Study guide

8.2 Joints, Connections & Transitions Between Materials (SPS 384.40)

Wisconsin Journeyman Plumber Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Licensing, Exam Rules & Code Administration

1.1 Wisconsin Plumbing Credentials, Scope & Supervision (Ch. 145, SPS 305) 1.2 The Journeyman Exam: Format, Fees, Retakes & Permitted References 1.3 Plan Review, Plan Approval & Product Approvals (SPS 382.20) 1.4 Testing, Inspection, Maintenance & Repairs (SPS 382.21, 382.22) 1.5 Code Structure, Key Definitions, Basic Principles & Referenced Standards

2 Chapter 2: Sanitary Drainage Systems (SPS 382.30)

2.1 Drainage Fixture Units (DFU) & Load Values 2.2 Horizontal Branch Drains, Pitch & Changes in Direction 2.3 Drain Stacks, Branch Intervals & Stack Offsets 2.4 Building Drains, Building Sewers & Private Interceptor Main Sewers

3 Chapter 3: Venting Systems & Cold-Climate Vent Terminals (SPS 382.31)

3.1 Vent Stacks, Relief Vents & Vent Sizing Tables 3.2 Common Vents, Wet Vents & Circuit Vents 3.3 Return Vents, Combination Drain & Vent Systems & Air Admittance Valves 3.4 Vent Terminals, Frost Closure & Prohibited Vent Uses

4 Chapter 4: Traps, Indirect Waste & Wastewater Treatment Devices

4.1 Fixture Traps, Trap Seals & Direct Fixture Connections 4.2 Trap-to-Vent Distances (Table 382.31-1) 4.3 Indirect & Local Waste Piping, Air Gaps & Receptors 4.4 Interceptors, Catch Basins & Chemical Waste Treatment (SPS 382.34)

5 Chapter 5: Water Supply Systems (SPS 382.40)

5.1 Water Supply Fixture Units (WSFU) & Demand 5.2 Sizing Water Distribution Piping: Pressure, Friction & Velocity 5.3 Control Valves, Thermal Expansion, Water Hammer & Pipe Identification 5.4 Water Heaters, Relief Valves, Hot Water Delivery & Temperature Control 5.5 Water Services, Private Water Mains, Disinfection & Storage Tanks

6 Chapter 6: Cross-Connection Control & Backflow Prevention (SPS 382.41)

6.1 Cross-Connection Fundamentals, Hazard Classes & Pressure Conditions 6.2 Backflow Devices & Assemblies: Table 382.41-1, Limits & Installation 6.3 Assembly Registration, DSPS Tags, Annual Testing & Tester Registration

7 Chapter 7: Plumbing Fixtures, Fittings & Appliances (SPS 384.20)

7.1 Fixture Construction, Clearances, Shower Size & Safing 7.2 Water-Conserving Fixtures, Faucets & Fixture Supply Connectors 7.3 Water Heaters, Water Treatment Devices & Other Plumbing Appliances

8 Chapter 8: Piping Materials, Joints & Supports (SPS 384.30, 384.40, 382.60)

8.1 Approved Piping Materials by Service & Lead-Free Rules 8.2 Joints, Connections & Transitions Between Materials (SPS 384.40) 8.3 Hangers, Supports & Protection of Piping (SPS 382.60)

9 Chapter 9: Private Onsite Wastewater Treatment Systems (SPS 383, 385 & Component Manuals)

9.1 POWTS Regulation, Sanitary Permits, Plan Review & Inspection 9.2 Soil & Site Evaluation and In Situ Soil Parameters (SPS 385, SPS 383.44) 9.3 Design Flow, Septic & Holding Tanks and Tank Construction 9.4 Dispersal Components & the DSPS Component Manuals 9.5 POWTS Setbacks, Management, Maintenance Reporting & Abandonment

10 Chapter 10: Cleanouts, Stormwater, Sumps & Multipurpose Piping

10.1 Cleanouts & Manholes (SPS 382.35) 10.2 Stormwater & Clearwater Systems (SPS 382.36) 10.3 Sanitary Sumps, Ejectors & Discharge Points (SPS 382.30 (10), 382.38) 10.4 Multipurpose Piping Systems & NFPA 13D Residential Sprinklers

11 Chapter 11: Special Plumbing Installations & Water Reuse

11.1 Health Care & Related Facilities (SPS 382.50) 11.2 Manufactured Homes, Campgrounds, RV Parks & Dump Stations 11.3 Water Reuse, Plumbing Treatment Standards & Stormwater Infiltration

8.2 Joints, Connections & Transitions Between Materials (SPS 384.40)

Key Takeaways Explain This Topic AI

Cement or concrete joints, mastic or hot-poured bituminous joints, rolling O-rings between different pipe sizes, solvent joints between different plastics (except ABS to PVC non-pressure) and roll-grooved galvanized pipe are prohibited.

Caulked lead joints are packed with oakum or hemp and poured in one operation at least 1 inch deep, ending no more than 1/8 inch below the hub rim; drain caulked joints are allowed only in vertical positions.

PVC solvent joints use ASTM F656 primer and ASTM D2564 cement; water supply primer and cement must carry NSF 14 certification.

Threaded plastic joints are allowed only on Schedule 80 or heavier pipe, with joint compound or tape on male threads only.

Dissimilar metals must be protected against galvanic current with dielectric unions (ASSE 1079), flanges (ASME B16.24) or listed transition fittings.

Last updated: October 2026

General rules (SPS 384.40 (1))

Every joint must be watertight and gastight to the greater of the test or design requirement. Pipe ends are prepared per the pipe standard or manufacturer. Unless another rule allows them, these joints are prohibited :

  • Cement or concrete joints
  • Mastic or hot-poured bituminous joints
  • Elastomeric rolling O-rings between pipes of different diameters
  • Solvent-cement joints between different types of plastic , except ABS to PVC in non-pressurized systems
  • Roll-grooving of galvanized steel pipe
  • Joining methods by material

Material Permitted joints Key details

ABS Mechanical (push-on DWV per ASTM D3212); solvent (ASTM D2235); threaded Threads only on Schedule 80 or heavier, cut with plastic-pipe dies; lubricant on male threads only

Black steel Threaded (ASME B1.20.1); mechanical; caulked (DWV only); welded Compound or tape on male threads only

Brass Brazed (AWS A5.8); mechanical; soldered (ASTM B32); threaded Surfaces cleaned bright by non-chemical means; lead-free for water

Cast iron Caulked; mechanical; threaded DWV push-on gaskets ASTM C564; no-hub sleeves ASTM C564, CISPI 310 or FM 1680; water push-on AWWA C111, no lead-tipped gaskets

CPVC Mechanical (ASTM D3139 for water); solvent (ASTM D2846, F493 or F3328); threaded on Schedule 80 F493 cement; NSF 14 primer and cement for water

Copper Brazed; flared on annealed tubing only, with a flaring tool ; mechanical; soldered per ASTM B828 with NSF-approved flux; threaded Lead-free materials for water

  • Ductile iron Mechanical (AWWA C111, no lead-tipped gaskets); threaded -
  • Galvanized steel Threaded; mechanical; caulked (DWV only) No roll grooving
  • PE Heat fusion (ASTM F2620); mechanical (ASTM D3139 for water) Joint left undisturbed until cool
  • Other polyolefins Heat fusion per ASTM D2657 -
  • PEX Per manufacturer's instructions Fittings from Table 384.30-9

PVC Mechanical (DWV ASTM D3212; water ASTM D3139); solvent (ASTM D2855 or F3328); threaded on Schedule 80 F656 primer and D2564 cement ; NSF 14 for water

  • Stainless steel Mechanical; threaded; welded -
  • Lead Burned or wiped Wiped joint at least 3/4 inch exposed each side and 3/8 inch thick

Solvent cements are handled per ASTM F402 . Joint surfaces must be clean and dry, and the joint must be made while the cement is wet.

Caulked lead joints

For hub-and-spigot DWV pipe, the joint is:

Packed firmly with oakum or hemp .

Poured with molten lead in one operation , at least 1 inch deep , ending no more than 1/8 inch below the rim .

Caulked tight.

Not painted or coated until tested and approved.

Caulked joints in drain piping may be used only in a vertical position; in vent piping, vertical or horizontal. For cast iron water pipe, the bell is packed with treated paper rope and poured 2-1/2 inches deep.

Transitions between materials (SPS 384.40 (16))

Different materials are connected with mechanical compression joints installed per the manufacturer, or by the specific methods below. Dissimilar metals must be protected from galvanic current and stray currents:

  • Dielectric nipples: ASME B1.20.1 or ASTM A53
  • Dielectric unions: ASSE 1079
  • Dielectric flanges: ASME B16.24
  • Dielectric transition fittings: NSF 61 and NSF 372
  • Connection Method
  • Copper to cast iron Caulked joint or threaded fitting
  • Cast iron to steel or brass Caulked or threaded joint
  • Plastic to cast iron Caulked or threaded joint

Plastic to other plastic, or plastic to other non-cast-iron material Threaded joint per the PVC threaded-joint rule (Schedule 80), unless ABS to PVC below

Lead to other materials Adapter fitting, with the lead caulked or burned to it

ABS to PVC, non-pressurized Solvent weld: ASTM F656 primer on the PVC surfaces, ASTM D3138 transition cement, handled per F402

Fixtures and concrete structures (SPS 384.40 (17) and (18))

Flanged fixtures with integral traps , such as water closets, are mechanically fastened to a compatible fitting and sealed with a watertight gasket or setting compound.

Pipe-to-concrete connections use resilient connectors:

  • ASTM C923 for manholes
  • ASTM F2510 for corrugated PE or PP pipe at manholes
  • ASTM C1644 for on-site wastewater tanks
  • ASTM C1478 for storm structures
  • ASTM C564 gaskets for cast iron
  • Worked examples

A plumber joins a new PVC drain to an existing ABS building drain in a house, a non-pressurized system. The solvent weld is allowed with PVC primer and an ASTM D3138 transition cement. Using regular PVC cement without the D3138 transition product would not comply.

A copper water line meets a galvanized steel line. A dielectric union meeting ASSE 1079 (or another listed dielectric fitting) is needed to stop galvanic corrosion.

A 3-inch no-hub cast iron horizontal drain joint has no alignment shield. It must be supported within 24 inches on each side (SPS 382.60 (2) (b), section 8.3).

An installer roll-grooves galvanized pipe for a quick coupling. This is prohibited: use threaded or other approved mechanical joints.

Loading diagram... Choosing a joint