Study guide

7.1 Fixture Construction, Clearances, Shower Size & Safing

Wisconsin Journeyman Plumber Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Licensing, Exam Rules & Code Administration

1.1 Wisconsin Plumbing Credentials, Scope & Supervision (Ch. 145, SPS 305) 1.2 The Journeyman Exam: Format, Fees, Retakes & Permitted References 1.3 Plan Review, Plan Approval & Product Approvals (SPS 382.20) 1.4 Testing, Inspection, Maintenance & Repairs (SPS 382.21, 382.22) 1.5 Code Structure, Key Definitions, Basic Principles & Referenced Standards

2 Chapter 2: Sanitary Drainage Systems (SPS 382.30)

2.1 Drainage Fixture Units (DFU) & Load Values 2.2 Horizontal Branch Drains, Pitch & Changes in Direction 2.3 Drain Stacks, Branch Intervals & Stack Offsets 2.4 Building Drains, Building Sewers & Private Interceptor Main Sewers

3 Chapter 3: Venting Systems & Cold-Climate Vent Terminals (SPS 382.31)

3.1 Vent Stacks, Relief Vents & Vent Sizing Tables 3.2 Common Vents, Wet Vents & Circuit Vents 3.3 Return Vents, Combination Drain & Vent Systems & Air Admittance Valves 3.4 Vent Terminals, Frost Closure & Prohibited Vent Uses

4 Chapter 4: Traps, Indirect Waste & Wastewater Treatment Devices

4.1 Fixture Traps, Trap Seals & Direct Fixture Connections 4.2 Trap-to-Vent Distances (Table 382.31-1) 4.3 Indirect & Local Waste Piping, Air Gaps & Receptors 4.4 Interceptors, Catch Basins & Chemical Waste Treatment (SPS 382.34)

5 Chapter 5: Water Supply Systems (SPS 382.40)

5.1 Water Supply Fixture Units (WSFU) & Demand 5.2 Sizing Water Distribution Piping: Pressure, Friction & Velocity 5.3 Control Valves, Thermal Expansion, Water Hammer & Pipe Identification 5.4 Water Heaters, Relief Valves, Hot Water Delivery & Temperature Control 5.5 Water Services, Private Water Mains, Disinfection & Storage Tanks

6 Chapter 6: Cross-Connection Control & Backflow Prevention (SPS 382.41)

6.1 Cross-Connection Fundamentals, Hazard Classes & Pressure Conditions 6.2 Backflow Devices & Assemblies: Table 382.41-1, Limits & Installation 6.3 Assembly Registration, DSPS Tags, Annual Testing & Tester Registration

7 Chapter 7: Plumbing Fixtures, Fittings & Appliances (SPS 384.20)

7.1 Fixture Construction, Clearances, Shower Size & Safing 7.2 Water-Conserving Fixtures, Faucets & Fixture Supply Connectors 7.3 Water Heaters, Water Treatment Devices & Other Plumbing Appliances

8 Chapter 8: Piping Materials, Joints & Supports (SPS 384.30, 384.40, 382.60)

8.1 Approved Piping Materials by Service & Lead-Free Rules 8.2 Joints, Connections & Transitions Between Materials (SPS 384.40) 8.3 Hangers, Supports & Protection of Piping (SPS 382.60)

9 Chapter 9: Private Onsite Wastewater Treatment Systems (SPS 383, 385 & Component Manuals)

9.1 POWTS Regulation, Sanitary Permits, Plan Review & Inspection 9.2 Soil & Site Evaluation and In Situ Soil Parameters (SPS 385, SPS 383.44) 9.3 Design Flow, Septic & Holding Tanks and Tank Construction 9.4 Dispersal Components & the DSPS Component Manuals 9.5 POWTS Setbacks, Management, Maintenance Reporting & Abandonment

10 Chapter 10: Cleanouts, Stormwater, Sumps & Multipurpose Piping

10.1 Cleanouts & Manholes (SPS 382.35) 10.2 Stormwater & Clearwater Systems (SPS 382.36) 10.3 Sanitary Sumps, Ejectors & Discharge Points (SPS 382.30 (10), 382.38) 10.4 Multipurpose Piping Systems & NFPA 13D Residential Sprinklers

11 Chapter 11: Special Plumbing Installations & Water Reuse

11.1 Health Care & Related Facilities (SPS 382.50) 11.2 Manufactured Homes, Campgrounds, RV Parks & Dump Stations 11.3 Water Reuse, Plumbing Treatment Standards & Stormwater Infiltration

7.1 Fixture Construction, Clearances, Shower Size & Safing

Key Takeaways Explain This Topic AI

A water closet, urinal or bidet centerline must be at least 15 inches from any side wall, partition, vanity or obstruction; water closets and urinals are at least 30 inches center to center.

A water closet needs at least 24 inches of clearance in front to any wall, fixture or door (SPS 384.20 (5) (o) 4.).

Shower compartments need at least 900 square inches of finished interior and must enclose a 30-inch circle, or a 25-inch circle with at least 1,300 square inches.

Site-built shower floors need safing up the sides at least 6 inches above the curb, and to 6 feet high at the corners; floor drains need safing extending 12 inches.

Water closets required in public buildings must be elongated with open-front seats without covers (or continuous-sleeve closed seats).

Last updated: October 2026

Design and material rules (SPS 384.20 (1), (2) and (4))

All fixtures, appliances and equipment must be durable, free from defects and concealed fouling surfaces , and easy to clean. They must also prevent nonpotable liquids, solids or gases from entering the potable supply. Fixture surfaces must be smooth and impervious to water. End-point drinking water fittings must meet NSF/ANSI/CAN 61, section 9 .

Installation requirements (SPS 384.20 (4) (b)):

  • Topic Requirement
  • Access Fixtures installed for easy cleaning of the fixture and the area around it

Wall-mounted fixtures Supported by a hanger fastened to structure so no load goes onto the drain connection; floor-affixed supports meet ASME A112.6.1M, framing-affixed carriers meet ASME A112.6.2

Outlet joint Fixture outlet connection to the drain must be air- and watertight

Overflows Designed so water can't rise in the overflow with the stopper closed and doesn't stand in it when the fixture is empty; overflows discharge on the inlet side of the trap

Flush tank overflows Discharge to the fixture served; sized to prevent flooding at the maximum supply rate

Strainers All fixtures except water closets, clinic sinks, flushing-rim service sinks, urinals, standpipes and waste sinks need strainers, crossbars or pop-up stoppers

Flushometer valves Equipped with ASSE 1001 vacuum breakers; complete the cycle automatically; have a flow regulating means; not used where pressure is inadequate

Clearances

  • Fixture Side clearance (centerline to wall, partition, vanity or obstruction) Center to center Front
  • Water closet 15 inches 30 inches between water closets 24 inches to any wall, fixture or door
  • Urinal 15 inches 30 inches between urinals -
  • Bidet 15 inches 30 inches from a water closet -

Worked example. A two-closet restroom is being laid out in a 60-inch-wide alcove. Each closet needs 15 inches to a side wall and 30 inches to the next closet: 15 + 30 + 15 = 60 inches , so it fits exactly. Then check the front clearance: the door swing must leave at least 24 inches in front of each bowl.

Shower compartments (SPS 384.20 (5) (L))

  • Requirement Value
  • Minimum finished interior area 900 square inches
  • Minimum inscribed circle 30 inches
  • Alternative A 25-inch circle if the area is at least 1,300 square inches
  • Measured In a horizontal plane 24 inches above the top of the threshold, not past the threshold centerline

Maintained up to 70 inches above the waste outlet, with only valves, heads, soap dishes, retractable seats and grab bars protruding

Waste outlet At least 2 inches with a removable strainer (except tub-shower units)

Multiple heads or spaces on one outlet 2-inch outlet located, and floor pitched, so water from one shower doesn't cross another's floor area

A 30 x 30 inch shower has exactly 900 square inches and holds a 30-inch circle, so it complies. A 32 x 28 inch shower has 896 square inches and won't hold a 30-inch circle, so it fails.

Safing (SPS 384.20 (4) (b) 9.)

Floors of site-constructed shower stalls and shower rooms are protected by safing under the entire finished floor, turned up the sides at least 6 inches above the curb or maximum water level.

Corners are safed to 6 feet high and at least 3 inches in each direction from the corner.

Floor drains and similar fixtures need safing extending at least 12 inches from the fixture.

Safing must meet SPS 384.30 (6) and be properly drained. Installations directly over unexcavated ground are exempt. Elevator threshold drains are also exempt.

Fixture-by-fixture requirements (SPS 384.20 (5))

Fixture Key rules

Bathtubs Waste and overflow at least 1-1/2 inches with a closing device; whirlpool piping and pump waterways drain by gravity to the tub trap

Drinking fountains Not in toilet rooms ; adjustable valve with loose key or self-closing valve; waste outlet at least 1-1/4 inches

  • Floor and trench drains Removable strainers; outlet at least 2 inches ; ASME A112.6.3
  • Laundry trays Each compartment outlet at least 1-1/2 inches
  • Lavatories Waste outlet at least 1-1/4 inches
  • Sinks Waste outlet at least 1-1/2 inches

Urinals Stall urinals set into a pitched floor; automatic siphon flush tanks prohibited ; pressurized flushing devices ASSE 1037

Water closets One flushing device each; anti-siphon fill valve (ASSE 1002) with critical level at least 1 inch above the overflow pipe opening; pressurized flushing devices ASSE 1037

Water closets in public buildings and places of employment must be elongated with either a hinged open-front seat without cover , or a hinged closed-front seat without cover in a continuous plastic sleeve. Day care centers, individual living or sleeping units may use round bowls with closed-front seats, with or without covers. Prisons may use round bowls with or without seats.

Prohibited water closets : pan, plunger, offset washout, washout, long hopper, frostproof , and any type with invisible seals, unventilated spaces or walls not fully cleansed at each flush.

Where toilet-room counts and accessibility live

The plumbing code doesn't set the number of fixtures required or accessibility dimensions. A note to SPS 384.20 (4) points to the commercial building code (chs. SPS 361 to 366) and the pool code (ch. SPS 390) for fixture counts, compartments, toilet room finishes and facilities for people with disabilities. Those chapters are not on the journeyman exam's permitted reference list.

Loading diagram... Laying out a restroom fixture