9.4 Dispersal Components & the DSPS Component Manuals

Wisconsin Journeyman Plumber Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Licensing, Exam Rules & Code Administration

1.1 Wisconsin Plumbing Credentials, Scope & Supervision (Ch. 145, SPS 305) 1.2 The Journeyman Exam: Format, Fees, Retakes & Permitted References 1.3 Plan Review, Plan Approval & Product Approvals (SPS 382.20) 1.4 Testing, Inspection, Maintenance & Repairs (SPS 382.21, 382.22) 1.5 Code Structure, Key Definitions, Basic Principles & Referenced Standards

2 Chapter 2: Sanitary Drainage Systems (SPS 382.30)

2.1 Drainage Fixture Units (DFU) & Load Values 2.2 Horizontal Branch Drains, Pitch & Changes in Direction 2.3 Drain Stacks, Branch Intervals & Stack Offsets 2.4 Building Drains, Building Sewers & Private Interceptor Main Sewers

3 Chapter 3: Venting Systems & Cold-Climate Vent Terminals (SPS 382.31)

3.1 Vent Stacks, Relief Vents & Vent Sizing Tables 3.2 Common Vents, Wet Vents & Circuit Vents 3.3 Return Vents, Combination Drain & Vent Systems & Air Admittance Valves 3.4 Vent Terminals, Frost Closure & Prohibited Vent Uses

4 Chapter 4: Traps, Indirect Waste & Wastewater Treatment Devices

4.1 Fixture Traps, Trap Seals & Direct Fixture Connections 4.2 Trap-to-Vent Distances (Table 382.31-1) 4.3 Indirect & Local Waste Piping, Air Gaps & Receptors 4.4 Interceptors, Catch Basins & Chemical Waste Treatment (SPS 382.34)

5 Chapter 5: Water Supply Systems (SPS 382.40)

5.1 Water Supply Fixture Units (WSFU) & Demand 5.2 Sizing Water Distribution Piping: Pressure, Friction & Velocity 5.3 Control Valves, Thermal Expansion, Water Hammer & Pipe Identification 5.4 Water Heaters, Relief Valves, Hot Water Delivery & Temperature Control 5.5 Water Services, Private Water Mains, Disinfection & Storage Tanks

6 Chapter 6: Cross-Connection Control & Backflow Prevention (SPS 382.41)

6.1 Cross-Connection Fundamentals, Hazard Classes & Pressure Conditions 6.2 Backflow Devices & Assemblies: Table 382.41-1, Limits & Installation 6.3 Assembly Registration, DSPS Tags, Annual Testing & Tester Registration

7 Chapter 7: Plumbing Fixtures, Fittings & Appliances (SPS 384.20)

7.1 Fixture Construction, Clearances, Shower Size & Safing 7.2 Water-Conserving Fixtures, Faucets & Fixture Supply Connectors 7.3 Water Heaters, Water Treatment Devices & Other Plumbing Appliances

8 Chapter 8: Piping Materials, Joints & Supports (SPS 384.30, 384.40, 382.60)

8.1 Approved Piping Materials by Service & Lead-Free Rules 8.2 Joints, Connections & Transitions Between Materials (SPS 384.40) 8.3 Hangers, Supports & Protection of Piping (SPS 382.60)

9 Chapter 9: Private Onsite Wastewater Treatment Systems (SPS 383, 385 & Component Manuals)

9.1 POWTS Regulation, Sanitary Permits, Plan Review & Inspection 9.2 Soil & Site Evaluation and In Situ Soil Parameters (SPS 385, SPS 383.44) 9.3 Design Flow, Septic & Holding Tanks and Tank Construction 9.4 Dispersal Components & the DSPS Component Manuals 9.5 POWTS Setbacks, Management, Maintenance Reporting & Abandonment

10 Chapter 10: Cleanouts, Stormwater, Sumps & Multipurpose Piping

10.1 Cleanouts & Manholes (SPS 382.35) 10.2 Stormwater & Clearwater Systems (SPS 382.36) 10.3 Sanitary Sumps, Ejectors & Discharge Points (SPS 382.30 (10), 382.38) 10.4 Multipurpose Piping Systems & NFPA 13D Residential Sprinklers

11 Chapter 11: Special Plumbing Installations & Water Reuse

11.1 Health Care & Related Facilities (SPS 382.50) 11.2 Manufactured Homes, Campgrounds, RV Parks & Dump Stations 11.3 Water Reuse, Plumbing Treatment Standards & Stormwater Infiltration

9.4 Dispersal Components & the DSPS Component Manuals

Key Takeaways Explain This Topic AI

A design that follows a DSPS-recognized component manual needs no performance data at plan review, but any deviation makes it an Individual Site Design reviewed by state staff (SPS 383.60, 383.61).

The mound, at-grade and pressure distribution manuals cap design wastewater flow at 5,000 gpd, and the at-grade manual limits gravity designs to 600 gpd from one- and 2-family dwellings.

Each pressure dose must be at least 5 times the lateral void volume and, per the manuals, no more than 20% of design wastewater flow.

Mound distribution cells are no wider than 10 feet, at least 3 feet apart, on original slopes of 25% or less, with 12 inches of cover at the center and 6 inches at the outer edge.

Pressure networks need distal head of at least 5 feet for 1/8-inch orifices and 2.5 feet for 3/16- and 1/4-inch orifices, with 2 to 10 ft/s in the force main and manifold.

Last updated: October 2026

Why the manuals are on the reference list

The DSPS exam page lists five component manuals among the permitted references: At-Grade Pressure Distribution , Holding Tank , In-Ground Soil Absorption , Mound and Pressure Distribution . It also says candidates need "a working knowledge of the component manuals." Each manual is a product approval under SPS 384.10. The current DSPS versions (mound 2.1, at-grade 3.0, pressure distribution 2.1, holding tank 2.1) are dated May 2022 and approved through the end of May 2027 .

How recognized methods work (SPS 383.60 and 383.61)

A method recognized under SPS 384.10 (3) may be used on any site within its specifications without submitting performance data at plan review.

Deviating from a recognized method's installation or maintenance specifications is a code violation . A design that doesn't fully comply becomes an Individual Site Design (ISD) , which needs exclusive plan review by state staff.

Approval letters impose conditions on every manual-based system: a copy of the approval letter goes with the plans; approved tanks; installation by properly licensed persons; cleanouts per SPS 382.35; grease interceptors for food service; a sanitary permit; and a soil report under SPS 385.40.

Pressure dosing rules in the code (SPS 383.44 (5))

Effluent goes by pressure distribution wherever Tables 383.44-2 or 383.44-3 require it, for example where the 24-inch reduced separation is used for pretreated effluent. Each dose must be at least 5 times the void volume of the distribution laterals. Pressure distribution is not required when rehabilitating a persistently ponded non-pressurized component that has at least 24 inches of unsaturated soil beneath it.

Pressure Distribution Component Manual (version 2.1)

  • Item Requirement
  • Design wastewater flow 5,000 gpd or less
  • Particle size 1/8 inch or less
  • Dose volume At least 5 x lateral void volume and no more than 20% of design flow
  • Distal head At least 2.5 ft for 1/4- and 3/16-inch orifices, 3.5 ft for 5/32-inch, 5 ft for 1/8-inch
  • Network pressure Distal head plus 30% for fittings
  • Velocity in force main and manifold 2 to 10 ft/s
  • Force main diameter 0.75 to 6 inches
  • Manifold diameter 1.25 to 3 inches
  • Lateral diameter 0.75 to 3 inches

Orifice diameter 0.156 to 0.25 in. for effluent over 30 mg/L BOD5 or TSS; 0.125 to 0.25 in. for 30 mg/L or less

  • Lateral spacing 12 to 48 inches; half that spacing to the cell edge
  • Last orifice to cell end 6 to 24 inches
  • Laterals Level or sloped no more than 1 inch back to the manifold

Dose tank, simplex pump Dose volume + reserve (at least one day's flow) + drain-back volume + 6 inches of tank volume

Orifices smaller than 1/8 inch, including drip, are a restricted technology under Table 383.04-1, and the installer needs approved training.

Mound Component Manual (version 2.1)

  • Item Requirement
  • Design wastewater flow 5,000 gpd or less
  • Influent FOG 30, BOD5 220, TSS 150 mg/L monthly averages or less
  • Fill loading rate 1.0 gal/ft2/day if BOD5 or TSS is over 30 mg/L; 2.0 if both are 30 or less
  • Dose At least 5 x lateral void volume, no more than 20% of design flow

Linear loading No more than 4.5 gal/ft/day where soil within 12 inches of fill has an application rate of 0.3 or less

  • Distribution cell width 10 feet or less; long dimension parallel to contours
  • Spacing between cells At least 3 feet

Fill depth at upslope edge At least 6 in. (soils needing 36 in. or less treatment depth) or 12 to 36 in. (soils needing more)

  • Cell depth At least 8 inches plus the pipe size
  • Cover At least 12 in. at the top center and 6 in. at the top outer edge
  • Original slope 25% or less under the basal area
  • In situ soil to groundwater or bedrock under basal area At least 6 inches
  • Fill material ASTM C33 fine aggregate
  • Distribution Pressure network per the Pressure Distribution manual
  • At-Grade Component Manual (version 3.0)

Pressure designs : design flow up to 5,000 gpd; at least one orifice per 2 linear feet of cell; dose at least 5 x void volume and no more than 20% of design flow; linear loading no more than 4.5 gal/ft where soil within 12 inches of the surface is rated 0.3 or less.

Gravity designs : only for one- and 2-family dwellings with design flow up to 600 gpd (public buildings require an ISD). Use a level distribution box or header at the high point, insulated, accessible within 12 inches of grade and checked every year after the frost leaves. Lateral segments no longer than 30 feet.

Geometry : effective width no more than 10 ft; a 5-foot plowed perimeter on each side and end; absorption area = design flow divided by the soil application rate within the top 12 inches.

The at-grade cell sits on plowed in situ soil with stone aggregate and fertile cover (less than 15% gravel).

In-Ground Soil Absorption Component Manual

The in-ground manual covers trenches and beds excavated into the in situ soil, fed by gravity or pressure. The same code limits apply: influent quality, separation to saturation (Table 383.44-3), application rates (Table 383.44-2), setbacks (Table 383.43-1) and pressure dosing where required. Two or fewer one- or 2-family dwellings using gravity distribution to an in-ground cell may be plan-reviewed by the county (Table 383.22-3). Distribution cell stone is washed aggregate 1/2 to 2-1/2 inches with Mohs hardness of at least 3. Geotextile over the cell must meet Table 384.30-12. Leaching chambers must meet ASTM F2418.

Choosing a component

  • Site condition Typical component
  • Deep, permeable soil (36 in. or more of suitable unsaturated soil below the trench) In-ground trench or bed

Saturation or bedrock too shallow for in-ground, but at least 6 in. of in situ soil Mound (fill provides the treatment depth)

  • Moderately shallow limits, relatively undisturbed sloping site At-grade
  • No suitable soil, or a local option allows it Holding tank (5 x flow or 2,000 gal minimum)

Loading diagram... Matching a site to a component manual