Study guide

8.1 Approved Piping Materials by Service & Lead-Free Rules

Wisconsin Journeyman Plumber Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Licensing, Exam Rules & Code Administration

1.1 Wisconsin Plumbing Credentials, Scope & Supervision (Ch. 145, SPS 305) 1.2 The Journeyman Exam: Format, Fees, Retakes & Permitted References 1.3 Plan Review, Plan Approval & Product Approvals (SPS 382.20) 1.4 Testing, Inspection, Maintenance & Repairs (SPS 382.21, 382.22) 1.5 Code Structure, Key Definitions, Basic Principles & Referenced Standards

2 Chapter 2: Sanitary Drainage Systems (SPS 382.30)

2.1 Drainage Fixture Units (DFU) & Load Values 2.2 Horizontal Branch Drains, Pitch & Changes in Direction 2.3 Drain Stacks, Branch Intervals & Stack Offsets 2.4 Building Drains, Building Sewers & Private Interceptor Main Sewers

3 Chapter 3: Venting Systems & Cold-Climate Vent Terminals (SPS 382.31)

3.1 Vent Stacks, Relief Vents & Vent Sizing Tables 3.2 Common Vents, Wet Vents & Circuit Vents 3.3 Return Vents, Combination Drain & Vent Systems & Air Admittance Valves 3.4 Vent Terminals, Frost Closure & Prohibited Vent Uses

4 Chapter 4: Traps, Indirect Waste & Wastewater Treatment Devices

4.1 Fixture Traps, Trap Seals & Direct Fixture Connections 4.2 Trap-to-Vent Distances (Table 382.31-1) 4.3 Indirect & Local Waste Piping, Air Gaps & Receptors 4.4 Interceptors, Catch Basins & Chemical Waste Treatment (SPS 382.34)

5 Chapter 5: Water Supply Systems (SPS 382.40)

5.1 Water Supply Fixture Units (WSFU) & Demand 5.2 Sizing Water Distribution Piping: Pressure, Friction & Velocity 5.3 Control Valves, Thermal Expansion, Water Hammer & Pipe Identification 5.4 Water Heaters, Relief Valves, Hot Water Delivery & Temperature Control 5.5 Water Services, Private Water Mains, Disinfection & Storage Tanks

6 Chapter 6: Cross-Connection Control & Backflow Prevention (SPS 382.41)

6.1 Cross-Connection Fundamentals, Hazard Classes & Pressure Conditions 6.2 Backflow Devices & Assemblies: Table 382.41-1, Limits & Installation 6.3 Assembly Registration, DSPS Tags, Annual Testing & Tester Registration

7 Chapter 7: Plumbing Fixtures, Fittings & Appliances (SPS 384.20)

7.1 Fixture Construction, Clearances, Shower Size & Safing 7.2 Water-Conserving Fixtures, Faucets & Fixture Supply Connectors 7.3 Water Heaters, Water Treatment Devices & Other Plumbing Appliances

8 Chapter 8: Piping Materials, Joints & Supports (SPS 384.30, 384.40, 382.60)

8.1 Approved Piping Materials by Service & Lead-Free Rules 8.2 Joints, Connections & Transitions Between Materials (SPS 384.40) 8.3 Hangers, Supports & Protection of Piping (SPS 382.60)

9 Chapter 9: Private Onsite Wastewater Treatment Systems (SPS 383, 385 & Component Manuals)

9.1 POWTS Regulation, Sanitary Permits, Plan Review & Inspection 9.2 Soil & Site Evaluation and In Situ Soil Parameters (SPS 385, SPS 383.44) 9.3 Design Flow, Septic & Holding Tanks and Tank Construction 9.4 Dispersal Components & the DSPS Component Manuals 9.5 POWTS Setbacks, Management, Maintenance Reporting & Abandonment

10 Chapter 10: Cleanouts, Stormwater, Sumps & Multipurpose Piping

10.1 Cleanouts & Manholes (SPS 382.35) 10.2 Stormwater & Clearwater Systems (SPS 382.36) 10.3 Sanitary Sumps, Ejectors & Discharge Points (SPS 382.30 (10), 382.38) 10.4 Multipurpose Piping Systems & NFPA 13D Residential Sprinklers

11 Chapter 11: Special Plumbing Installations & Water Reuse

11.1 Health Care & Related Facilities (SPS 382.50) 11.2 Manufactured Homes, Campgrounds, RV Parks & Dump Stations 11.3 Water Reuse, Plumbing Treatment Standards & Stormwater Infiltration

8.1 Approved Piping Materials by Service & Lead-Free Rules

Key Takeaways Explain This Topic AI

Lead-free means no more than 0.2 percent lead in solder and flux and no more than a 0.25 percent weighted average on wetted surfaces (SPS 381.01 (141)); leaded joints are allowed only to repair cast iron pipe.

Water service and private main pipe must be rated at least 150 psig at 73.4 degrees F; water distribution pipe at least 100 psig at 180 degrees F.

Type M copper tubing may not be installed underground, and copper may not be used where the water's pH is 6.5 or less.

Plastic or copper pipe within 1 inch of a framing edge needs a steel plate of at least No. 18 gauge extending 1-1/2 inches beyond the pipe.

Kinked pipe, pipe with gouges or deep scratches, bent rigid pipe and piping previously used for anything but potable water may not be installed in water supply systems.

Last updated: October 2026

General rules (SPS 384.30 (1))

Design must consider sizing, working pressure, temperature, material compatibility with the water or wastewater, and the installation environment. CR 26-019, effective September 1, 2026, added these handling rules:

  • Rule Requirement
  • Flexible or annealed pipe Bend or offset only per the material standard or manufacturer
  • Rigid pipe Bending or offsetting is prohibited
  • Damaged pipe No gouges, cuts or deep scratches; kinked pipe may not be installed

Framing protection Plastic or copper pipe through framing within 1 inch of the edge gets a steel plate of at least No. 18 gauge extending 1-1/2 inches beyond the pipe

Low-flow treatment piping Piping downstream of treatment devices serving outlets under 1 gpm is sleeved through walls, floors and structural members

Lead-free (SPS 384.30 (1m) and SPS 381.01 (141))

Lead-free means:

No more than 0.2 percent lead in solder and flux.

No more than a weighted average of 0.25 percent lead on the wetted surfaces of pipes, fittings and fixtures.

Weighted average = the sum, over every wetted component, of (percent lead of the component x its share of total wetted area). Use the maximum value of any range. Count coatings and liners, but exclude filter media.

Non-lead-free material may not be used to install or repair any public water system or any plumbing that provides water for human consumption . The only exception is leaded joints needed to repair cast iron pipe . Drinking water coolers have extra limits: no more than 0.2 percent lead in solder, flux or tank surfaces, and no more than 8 percent in any single wetted part.

Drain, waste and vent materials (SPS 384.30 (2) and (3))

Service Table Notes

Aboveground drain and vent 384.30-1 ABS, brass, cast iron, CPVC, copper, ductile iron, galvanized steel, PE, PP, PVC (Schedule 40 for F891 cellular core), PVDF, 304 and 316L stainless; synthetic rubber hose only for dishwasher indirect or local waste

Underground drain and vent 384.30-2 ABS, brass, cast iron, CPVC, copper ( no Type M ), ductile iron, PVC (D3034 limited to SDR 26 or less; F891 to Schedule 40), 316L stainless; no galvanized steel underground

Sanitary building sewer 384.30-3 Adds concrete, PE, PP, vitrified clay (extra strength) and PVC sewer profiles; thermoplastic sewer pipe installed per ASTM D2321

POWTS non-perforated, non-pressurized 384.30-3 Same as building sewer

POWTS perforated gravity distribution 384.30-4 PE and PVC must have exactly 2 rows of holes, 120 degrees plus or minus 5 apart, at the 4 and 8 o'clock positions

Pressurized drain, POWTS pressure laterals, service suction lines 384.30-5 Rated for working pressure and temperature

Storm building sewer 384.30-6 Includes elliptical concrete; thermoplastic per ASTM D2774

Storm conductors inside buildings 384.30-1 Black steel (ASTM A53) also allowed but may not be embedded in concrete or masonry

Chemical drain and vent - Corrosion-resistant material the manufacturer verifies for the chemicals

Catch basins, interceptors and sumps must be watertight and built of precast or monolithic reinforced concrete, cast iron, coated 12-gauge steel , vitrified clay, fiberglass, plastic or other approved material. Fiberglass manholes are allowed in traffic areas only if the top section is not fiberglass. Roof drains need removable strainers and an outlet of at least 2 inches .

Water supply materials (SPS 384.30 (4))

  • Use Minimum rating Table
  • Water services and private water mains 150 psig at 73.4 degrees F 384.30-7
  • Water distribution 100 psig at 180 degrees F 384.30-8
  • Underground cold water distribution 150 psig at 73.4 degrees F 384.30-7 or 384.30-8

Cold distribution downstream of under-1-gpm treatment devices 100 psig at 73.4 degrees F 384.30-8 or 384.30-11, marked every 4 ft

All water supply pipe and fittings must be lead-free (no more than 0.25 percent weighted average). Plastic water pipe must be certified for potable water by an acceptable listing agency. Key footnotes:

Type M copper may not be installed underground.

Copper may not be used where the water's pH is 6.5 or less .

304 stainless may not be installed underground.

Plastic services are installed per ASTM D2774 .

Combination fire and domestic services and mains must also meet NFPA 24 .

A local government may restrict water service materials in rights-of-way by ordinance, but only after department review.

Water piping is prohibited in contaminated soil or groundwater (solvents, fuels, organics) unless the contamination is eliminated, the pipe and joints are proven resistant, or the route avoids it. A chemical analysis may be required where contamination is suspected. Used piping that has carried anything other than potable water may never be reused for water supply.

Fittings, valves and special materials (SPS 384.30 (5) and (6))

Fittings meet the pipe standard or Table 384.30-9. Threaded drain fittings must be the recessed drainage type. Steel and malleable iron fittings in water systems must be galvanized.

Water service valves are rated at least 125 psig at 73.4 degrees F ; distribution valves at least 100 psig at 180 degrees F .

A valve serving 2 or more fixtures may not be a globe valve , and its open passage must be no more than one nominal size smaller than the pipe.

Special devices: water hammer arrestors ASSE 1010 ; pressure-reducing valves ASSE 1003 ; backwater valves ASME A112.14.1 or CSA B1800 ; stack AAVs ASSE 1050 and branch AAVs ASSE 1051 ; trap primers ASSE 1018 (water-fed) and 1044 (drainage and electric); freeze-resistant wall hydrants ASSE 1019 ; sanitary yard hydrants ASSE 1057 ; push-fit fittings ASSE 1061 (only 2 inches and under, and not in T&P drain lines unless rated for 210 degrees F and 150 psig).

Sheet lead flashing : 3 lb/sq ft site-fabricated, 2-1/2 lb/sq ft prefabricated. Sheet copper : 8 oz/sq ft for vent flashing and 10 oz/sq ft for flush tank linings.

Copper or tubular brass traps are at least 20 gauge . Brass cleanout plugs go only in metallic piping.

Safing must stay waterproof under 2 feet of hydrostatic head (ASTM C1306 or D4068).

POWTS aggregate is washed stone 1/2 to 2-1/2 inches with a Mohs hardness of at least 3.

Loading diagram... Choosing a pipe material