, Inspection, Maintenance & Repairs (SPS 382.21, 382.22) 1.5 Code Structure, Key Definitions, Basic Principles & Referenced Standards
2 Chapter 2: Sanitary Drainage Systems (SPS 382.30)
2.1 Drainage Fixture Units (DFU) & Load Values 2.2 Horizontal Branch Drains, Pitch & Changes in Direction 2.3 Drain Stacks, Branch Intervals & Stack Offsets 2.4 Building Drains, Building Sewers & Private Interceptor Main Sewers
3 Chapter 3: Venting Systems & Cold-Climate Vent Terminals (SPS 382.31)
3.1 Vent Stacks, Relief Vents & Vent Sizing Tables 3.2 Common Vents, Wet Vents & Circuit Vents 3.3 Return Vents, Combination Drain & Vent Systems & Air Admittance Valves 3.4 Vent Terminals, Frost Closure & Prohibited Vent Uses
4 Chapter 4: Traps, Indirect Waste & Wastewater Treatment Devices
4.1 Fixture Traps, Trap Seals & Direct Fixture Connections 4.2 Trap-to-Vent Distances (Table 382.31-1) 4.3 Indirect & Local Waste Piping, Air Gaps & Receptors 4.4 Interceptors, Catch Basins & Chemical Waste Treatment (SPS 382.34)
5 Chapter 5: Water Supply Systems (SPS 382.40)
5.1 Water Supply Fixture Units (WSFU) & Demand 5.2 Sizing Water Distribution Piping: Pressure, Friction & Velocity 5.3 Control Valves, Thermal Expansion, Water Hammer & Pipe Identification 5.4 Water Heaters, Relief Valves, Hot Water Delivery & Temperature Control 5.5 Water Services, Private Water Mains, Disinfection & Storage Tanks
6 Chapter 6: Cross-Connection Control & Backflow Prevention (SPS 382.41)
6.1 Cross-Connection Fundamentals, Hazard Classes & Pressure Conditions 6.2 Backflow Devices & Assemblies: Table 382.41-1, Limits & Installation 6.3 Assembly Registration, DSPS Tags, Annual Testing & Tester Registration
7 Chapter 7: Plumbing Fixtures, Fittings & Appliances (SPS 384.20)
7.1 Fixture Construction, Clearances, Shower Size & Safing 7.2 Water-Conserving Fixtures, Faucets & Fixture Supply Connectors 7.3 Water Heaters, Water Treatment Devices & Other Plumbing Appliances
8 Chapter 8: Piping Materials, Joints & Supports (SPS 384.30, 384.40, 382.60)
8.1 Approved Piping Materials by Service & Lead-Free Rules 8.2 Joints, Connections & Transitions Between Materials (SPS 384.40) 8.3 Hangers, Supports & Protection of Piping (SPS 382.60)
9 Chapter 9: Private Onsite Wastewater Treatment Systems (SPS 383, 385 & Component Manuals)
9.1 POWTS Regulation, Sanitary Permits, Plan Review & Inspection 9.2 Soil & Site Evaluation and In Situ Soil Parameters (SPS 385, SPS 383.44) 9.3 Design Flow, Septic & Holding Tanks and Tank Construction 9.4 Dispersal Components & the DSPS Component Manuals 9.5 POWTS Setbacks, Management, Maintenance Reporting & Abandonment
10 Chapter 10: Cleanouts, Stormwater, Sumps & Multipurpose Piping
10.1 Cleanouts & Manholes (SPS 382.35) 10.2 Stormwater & Clearwater Systems (SPS 382.36) 10.3 Sanitary Sumps, Ejectors & Discharge Points (SPS 382.30 (10), 382.38) 10.4 Multipurpose Piping Systems & NFPA 13D Residential Sprinklers
11 Chapter 11: Special Plumbing Installations & Water Reuse
11.1 Health Care & Related Facilities (SPS 382.50) 11.2 Manufactured Homes, Campgrounds, RV Parks & Dump Stations 11.3 Water Reuse, Plumbing Treatment Standards & Stormwater Infiltration
1.5 Code Structure, Key Definitions, Basic Principles & Referenced Standards
Key Takeaways Explain This Topic AI
The Wisconsin Plumbing Code is chs. SPS 381 to 387, a uniform statewide code: municipalities may not adopt plumbing design or installation ordinances more stringent than SPS 382 unless a rule allows it.
SPS 382 is not retroactive unless a rule says so, and DSPS interpretations override those of lower jurisdictions.
Every dwelling connected to a POWTS or public sewer needs at least one water closet, one wash basin, one kitchen sink and one bathtub or shower (SPS 382.10 (2) (b)).
A water service runs from the main or private supply up to and including the building control valve; a private water main or private interceptor main sewer serves 2 or more buildings.
Alternate standards that are equivalent or more stringent may replace referenced standards with written DSPS approval, decided within 40 business days (SPS 381.20 (2)).
Last updated: October 2026
How the plumbing chapters fit together
- Chapter Content
- SPS 381 Definitions (381.01) and standards incorporated by reference (381.20 and Tables 381.20-1 to -13)
SPS 382 Design, construction, installation, supervision, maintenance and inspection of plumbing: plan review, testing, drain and vent, traps, interceptors, cleanouts, storm, water supply, cross connection, health care, manufactured homes, hangers, treatment standards
- SPS 383 Private onsite wastewater treatment systems
- SPS 384 Plumbing products: approvals, fixtures, materials, joints
- SPS 385 Soil and site evaluations
- SPS 386 Plumbing for boats (sewage holding and disposal)
- SPS 387 Wisconsin Fund POWTS financial assistance
- SPS 302 Fees: plan review, permits, variances, product approvals, cross connection assembly fees
SPS 325 Uniform Dwelling Code plumbing chapter: one- and 2-family dwelling plumbing complies with chs. SPS 381 to 387; sanitation devices such as composting toilets and privies comply with ch. SPS 391 (revised by CR 26-019)
SPS 305 Licenses, certifications and registrations
Wisconsin writes its own plumbing code. It doesn't adopt the IPC or UPC, although it incorporates many ASME, ASSE, ASTM, CSA, NSF and NFPA product and installation standards by reference.
Scope, uniformity and authority (SPS 382.01 to 382.03)
SPS 382 covers sanitary and storm drainage, water supplies, wastewater treatment and discharge for buildings. POWTS are under SPS 383.
Its purpose (SPS 382.015, s. 145.02) is that all plumbing be safe, sanitary and protective of public health and the waters of the state .
The chapter is not retroactive unless a rule says so.
It is uniform . A municipality may not enact an ordinance for plumbing design, construction, installation, supervision, maintenance or inspection more stringent than SPS 382 except where a rule allows. Municipalities may still require local permits and inspections (s. 145.04).
DSPS interpretations and decisions supersede those of lower jurisdictions. Department decisions may be appealed under s. 101.02 (6) (e).
Basic principles (SPS 382.10)
The code's intent statements are used to judge equivalency when a situation isn't specifically covered. Plumbing must:
protect health, safety and the waters of the state
supply enough water at adequate pressure without undue noise, while using the minimum water consistent with performance
- prevent explosion or overheating of water heating vessels
- drain efficiently with adequate cleanouts
- circulate air so trap seals aren't siphoned or forced
- be durable and well made
- prevent backflow contamination of food, water and sterile goods
- space fixtures for use and cleaning
Basic requirements:
Every building for human occupancy has an adequate, safe, potable water supply.
Each dwelling (except camping units) connected to a POWTS or public sewer has at least one water closet, one wash basin, one kitchen sink and one bathtub or shower . A ch. SPS 391 device may substitute for the water closet. Fixture counts for other buildings come from chs. SPS 361 to 366.
Hot or tempered water goes to fixtures that need it.
Buildings without public sewer must treat, recycle, disperse or hold their wastewater.
Fixtures are durable, smooth, nonabsorbent, corrosion-resistant and free of concealed fouling surfaces.
Definitions to know cold (SPS 381.01 and s. 145.01)
Term Meaning
Plumbing (s. 145.01 (10)) Piping, fixtures, appliances and devices of water supply, distribution, drainage, reclaimed water and stormwater use systems, including water heaters, treatment devices and their installation; sewer and water service piping to the main; POWTS. It excludes gutters and downspouts down to their discharge into a plumbing system or subsoil or foundation drain, process water reuse not connected to fixtures, and culverts
Branch interval A vertical distance of 8 feet or more between horizontal branch connections to a stack
Building drain Horizontal piping within or under the fully enclosed building, below the lowest fixture, draining by gravity to the sewer
Building sewer The drain system outside the fully enclosed building, carrying discharge to a public sewer, private interceptor main sewer, POWTS or other point
- Developed length Length measured along the centerline of pipe and fittings
- Indirect waste piping Drain piping discharging through an air break or air gap into a receptor
Local waste piping Piping that receives indirect waste and discharges through an air break or air gap into a receptor
Private interceptor main sewer / private water main Serves 2 or more buildings and is not part of the municipal system
Water service From the water main or private supply up to and including the building control valve
Vent stack / stack vent A vent stack provides air for a drain stack of 5 or more branch intervals; a stack vent extends from the highest horizontal drain connected to a stack
Wet vent The portion of a vent pipe that receives discharge from other fixtures
Clear water / storm water Clear water is wastewater other than storm water with no harmful impurities (cooling water, condensate); storm water is wastewater from precipitation
Lead-free No more than 0.2% lead in solder and flux and a 0.25% weighted average on wetted surfaces
Public building / place of employment As defined in s. 101.01 (12) and (11), Stats.; a public building is used by the public or by 3 or more tenants
Referenced and alternate standards (SPS 381.20)
Standards listed in Tables 381.20-1 to 381.20-13 apply to the extent the code references them, including standards they in turn reference, except as the code modifies them. Examples are NFPA 13D-2019, NFPA 24-2019, ASSE series, ASME A112 series, ASTM pipe standards and ANSI/ISEA Z358.1.
Alternate standards that are equivalent or more stringent may be used instead with DSPS approval:
A written request and fee are required, decided within 40 business days .
The approval is based on an analysis by an independent third party or the standard's publisher.
DSPS may attach conditions or an expiration date.
The IAPMO Peak Water Demand Calculator is a code-noted example for water pipe sizing (SPS 382.40 (7)).
Exam tip
Many items test which chapter governs a question. Septic tank setbacks are in SPS 383, not 382. Pipe material lists are in SPS 384, not 382. A journeyman's supervision is in SPS 305. Soil tester duties are in SPS 385. Knowing the map lets you open the binder to the right tab in seconds.